13-185-002IKITCHEN HVAC REPLACEMENT L A R K I N L A R K I N i- 0 w, r H 0 - I T A L 7031 S.W. 62nd AVE SOUTH MIAMI FLORIDA 33143 TEL: (305) 284 - 7500. FAX: (305) 284 -7545 PERMIT SET AHCA CLIENT CODE /FILE - PROJECT SUB NUMBER: 23/100181 -120 -1 JULY 23, 2012 GENERAL NOTES I. CONTRACTOR IS BEING PROVIDED WITH COMPLETE SETS OF DOCUMENTS. CONTRACTOR IS RESPONSIBLE FOR PROVIDING SUBCONTRACTORS WITH COMPLETE SETS OF DRAWINGS, INTENT IS FOR ALL SYSTEMS AND EQUIPMENTS TO BE PROVIDED WITH UTILITY CONNECTIONS AS REQUIRED FOR OPERATION, EXAMPLE; IF A SINK IS SHOWN IN THE ARCHITECTURAL PLANS, AND THE PLUMBING PLANS DO NOT SHOW A WATER OR DRAWING CONNECTION, THE ENGINEER WILL PROVIDE THE DESIGN DETAILS IN ACCORDANCE WITH THE DESIGN CRITERIA FOR THE REST OF THE INSTALLATION. CONTRACTOR IS RESPONSIBLE FOR PROVIDING THE CONNECTION AT NO ADDITIONAL COST TO THE OWNER. 2. CONTRACTOR IS RESPONSIBLE FOR VISITING THE SITE DURING THE BIDDING PERIOD, AND VERIFY THAT CONDITIONS ARE AS DESCRIBED IN THE DOCUMENTS. DISCREPANCIES ARE TO BE NOTED IN WRITING, AND ARCHITECT /ENGINEERS, NOTIFIED. CONTRACTOR ACCEPTS CONDITIONS AS THEY ARE ON THE SITE, AND MUST PROVIDE SYSTEMS AND WORK, AS DESCRIBED IN THE CONTRACT DOCUMENTS AT NO ADDITIONAL COST TO THE OWNER. 3. DIMENSIONS PROVIDED ARE NOMINAL NOT ACTUAL. THEY TAKE AS A BASIS EXISTING WALLS, IF DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT IMMEDIATELY FOR COORDINATION, IF CONTRACTOR PROCEEDS, HE DOES SO AT HIS OWN RISK, AND IS RESPONSIBLE FOR ALL EXPENSES INCURRED, IF AT THE DISCRETION OF THE OWNER OR THE ARCHITECT THE WORK HAS TO BE RE -DONE. A SHUTDOWN OF UTILITIES; IF A SHUTDOWN OR ANY TYPE OF INTERFERENCE WITH EXISTING SYSTEMS IS ANTICIPATED, THE CONTRACTOR MUST NOTIFY THE OWNER 72 HOURS IN ADVANCE, AND OBTAIN APPROVAL IN WRITING PRIOR TO PROCEEDING. 5. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS, AND USE ALL APPROPRIATE CONSTRUCTION METHODS /TECHNIQUES TO PROTECT EXISTING UTILITIES AND OTHER PROPERTY NOT NOTED FOR REMOVAL, CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGES INCURRED DURING CONSTRUCTION, AND SHALL REPAIR ANY DAMAGES AT NO EXPENSE TO THE OWNER. 6. IF THERE IS A DISCREPANCY BETWEEN THE DRAWINGS AND THE SPECIFICATIONS, THE CONTRACTOR SHALL OBTAIN CLARIFICATIONS DURING THE BIDDING PERIOD. IF THE DISCREPANCY COMES UP DURING THE CONSTRUCTION, IT IS ASSUMED THE CONTRACTOR BID AS THE MOST EXPENSIVE WAY, AND WILL DO THE WORK AS PER THE DIRECTIONS OF THE OWNER / ARCHITECT AT NO ADDITIONAL COST TO THE OWNER. 7, ABBREVIATIONS THROUGHOUT THE PLANS ARE THOSE IN COMMON USE. ARCHITECT WILL DEFINE INTENT OF ANY IN QUESTION. 8. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY TEMPORARY BARRIERS, LIGHTING, COVERINGS, FIRE PREVENTION AND OTHER EQUIPMENTS TO PROTECT THE SAFETY OF ALL PERSONS AND THE PROPERTY THROUGHOUT THE ENTIRE PERIOD OF THE CONSTRUCTION - CONTRACT. 9. THE CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS OF ALL OPENINGS FOR MECHANICAL, ELECTRICAL AND PLUMBING EQUIPMENTS WITH SUBCONTRACTORS, AS WELL AS SHOP DRAWINGS AS APPROVED BY ARCHITECT, BEFORE PROCEEDING WITH THE WORK. 10. ALL ITEMS USED IN CONSTRUCTION, BUT NOT SPECIFICALLY MENTIONED HEREIN, SHALL CONFORM TO ALL LOCAL CODES AND STATE ORDINANCES AS TO APPLICATION AND USE. 11, PROVIDE ELECTRIC INSULATION BETWEEN ALL DISSIMILAR METALS AND ALSO BETWEEN CEMENT AND METAL. 12, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS TO COMPLETE THE PROJECT. 13. CONTRACTOR TO REVIEW ALL EXISTING BUILDING SYSTEMS, AS TO THEIR COMPLIANCE WITH ALL LOCAL AGENCY REQUIREMENTS, AND BRING ANY NON - CONFORMING ITEMS TO ARCHITECT'S AND ENGINEER'S ATTENTION. 14, GENERAL CONTRACTOR IS TO PROTECT EXISTING ADJACENT AREAS WHERE WORK IS TO BE PERFORMED. ANY EXISTING MILLWORK OR EQUIPMENT DAMAGED DUE TO WORK PERFORMED, SHALL BE REPAIRED /REPLACED TO MATCH EXISTING (TYPICAL UNLESS OTHERWISE NOTED). 15, DRAWINGS ARE SCHEMATIC, SHOWING RELATIVE LOCATIONS AND CONNECTIONS, AND SHALL NOT BE SCALED AT ANY TIME. 16. ALL WOOD BLOCKING WITHIN BUILDING STRUCTURE, SHALL BE FIRE- RETARDANT TREATED AS PER SPECIFICATIONS. 17. GENERAL CONTRACTOR SHALL INSPECT ALL EXISTING RATED WALLS /PARTITIONS WITHIN SCOPE OF WORK AREA. CONTRACTOR SHALL UPGRADE EXISTING PARTITIONS AS REQUIRED TO MAINTAIN THE INTEGRITY OF THE DESIGNATED RATING. 18. ELEVATIONS AND LEVELS; A, ALL NUMERICAL ELEVATIONS ARE TO TOP OF CONCRETE SLAB. UNLESS NOTED OTHERWISE. 19, ALL INTERIOR GYPSUM WALL BOARDS ARE 5/8" TYPE "X" G.W.B. ON METAL STUDS OR FURRING CHANNELS, UNLESS NOTED OTHERWISE. SIZES AS DIMENSIONED ON FLOOR PLANS. SEE NOTE NUMBER "9'r FOR LOCATION OF WATER RESISTANT G.W.B. 20. PROVIDE WATER RESISTANT TYPE "X" G.W.B. IN ALL TOILETS AND JANITOR'S CLOSETS. 21. BEFORE PATCHING ANY FIRE -RATED C.M.U. PARTITION, FILL ANY EXPOSED CELLS SOLID WITH GROUT. 22. PROVIDE FINISH WALL UNDER AND BEHIND ALL EQUIPMENTS AND CASE WORK. 23. LOCATION AND SIZE OF CEILING AND WALL ACCESS PANELS SHALL BE DETERMINED BY THE POSITION OF VALVES AND OTHER MECHANICAL AND ELECTRICAL ITEMS WHICH REQUIRE ACCESS. THE CONTRACTOR SHALL COORDINATE WITH ALL TRADES. THE ARCHITECT SHALL REVIEW AND APPROVE ALL FINAL LOCATIONS OF ACCESS PANELS PRIOR TO INSTALLATION. 24. THERE SHALL BE NO BACK- TO-BACK ELECTRICAL TELEPHONE OR OTHER OUTLETS. 25. ALL VERTICAL PIPING AND COLUMNS EXPOSED IN ROOMS, SHALL BE FURRED WITH METAL STUDS AND DRY WALL, AND FINISHED TO MATCH ADJACENT WALLS, U.N.O. EXCEPTIONS A. ELECTRIC CLOSETS C. MECHANICAL ROOMS B. TELEPHONE CLOSETS D. STAIRS 26. WHERE C RE VA OR OTHER MECHANICAL, ELECTRICAL AND PLUMBING ITEMS PENETRATE PARTITIONS, STUDS SHALL BE BRACED AND FRAMED TO STRUCTURE, AS REQUIRED TO PROVIDE ADEQUATE SUPPORTS. ALL PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED TO PROVIDE FIRE, SMOKE AND /OR ACOUSTICAL ISOLATION OF SPACES WITH APPROPRIATE FIRE S.T.C. MATERIAL. 27. SEE INTERIOR ELEVATIONS FOR FINISHES AND FINISH DETAILS FOR INTERIOR SPACES. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR ACOUSTICAL TILE FINISH. 28. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATION OF CEILING - MOUNTED MECHANICAL /ELECTRICAL FIXTURES. 29, STAGGER JOINTS VERTICALLY AND HORIZONTALLY IN ALL G.W.B. PARTITIONS, EACH SIDE, JOINTS STAGGERED MINIMUM 2' -O" U.O.N, 30. CONTRACTOR SHALL CONFIRM THAT ALL EXISTING EXPOSED STEEL COMPLIES WITH N.F,P,A, FIRE PROTECTION REQUIREMENTS. CONTRACTOR SHALL PROVIDE ALL NECESSARY INSULATION /FIRE PROTECTIVE COATINGS. 31. CONTRACTOR TO SUBMIT ALL SHOP DRAWINGS TO ARCHITECT AND THE BUILDING DEPARTMENT FOR APPROVAL. (ELEVATOR, TRUSSES, WINDOWS, ETC.) 32. CONTRACTOR REQUIRED TO PULL SEPARATE DEMOLITION PERMIT. w 2121 Ponce de Leon Blvd., Suite 350 Coral Gables, FL 33134 Professional Consulting Engineers phone: 305.569.1692 f ax: 305.569.1693 Dallas., Houston . Nashville • Miami . Richmond ccrd project number: O 0 D O architect s FLORIDA LICENSE *AA0002689 2100 Ponce de Leon Blvd. Suite 1170, Coral Gables, Florida 33134 Tel: (305)265 -7177 Fax: (305)262 -8435 EB00007658 PR0 JECT NUMBER: 201137 LUIS E. NAPA_ A_i_A FI_ ARnnnRnAA CITY MAP , ;$.. 4' ';� & a .,.�$,.. f � ' i;z '; a• $$ a ,�.I,; ,re. 'a3 r^� `r,'�'^;. ?ue � �,'t",- '� �.4y �'4Y'iF� }r� 9 �" .� ,:� {' :�i rtw f F. :4 {'k��•},k �',r'�F.k f � v.� a >< t� t,: x ix a �i , y. ". ✓>-. '2 � rP *���,, a � £ -,, qqS p t e ! �x s ,.' «s t! 'x � i� ��" � ,:�L��� !r%eti' � �� -S.,h.,• ?w✓aR..P ^t,♦;}. tfs 3 ,�,,� `"'�"i'a';'r,- ��.bi rr •s..?�s,r, �� •t' t iil �i'z 73 '..+s 'd � rr •� rr;'� v �` > � :. € "� k e�:'�:::cx! "'`' .;:{ �x,x�6_�Sr$a'`i'.z�,t�f,�• ! � � ,rr� �:5 r` R� -:x %} $ �€ �{� 8� * ? ✓,��� k '.+ i� }`5' z �:��4F wk�i'S11i �,rr..!%1���L"v�il�°�4a��3$ '�.. x.: ,fn „• $�� � z. �I,..,v � ,f ,s;,.t rj.0 y^� t f 5 "'�} L c �1' '�• �,,fg, r� 4Sts r T kG {F ff tt p w Y- i,,t 3 � ipx,l k� 5 'PS e T 3} I* ,w 45 5e +'br k�#e4f3 I" i Fsd a' "i` �e'` 1 er s j �.^ � 3� eta ",r'�li�)tlllt+�it�f ate, ,� .>z� «$�rt9����' : ^} r r s � af: sa� - -� a•;x; i`} +: k .t,:. n � � w �, s r t# .pyr+" € ; t��"""i,�,kFdi' fi:t { "?���� `' •, �`�� � a1'4. �� $ 41,'" x � c � � f ,4F `� °P'. ,5. t: � ?✓' { ,:nar%: � P <e 'j� a -'id a? �{ %i r¢ �� 1� t f, ,.dr., "�x �' 1{� � 99 � #4 `' I• iy, + a s �",s'+• r ,i$ �� a f a, ,{ r � dd � rr i `; #} > r� P (P i• CF's k jy� 3. t5',�i p rf �t yy,�t; sa,•�,f,i� 6Y,pE �W���,�{ gg>.N p a r�y�Nt�'"t'1 5L. }Y'`t�i `x i'i1 ��i��SJi;_ �� €: -: �. � r ��. q ex ^�r�� t$'Ti...cS d•.; w2 NV i(# Y , 'a ,'�$x , 5 S h u s CPi CC@@ i' ��iWi15700ii �r AREA MAP gy 9 `` ',`� � qggq •�,�� ,.�z# g7„ay ..a1.',,�'�`�� „ 'r,- 5':^ ti v r i �w�� rg ,.•�'f "e, i ';s �..� a� r s �.�s�tiii�P.���s.�f�'tli ;:: a. xq✓. >, a�. x� , 4. e x 9 t A; 4. t C ? � C�YM1,� 1 Vlf �,�W- �t�* .� � 7YS t �'# {#� �t,�'. " � F k: .�Z � y d 5,5 ur tt ) ,� r9 �E 5 4 %..,:.� s •'�F .Y M1i PROJECT 'SITE �Y�� { 9 k {{ a .-m � :':$ ,a,�:' 'x #:{ayq,,, yp':.L i}v^Ayi,,��'r•(�yy(�,*b ;as�- .w:.�+; A v;::,> ., .:,, . ;.:.. ,, _..,: .U. .:, :;, •% . 3,•:: ....,fey ...,.:..,.,,:.w ..e._: :.. ,...: w rr .,. -... „,, :. _,.. .... - :5 4d a � r i .vo �' .�.8�41� A.y4 r.�l wYR. } ^s`f[< hFk x w %�r•�"aa :rk P�yl d �.� � �y�$'�."`� �?;*;. £ Pa t,w � � s' �� 1 a •- I. � � � - .x�yi>��'k k `1�, r3'$�T �IT� h��h,F ;. E ":�:,_ �r" Y:�tt' ''�• 11,,:' �p ,�;. ::: r }',r��.,_ ' v�( ;t ddd ^rot�a ��,�aa�°tArtV r�✓'� a� 6 r �� t�ir .a �Y. a r ,s INDEX OF LIFE SAFETY LS -1 FIRST FLOOR LIFE SAFETY PLAN. DRAWINGS ARCHITECTURAL PLUMBING SP -1 SITE PLAN - FOR REFERENCE USE ONLY. NO PLUMBING IS REQUIRED IN THIS PROJECT - DETAILS AND ALL IS EXISTING TO REMAIN. A -1 DEMOLITION, LEGEND AND DETAILS. FLOOR DEMOLITION PLAN AND DISCIPLINE. A -2 PROPOSED FLOOR PLAN AND CEILING PLAN, LEGEND AND NOTES. GENERAL A -3 SECTIONS, LEGEND AND NOTES. FIRE PROTECTION A -4 DOOR SCHEDULE AND DETAILS GENERAL NOTES A -5 PENETRATION AND FIRE RATING DETAILS. NO FIRE PROTECTION IS REQUIRED IN THIS PROJECT - A -6 PENETRATION AND FIRE RATING DETAILS. ALL IS EXISTING TO REMAIN. A -7 PENETRATION AND FIRE RATING DETAILS, DISCIPLINE. JB MECHANICAL M -0.00 GENERAL INFORMATION MECHANICAL. MD -2.01 PARTIAL FIRST FLOOR DEMOLITION PLAN MECHANICAL. M -2.01 PARTIAL FIRST FLOOR NEW WORK PLAN MECHANICAL. M -3.01 PARTIAL FIRST FLOOR PIPING AND CONTROLS MECHANICAL. M -7.01 MECHANICAL DETAILS. M -7.02 MECHANICAL DETAILS. M -7.03 MECHANICAL DETAILS AND SPECIFICATIONS. M -8.01 MECHANICAL SCHEDULES. M -9.01 MECHANICAL CONTROLS. M -ICRA PARTIAL FIRST FLOOR MECHANICAL ICRA PLAN ELECTRICAL E -0.01 GENERAL NOTES SCHEDULES DETAILS AND DISCIPLINE. ED -2.01 PARTIAL FIRST FLOOR DEMOLITION PLAN AND DISCIPLINE. E -2.01 PARTIAL FIRST FLOOR NEW WORK PLAN AND DISCIPLINE. E -3.00 GENERAL NOTES SCHEDULES DETAILS AND DISCIPLINE. E -4.00 GENERAL NOTES SCHEDULES DETAILS AND DISCIPLINE. E -5.00 GENERAL NOTES SCHEDULES DETAILS AND DISCIPLINE. BUILDING INFORMATION ORIGINAL BUILDING DESCRIPTION BUILDING JURISDICTION : SOUTH MIAMI PRIMARY USE CLASS : HEALTH CARE. CONSTRUCTION TYPE (NFPA) : TYPE I (332) CONSTRUCTION TYPE : TYPE I FLORIDA BUILDING CODE NUMBER OF STORIES : 55' -O" [FIVE STORIES]. ALLOWABLE AREA : NOT LIMITED NEW PROJECT DESCRIPTION PROJECT AREA: : 2690 SQ. FT. SPRINKLERED: : FULLY SPRINKLED. APPLICABLE CODES • FLORIDA BUILDING CODE 2010. • FLORIDA FIRE PREVENTION CODE 2009 EDITION. • NFPA 101 LIFE SAFETY CODE, 2010 EDITION. (CHAPTER 18 NEW HEALTHCARE). • AIA GUIDELINES FOR DESIGN AND CONSTRUCTION OF HEALTH CARE FACILITIES 2010 EDITION. REVISIONS ABBREVIATIONS ARCHITECTURAL. A55REVIATIONS: WORKING 4 AND L ANGLE 1@ AT C CENTERING O DIAMETER ID INSIDE DIAMETER C DIAM) u * POUND OR NUMBER IN INCHES INT INTERIOR UL UNDERWRITER'S LABORATORIES A/C A AIR CONDITIONING UNF UNFINISHED ACI AMERICAN CONCRETE INSTITUTE J UON UNLESS OTHERWISE NOTED ACP A SBESTOS CEMENT PIPE JAN JANITOR UOS UNLESS OTHER SPECIFIED ACSG ASPHALTIC CONCRETE SURFACE COURSE JB JUNCTION BOX UR URINAL ACU AIR CONDITIONING= UNIT JCT JUNCTION UTIL UTILITY ACT ACOUSTICAL CEILING TILE JSK JANITORS SINK V AD AREA DRAIN JT JOINT ADJ ADJUSTABLE K VB VINYL BASE A/E ARCHITECT /ENGINEER VCT VINYL COMPOSITION TILE AF ACCESS FLOORING KO KNOCK OUT VERT VERTICAL AFF ABOVE FINISHED FLOOR VEST VESTIBULE AGGR AGGREGATE L VF VERIFY IN FIELD AHU AIR HANDLING UNIT L LENGTH VOL VOLUME ALT ALTERNATE LAM LAMINATE VT VAPOR TIGHT VTR VENT THRU ROOF AL ALUMINUM LAV LAVATORY ANN ANNUNCIATOR LBS POUNDS w ANSI AMERICAN NATIONAL STANDARDS INSTITUTE LBS /HR POUNDS PER HOUR ANT ANTENNA LD LINEAR DIFFUSER WR WIRE AP ACCESS PANEL LP LOW POINT W WINDOW APL ACCESS PLENUM LT LIGHT W/ WITH AFROX APPROXIMATE WC WATER CLOSET ARCH ARCHITECTURAL M WCO WALL CLEANOUT A &B ASBESTOS MATL MATERIAL WD WOOD ASPH ASPHALT MAX MAXIMUM WF WALL FABRIC ASTM AMERICAN SOCIETY OF TESTING 4 MATERIALS MC MEDICINE CABINET W/O WITHOUT 8 MEGH MECHANICAL WP WATER PROOF BAT BATTERY MEMB MEMBRANE WSCT WAINSCOT BD BOARD MFR MANUFACTURER WT WEIGHT BITUM BITUMINOUS MIN MINIMUM WWF WELDED WIRE FABRIC BLDG BUILDING WWM WELDED WIRE MESH MISG MISCELANEOUS E31-KG BLOCKING: MO MASONRY OPENING BM BEAM MTD MOUNTED BOT BOTTOM MTL METAL C MUL MULLION CAB CABINET MULT MULTIPLE CB CATCH BASIN N CEM CEMENT N NORTH CER CERAMIC NEC NATIONAL ELECTRIC CODE CG D CUBIC FEET PER MINUTE NIC NOT IN CONTRACT CG CORNER GUAR CHP CRICKET HIGH POINT NO NUMBER ROM NOMINAL CI CAST IRON NFL NAME PLATE GIC CAST IRON COVER NTS NOT TO SCALE GIP CAST IRON PIPE CJ CONTROL JOINT O CLG CEILING OA OVERALL CLGD CEILING DIFFUSER OB& OBSCURE CLKG CAULKING OC ON CENTER CLO CLOSET OD OUTSIDE DIAMETER DIM) CLP CRICKET LOW POINT OFS OVERFLOW SCUPPER CLR CLOSER OFF OPPOSITE CMP CORRUGATED METAL PIPE CMU CONCRETE MASONRY UNIT P CNTR COUNTER PC PRECAST CONCRETE CO CLEAN OUT FJ PIPE JOINT COL COLUMN FL PLASTIC COMM COMMUNICATION P LAM PLASTIC LAMINATE CONC CONCRETE FLAS PLASTER CONN CONNECTION FLYWD PLYWOOD CONSTS CONSTRUCTION PNT FAINT CONT CONTINUOUS PT POINT OR PATIENT CPT CARPET TILE PTD PAPER TOWEL DISPENCER GT CERAMIC TILE FTN PARTITION CTR CENTER PTR PAPER TOWEL RECEPTACLE CTSK COUNTERSUNK Q P QRT QUARTER DBL DOUBLE QT QUARRY TILE DEG DEGREE R DEPT DEPARTMENT REAR DESIG DESIGNATION DET RA RETURN AIR DETAIL DF DRINKING FOUNTAIN RAD RADIUS DG DOOR GRILLE RB REINFORCED BEAM DIA DIAMETER RCPT RECEPTION DIAL DIAGRAM RD ROOF DRAIN DIM DIMENSION REF REFERENCE DISR DISPENSER REINF REINFORCED DN DOWN REQ REQUIRED DO DOOR OPENING RESL RESILIENT RGTR REGISTER DSP DRY STANDPIFE R ROOM DS R DOWN SPOUT O O ROUGH OPENING DWG& DRAWINGS RWL RAIN WATER LEADER DDWR DRAWER S EA EACH S STUCCO EC EPDXY COATING SC SCREED CONCRETE EHD ELECTRIC HAND DRYER SCHED SCHEDULE EL ELEVATION SEC SECOND EJ EXPANSION JOINT SD SMOKE DETECTOR ELEC ELECTRICAL SECT SECTION ELEV ELEVATOR SF SUPPLY FAN EMER EMERGENCY SG SPANDREL GLASS ENCL ENCLOSURE SGR SYNTHETIC GRADE ENGR ENGINEER SHR SHOWER EFNL ELECTRICAL PANEL 5HT SHEET EQ EQUAL SIG SIGNAL EQPT EQUIPMENT SIM SIMILAR EST ESTIMATE 5K SINK ET EXPANSION TANK SM SHEET METAL EWC SMK SMOKE ELECTRIC WATER COOLER SND SOUND EXH EXHAUST SPEC SPECIFICATION T EXISTING SPKR SPEAKERS V EXTERIOR SQ SQUARE FA FIRE ALARM SQFT SQUARE FEET FABL FIRE ALARM BELL SST STAINLESS STEEL FD FLOOR DRAIN ST STREET FG FIBERGLASS STC SOUND TRANSMISSION COEFFICIENT FCC) FLOOR CLEANOUT STD STANDARD FD FIRE DAMPER ST -D STORM DRAIN FDC FIRE DEPARTMENT CONNECTOR STL STEEL FDR FIRE DOOR STRL STRUCTURAL Fl--)N FOUNDATIONS SUSP SUSPENDED FDV FIRE DEPARTMENT VALVE SYM SYMMETRICAL FEC FIRE EXTINGUISHER CABINET SYS SYSTEM FEX FIRE EXTINGUISHER T FF FINISH FLOOR T TOILET FH FIRE HYDRANT TB TIE BEAM FIN FINISH TC TIE COLUMN FL FLOOR TEL TELEPHONE FM FACTORY MANUAL TEMP TEMPERATURE FLASH FLASHING T4G TONGUE AND GROVE FLG FLANG=E THK THICK FLOUR FLUORESCENT TOC TOP OF CURB FOC FACE OF CONCRETE TOFF TOP OF PARAPET FOF FACE OF FINISH TOS TOP OF SLAB FOM FACE OF MASONRY TP TOP OF PAVEMENT FOS FACE OF STUD TRD TREAD FPRF FIREPROOF TS TUBULAR STEEL FPM FEET PER MINUTE TSTAT THERMOSTAT FRD FRENCH DRAIN TV TELEVISION FS FULL SIZE TW TOP OF WALL FT FOOT O R TY TYPICAL F FEET P FTG FOOTING FT-LB FOOT POUNDS FURR FURRING FUT FUTURE CS iiiiiiiiiiiiiiiiiiiiiillillilillillilI GA GAUGE GAL GALLON GALV GALVANIZED GB GRADE BEAM GEN GENERATOR GL GLASS GNP GROUND GLB GLASS BLOCK GR GRILLE GRD GRADE GWB GYPSUM WALL BOARD GYP GYPSUM N rrrmTm �rri HB HOSE BIB HG HANDICAPPED 0�°' HDWD HARDWOOD HDWE HARDWARE � � � � A HGT HEIGHT � • ,®� � NM HOLLOW METAL HORIZ HORIZONTAL HP HIGH POINT. HR HOUR 3 0' -1-- -� HTR HEATER �1 O. , -. P.� � �% C HYD HYDRANT ��� HEATING, VENTILATION, AND AIR CONDITIONING �� ` ^��. „•,- • °' *� -�