13-185-031GENERAL CONDITIONS: A. THE SCOPE OF THE WORK SHALL INCLUDE THE FURNISHING AND INSTALLATION OF THE NECESSARY MATE81AL AND LABOR TO ACCOMPUSH THE WORK INDICATED BY THE DRAWINGS AND HEREIN SPECIFIED. ALL WORK BY THIS CONTRACTOR SHALL CONFORM TO ALL APPLICABLE FEDERAL, STATE AND LOCAL BUILDING CODES. B. CONTRACTOR SHALL BE RESPONSIBLE FOR REVIEWING THE EXISTING CONDITIONS AT THE JOB SITE BEFORE SUBMITTING PROPOSALS. SUBMISSION OF PROPOSALS SHALL BE TAKEN AS EVIDENCE THAT SUCH INSPECTION HAS TAKEN PLACE. THE CONTRACTOR SHALL BECOME FAMILIAR WITH THE COMPLETE SET OF CONSTRUCTION DOCUMENTS, AND THE LACK OF SPECIFIC INFORMATION ON THE DRAWINGS SHALL NOT RELIEVE THE CONTRACTOR OF ANY RESPONSIBIUTY. C. MATERIALS AND EQUIPMENT FURNISHED UNDER THIS CONTRACT SHALL BE NEW AND SHALL BEAR THE UL LABEL WHERE APPLICABLE, UNLESS NOTED OTHERWISE. ALL WORK SHALL BE GUARANTEED AGAINST DEFECTIVE MATERIALS AND WORKMANSHIP FOR A PERIOD OF NOT LESS THAN ONE (1) YEAR AFTER COMPLETION AND ACCEPTANCE BY THE OWNER. D. CONTRACTOR SHALL INSTALL MECHANICAL SYSTEMS WITHOUT INTERFERENCE AND IN STRICT COORDINATION WITH OTHER TRADES. E. MATERIALS AND WORKMANSHIP SHALL COMPLY WITH THE CONTRACT DOCUMENTS AND APPLICABLE CODES AND STANDARDS. IN CASE OF DIFFERENCE BETWEEN APPLICABLE CODES AND STANDARDS AND THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL PROMPTLY NOTIFY THE ARCHITECT /ENGINEER AND THE OWNER IN WRITING OF SUCH DIFFERENCE. SHOULD THE CONTRACTOR PERFORM ANY WORK THAT DOES NOT COMPLY WITH THE REQUIREMENTS OF APPLICABLE CODES AND STANDARDS, HE SHALL BEAR ALL COSTS ARISING IN CORRECTING SUCH DEFECTS. APPLICABLE CODES AND STANDARDS SHALL INCLUDE ALL ORDINANCES, UTILITY COMPANY REGULATIONS, AND APPUCABLE REQUIREMENTS OF NATIONALLY ACCEPTED CODES AND STANDARDS. SHOULD THE CONTRACTOR SUPPLY EQUIPMENT DIFFERING FROM THE SPECIFIED ITEMS IN THE CONTRACT DOCUMENTS WITHOUT NOTIFICATION TO THE ENGINEER, HE SHALL BEAR ALL COSTS TO UPGRADE DEFICIENCIES ARISING FROM SUCH. F. WHERE ONLY ONE MANUFACTURER'S NAME IS USTED IN THE EQUIPMENT SPECIFICATION, OTHER MANUFACTURERS OF SIMILAR CHARACTERISTICS AND OF EQUAL OR BETTER PERFORMANCE CAPACITIES MAY BE CONSIDERED FOR OR EQUAL" APPROVAL BY THE ENGINEER. WHERE MORE THAN ONE MANUFACTURER IS USTED IN THE NOTES AND EQUIPMENT SPECIFICATIONS, ONLY THOSE NAMED MANUFACTURERS WILL BE CONSIDERED FOR APPROVAL G. SHOULD A SUBSTITUTION BE ACCEPTED, AND SHOULD THE SUBSTITUTE MATERIAL PROVE DEFECTIVE, OR OTHERWISE UNSATISFACTORY FOR THE SERVICE INTENDED WITHIN THE GUARANTEE PERIOD, THIS MATERIAL OR EQUIPMENT SHALL BE REPLACED WITH THE MATERIAL OR EQUIPMENT SPECIFIED AT NO COST TO THE OWNER. H. PROVIDE ACCESS, INCLUDING NECESSARY ACCESS DOORS, FOR NEW AND EXISTING EQUIPMENT REQUIRING OPERATION AND /OR MAINTENANCE. RELOCATE EXISTING AND LOCATE ALL NEW EQUIPMENT SUCH THAT OPERATION OR MAINTENANCE IS NOT RESTRICTED. I. DO NOT RUN PIPING OR DUCTWORK, OR LOCATE EQUIPMENT, WITH RESPECT TO SWITCHBOARDS, PANELBOARDS, POWER PANELS, MOTOR CONTROL CENTERS OR DRY TYPE TRANSFORMERS, WITHIN 42 INCHES IN FRONT OF EQUIPMENT, OVER EQUIPMENT, OR WITHIN 36 INCHES HORIZONTALLY OF SAME SPACE. J. PROVIDE SNAP -ON OR ADHESIVES LABELS INDICATING CHILLED OR HOT WATER SUPPLY AND RETURN, CONDENSATE DRAINAGE, DOMESTIC HOT AND COLD WATER, MEDICAL GASES, ETC. 11 MECHANICAL DEMOLITION A. UNLESS NOTED OTHERWISE, THE MECHANICAL DEMOLITION SHALL BE CARRIED OUT TO THE EXTENT THAT THE FLOORS ARE RETURNED TO THE ORIGINAL BASE BUILDING CONDITIONS. CONTRACTOR SHALL VERIFY ALL EXISTING FIELD CONDITIONS IN ORDER TO ACCURATELY DETERMINE THE EXTENT OF THE WORK UNDER THIS SECTION. B. UNLESS NOTED OTHERWISE, REMOVE EXISTING INTERIOR DIFFUSERS, GRILLES, AND DUCTWORK AS INDICATED PLANS. EXISTING DIFFUSERS AND GRILLES MAY BE REUSED IF THEY MEET THE SCHEDULED SPECIFICATIONS. EXISTING BASE BUILDING SLOT DIFFUSERS ARE TO REMAIN EXCEPT WHERE INDICATED ON PLANS. C. EXISTING THERMOSTATS AND /OR TEMPERATURE SENSORS ARE TO BE RELOCATED AND REUSED IF IN GOOD WORKING CONDITION. D. WASTE, DOMESTIC WATER, AND VENT PIPING SHALL BE REMOVED BACK TO RISER STACK CONNECTIONS AND CAPPED, UNLESS NOTED OTHERWISE. E. EXISTING DUCTWORK SHOWN ON PLANS MAY NOT EXACTLY MATCH THE ACTUAL FIELD CONDITIONS. IT IS NOT NECESSARY TO REWORK THE DUCTWORK IN ORDER TO MATCH WHAT IS DEPICTED ON THE PLANS. CONTRACTOR SHALL VERIFY EXISTING DUCTWORK ROUTING AND LOCATIONS AND MAKE ADJUSTMENTS AS REQUIRED TO AVOID CONFLICTS WITH NEW DUCTWORK, EQUIPMENT, UGHT FIXTURES, ETC.. III PRODUCTS, EQUIPMENT AND EXECUTION: A. SANITARY DRAIN LINES (SOIL, WASTE AND VENT) SHALL BE AMERICAN MANUFACTURED SERVICE WEIGHT CAST IRON OR DWV COPPER PIPE. JOINTS SHALL BE FABRICATED BY THE USE OF COMPRESSION JOINTS SIMILAR TO TYLER PIPE AND FOUNDRY'S "TY -SEAL" FOR CAST IRON PIPE OR 95/5 SOLDER FOR DWV COPPER PIPE. NO -HUB CAST IRON PIPE ASSEMBLED WITH STAINLESS STEEL /NEOPRENE HUBLESS COUPUNGS SHALL BE LIMITED TO ABOVE GROUND INSTALLATIONS. B. DOMESTIC WATER PIPING INSTALLED ABOVE GROUND SHALL BE AMERICAN MANUFACTURED TYPE "L" HARD DRAWN COPPER ASSEMBLED WITH 95/5 SOLDER AND WROUGHT COPPER JOINT FITTINGS. C. RELIEF AND DRAIN PIPING SHALL BE AMERICAN MANUFACTURED TYPE "M" COPPER WITH 95/5 SOLDER JOINT FITTINGS OR SCHEDULE 40 BLACK STEEL PIPES WITH SCREWED FITTINGS. G. FITTINGS AND PIPING CONNECTED WITH PLUMBING FIXTURES SHALL BE BRASS AND, WHEREVER EXPOSED, SHALL BE POLISHED CHROME - PLATED. H. FURNISH AND INSTALL ALL REQUIRED WATER, WASTE, SOIL, AND VENT CONNECTIONS TO ALL PLUMBING FIXTURES AND EQUIPMENT, TOGETHER WITH ALL FITTINGS, SUPPORTS, FASTENING DEVICES, COCKS, VALVES, TRAPS, ETC., LEAVING ALL IN COMPLETE WORKING ORDER. I. PLUMBING FIXTURES SHALL BE PROVIDED AS SCHEDULED ON 'THE DRAWINGS. PLUMBING FIXTURES SHALL BE NEW, EXCEPT WHERE NOTED, AND SHALL BE APPROVED BY THE APPLICABLE WATER CONSERVATION AUTHORITY. THE PLUMBING CONTRACTOR SHALL PROVIDE NECESSARY CHROME PLATED P- TRAPS, SUPPLIES WITH STOPS, RISERS, INLET DRAINS, ETC. J. SHOCK ARRESTORS SHALL BE SIMILAR TO JOSAM 75000 OR AS MANUFACTURED BY PPP AND SIOUX CHIEF SIZED AS PER THE PDI. K. FIXTURE CARRIERS SHALL BE PROVIDED FOR WATER CLOSETS, URINALS AND LAVATORIES AS REQUIRED AND SHALL BE FLOOR SUPPORTED AS MANUFACTURED BY JOSAM. L TRAP PRIMERS SHALL BE AS REQUIRED BY LOCAL CODES AND SIMILAR TO J.R. SMITH FIR 2698 WATER SAVER TRAP PRIMER. M. FLOOR DRAINS SHALL BE SIMILAR TO JOSAM SERIES 30000 CAST IRON FLOOR DRAIN WITH NICKALOY STRAINER. N. CLEANOUTS SHALL BE PROVIDED IN SANITARY WASTE UNES AS SHOWN AND AT EACH CHANGE OF DIRECTION GREATER THAN 45 DEGREES. WALL CLEANOUTS SHALL BE SIMILAR TO JOSAM 5879 WITH BRONZE PLUG AND STAINLESS STEEL COVER. FLOOR CLEANOUTS SHALL BE SIMILAR TO JOSAM 56020 WITH CARPET MARKER FOR CARPETED FLOORS. 0. PIPE, EQUIPMENT, ETC., SHALL BE PROPERLY SUPPORTED FROM STRUCTURE WITH THE USE OF APPROVED TYPE CLEVIS, TRAPEZE HANGERS OR FLOOR STANDS WITH SPACING AS FOLLOWS: 1. STEEL PIPE OR COPPER TUBING - 1 -1/2" OR LESS, 6 FOOT INTERVALS. 2. CAST IRON - ONE (1) HANGER PER LENGTH OF PIPE AND NOT EXCEEDING 10' -0" O.C. 3. FITTINGS - WITHIN 2' -0" OF EACH CHANGE OF DIRECTION. P. INSULATION SHALL BE PROTECTED AT HANGERS BY A SECTION OF CALCIUM SIUCATE PIPE INSULATION AND A 12" LONG HALF -ROUND SHEET METAL SHIELD ON THE OUTSIDE OF THE INSULATION. EXTEND PIPING INSULATION FULL THICKNESS WITHOUT INTERRUPTION THROUGH WALLS, FLOORS AND SIMILAR PENETRATIONS. Q. PROVIDE AND INSTALL UNIONS AT PROPER POINTS TO PERMIT REMOVAL OF A PIPE, EQUIPMENT, ETC., WITHOUT INJURY TO OTHER PARTS OF THE SYSTEM AND TO PREVENT CORROSION DUE TO ELECTROLYSIS. ALL EQUIPMENT SHALL BE INSTALLED IN A MANNER TO PERMIT ACCESS FOR SERVICE WITHOUT DISASSEMBLY. UNIONS SHALL BE DIELECTRIC WHERE DISSIMILAR MATERIALS OCCUR. PRESSURE RATINGS SAME AS FITTINGS. R. ALL DOMESTIC COLD WATER AND HOT WATER PIPE AND FITTINGS SHALL BE INSULATED WITH %- THICK OWENS- CORNING FIBERGLASS 25 ASJ /SSL OR APPROVED EQUAL V. PROVIDE INSULATION PRODUCTS MANUFACTURED BY JOHNS- MANVILLE, OWENS- CORNING, ARMSTRONG AND CERTAINTEED. FIBERGLASS PIPE INSULATION SHALL BE ASTM C547 -77, CLASS 1. PROVIDE BANDS, WIRES, AND CEMENT AS RECOMMENDED BY INSULATION MANUFACTURER FOR THE APPLICATIONS INDICATED. FLEXIBLE FIBERGLASS DUCTWORK INSULATION SHALL BE ASTM C553 -70, TYPE I, CLASS B3. 1. PROVIDE COMPOSITE INSULATION (INSULATION JACKETS, COVERINGS, SEALERS, MASTICS AND ADHESIVE) WITH FLAME- SPREAD RATINGS OF 25 OR LESS AND A SMOKE - DEVELOPED RATING OF 50 OR LESS, AS TESTED BY ASTM K04 (HFFA 255) METHOD. 2. MAINTAIN INTEGRITY OF VAPOR BARRIER JACKETS ON PIPE AND DUCTWORK INSULATION, AND PROTECT TO PREVENT PUNCTURE OR OTHER DAMAGE. SEAL OPEN ENDS OF INSULATION WITH MASTIC. SECTIONALLY SEAL ALL BUTT ENDS OF CHILLED WATER INSULATION OF FITTINGS WITH WHITE VAPOR BARRIER COATING. EXTEND PIPING INSULATION WITHOUT INTERRUPTION THROUGH WALLS, FLOORS AND SIMILAR PIPING PENETRATIONS, EXCEPT WHERE OTHERWISE INDICATED. INSTALL PROTECTIVE METAL SHIELDS AND FOAM GLASS INSERTS WHERE PIPE HANGERS BEAR ON OUTSIDE OF INSULATION. X. RECTANGULAR "LOW PRESSURE" SHEET METAL DUCT SHALL BE FABRICATED OF CONTINUOUS HOT DIP MILL GALVANIZED MINIMUM 26 GAUGE STEEL SHEETS AND INSTALLED IN ACCORDANCE WITH SMACNA STANDARDS FOR 1.0" W.C. AND FOR THE FIRST 10 TO 15 FEET DOWNSTREAM OF A TERMINAL UNIT (FP /VAV OR VAV) SHALL HAVE AN INTERNAL DUCT UNING EQUAL TO JOHNS- MANVILLE PERMACOTE LINACOUSTIC, 1" THICK, 1.5 LB. DENSITY DUCT LINER. (DUCTS FOR MEDICAL WORK SHALL NOT BE LINED, BUT WILL BE WRAPPED.) Y. ROUND "LOW PRESSURE" DUCT FITTINGS SHALL BE FABRICATED OF CONTINUOUS HOT DIP MILL GALVANIZED MINIMUM 26 GAUGE STEEL SHEETS AND INSTALLED IN ACCORDANCE WITH SMACNA RECOMMENDATIONS FOR 0. W.C. Z. RECTANGULAR AND ROUND "PRIMARY AIR" SHEET METAL DUCT AND FITTINGS SHALL BE FABRICATED OF CONTINUOUS HOT DIP MILL GALVANIZE MINIMUM 26 GAUGE STEEL SHEETS AND INSTALLED IN ACCORDANCE WITH SMACNA STANDARDS FOR 3.0" W.C., AND RECTANGULAR DUCT SHALL HAVE AN INTERNAL DUCT UNING EQUAL TO JOHNS - MANVILLE PERMACOTE LINACOUSTIC, 1" THICK, 1.5 L.B. DENSITY DUCT LINER (DUCTS FOR MEDICAL WORK SHALL NOT BE LINED, BUT WILL BE WRAPPED). CONSTRUCTION METHODS: 1. RECTANGULAR - DUCTMATE SYSTEM 2. ROUND - SPIRAL DUCT SYSTEM A. AA. ROUND DUCTS AND UNLINED RECTANGULAR DUCTS SHALL BE INSULATED WITH 3/4 POUND PER CUBIC FOOT MINIMUM DENSITY, 2" THICK COMMERCIAL GRADE, OWENS- CORNING FIBERGLASS FOIL BACKED ALL SERVICE DUCT WRAP, OR EQUAL. BB. FLEXIBLE DUCTS SHALL BE FLEXMASTER TYPE 8M, THERMAFLEX MKE OR WIREMOLD WK. FLEXIBLE DUCTS SHALL BE USTED AS U.L 181 CLASS (1) AIR DUCT AND SHALL COMPLY WITH NFPA STANDARDS 90A AND 90B. CC. CONTRACTOR SHALL BALANCE THE HVAC SYSTEMS FOR DESIGNATED AIR AND WATER QUANTITIES AND SHALL BE N.E.B.B. OR A.A.B.C. APPROVED. SUBMIT REPORT ON NEBB, AABC, OR SMACNA FORMS FOR APPROVAL BY THE ENGINEER. EXTENT OF BALANCING WORK TO INCLUDE REBALANCING 0 EXISTING SUPPLY AND EXHAUST SYSTEMS AS REQUIRED TO ACHIEVE DESIG CFM ON SUBJECT PROJECT. DD. DUCT ACCESS DOORS: PROVIDE RIGID AND CLOSE FITTING DOORS OF GALVANIZED STEEL WITH SEALING GASKETS AND QUICK FASTENING LOCKING DEVICES. FOR INTERNALLY LINED OR INSTALLED DUCTWORK, INSTALL MINIMUM ONE INCH THICK INSULATION WITH SHEET METAL COVER. INSTALL AT EACH FIRE DAMPER. DOORS TO BE EQUAL TO FLEXMASTER " THE INSPECTOR SERIES." EE. FURNISH AND INSTALL SMOKE, FIRE AND /OR FIRE /SMOKE DAMPERS WHERE SHOWN ON THE DRAWINGS, AND REQUIRED BY THE GOVERNING AUTHORITY. DAMPERS SHALL BE INSTALLED AS RECOMMENDED BY SMACNA AND COMPLY WITH U.L. AND LOCAL ORDINANCES AS REQUIRED BY THE GOVERNING AUTHORITY. FF. "VARIABLE- VOLUME" SINGLE DUCT TERMINAL BOX SHALL BE MEDIUM PRESSURE, VARIABLE AIR VOLUME, SINGLE DUCT, PRESSURE INDEPENDENT TERMINAL UNIT WITH 2 P.C.F. DENSITY MINIMUM INSULATED CASING AND FLOW CONTROLLER. VARIABLE VOLUME TERMINAL BOXES SHALL BE ENVIRO -TEC SSD -11, TITUS ESV -3000, NAILOR OR TEMPMASTER. UU. TEMPERATURE CONTROLS: 1. ALL TEMPERATURE CONTROLS NECESSARY FOR THE RENOVATION AND FINISH -OUT OF THE SPACE SHALL COMPLY TO THE BASE BUILDING SYSTEM AND CONTROL SPECIFICATIONS. BUILDING STANDARD CONTROL SYSTEM COMPONENTS SHALL BE UTIUZED. 2. NEW THERMOSTATS OR SENSORS SHALL MATCH THE EXISTING THERMOSTATS OR SENSORS. 3. ALL CONTROL WIRING AND POWER WIRING FOR CONTROLS SHALL BE BY THE CONTROLS SUB - CONTRACTOR. 4. TERMINAL UNITS, FAN -COIL UNITS AND MOTORIZED SUPPLY AIR DAMPERS SHALL BE CONTROLLED BY ROOM [THERMOSTATS PIPED WITH MAIN CONTROL PRESSURE AND BRANCH PRESSURE FROM THERMOSTAT] [SENSORS WITH TWISTED PAIR, PLENUM RATED CABLE FROM SENSORS] TO OPERATORS, CONTROL VALVES, ETC. 5. THE FAN COIL UNITS SHALL BE CONNECTED TO THE BASE BUILDING ENERGY MANAGEMENT SYSTEM FOR START AND STOP SCHEDULES. [THE CONTROL PANEL IS LOCATED IN THE MECHANICAL ROOM.] THE AUXILIARY CONTACTS IN THE STARTER/DISCONNECTS SHALL BE USED TO AUTOMATE THE START AND STOP FUNCTIONS. 6. AT THE COMPLETION OF CONSTRUCTION, ALL NEW AND EXISTING THERMOSTATS AND SENSORS SHALL BE CALIBRATED. YY. TEST AND BALANCE: 1. THE GENERAL CONTRACTOR SHALL RETAIN THE SERVICES OF AN INDEPENDENT CERTIFIED AIR BALANCE FIRM TO PERFORM THE TESTING AND BALANCING AND PREPARE REPORTS TO THE GENERAL CONTRACTOR. IF THE MECHANICAL CONTRACTOR IS NEBB CERTIFIED, THEY CAN BALANCE THE SYSTEM. 2. TESTING AND BALANCING SHALL BE PERFORMED IN ACCORDANCE WITH THESE SPECIFICATIONS AND IN ACCORDANCE WITH THE ASSOCIATED AIR BALANCE COUNCIL NATIONAL STANDARDS FOR FIELD MEASUREMENT AND INSTRUMENTATION, SECOND EDITION, 1974, OR NATIONAL ENVIRONMENTAL BALANCING BUREAU STANDARDS. 3. THE CONTRACTOR SHALL CORRECT ALL DEFICIENCIES IN THE OPERATION OF FACTORY SET VAV UNITS. 4. READINGS AND TEST OF DIFFUSERS, GRILLES AND REGISTERS SHALL INCLUDE DESIGN, INITIAL TEST, AND FINAL ADJUSTED FPM VELOCITY AND CFM. ALL DIFFUSERS, GRILLES AND REGISTERS SHALL BE BALANCED BY A HOOD THAT HAS BEEN CALIBRATED, INCLUDING A MANOMETER, AND PILOT TUBE READINGS SHALL BE TAKEN TO ESTABUSH TOTAL CFM FLOW IN ALL MAIN DUCTS. DIRECT READING INSTRUMENTS SUCH AS VELOMETERS AND ANEMOMETERS MAY BE USED AT TERMINAL UNITS. IV RECORDS FOR OWNER: A. CONTRACTOR SHALL KEEP A CLEAN SET OF DRAWINGS ON THE JOB, NOTING DAILY ALL CHANGES MADE IN THESE DRAWINGS IN CONNECTION WITH THE FINAL INSTALLATION INCLUDING EXACT DIMENSIONED LOCATIONS OF ALL NEW AND UNCOVERED EXISTING UTILITIES AND SHALL, WITH HIS REQUEST FOR FINAL PAYMENT, TURN OVER A CLEAN, NEATLY MARKED SET OF 2 MIL REPRODUCIBLE MYLARS SHOWING "AS INSTALLED" WORK TO THE ARCHITECT FOR SUBSEQUENT REVIEW AND TRANSMITTAL TO THE OWNER. CONTRACTOR SHALL NOTE ALL CONSTRUCTION CHANGES, DATE EACH SHEET AND LABEL "AS- BUILTS" IN THE REVISION BLOCK ON THE DRAWINGS. CONTRACTOR SHALL ALSO FURNISH ONE (1) SET OF BLUELINE PRINTS FROM THE "AS- BUILTS" MYLARS. B. IN ADDITION TO THE ABOVE, CONTRACTOR SHALL ACCUMULATE DURING THE JOB'S PROGRESS, THE FOLLOWING DATA, IN TRIPUCATE, PREPARED IN A NEAT BROCHURE OR PACKET FOLDER AND TURNED 5" OVER TO THE ARCHITECT FOR REVIEW AND SUBSEQUENT DEUVERY TO THE OWNER. 1. ALL WARRANTIES AND GUARANTEES AND MANUFACTURER'S D DIRECTIONS ON EQUIPMENT AND MATERIAL COVERED BY THE CONTRACT INCLUDING THE NAMES, ADDRESSES AND TELEPHONE NUMBERS OF THE MANUFACTURER'S REPRESENTATIVE. 2. APPROVED FIXTURE BROCHURES, WIRING DIAGRAMS AND CONTROL DIAGRAMS (ORIGINAL DATA, NO COPIES). 3. COPIES OF APPROVED SHOP DRAWINGS. 4. OPERATING INSTRUCTIONS FOR HEATING AND COOLING AND OTHER MECHANICAL SYSTEM. OPERATING INSTRUCTIONS SHALL ALSO INCLUDE RECOMMENDED MAINTENANCE AND SEASONAL CHANGEOVER PROCEDURES. 5. TEST AND BALANCE REPORTS REQUIRED BY THESE SPECIFICATIONS. 6. ANY AND ALL OTHER DATA AND /OR DRAWINGS REQUIRED DURING CONSTRUCTION. 7. REPAIR PARTS LISTS OF ALL MAJOR ITEMS AND EQUIPMENT INCLUDING NAME, ADDRESS AND TELEPHONE NUMBERS OF LOCAL SUPPLIER OR AGENT. F C. ALL OF THE ABOVE DATA SHALL BE SUBMITTED TO THE ENGINEER N FOR HIS REVIEW AT SUCH TIME AS THE CONTRACTOR SUBMITS HIS LAST ESTIMATE PRIOR TO HIS FINAL PAYMENT, BUT IN NO CASE, LESS THAN TWO WEEKS BEFORE FINAL INSPECTION. GENERAL MECHANICAL NOTES I RETURN AIR WILL BE TAKEN THROUGH LIGHT FIXTURES, PORTIONS OF PERIMETER SLOTS, AND RETURN AIR GRILLES. II CONTRACTOR TO VERIFY THAT ALL LIGHT FIXTURES HAVE SLOTS OPEN FOR AIR HANDLING CAPABILITIES. (BEND TABS IF REQUIRED.) III LOCATIONS AND SIZES OF EXISTING SYSTEMS ARE APPROXIMATE. EXACT SIZES AND LOCATIONS OF ALL EXISTING PIPING, DUCTS, ETC. SHALL BE VERIFIED ON THE JOB BY THE CONTRACTOR. IV CONTRACTOR SHALL INSTALL MECHANICAL SYSTEMS WITHOUT INTERFERENCE AND IN STRICT COORDINATION WITH ALL OTHER TRADES. HOLD DUCTWORK TIGHT AGAINST UNDERSIDE OF STRUCTURE ABOVE. V CFM DESIGNATION AT TERMINALS INDICATE PRIMARY AIR ON TOP AND FAN AIR ON BOTTOM. VI ALL DUCT SIZES ARE "AIR SIZE ". SHEET METAL TO BE INCREASED TO ACCOMMODATE DUCT LINER, IF APPLICABLE. VII TAPE AND SEAL ALL ROUND DUCT CONNECTIONS TO BE PERMANENTLY AIR TIGHT. VIII SPIN -IN COLLARS "ONLY" SHALL BE SUITABLE FOR CONNECTION TO RECTANGULAR DUCTWORK AND SHALL HAVE VOLUME DAMPERS. "DOVE -TAIL" TAPS WILL NOT BE ALLOWED. IX RIGID SHEET METAL DUCT SHALL BE RUN WITHIN SIX FEET OF DIFFUSERS. FLEX DUCT SHALL BE SUPPORTED AS OFTEN AS NECESSARY TO PREVENT KINKS, FOLDS OR OTHER OBSTRUCTIONS TO AIR FLOW. CEIUNG GRID AND ASSOCIATED SUPPORTS MAY NOT BE USED TO SUPPORT DUCTWORK. PROVIDE RIGID 90 DEGREE ELBOWS ON DIFFUSER NECKS. X EQUIPMENT CAPACITIES AND CHARACTERISTICS SHALL BE AS SCHEDULED ON THE DRAWINGS. XI EXISTING CEIUNG DIFFUSERS MAY BE REUSED AND RELOCATED AS NECESSARY UNLESS NOTED OTHERWISE OR SIZE PROHIBITS USE. XII NEW CEILING DIFFUSERS TO BE TITUS, METALAIRE OR KRUEGER AND SUIT THE SPECIFIED SERVICE AND CEILING TYPE UNLESS NOTED OTHERWISE ON PLANS. COORDINATE WITH ARCHITECTURAL PLANS. XIII CEILING RETURN AIR GRILLES SHALL BE TITUS, NAILOR, METALAIRE OR KRUEGER. XIV EXHAUST REGISTERS SHALL BE TITUS, NAILOR, METALAIRE OR KRUEGER XV THERMOSTATS FOR EXISTING TERMINAL BOXES ARE EXISTING AND SHALL BE INSTALLED WHERE SHOWN ON PLANS. (44" A.F.F. UNLESS NOTED OTHERWISE.) NEW THERMOSTATS SHALL BE EQUAL TO AND MATCH EXISTING THERMOSTATS. CALIBRATE ALL NEW AND EXISTING THERMOSTATS AT THE JOB COMPLETION. XVI EXHAUST FANS SHALL BE INSTALLED AS DETAILED ON THE DRAWINGS. XVII ALL NEW FLOOR PENETRATIONS AND PENETRATIONS THROUGH RATED WALLS SHALL BE FIRE SAFED. XVIII RE -POUR ALL ABANDONED FLOOR PENETRATIONS. XIX ALL DIFFUSERS AND SLOT SUPPLIES SHALL BE FURNISHED WITH SPIN -IN COLLAR. VOLUME DAMPER AND 6' OF FLEXIBLE DUCT. XX CONTRACTOR SHALL PREPARE AND SUBMIT FOR APPROVAL BY THE ENGINEER ALL MAJOR ITEMS OF MATERIALS AND EQUIPMENT. GENERAL FIRE PROTECTION NOTES XXI IT IS THE INTENT THAT THE FIRE PROTECTION SUB - CONTRACTOR BE RESPONSIBLE FOR THE DESIGN AND INSTALLATION OF THE FIRE SUPPRESSION SYSTEMS IN ACCORDANCE WITH APPLICABLE CODES. XXII FIRE PROTECTION SUB - CONTRACTOR SHALL UTILIZE EXISTING PIPING SYSTEM AND SPRINKLER HEADS WHERE POSSIBLE, AND ADD PIPING AND HEADS AS REQUIRED TO PROVIDE CODE APPROVED COVERAGE OR MATCH EXISTING BUILDING SPRINKLER GRID COVERAGE. XXIII SPRINKLER HEADS TO MATCH EXISTING HEADS WITHIN THE BUILDING. XXIV COORDINATE HEAD LOCATIONS WITH LIGHT FIXTURES, DIFFUSERS, GRILLES, ETC. GENERAL PLUMBING NOTES XXV LOCATIONS AND SIZES OF EXISTING SYSTEMS ARE APPROXIMATE. EXACT SIZES AND LOCATIONS OF EXISTING SYSTEMS TO BE UTIUZED SHALL BE VERIFIED AT JOB SITE. XXVI SEAL AROUND ALL PIPE PENETRATIONS THROUGH FLOORS WITH WATER PROOFING AND FIRE -SAFE MATERIALS. XXVII REMOVE ALL EXISTING ABANDONED PLUMBING PIPING, FITTINGS AND CAP AT STACKS. XXVIII RE -POUR ALL ABANDONED FLOOR PENETRATIONS. XXIX CONTRACTOR SHALL PREPARE AND SUBMIT FOR APPROVAL BY THE ENGINEER ALL MAJOR ITEMS OF MATERIALS AND EQUIPMENT. FLEXIBLE CONECTION, TYPICAL AI FLOW W INTAKE DUCT,SEE PLANS FOR SIZE. �2IN -LINE NO song Project #:412469.000 2121 Ponce de Leon eo,ijavard Suite 350 Coral Gables, FL 33134 phone: 305.569.1692 fax: 305.569.1693 Professional Consulting Engineers Austin • Dallas . Denver . Houston . Kansas City . Miami Nashville . Phoenix . Richmond • Washingtor• D C. EB00007658 1/2" ALL THREADED STEEL HANGER ROD, SECURE TO STRUCTURE WITH DOUBLE NUTS,TYPICAL(MIN. OF 4). STEEL SPRING VIBRATION ISOLATOR, TYPICAL (MIN. 4) DISCONNECT MOTOR COVER MOTOR BELT BACKDRAFT DAM X DISCHARGE DUCT PER,SEE SCHEDULE FOR TYPE. SEE PLANS FOR SIZE. CENTRIFUGAL FAN DETAIL 22x18 16x16 18 2208 2414 ao `O o x N CC FAN FAN PLENUM CEILING a a z 18 z 19 NEOPRENE PAD (MASON IND. SUPER WIC HOUSEKEEPING PAD NO SCALE 18x26x4O PLENUM RETURN PLENUM (TYPICAL) CONTRACTOR SHALL SIZE RETURN PLENUM FULL SIZE WITH RETURN OPENING OF UNIT ELEVATION I I A L^� (i 0 M in z� L �z V � x0 V w z x� Ln V F < H a ;2 04 �tl. r, O w 4.0 V Q � 16 O -- z H O Q r.1 V V za x V W � PERIIIMT SET ORAWNr RR I CIRCIM LEN QATRI 1-23 -2012 IWAIA AS Sheet No. M7.03 I JM f 20113-1 I r0 't jvo l A 11 Z7 M NU L INEE R A •J�A"b.i ...a. �A.4• Sheet No. M7.03 I JM f 20113-1 I