10-965R-008PLUMBING SPECIFICATIONS PART 1- GENERAL 1.01 GENERAL DOCUMENTS A. THE REQUIREMENTS OF THE GENERAL CONDITIONS & SPECIFICATION BOOK SHALL APPLY TO ALL PLUMBING WORK. INSTALLATION SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 2007 - PLUMBING WITH LOCAL & CURRENT AMENDMENTS. B. THE PLUMBING WORK SHALL FURNISHING ALL LABOR, EQUIPMENT, MATERIALS AND SERVICE NECESSARY FOR AND REASONABLY INCIDENTAL TO THE PROPER COMPLETION OF ALL PLUMBING WORK SHOWN ON THE DRAWINGS AND AS SPECIFIED. ALL MATERIAL SHALL BE NEW. C. ALL MATERIALS AND EQUIPMENT SHALL BE THE STANDARD CATALOGED PRODUCT OF A REPUTABLE MANUFACTURER REGULARLY MANUFACTURING THE PARTICULAR ITEM, FREE FROM DEFECTS AND IN NEW CONDITION. 1.02 SUBMITTALS A. MATERIALS OR PRODUCTS SPECIFIED HEREIN AND /OR INDICATED ON DRAWINGS BY TRADE NAME, MANUFACTURER'S NAME OR CATALOG NUMBERS SHALL BE INTERPRETED AS ESTABLISHING A STANDARD OF QUALITY AND DESIGN. EQUAL TO THAT SPECIFIED. SUBSTITUTIONS SHALL NOT BE ALLOWED UNLESS THEY ARE SUBMITTED FOR REVIEW AN AND APPROVED BY BID DATE. 1.03 WORK BY OTHERS A. THE FOLLOWING SYSTEMS AND /OR EQUIPMENT ARE NOT A PART OF THIS SECTION, BUT SHALL BE PROPERLY CONNECTED WITH ALL PLUMBING SERVICES: - ELECTRICAL POWER WIRING BY ELECTRICAL SUB - CONTRACTOR. 1.04 SHOP DRAWINGS A. FURNISH SIX (6) COPIES OF SHOP DRAWING OF EQUIPMENT AND FIXTURES FOR APPROVAL PRIOR TO PURCHASING. 1.05 RECORD DRAWINGS A. AFTER COMPLETION OF ALL WORK, THE PLUMBING CONTRACTOR SHALL PROVIDE THE OWNER, ENGINEER, AND ARCHITECT WITH AS BUILT RECORD DRAWINGS AS OUTLINED IN SPECIFICATIONS. PART 2 - INSTALLATION 2.01 MATERIAL A. SOIL, WASTE, & VENT PIPING: ABOVE FLOOR SLAB SHALL BE PVC -DWV SCHEDULE 40 PIPE AND FITTINGS WITH SOLVENT WELD JOINTS. B. DOMESTIC WATER PIPING: COLD, AND HOT WATER PIPING ABOVE FLOOR SLAB SHALL BE SCHEDULE 40 CPVC PLASTIC PIPING WITH SOLVENT WELD JOINTS. C. THE CONTRACTOR SHALL VERIFY EXISTING 4th FLOOR CEILING SPACE TO ASSURE TAT THERE IN NOT RETURN AIR PLENUM. USE NONCOMBUSTIBLE MATERIALS IN RETURN AIR PLENUM, D. PIPE INSULATIONS: HOT WATER SUPPLY PIPING SHALL BE INSULATED WITH 1" THICK FIBERGLASS OR EQUAL, IN COMPLIANCE WITH APPLICABLE ENERGY CODES, STORM WATER PIPING INCLUDING ROOF DRAIN SUMPS, ALL HORIZONTAL RAINWATER LEADERS & ANY PIPING ABOVE SLAB RECEIVING COLD WATER DISCHARGE FORM A/C UNITS, ICE MACHINES ETC. SHALL BE INSULATED WITH 1' THICK FIBERGLASS (OR EQUAL) INSULATION WITH VAPOR JACKET. 2.02 VALVES A. DOMESTIC WATER: MILWAUKEE OR NIBCO, CRANE OR WALWORTH. BRONZE BODY CHROME PLATED BALL, RPTFE SEATS, 150 LB. BALL VALVES UP TO 2'. 2 X"& ABOVE TO BE BRONZE BODY GATE VALVES. 2.03 SPECIALTIES C. PIPE PROTECTIVE COATING: FOR STEEL OR COPPER PIPE, PERMACEL OR SCOTHWRAP VINYL TAPE APPLIED OVER PIPE TO A TOTAL MINIMUM THICKNESS OF 20 MLS. APPLY TO ALL WATER PIPE IN CONTACT WITH MASONRY OR CONCRETE. D. PIPE HANGERS: HANGERS FOR BARE COPPER PIPE THROUGH 4 INCH (4 ") DIAMETER OR SMALLER SHALL BE ADJUSTABLE RING TYPE, PLASTIC COATED EQUAL TO MICHIGAN 102a, FOR STEEL PIPE MICHIGAN 100. E. DRAINS AND CLEANOUTS: SEE SCHEDULE ON DRAWINGS. F. DIELECTRIC UNIONS: EBCO OR CAPITOL AT ALL POINTS OF CONNECTION BETWEEN DISSIMILAR PIPE METALS. G. FLASHING AND VENT STACKS: ALL VENTS EXTENDING THROUGH THE ROOF SHALL BE PROVIDED WITH FOUR POUND SHEET LEAD FLASHING EXTENDING UPWARD AROUND THE PIPE AND TURNED DOWN INSIDE THE PIPE OR AS OTHERWISE SHOWN ON THE DRAWINGS. THE ROOF FLASHING SHALL BE INSTALLED BY LICENSED ROOFING CONTRACTOR. H. WATER HAMMER ARRESTORS: AT EACH FIXTURE, A GROUP PROVIDES'SA° AS SPECIFIED IN SPECIALTIES SCHEDULE AND ELSEWHERE AS REQUIRED, AND IN ALL CONNECTIONS TO EQUIPMENT WITH SOLENOID VALVE INSTALLED ON WATER SUPPLY LINE. WATER HAMMER ARRESTORS SHALL BE SIZED AND INSTALLED AS PER MANUFACTURER'S RECOMMENDATIONS FOR PREVENTION OF WATER HAMMER IN ACCORDANCE WITH PDI -WH2O1 STANDARDS, 1. ESCUTCHEONS AND SLEEVES, WHERE PIPES PIERCE EXPOSED PARTITIONS, FLOORS, WALL, OR CEILINGS, PROVIDE CHROME PLATED ESCUTCHEONS TO THE COVER THE RAW EDGE. J. SLEEVES SHALL BE PROVIDED AT ALL PIPE PENETRATIONS OF MASONRY AND CONCRETE WALLS AND FLOORS. PART 3 - EXECUTION 3.01 INSTALLATION A. INSTALL PIPE ABOVE GROUND PLUMB AND SQUARE WITH BUILDING LINES, ADEQUATELY SUPPORTED WITHOUT SAGS OR HIGH POINTS. CONCEAL PIPING IN OCCUPIED AREAS AND MAINTAIN HEAD ROOM AND ACCESS SPACE IN UNFINISHED AREAS. SLEEVE PIPING THROUGH ALL WALLS, SLABS, OR PARTITIONS WITH ESCUTCHEONS AT ALL FINISHED SURFACE. PROVIDE UNIONS AT ALL FINAL CONNECTIONS AND STOPS ON ALL SUPPLIES. ALL PIPE OPENINGS SHALL BE PLUGGED DURING INSTALLATION. B. SANITARY DRAINAGE PIPING 4'& LARGER SHALL BE INSTALLED WITH A MINIMUM 1/8" PER FOOT SLOPE UNLESS NOTED OTHERWISE. ALL DRAINAGE PIPING WAND SMALLER SHALL BE INSTALLED WITH A MINIMUM OF 1/4" PITCH PER FOOT. C. ALL FIXTURES AND TRIM FOR HANDICAPPED SHALL BE INSTALLED IN COMPLIANCE WITH ADA CODE. D. INSTALL ALL PIPING TO ALLOW FOR EXPANSION. E. SEE RISER DIAGRAMS FOR ALL DRAINAGE & VENT PIPE SIZING FOR THE PLUMBING SYSTEMS. REFER TO PLUMBING FLOOR PLAN (WATER SYSTEM) & SCHEDULES FOR ALL WATER PIPING SYSTEM SIZING. F. ALL EXPOSED TO VIEW PIPING AND FITTINGS SHALL BE POLISHED CHROME FINISH. G. ALL WORK ASSOCIATED WITH HANDICAPPED TOILETS SHALL COMPLY WITH ADA REQUIREMENTS AND FLORIDA BUILDING CODE - CHAPTER 11 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION. H. ALL PIPING SUPPORT TYPE & SPACING TO BE IN ACCORDANCE WITH FBC 2007 PLUMBING - SECTION 308. 3.02 DISINFECTING OF POTABLE WATER SYSTEM A, THE SYSTEM SHALL BE FILLED WITH A SOLUTION CONTAINING 50 PARTS PER MILLION OF AVAILABLE CHLORINE AND ALL ALLOWED TO STAND 24 HOURS BEFORE FLUSHING AND RETURNING TO SERVICE. DISINFECTION PROCEDURE AND RESULT SHALL BE SUBJECT TO THE APPROVAL OF THE LOCAL PLUMBING INSPECTOR. 3.03 TEST A. ALL PLUMBING SYSTEMS SHALL BE TESTED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE PLUMBING. ALL TESTS SHALL BE APPROVED BY THE LOCAL PLUMBING INSPECTOR AND SHALL BE OBSERVED BY A REPRESENTATIVE OF THE ARCHITECT. 3.04 SYSTEM IDENTIFICATION A. THE PLUMBING CONTRACTOR SHALL PROVIDE IDENTIFICATION TAGS FOR ALL NEW PIPING AND VALVES IN THE BUILDING AS PER OWNER ACCEPTED STANDARDS, THE PIPE MARKS SHALL INCLUDE PIPING SYSTEM IDENTIFICATION AND DIRECTIONS OF FLOW. EVERY 10 FEET AND CHANGED OF DIRECTION. 3.05 SPECIFICATIONS AND DRAWINGS A. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL COMPLETE SANITARY, STORM, AND DOMESTIC WATER PIPING SYSTEMS: INCLUDING ALL ASSOCIATED DEVICES, EQUIPMENT, CONTROLS, AND CONNECTIONS TO NEW SERVICES, SUPPORTS, AND HARDWARE REQUIRED FOR THE SATISFACTORY OPERATIONS OF THE SYSTEMS, WHETHER SPECIFICALLY SHOWN OR NOT ON THE DRAWINGS. B. THE PLANS SHOW THE LOCATION OF ALL FIXTURES AND EQUIPMENT AND ARE INTENDED TO DEPICT THE GENERAL INTENT OF THE WORK IN SCOPE, LAYOUT, AND QUALITY OF WORKMANSHIP. THEY ARE NOT INTENDED TO SHOW IN MINUTE DETAIL EVERY AND ALL ACCESSORIES INTENDED FOR THE PURPOSE OF EXECUTION OF THE WORK, BUT IT SHALL BE UNDERSTOOD THAT SUCH DETAILS WILL BE PART OF THIS WORK. C. WHERE DRAWINGS AND SPECIFICATIONS CONFLICT, IT SHALL BE THE RESPONSIBILITY OF THIS CONTRACTOR TO BRING SUCH CONFLICT TO THE ATTENTION OF THE ENGINEER FOR CLARIFICATION. D. REFER TO ARCHITECTURAL DRAWINGS AND VERIFY FIELD CONDITION FOR EXACT LOCATION OF ALL PLUMBING FIXTURES. E. CONTRACTOR SHALL KEEP A RECORD OF THE LOCATIONS OF ALL CONCEALED WORK AND UPON COMPLETION OF THE JOB, SHALL SUPPLY AS -BUILT DRAWINGS SHOWING IN COLORED PENCIL ON BLACK LINE PRINTS ANY DEVIATION FROM THE ORIGINAL DRAWINGS. THESE DRAWINGS SHALL INDICATE DIMENSION OF BURIED UTILITY LINES FROM BUILDING WALLS. F. ALL DOCUMENTS, TEST REPORTS, & AS -BUILT DRAWINGS SHALL BE ATTACHED TO THE CLOSING DOCUMENTS OF THE PROJECT. 3.06 WARRANTY A. THE PLUMBING CONTRACTOR SHALL WARRANT HIS WORK TO BE FREE FROM DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM FINAL ACCEPTANCE OF ALL WORK. 3.07 COORDINATION A. GENERAL CONTRACTOR SHALL PROVIDE SHOP DRAWING COORDINATING ALL TRADES AND EXISTING OBSTACLES PRIOR TO STARTING CONSTRUCTION. B. VERIFY LOCATIONS, SIZES, AND INVERT ELEVATIONS OF SANITARY DRAIN, AND DOMESTIC WATER PIPING CONNECTIONS WITH FIELD CONDITIONS AND CIVIL ENGINEERING DRAWINGS PRIOR TO PROCEEDING WITH THE INSTALLATION OF ANY NEW WORK. SHALL ANY DISCREPANCIES BE DISCOVERED CONTRACTORS SHOULD OBTAIN DIRECTION FROM THE ENGINEER BEFORE PROCEEDING, C. COORDINATE WITH ARCHITECTURAL DRAWINGS FOR WALL AND PARTITION CONSTRUCTION AND THICKNESS WHERE PLUMBING PIPING, FIXTURES CARRIERS OR EQUIPMENT IS INDICATED. BEFORE STARTING CONSTRUCTION. IDENTIFY ANY CONFLICT PRIOR TO STARTING CONSTRUCTION. D. COORDINATE EXACT LOCATION, ELEVATIONS, AND SIZES OF ALL SLEEVES IN NEW STRUCTURE WITH STRUCTURAL AND ARCHITECTURAL DRAWINGS AND FIELD CONDITIONS. E. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH LATEST ADAPTED FLORIDA BUILDING, PLUMBING, FUEL GAS, & MECHANICAL CODES & MANUFACTURERS INSTALLATION INSTRUCTIONS, 3.08 PERMITS A. PLUMBING CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS AT HIS EXPENSE. B. THE PLUMBING CONTRACTOR SHALL VERIFY THESE DRAWINGS WITH EXISTING FIELD CONDITIONS AND SHALL COORDINATE WITH CIVIL ENGINEER LOCATIONS AND ELEVATIONS OF PLUMBING SERVICE LINES BEFORE PROCEEDING WITH CONSTRUCTION. THE WATER AND SEWER SERVICE LINES SHOWN ON THE DRAWINGS ARE FOR REFERENCE AND BUILDING PERMIT ONLY. REFER TO CIVIL ENGINEERS DRAWING AND VERIFY FIELD CONDITIONS FOR DRAINAGE AND WATER SERVICE LINES LAYOUT AND DETAILS. C. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT /ENGINEER IMMEDIATELY IF ANY OF THE WORK INDICATED IN THE CONTRACT DOCUMENTS CANNOT BE PERFORMED DUE TO EXISTING FIELD CONDITIONS. D. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL COMPLETE SANITARY AND DOMESTIC WATER PIPING SYSTEMS: INCLUDING ALL ASSOCIATED DEVICES, EQUIPMENT, CONTROLS, AND CONNECTIONS TO EXISTING SERVICES, SUPPORTS, AND HARDWARE REQUIRED FOR THE SATISFACTORY OPERATION OF THE SYSTEMS. E. PLUMBING CONTRACTOR SHALL PROVIDE ROUTING AND OFFSETS NECESSARY TO AVOID CONFLICT WITH STRUCTURE, FINISHES, AND WORK OF OTHER TRADES. F. WALL AND PARTITION CONSTRUCTION AND THICKNESS FOR PLUMBING PIPING OR EQUIPMENT IS INDICATED SHALL BE AS PER EQUIPMENT MANUFACTURERS SHOP DRAWINGS AND ANY CONFLICT SHALL BE IDENTIFIED PRIOR TO STARING CONSTRUCTION. G. COORDINATE EXACT LOCATION, SIZE, AND ELEVATIONS OF PIPE SLEEVES IN EXISTING STRUCTURE WITH STRUCTURAL ENGINEER. H. THE LOCATION AND ELEVATION OF PLUMBING PIPING AT CEILING, WALLS, AND BELOW SLAB FOR OWNER FURNISHED, CONTRACTOR INSTALLED EQUIPMENT IS SHOWN AS PER EQUIPMENT DATA SHEETS. THE CONTRACTOR SHALL PROVIDE PLUMBING ROUGH -INS AS PER OWNERS PROVIDED FINAL. 1. PROVIDE UL LISTED FIRE STOPPING PIPE PENETRATION ASSEMBLIES AT ALL PIPING THROUGH FIRE RATED WALLS AND ASSEMBLIES. I PLUMBING FIXTURE SCHEDULE MARK FIXTURE SOIL/ WASTE VENT COLD HOT MANUFACTURER( DESCRIPTION ZN -4158 9' DIA. TYPE "B' STRAINER, MEMBR. CLAMP. ARM WALL CLEANOUT WATER WATER MODEL# SA EWC-1H ELECTRIC WATER COOLER FOR H/C 2° T 1/2" - ELKAY # EZSTL8C - ELKAY, BARRIER -FREE COOLER, WALL MOUNTED TWO LEVEL WHEELCHAIR ACCESS, ONE PIECE STAINLESS STEEL BASIN EACH COOLER WITH INTEGRAL e 8 rn w E� DRAIN GRID, & BUBBLER, HEAVY -DUTY STEEL FRAME, LED -FREE WATERWAY, oil c� 8.0 GPH ( @50'F W /90'F AMBIENT), 1/5 HP, 115V/1 Ph/60Hz EACH. (3.7 AMPS) c a � Q c m m n (SEE NOTE # 1 & 5). w` m C6 SS ° w WATTS # 5-YR -IN LINE WATER FILTER. aQa ZURN # Z- 1225 -BL -WATER COOLER SUPPORT SYSTEM WITH TOP AND BOTTOM PLATES. COMPLETE WITH DURA- COATED RECTANGLE STEEL UPRIGHTS WITH WELDED FEET, ADJUSTABLE SUPPORT, PLATES, AND MOUNTING FASTENERS. WAH WATER CLOSET FLOOR 4° 2' 1/2' AMERICAN - MADERA 16 -1/2" RIM HEIGHT VITREOUS CHINA, WATER SAVER 1.6 GPF, EVER CLEAN, MOUNTED FLUSH STANDARD ELONGATED, SIPHON ACTION JETTED BOWL, WITH BOLT CAPS, TOP SPUD, ANTIMICROBIAL, VALVE FOR H/C OPEN # 3461.160 (12' ROUGH -IN). FRONT SEAT SLOAN ROYAL - FLUSHOMETER, LOW CONSUMPTION VALVE, #111 OLSONITE # 10SSCTFR -WHITE OPEN FRONT SEAT LESS COVER, ANTIMICROBIAL. W_2H WATER CLOSET FLOOR 4° 2° 1/2' AMERICAN - MADERA 16 -1Y1" RIM HEIGHT VITREOUS CHINA, WATER SAVER 1.6 GPF, EVER CLEAN, MOUNTED FLUSH VALVE STANDARD ELONGATED, SIPHON ACTION JETTED BOWL, WITH BOLT CAPS, BACK SPUD, (12° ROUGH -IN). FOR H/C OPEN FRONT # 3463.160 SEAT LESS COVER SLOAN ROYAL - FLUSHOMETER, LOW CONSUMPTION VALVE WITH SLOAN EASY ACCESS WALL BOX. # 152 -1.6 WB OLSONITE # 10SSCTFR -WHITE OPEN FRONT SEAT LESS COVER, ANTIMICROBIAL. S_1 SINGLE BOWL SINK 2' 2' 1/2' 10 ELKAY -15"X 15" SINK, COUNTERTOP, SINGLE BOWL BOWL, SELF RIM, # 302 STAINLESS # BCR15 STEEL W/DROP LEDGE. THREE HOLE PUNCH. CHICAGO -TOP MOUNT FAUCET WITH 8- CENTERS, SWIVEL GOOSENECK # 786- GN8E3CP SPOUT, AND COLOR INDEXED WRIST BLADES HANDLES, POLISHED CHROME FINISH # LK18 -DRAIN STAMPED BRASS DRAIN, WITH STOP VALVES AND SUPPLIES. SEE NOTES #1, & 2 ) SAH SINGLE BOWL SINK FOR H/C 2' 2° 1/2' 10 ELKAY -19 °L X 18"W X 4' DEEP SINK, 16 "L X 11 -1/2 -W BOWL, COUNTERTOP, SINGLE BOWL, SELF RIM, # 302 # LRAD1918 STAINLESS STEEL W/DROP LEDGE. THREE HOLE PUNCH CHICAGO -TOP MOUNT FAUCET WITH 8" CENTERS, SWIVEL GOOSENECK # 786- GN8E3CP SPOUT, AND COLOR INDEXED WRIST BLADES HANDLES, POLISHED CHROME FINISH # LK18 -DRAIN STAMPED BRASS DRAIN, WITH STOP VALVES AND SUPPLIES. (SEE NOTES #1, 2, & 3) L -11 LAVATORY WALL MOUNTED 2- 2" 1/2' 1/2" KOHLER - LAVATORY WALL HUNG, 14'X 12 ", VITREOUS CHINA, INTEGRAL SLOW DRAINING OUTLET, # K -2475 INTEGRAL BUBBLER AND SOAP DISH, BUILT -IN SUPPLY, OUTLET AND INLET SPUDS, POLISHED CHROME. KOHLER - SHELF -BACK LAVATORY FAUCET, BRASS CONSTRUCTION, 6-1/2' CENTERS, CONCEALED # K -7482 SELF - CLOSING VALVES, 3/8" NPT CONNECTIONS, VANDAL- RESISTANT, INDEX PUSH BUTTONS FOR HOT & COLD WATER, POLISHED CHROME, FOR INSTALLATION IN A 8- WIDE STUD WALL. (SEE NOTES #1, & 2) L -1H LAVATORY WALL Y /2' 112° AMERICAN 20-1/2 x 18 -114, LUCERNE WALL-HUNG SINK, VITREOUS CHINA, FRONT OVERFLOW, MOUNTED FOR H/C STANDARD D- SHAPED BOWL, SUPPORTED FROM FLOOR (WITHSTANDING 250# OF LOAD # 0355.012 APPLIED ON THE FRONT OF THE FIXTURE) AMERICAN - RELIANT 3 SINGLE CONTROL CENTERSET, INDEXED METAL LEVER HANDLE, STANDARD LESS DRAIN, LESS POP-UP HOLE, NON - AERATED VANDAL - RESISTANT 0.5 # 7385.004 G.P.M. FLOW OUTLET, FOR 4° FAUCET HOLES, ADJUSTABLE HOT LIMIT SAFETY STOP. DRAIN & SUPPLIES: (SEE NOTES #1, 2, 3, & 4) ZURN # Z -1231 - LAVATORY SUPPORT SYSTEM WITH CONCEALED ARMS. COMPLETE WITH DURA- COATED RECTANGLE STEEL UPRIGHTS WITH WELDED FEET, CAST IRON ADJUSTABLE HEADERS,CONCEALED ARMS, STEEL SLEEVES, ALIGNMENT TRUSS AND MOUNTING FASTENERS. SEE DETAIL #3 ON PLUMBING SHEET #P5. BPW -1 BED PAN WASHER - 1/2" - SEE DETAIL -BED PAN WASHER. SEE DETAIL #1 ON SHEET #P -5 FOR MANUFACTURER & MODEL #'S FOR ASSEMBLY, SHAH SHOWER FOR H/C 2° FD 2" 1/2" 1/2" LEONARD # 76-3A - CERAMIC TILE SHOWER. SEAT & GRAB BARS IN STALL BY GENERAL CONTRACTOR TRIM: CONCEALED PRESSURE BALANCING THERMOSTATIC MIXING VALVE, BUILT -IN TEMPERATURE LIMIT STOP, HEAVY CAST BRASS BODY, STAINLESS STEEL FACEPLATE, LEVER HANDLE, CORROSION MATERIAL CONSTRUCTION, 1/2- N.P.T INLET CONNECTIONS, 1/2° N.P.T OUTLET, WATER SEAL GASKET, MAXIMUM TEMPERATURE SET POINT AT 105° F, STRAIGHT CHECK STOPS, CHROME PLATED BRASS BODY SELF CLEANING SPRAY DISC, UNIVERSAL BALL JOINT, DIRECTIONAL ADJUSTMENT, ALLEN HEAD SET SCREWS, 2.0 G.P.M. FLOW, BRASS MOUNTING BODY WITH BACK PLATE MOUNTING SUPPORT, DIVERTER VALVE, AND HAND HELD SHOWER. WITH 24' SLIDE RAIL, DOUBLE CHECK VALVE BACKFLOW PREVENTOR SH -2H SHOWER FOR H/C 2° 1/2" 1/2" LEONARD - CERAMIC TILE SHOWER. SEAT & GRAB BARS IN STALL BY GENERAL CONTRACTOR TRIM: F® # 76- 3A- H06- AP -QD-VP CONCEALED PRESSURE BALANCING THERMOSTATIC MIXING VALVE, BUILT -IN TEMPERATURE LIMIT STOP, HEAVY CAST BRASS BODY, STAINLESS STEEL FACEPLATE, LEVER HANDLE, CORROSION MATERIAL CONSTRUCTION, 1/2- N.P.T INLET CONNECTIONS, 1/2' N.P.T OUTLET, WATER SEAL GASKET, MAXIMUM TEMPERATURE SET POINT AT 105' F, STRAIGHT CHECK STOPS, CHROME PLATED BRASS BODY SELF CLEANING SPRAY DISC, ADJUSTMENT, ALLEN HEAD SET SCREWS, 20 G.P.M. FLOW, BRASS MOUNTING BODY WITH BACK PLATE MOUNTING SUPPORT, DIVERTER VALVE, AND HAND HELD SHOWER. WITH 24" SLIDE RAIL. PROVIDE VANDAL RESISTANT SCREWS & INSTITUTIONAL SECURITY TYPE SHOWER HEAD WITH QUICK DISCONNECT ON FLEXIBLE HOSE ON HAND HELD SHOWER HEAD, DOUBLE CHECK VALVE BACKFLOW PREVENTOR. NOTES: t LAVATORY & WATER COOLERS SUPPLY SHALL BE BRASS W/ BRASS ANGLE STOPS FOR 1/2' WATER SUPPLY LINES, W/ LOOSE KEY (W /CAP), AND WALL FLANGE. ALL COMPONENTS SHALL BE POLISHED CHROME FINISH. MANUFACTURER: E.B.C., INC. OR APPROVED EQUAL. (REPLACE ALL EXISTING STOPS & SUPPLIES WITH NEW) 2. CAST BODY "P' TRAP 1-1/2"x 1 1/2" WITH HEAVY CAST J -BEND & FLAT CLEANOUT PLUG, SLIP NUTS AND WALL FLANGE. ALL COMPONENTS SHALL BE POLISHED CHROME FINISH. MANUFACTURER: E.B.C., INC. OR APPROVED EQUAL. 3. STRAINERS SHALL BE FURNISHED W/FIXTURES. FOR H/C LAVATORY PROVIDE OFFSET TAILPIECE. 4. PROVIDE TRUEBRO MODEL 103 (WHITE), ANTIMICROBAL HANDI LAV- GUARDS INSTALLATION KIT FOR ALL WHEELCHAIR LAVATORY & SINKS FOR WATER SUPPLIES & WASTE LINE. 5. PROVIDE WATER SUPPLY &"P* TRAP & OPTIONAL WATER FILTERS FOR ELECTRIC WATER COOLERS AS PER MANUFACTURERS RECOMMENDATIONS. 6, CONTRACTOR TO VERIFY IF EXISTING CHAIR CARRIERS ARE INSTALLED TO HANDLE 250 LBS. LOAD AT FRONT OF FIXTURE. CONTRACTOR TO VERIFY IN FIELD LOCATION OF ALL EXISTING PIPING IN THE CHASES. AVOID INTERFERENCE WITH CARRIER ANCHOR BOLTS. SEE DETAIL #3 ON PLUMBING SHEET #P5. SPECIALTIES SCHEDULE MARK DESCRIPTION/LOCATION MANUR CAT. NUMBER GENERAL NOTES FD FLOOR DRAIN ZURN ZN -4158 9' DIA. TYPE "B' STRAINER, MEMBR. CLAMP. WCO WALL CLEANOUT ZURN Z -1446 ROUND S.S. ACCESS COVER, SA W. HAMMER ARRESTOR ZURN Z -1700 SHOKTROL SIZE FOR 314' & 1' PIPE. • N r o •� v o J 3t owe 'tQ AV N Aill Wi2 x _3 ►� co - • Uoco fiffill ► m► Do 400 No, Na. rN. ® P pppeseeapp S � e p po ! • e ! e f( {f s s f p STATE OF e mow. . pk/ °Pty ".Ofd% p 'ON A� LICENSE ': EE71611 F'RNTED NAME: DAVID S. IBESS • +i • • • a • 5 Z O ■ Z 00 5 ° �+g 13 0 g Ls€ a^ cZ °a <N °oa�m m TM � c e 8 rn w E� ; oil c� $ a c a � Q c m m n w` m C6 SS ° w aQa • +i • • • a • 5 Z O ■ Z 00 5 ° �+g 13 0 W N co) a^ 00 Q N <N °oa�m 1 r • 4` 4 �s "taw �+g 13 0 R me� TM