13-185-010S _
r -
FL00 AN
SCALE= 311ro" = V-0" NORTH
FL.00 FLAN LEGE 1F,)
RG
ONE HOUR FIRE RATED
_
WALL OR PARTITION
1-23-2012
(SEE PARTITION TYPES)
INDICATES GYPSUM BOARD
ONE HOUR FIRE / 5MOKE RATED
—
WALL OR PARTITION
(SEE PARTITION TYPES)
TWO HOUR FIRE /SMOKE RATED
INDICATES ACOUSTICAL
WALL OR PARTITION
TILE CEILING 6Y5TEM.
(SEE PARTITION TYPES)
5MOKE PARTITION
(SEE PARTITION TYPES)
Hm
NEW REINFORCED CONCRETE
COLUMN OR CONCRETE WALL
(SEE ARCH. 4 STRUCTURAL PLANS)
NEU) CONCRETE BLOCK WALL
PARA50LIC FLUORESCENT
(SEE FLOOR PLANS)
NEW METAL STUD PARTITION
(SEE FLOOR PLANS AND
(PARTITION TYPE DETAILS)
.
EXISTING REINFORCED GONG,
COLUMN OR CONCRETE WALL
O
(5EE F OOR PLANS)
EXISTING WALL OR
PARTITION TO REMAIN
CTI
WALL OR PARTITION
ELEVATION ABOVE FINISH FLOOR
WITH NEW DOOR AND DOOR NUMBE
(COORDINATE W1 DOOR SCHEDULE)
"
NOTE:
(SEE FIRE PROTECTION DRAWINGS)
BROKEN LINE DOOR INDICATE
.'
DOUBLE ACTING DOOR
(SEE FIRE PROTECTION DRAWINC:S)
WALL OR PARTITION WITH
EXIT LIGHT
(HATCH DENOTES LIGHTED FACE)
EXISTING DOOR TO REMAIN
(SEE ELECTRICAL DRAWINGS)
INDICATES
NEW FOLDING PARTITION
aaoon
1234
ROOM NUMBER SYMBOL
(REFER TO ROOM FINISH SCHEDULE
STOREFRONT / WINDOW OR
�p
O
BORROWED LIGHT SYMBOL
®
(SEE ELEVATIONS)
A/C SUPPLY DIFFUSER
LOUVER 5YMeOL
(SEE ELEVATIONS)
(SEE MECHANICAL DRAWINGS)
CABINET SYMBOL
(SEE ELEVATIONS)
A/C RETURN GRILLE
PARTITION TYPES SYMBOL
(REFER TO PARTITION
(SEE MECHANICAL DRAWINGS)
TYPE DETAILS AND NOTES)
ACCESS PANEL
INTERIOR ELEVATION 5YM50L
1
(SEE INTERIOR ELEVATIONS)
(UNHATCHED DENOTES EXISTING)
ELEVATION MARKS
(HATCHING DENOTES NEW)
SOFFIT DETAIL SYMBOL
(UNHATCHED DENOTES EXISTING)
A( 1
SECTION SYMBOL
A-
W1 DRAWING AND SHEET NUMBERS
I
DETAIL SYMBOL
A-
W1 DRAWING AND SHEET NUMBERS
SMOKE DETECTOR
REVISION SYMBOL
a�
(REFER 70 COVER SHEET
HEAT DETECTOR
FOR REVISION INFORMATION)
CEILING MOUNTED
OUT OF SCOPE OF WORK
NOTE:
NOT ALL SYMBOLS ARE APPLIGABLE.
NOTES-
1. CONTRACTOR TO SAW CUT BLOCK
WALL AS REaUlf2ED.
FlfP,5T f=LCCfP,, FLAN -
SCALE: 3 /fro" = 1'_0" NORTH
CEILING FLAl l LEGEND
RG
INDICATES GYP5UM BOARD
HEADER OVER OPENING
LEN
DATE:
1-23-2012
SCALE:
INDICATES GYPSUM BOARD
SOFFIT OR CEILING
INDICATES ACOUSTICAL
TILE CEILING 6Y5TEM.
FLUORESCENT LIGHT FIXTURE
CEILING= MOUNTED
Hm
CAMERA
EED
PARA50LIC FLUORESCENT
LIGHT FIXTURE
FLUORESCENT LIGHT STRIP
O
RECESSED LIGHT FIXTURE
(HATCHING DENOTES DIRECTIONAL
LIGHT)
WALL MOUNTED LIGHT FIXTURE AND
ELEVATION ABOVE FINISH FLOOR
�+ 80 A
O
SPRINKLER HEAD
(SEE FIRE PROTECTION DRAWINGS)
n
WALL MOUNTED SPRINKLER HEAD
l�J
(SEE FIRE PROTECTION DRAWINC:S)
®
EXIT LIGHT
(HATCH DENOTES LIGHTED FACE)
(SEE ELECTRICAL DRAWINGS)
DIRECTIONAL EXIT LIGHT
(HATCH DENOTES LIGHTED FACE)
(SEE ELECTRICAL DRAWINGS)
®
A/C SUPPLY DIFFUSER
(SEE MECHANICAL DRAWINGS)
A/C RETURN GRILLE
(SEE MECHANICAL DRAWINGS)
ElCEILING
ACCESS PANEL
ELEVATION MARKS
(HATCHING DENOTES NEW)
(UNHATCHED DENOTES EXISTING)
SOFFIT DETAIL SYMBOL
A -12
W1 DRAWING AND SHEET NUMBERS
CEILING MOUNTED
4
CAMERA
CEILING MOUNTED
rjp
SMOKE DETECTOR
CEILING MOUNTED
1--1D
HEAT DETECTOR
CEILING MOUNTED
SPEAKER
REVISION SYMBOL
CREFER TO COVER SHEET
(REFS
3
FOR RF-VI51ON INFORMATION)
NURSE CALL DOME LIGHT,
CEILING MOUNTED.
MI'NM
'R 11H I
i
KEY PLAN
PROJECT AREA
AT FIRST FLOOR
SW 61ST: COURT
S. W. 62ND AVE.
NORTH
N.T.S.
Revisions:
1/4/13
COMMENTS
2/1/13, 1
a
c" gin
z '
w H
� a
a �
1�1
�z
V �
x0
W z
N
W
El
x�.
0
V-
0
zw
O
< V Z
z
OV
O Iw A
w w
E- Q
Q Q
A'' . j
a �
PERMIT SET
DRAWN:
RG
CHECKED:
LEN
DATE:
1-23-2012
SCALE:
AS SHOWN
SEA` X.
Sheet No
A -2
OF
7
I JOB * 20113-1
Sheet No
A -2
OF
7
I JOB * 20113-1