Loading...
13-185-013FAfRTIAL ELEVATION SCALE: 3/8" = P-O' EXISTING TO REMAIN. SECONp EL. = 10' -�" EXISTING INTAKE FAN TO BE REPLACED. EL, = 0' -O" FINISH GROUND FL, Xf 3TiN FAfRTIAL ELEVATION &CALE: 3/8" = V -0" S CT I CN 114_411 5G,ALE. 3/8" = V -0" SECOND EL. = 10' -(o ° EL. = O' -O" EXISTING TO REMAIN. FINISH GROUND FL. I iI 1 REMOVE EXISTING I 1 CONDEN51NCx UNIT AND LINE_ I I I I PATCH HOLES AND MATCH TO I I I EXISTING FINISH. �1 1 SAW CUT NEW OPENING IN EXISTING BLOCK WALL AS 5HOWK TIGHT TO EXISTING BEAM ABOVE FOR NEW LOUVER_ CONFLICT BETWEEN DUCTWORK /PLENUM AND EXISTING CEILING SHOULD BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE CUTTING ,- ING O AIN. t•• � -r,'4" Jr ,•r.. - r•.•t� «3M•• •••�•. .'L•� j•� r�•t• .'�• •�.. .•�• � •r' i .�i. -.i• � �..:..f _,:♦,�'�.•� COOi;P-DINATE LOCATION OF DUCT, AROUND EXISTING RWL. ROUTE IN WALL. - -- LOCATION OF NEW OFENING FOR DUCT PENETRATIONS. SEAL ALL OPENINGS WITH SOUND ATTENUATION (5TC &0). PORTION OF CEILING TO BE REPLACED AND RAISED TO MATCH EXISTING -1' -8" HEIGHT, EXISTING 8" BLOCK WALL BOTTOM OF EXISTING BEAM —EXISTING PACKAGE UNIT TO BE REMOVED. EXISTING OPENING TO REMAIN FOR NEW EXHAUST FAN. A. X15TN CONC. L.AB — EXISTING CEILING TO REMAIN DINING ROOM ICI EXISTING CONC. SLAB Ll / / -t-- 3' all 41-411 EXISTING HOSF''ITAL PROJECT AREA AT FIRST FLOOR -- 1301V INDICATES GYPSUM BOARD HEADER OVER OPENING INDICATES GYPSUM BOARD SOFFIT OR CEILING INDICATES ACOUSTICAL TILE CEILING SYSTEM. FLUORESCENT LIGHT FIXTURE CEILING MOUNTED CAMERA PARABOLIC FLUORESCENT - LIGHT FIXTURE FLUORE5CENT LIGHT STRIP O RECE55ED LIGHT FIXTURE (HATCHING DENOTES DIRECTIONA L IGHT) WALL MOUNTED LIGHT FIXTURE AND (+ 80" A,F,F ELEVATION ABOVE FINISH FLOOR O SPRINKLER HEAD (SEE FIRE PROTECTION DRAWING5) WALL MOUNTED SPRINKLER HEAD (SEE FIRE PROTECTION DRAWINGS) ® EXIT LIGHT (HATCH DENOTES LIGHTED FACE) (SEE ELECTRICAL DRAWINGS) DIRECTIONAL EXIT LIGHT ®� (HATCH DENOTES LIGHTED FACE) (SEE ELECTRICAL DRAWINGS) A/C SUPPLY DIFFUSER (SEE MECHANICAL DRAWING5) A/C RETURN GRILLE (SEE MECHANICAL DRAWINGS) ElCEILING ACCESS PANEL (HATCHING MARKS (HATCHING DENOTES NEW) (UNHATCHED DENOTES EXISTING) 1 SOFFIT DETAIL SYMBOL A -12 W1 DRAWING AND SHEET NUM3ER5 CEILING MOUNTED CAMERA CEILING MOUNTED SD SMOKE DETECTOR CEILING MOUNTED 1T1 111 HEAT DETECTOR SP CEILING MOUNTED SPEAKER REVISION SYMBOL 3 (REFER TO COVER SHEET FOR REVISION INFORMATION) NURSE CALL DOME LIGHT, CEILING MOUNTED. PROJECT AREA AT FIRST FLOOR -- 1301V r° Revisivni: 0 I 1/4/13 AI-ICA GOMMENT5 A A A A � a � a � �I �z V � x0 z V wz 4 V r�nM O �V 164 �A Z o< <z w - w V w W -4 � O 0 0 zz ~o w �w W V) PERMIT SET DRAWN: RCS CHECKEMCd?WENT5 DATE: 1 -23 -2012 SCALE: A5 SHOUJN Sheet No. A -3 OF 7 „108 0 20113 -1 1