14-585-001w PARTIAL FIRE ALARM FLOOR PLAN. SCALE 1 /8" = 1' 0" BATTERY CALCULATION FACP FACP m STANDBY QTY. CURRENT .250 1 TOTAL ALARM CURRENT .250 .250 1 QTY. TOTAL .250 ANN � .05 1 .05 .1 1 .1 UDACT uj .04 1 .04 .1 1 1 DETECTORS J .0003 140 .042 o PULL STATIONS Q .00035 1 .0063 .4 1 RELAY FRM -1 J .000255 1 MODULE FMM -1 C-14 .00035 41 .01435 Lo Q w 04 FLOW BEL Z .040 1 V) z Q O J TOTAL STANDBY = .4118 TOTAL ALARM = .89 STANDBY:24HRS _ ALARM: 5 MIN. X 1/60 = .0833 HOURS = REQUIRED STANDBY 24 X TOTAL STANDBY .4118 REQUIRED STANDBY AMP /HRS = 9.8832 REQUIRED TOTAL ALARM TIME ALARM .0833 X .89 REQUIRED ALARM CAP. = .07414 REQUIRED STANDBY AMP /HRS. 9.8832 + REQUIRED ALARM CAP. .07414 TOTAL REQUIRED CAP. = 9.9573 X OPTIONAL REQUIRED SAFETY BATTERY FACTOR CAP. 1.2 = 11.949 BATTERY SIZE: 12.0 AMP HRS SCOPE OF WORK SCOPE OF WORK CONSIST OF ADDING DEVICES TO AN EXISTING FIRE ALARM SYSTEM. WE WILL BE INSTALL 1 SMOKE DETECTOR, 2 DUCT DETECTORS, 3 RELAY MODULES. AND 1 HORN STROBE AT MECHANICAL ROOM FIRST FLOOR. EXISTING FIRE ALARM CONTROL PANEL NOTIFIER. EXISTING BOOSTER POWER SUPPLY. F[RE ALARM SYSTEM TO BE w, s i iul-Eis L 3 P.CCORDAlNCE wnb NFPA 72; 70;101 FIRE ALARP 9 S? 1f_ aE �, � ,TATE STAT�'-I WE-" SlH �. AGE o TED AT 0,;Z PLkCA n SH �,LLn PER FPA 72 F VIAL iNSF't T I F IST PAU� LEGEND FACP EXISTING FIRE ALARM PANEL NOTIFIER MODEL NFS -320 uoncr UDACT NOTIFIER UNIVERSAL DIGITAL ALARM COMMUNICATOR TRANSMITTER ANN EXISTING ANNUNCIATOR NOTIFIER MODEL LCD -80 FBT31 BOOSTER POWER SUPPLY NOTIFIER FCPS- 24S6 -8 / MAX 6.0 -8.0 AMP. 0 PULL STATION WEATHERPROOF "�' NOTIFIER NBG -12LOB W /MINI MONITOR MODULE FMM -101 PULL STATION NOTIFIER NBG -12LX O SMOKE DETECTOR. NOTIFIER FSP -851 0o DUCT DETECTOR. NOTIFIER DNR np HEAT DETECTOR. NOTIFIER FST -851 HORN /STROBE CEILING MOUNT SYSTEM SENSOR PC2R HORN /STROBE SYSTEM SENSOR P2R wp HORN /STROBE SYSTEM SENSOR P2RK WEATHERPROOF Q STROBE CEILING MOUNT SYSTEM SENSOR SCR STROBE LIGHT SYSTEM SENSOR SR © FLOW BELL WHEELOCK MB- G6 -24R Ei RELAY MODULE NOTIFIER FRM -1 MONITOR MODULE FOR TAMPER AND FLOW SWITCH NOTIFIER FMM -1 WE EXISTING DEVICES 0 NEW DEVICES A 2/18 AWG FPLP 300V MIN. B 2/16 AWG FPLP 300V MIN. C 3/12 AWG THHN - BLACK/ WHITE/ GREEN @600V EMT 1/2" MIN. FIRE ALARM NOTES 1— EXISTING FACP NOTIFIER NFS -320 ADDRESSABLE W/ 159 SENSOR AND 159 MODULE CAPACITY. LOCATED AT TELEPHONE ROOM ON 1ST FLOOR WITH CAPACITY 6.OAMP. 2 —FIRE ALARM SYSTEM SHALL BE POWER LIMITED. 3 —ALL ALARM DEVICES SHALL BE UL LISTED FOR FIRE. 5 —ALL DEVICES SHALL BE COMPATIBLE WITH FIRE ALARM CONTROL PANEL. 6 —BUILD OUT SPACE WITH 2.230.00 SQUARE FOOTAGE AT EXISTING BUILDING 1ST FLOOR. BUILDING FULLY FIRE SPRINKLERED. 7— DEDICATED 120VAC BRANCH CIRCUIT WITH LOCK FOR FACP AND BOOSTER POWER SUPPLIES. BREAKER ®20 AMP IN ELECTRICAL PANEL. 8 —EMT CONDUIT SHALL BE 1/2" MINIMUM. 9— PERCENTAGE FILL AT 40 % MAXIMUM. 10— CONDUIT UP TO 8 FEET AND FREE WIRING. 11 —CABLE 18/16 AWG FPLP OR THHN OR EQUAL @300V MIN & 12 AWG THHN OR ROMEX ® 600V MIN. 12 —ALARM IS GENERAL TEMPORAL TONE ON ALL INITIATING DEVICES. 13— SYSTEM INITIATING CIRCUIT SHALL BE CLASS "B" STYLE 4. 14 —ALL CONTROL RELAY SHALL BE WITHIN 3 FEET OF DEVICES BEING. 15— SYSTEM SIGNAL SHALL BE CLASS "B" STYLE Y. 16— VISUAL ALARM TO COMPLY W/ ANSI A117.1,4.26 AND NFPA 72 AND F.B.C. 2001 ED. 17 —WALL MOUNTED VISUAL DEVICES ® 80" TO 96 "AFF BOTTOM OF LENS OR 6" FROM CEILING WHICHEVER IS LOWER & CEILING MOUNT. 18 —NEW STROBES 15/75CD MINIMUM TO COMPLY WITH FLORIDA ACCESSIBILITY CODE. 20 —ALL NEW STROBES ARE 15/75CD MINIMUM. 21— CEILINGS ARE FLAT AND 10 FEET HIGH OR LESS. 22— CEILING MOUNTED SMOKE DETECTORS SHALL NOT BE LOCATED IN A DIRECT AIRFLOW, NOR CLOSER THAN 3 FEET FROM AN AIR SUPPLY DIFFUSER. NFPA 72 A -5 -3.6.1 AND A -5- 5.7.1. 23 —THERE IS NO EM CONTROL ON THIS SYSTEM. 24— MANUAL INITIATING DEVICES MOUNT ® 42" TO 54 "AFF. 25 —THIS IS AN EXISTING CERTIFIED CENTRAL STATION FIRE ALARM SYSTEM. REPORTING BY TWO TELEPHONE LINES. 26— NOTIFICATION APPLIANCES WILL BE INSTALLED AS PER NFPA- 72.7.4.3 PRIVATE MODE AUDIBLE REQUIREMENT 27— BATTERY CALCULATION 0 24HR STANDBY AND 5 MINUTE IN ALARM. 28 —ALL REMOTE PANEL ARE PROTECTED WITH SMOKE DETECTOR. 29 —VALUE OF WORK UNDER $5,000.00. 30 —THE DESIGN INSTALLATION COMPLIES WITH FBC 2010 EDITION. 31— EXISTING FIRE ALARM ANNUNCIATOR LCD -80 LOCATED BY MAIN ENTRANCE. 32— BUILDING DOES NOT HAVE A PIV AND BACK FLOW PREVENTOR VALVE. 33— EXISTING FLOW BELL LOCATED NEAR THE FIRE DEPARTMENT CONNECTION. DATE 04/16/14 DRAWN 6Y: C.N. SCALE: 1/81' = 1' CHI ALA.Trs, wo. F -1 SHEET 10F 2 m O � N U O 0 uj Z LLJ M ,n J � P� o Q a M J Q Q C-14 LL- o Lo Q w 04 Q Z N V) z Q O J 00 _ ui = O Q ►� U`r_W r-QZ �_ I— CL DATE 04/16/14 DRAWN 6Y: C.N. SCALE: 1/81' = 1' CHI ALA.Trs, wo. F -1 SHEET 10F 2 m O O J W r� a Q C-14 LL- o V) z L.LJ N Z CD Q J w I— DATE 04/16/14 DRAWN 6Y: C.N. SCALE: 1/81' = 1' CHI ALA.Trs, wo. F -1 SHEET 10F 2