13-185-013FAfRTIAL ELEVATION
SCALE: 3/8" = P-O'
EXISTING TO REMAIN.
SECONp
EL. = 10' -�"
EXISTING INTAKE FAN
TO BE REPLACED.
EL, = 0' -O"
FINISH GROUND FL,
Xf 3TiN
FAfRTIAL ELEVATION
&CALE: 3/8" = V -0"
S CT I CN 114_411
5G,ALE. 3/8" = V -0"
SECOND
EL. = 10' -(o °
EL. = O' -O"
EXISTING TO REMAIN.
FINISH GROUND FL.
I iI 1
REMOVE EXISTING I 1
CONDEN51NCx UNIT AND LINE_ I I I I
PATCH HOLES AND MATCH TO I I I
EXISTING FINISH. �1 1
SAW CUT NEW OPENING IN EXISTING BLOCK WALL AS 5HOWK
TIGHT TO EXISTING BEAM ABOVE FOR NEW LOUVER_ CONFLICT
BETWEEN DUCTWORK /PLENUM AND EXISTING CEILING SHOULD BE
BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE CUTTING
,- ING O AIN.
t•• � -r,'4" Jr ,•r.. - r•.•t� «3M•• •••�•. .'L•� j•� r�•t• .'�• •�.. .•�• � •r' i .�i. -.i• � �..:..f _,:♦,�'�.•�
COOi;P-DINATE LOCATION OF DUCT,
AROUND EXISTING RWL. ROUTE IN WALL.
- -- LOCATION OF NEW OFENING FOR DUCT
PENETRATIONS. SEAL ALL OPENINGS
WITH SOUND ATTENUATION (5TC &0).
PORTION OF CEILING TO BE
REPLACED AND RAISED TO
MATCH EXISTING -1' -8"
HEIGHT,
EXISTING 8"
BLOCK WALL
BOTTOM OF
EXISTING BEAM
—EXISTING PACKAGE UNIT TO
BE REMOVED. EXISTING
OPENING TO REMAIN FOR NEW
EXHAUST FAN.
A.
X15TN CONC. L.AB
— EXISTING
CEILING TO
REMAIN
DINING
ROOM
ICI
EXISTING CONC. SLAB
Ll
/
/
-t-- 3'
all 41-411
EXISTING
HOSF''ITAL
PROJECT AREA
AT FIRST FLOOR
--
1301V
INDICATES GYPSUM BOARD
HEADER OVER OPENING
INDICATES GYPSUM BOARD
SOFFIT OR CEILING
INDICATES ACOUSTICAL
TILE CEILING SYSTEM.
FLUORESCENT LIGHT FIXTURE
CEILING MOUNTED
CAMERA
PARABOLIC FLUORESCENT
-
LIGHT FIXTURE
FLUORE5CENT LIGHT STRIP
O
RECE55ED LIGHT FIXTURE
(HATCHING DENOTES DIRECTIONA
L IGHT)
WALL MOUNTED LIGHT FIXTURE AND
(+ 80" A,F,F
ELEVATION ABOVE FINISH FLOOR
O
SPRINKLER HEAD
(SEE FIRE PROTECTION DRAWING5)
WALL MOUNTED SPRINKLER HEAD
(SEE FIRE PROTECTION DRAWINGS)
®
EXIT LIGHT
(HATCH DENOTES LIGHTED FACE)
(SEE ELECTRICAL DRAWINGS)
DIRECTIONAL EXIT LIGHT
®�
(HATCH DENOTES LIGHTED FACE)
(SEE ELECTRICAL DRAWINGS)
A/C SUPPLY DIFFUSER
(SEE MECHANICAL DRAWING5)
A/C RETURN GRILLE
(SEE MECHANICAL DRAWINGS)
ElCEILING
ACCESS PANEL
(HATCHING MARKS
(HATCHING DENOTES NEW)
(UNHATCHED DENOTES EXISTING)
1
SOFFIT DETAIL SYMBOL
A -12
W1 DRAWING AND SHEET NUM3ER5
CEILING MOUNTED
CAMERA
CEILING MOUNTED
SD
SMOKE DETECTOR
CEILING MOUNTED
1T1
111
HEAT DETECTOR
SP
CEILING MOUNTED
SPEAKER
REVISION SYMBOL
3
(REFER TO COVER SHEET
FOR REVISION INFORMATION)
NURSE CALL DOME LIGHT,
CEILING MOUNTED.
PROJECT AREA
AT FIRST FLOOR
--
1301V
r°
Revisivni:
0 I
1/4/13
AI-ICA
GOMMENT5
A
A
A
A
� a �
a �
�I
�z
V �
x0
z V
wz
4
V
r�nM
O
�V
164
�A
Z
o<
<z
w -
w V w
W -4 �
O
0 0 zz
~o
w
�w
W V)
PERMIT SET
DRAWN: RCS
CHECKEMCd?WENT5
DATE: 1 -23 -2012
SCALE: A5 SHOUJN
Sheet No.
A -3
OF
7
„108 0 20113 -1 1