Loading...
14-998-0031. THIS DRAWING IS ONLY TO ASSIST IN SHOWING THE SCOPE OF DEMOLITION WORK AND IS NOT INTENDED TO INDICATE ALL DEMOLITION. CONTRACTOR SHALL REMOVE ALL EXISTING ITEMS AS REQUIRED TO COMPLETE THE JOB. 2. NOT ALL ITEMS TO BE DEMOLISHED ARE SHOWN ON THE PLAN. CONTRACTOR SHALL BE RESPONSIBLE FOR PERFORMING A WALK -THRU OF THE PROJECT PRIOR TO SUBMITTING A BID TO THE OWNER FOR IDENTIFYING POSSIBLE CRITICAL ITEMS, NOT OR INCORRECTLY ADDRESSED, WHICH REQUIRE REMOVAL/ RELOCATION. 3. PROVIDE SAFETY FEATURES DURING WORK AS CALLED FOR IN SPECS, APPLICABLE CODES, RULES AND REGULATIONS HAVING JURISDICTION OF THE PROJECT. 4. CUT, REMOVE, PATCH, ALTER AND REFINISH EXISTING CONSTRUCTION AS REQUIRED TO LEAVE WORK COMPLETE AND IN SATISFACTORY MANNER 5. CONTRACTOR IS TO PROTECT ALL UNDER- 8. GROUND OR OTHER CONCEALED UTILITIES HE IS TO INSPECT CEILING AND CHASES TO ASSURE PROPER IDENTIFICATION OF UTILITIES. MECHANICAL AND /OR ELECTRICAL CONTRACTOR ARE TO CAP THEM AS REQUIRED. 6. REMOVE ALL EXISTING ACOUSTICAL TILE CLG. AND SUSPENDED SYSTEMS IN THE RENOVATION AREA AS REQUIRED FOR INSTALLATION OF WORK TO BE DONE. COORDINATE REMOVAL WITH ELECTRICAL CONTRACTOR REGARDING EXISTING LIGHTING FIXTURES ETC- REPLACE CEILING ACCORDINGLY AFTER COMPLETING OF WORK -I. CONTRACTOR IS TO SAW -CUT ALL OPENINGS IN CONCRETE BLOCK WALLS IF REQUIRED. CONTRACTOR SHALL NOT DEMOLISH OPENINGS WITH SLEDGE HAMMER UNTIL OUTLINES HAVE BEEN CUT. GENERAL DEMOLITION NOTES: RENOVATION WORK MAY ENTAIL INTERVENTIONS IN AREAS OUTSIDE OF THE IMMEDIATE SCOPE OF WORK, INCLUDING WORK ABOVE AND /OR BELOW THE FLOOR LEVEL WITHIN THE SCOPE. IT MAY REQUIRE WORK INVOLVING REMOTE UTILITY LINES (ELECTRICAL MECHANICAL, PLUMBING, COMMUNICATIONS). ANY WORK IN AREAS OUTSIDE OF THE IMMEDIATE SCOPE OF WORK SHALL BE ALL- INCLUSIVE, PROVIDING ALL STRUCTURES, UTILITIES, FINISHES AND EQUIP. REQUIRED TO RESTORE THE AREA TO FULLY OPERATIONAL CONDITIONS, TO FULLY COMPLYING RATING INTEGRITY, AND TO MEET OWNER'S APPROVAL ALL WORK AS DESCRIBED IN THIS NOTE IS TO BE PART OF THE BASE CONTRACT PRICE, OR CONTRACT CONTINGENCY ALLOWANCE FOR SUCH WORK. S. CONTRACTOR IS TO COORDINATE DEMOLITION WORK WITH ADMINISTRATION AND IS TO GIVE SUFFICIENT ADVANCE NOTICE OF THE BEGINNING OF WORK IN EACH EXISTING FLOOR TO ADMINISTRATION (12 HOUR MINIMUM) 10. CONTRACTOR SHALL VERIFY EXACT LOCATION OF EXISTING CONCRETE COLUMNS IN AREAS WHERE WALLS ARE BEING REMOVED AND INFORM ARCHITECT OF ANY CONFLICTS BEFORE ANY WALLS ARE REMOVED SO THAT A/E CAN INSPECT THEM FOR CLARIFICATION PRIOR TO PROCEEDING WITH WORK. II. PATCH AND REPAIR ALL EXISTING SURFACES DAMAGED BY DEMOLITION AND /OR INSTAL- LATION OF NEW ELECTRICAL CONDUITS, GAS PIPING, ETC- AS REQUIRED TO MATCH ADJACENT SURFACES AND /OR AS REQUIRED FOR NEW SCHEDULED FINISHES. 12. DEMOLITION IS DENOTED BY BROKEN LINES. 13. FOR REMOVAL OF FIXTURES AND EQUIPMENT SEE ARCHITECTURAL, PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS. 14. PREPARE EXISTING CONCRETE SLAB AS REQ. BY GRINDING, LEVELING WITH ARDEX LEVELER AS PER MANUFACTURERS SPECIFICATIONS. MATCH EXISTING SLAB ELEVATION AS REQUIRED TO RECEIVE NEW SCHEDULED FLOORING MATERIAL. 15. VERIFY WITH CIVIL, PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS ITEMS TO BE REMOVED /RELOCATED IN CASE OF CONFLICT. 16. DESTINATION OF ALL EXISTING EQUIPMENT, PLUMBING FIXTURES, DOORS AND FRAMES, ETC. TO BE REMOVED SHALL BE COORDINATED WITH THE OWNER 1 -1. CONTRACTOR TO SURVEY PROJECT AREA PRIOR TO COMMENCEMENT OF WORK NOTE AND REPAIR ANY DAMAGE TO AREAS WHERE WORK IS GOING TO BE PERFORMED. NOTIFY OWNER AND ARCHITECT WITH A LIST OF WORK PRIOR TO CONTRACT. PART 1,4L pEMOLITION PLAN SCALE: 1 /4' = 1' -0' NOTE: FOR ADDITIONAL 'ICRA INFORMATION' SEE MECHANICAL DRAWINGS. DEMOL (T 011 _PLAN LF61= ND C EXISTING REINFORCED CONC. . COLUMN OR CONCRETE WALL TRANSPORT IN TIGHLY COVERED CONTAINERS DNL ;-LOUR FIRE-RA-TE_0 WALL / PA-.-PTITfON (SEE PARTITION TYPES) - BEFORE TRANSPORTING. ONE HOUR FIRE / SMOKE RATED WALL / PARTITION -- -- _(SE A 7TAON _ WALL C ' _EXISTING PART1TILW TO RE�4A N - w WALL OR PARTITION WITH 6. SEAL HOLES, PIPES, CONDUITS AND PUNCTURES EXISTING DOOR TO REMAIN — — — — — EXISTING WALL OR — — — — — PARTITION TO BE REMOVED rWALL OR PARTITION WITH EXISTING DOOR TO BE REMOVED DEMOLITION SYMBOL (SEE DEMOLITION LEGEND) DENOTES EXISTING AREAS OUTSIDE THE SCOPE OF WORK DEMOLITION NOTES: OI REMOVE EXISTING DOOR AND FRAME. O REMOVE EXISTING PARTITION WALL AS SHOWN - PROVIDE ROUGH OPENING FOR A 4' -0' x 'V-0' x 1 3/4' DOOR (SEE DOOR SCHEDULE) O3 REMOVE EXISTING FLOOR FINISH AS REQUIRED. PATCH AND LEVEL TO RECEIVE NEW FINISH FLOOR O REMOVE EXISTING ELECTRICAL OUTLETS, SWITCHES, LIGHT FIXTURES AND DEVICES. (SEE ENGINEERING DRAWINGS). O REMOVE EXISTING CEILING TILES AND SUPPORT SYSTEM (INCLUDED SOFFIT WITH A.G.T. FINISH). O SAW CUT EXISTING SLAB TO PROVIDE ACCESS UNDERGROUND FOR THE INSTALLATION OF THE DRAINAGE LINES. SEE PLUMBING DRAWINGS FOR COORDINATION. O REMOVE EXISTING PORTION OF HANDRAIL, AND REPAIR TO MATCH EXISTING. O REMOVE EXISTING WALL MOUNTED i x 4 FLUORESCENT LT'G FIXTURES - FIX / REPAIR WALL AS REQUIRED TO MATCH EXISTING. O REMOVE EXISTING CHAIRAIL - REPAIR / PATCH AS REQUIRED TO MATCH EXISTING. tm SEE FIRE SPRINKLER DRAWINGS FOR REQUIRED SCOPE OF WORK. RE G2U I RE D I CR�4 PRE C:AUT IONS FOR CLASS III • DURING CONSTRUCTION PROJECT I. REMOVE OR ISOLATE HVAC SYSTEM IN AREA WHERE WORK IS BEING DONE TO PREVENT CONTAMINATION OF DUCT SYSTEM. 2. COMPLETE ALL CRITICAL BARRIERS I.E. SHEETROCK, PLYWOOD, PLASTIC, TO SEAL AREA FROM NON WORK AREA OR IMPLEMENT CONTROL CUBE METHOD (CART WITH PLASTIC COVERING AND SEALED CONNECTION TO WORK SITE WITH HEPA VACUUM FOR VACUUMING PRIOR TO EXIT) BEFORE CONSTRUCTION BEGINS. 3. MAINTAIN NEGATIVE AIR PRESSURE WITHIN WORK SITE UTILIZING HEPA EQUIPPED AIR FILTRATION UNITS. 5� < UPON COMPLETION OF PROJECT �w a ? I. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT IS INSPECTED BY THE OWNER'S STAFF. jJtH MIA 2. VACUUM WORK AREA WITH HEPA FILTERED VACUUMS. DEPT. 3. WET MOP/WIPE EXPOSED SURFACES WITH APPROPRIATELY LABELED AND BHSF APPROVED L SECTION HOSPITAL DISINFECTANT. 4. CONTAIN CONSTRUCTION WASTE IN TIGHTLY COVERED CONTAINERS BEFORE TRANSPORTING. COVER TRANSPORT RECEPTACLES OR CARTS. TAPE COVERING UNLESS SOLID LID. REMOVE ISOLATION OF HVAC SYSTEM IN AREAS ' WHERE WORK IS BEING PERFORMED. �. REMOVE BARRIER MATERIALS CAREFULLY TO MINIMIZE SPREADING OF DIRT AND DEBRIS ASSOCIATED WITH CONSTRUCTION. 8. FINAL CLEANING BY ENVIRONMENTAL SERVICES PRIOR TO OCCUPANCY. coutqv R .. M FIRST AT ..- S.W. 62ND AVENUE LOCATION PLAN Q alon. D D D D z O A V1 �0 wx z H� z W 20 V Lo Z<p H U) O 1.4 x O C 4. CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN TIGHLY COVERED CONTAINERS BEFORE TRANSPORTING. z o it 5. COVER TRANSPORT RECEPTACLES OR CARTS. y TAPE COVERING UNLESS SOLID LID. w 6. SEAL HOLES, PIPES, CONDUITS AND PUNCTURES APPROPRIATELY. 5� < UPON COMPLETION OF PROJECT �w a ? I. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT IS INSPECTED BY THE OWNER'S STAFF. jJtH MIA 2. VACUUM WORK AREA WITH HEPA FILTERED VACUUMS. DEPT. 3. WET MOP/WIPE EXPOSED SURFACES WITH APPROPRIATELY LABELED AND BHSF APPROVED L SECTION HOSPITAL DISINFECTANT. 4. CONTAIN CONSTRUCTION WASTE IN TIGHTLY COVERED CONTAINERS BEFORE TRANSPORTING. COVER TRANSPORT RECEPTACLES OR CARTS. TAPE COVERING UNLESS SOLID LID. REMOVE ISOLATION OF HVAC SYSTEM IN AREAS ' WHERE WORK IS BEING PERFORMED. �. REMOVE BARRIER MATERIALS CAREFULLY TO MINIMIZE SPREADING OF DIRT AND DEBRIS ASSOCIATED WITH CONSTRUCTION. 8. FINAL CLEANING BY ENVIRONMENTAL SERVICES PRIOR TO OCCUPANCY. coutqv R .. M FIRST AT ..- S.W. 62ND AVENUE LOCATION PLAN Q alon. D D D D z O A V1 �0 wx z H� z W 20 V Lo Z<p H U) O 1.4 x O C J o it w V• Z Lo, 0 . a z z ca H0z a' 0 z w V A� PERMIT SET 08/01/14 DRAWL GAC CHECKED. LEN DATE: 01-29 -14 SCALE: AS SHOWN 0 p r 63 ►� r Sheet No. A -1 OF 8 )0$ f 201426