Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
10-685-050
EXISTING PANEL 'LS' 120/208V 125A, 30 42 POS. MLO LEGEND EXISTING EXISTING PANEL 'A3' PANEL 'B3' 120/208V 120/208V 225A, 30 225A, 30 42 POS. 42 POS. MLO MLO 2ooA 2ooA EXISTING EXISTING PANEL 'A2' PANEL '62' 120/208V 120/208V 400A, 30 MLO 400A, 30 MLO 42 POS. 42 POS. EXISTING PANEL 'LS' 120/208V 125A, 30 42 POS. MLO 65 KIC 1 #350kcrnil in 1- 1 /4 "C. -3X4#500 kcmil in 12 "X24" C. TO FPL EXISTING PANEL 'EC3' 120/208V 225A, 30 42 POS. MLO THIRD FLOOR EXISTING PANEL 'EC2' 120/208V 225A, 30 42 POS. MLO SECOND FLOOR EXISTING EXISTING EXISTING DP -4 120/208V 3d,4W 400 AMP EXISTING EXISTING ATS -3 120/208V 3d,3P 600 AMP EXISTING CRITICAL EXISTING LIFE EMERGENCY MAIN SW #3 120/208V 30,4W 600 AMP F -500 AMP 65 KIC IN 2" PVC COND. EACH TO 3/4" CWP 1 #60Okcmil in 1- 1/2 "C. 6' EXISTING 10' -0" DEEP GROUNDING ROD - 3/4" DIAMETER EXISTING PARTIAL ELECTRICAL RISER N.T.S. OF 4 #500 IN 3" PVC COND. EACH GROUND FLOOR SCOPE OF WORK NOTE: 1 THE SCOPE OF WORK IS A RELOCATION OF NURSE STATION FACILITIES 2- ALL FEEDERS, MAIN BREAKERS AND PANELS ARE EXITING TO REMAIN, NEW 20 AMPS BREAKERS ADD TO EXISTING PANELS SHALL BE COMPATIBLE WITH EXITING PANEL BREAKERS TO DO NOT AFFECT EXISTING FAULT CURRENT AND EXISTING COORDINATION STUDY. LEGEND SERVICE FEEDER: EXISTING NUMBER OF CONDUCTORS PER PHASE: EXISTING WALL MOUNTED LIGHT (SCONCE) 1� DUPLEX RECEPTACLE m 12" AFF, U.O.N. 21,900 2'X2' FLUORESCENT LIGHT FIXTURE r 1,73 X L X 1 1,73 X 35 X 48,500 = 0.32 ® PARABOLIC, 120V EXISTING SINGLE RECEPTACLE O 12 ", U.O.N. ELECTRICAL ROOM #1 1 + f 1 + 0.32 f ISCA = AVAILABLE FROM UTILITY X M = 48,500 X DP -3 2'X2' FLUORESCENT LIGHT FIXTURE U SERVICE FEEDER: #500 PARABOLIC, 120V 120/208V GFI DUPLEX RECEPTACLE 150' LIFE SAFETY CIRCUIT C� 1,73 X L X 1 = 1,73 X 150 X 36,715 - 2.09 30,4W 2'X2' FLUORESCENT LIGHT FIXTURE Miami Florida 33133 USA GFI DUPLEX RECEPTACLE OVER COUNTER 0 PARABOLIC, 120V 200 AMP ISCA = AVAILABLE FROM UTILITY X M = 36,715 X EXISTING EMERGENCY CIRCUIT DUPLEX RECEPTACLE FLOOR MOUNTED ® 2'X4' FLUORESCENT LIGHT FIXTURE m�6m�mV6�4 EXISTING PQmm�lm6 PARABOLIC, 120V E::h SAFETY DISCONNECT SWITCH P.E. No 57468 David Guirola Electric2l Engineer p p ID p p ZZ plroa�eQOmm ©a 13850 •r2I Way Suits k203MiMi,FL33145 9mdomRIMOMN TMM1 PH:(305)a54 -S224 FAX(305)857 -6601 CA 0000 324 EXISTING ® 2'X4' FLUORESCENT LIGHT FIXTURE PARABOLIC, 120V EXISTING 1/2 "C STUBBED ABOVE CEILING. 1 /4 sc�Te:1 -0 061 -10026 -000 PANEL DR -1 Architects project Number PHONE /DATA OUTLET. PROVIDE MUD RING Drawing Issue 2'X4' FLUORESCENT LIGHT FIXTURE 120/208V REVISIONS PARABOLIC, 120V EXISTING LIGHTING SWITCH Q 48" AFF. DATE 30,4W 3$ ATS -2 EXIT LIGHT WITH BATTERY CONNECTED 1200 AMP AHEAD OF ANY SWITCH, 120V 120/208V LIGHTING SWITCH WITH DIMMER • 48" AFF. M$ 3•,3P ELECTRIC PANEL SWITCH MOTOR RATE (60AMP). 200 AMP EXISTING J -BOX EXISTING ARCHITECTURAL DOWN LIGHTING EXISTING LIFE EMERGENCY SAFETY LEO A DALY COTANY Copyright 2007 EXISTING �'• i i 5 MAIN SWITCH MAIN SW #1 120/208V 120/208V 30,4W 30,4W Seel 100 AMP ELECTRICAL RISER 1200 AMP LEGEND F -100 AMP F -1200 AMP Shoat Number 65 KIC 65 KIC 1 #350kcrnil in 1- 1 /4 "C. -3X4#500 kcmil in 12 "X24" C. TO FPL EXISTING PANEL 'EC3' 120/208V 225A, 30 42 POS. MLO THIRD FLOOR EXISTING PANEL 'EC2' 120/208V 225A, 30 42 POS. MLO SECOND FLOOR EXISTING EXISTING EXISTING DP -4 120/208V 3d,4W 400 AMP EXISTING EXISTING ATS -3 120/208V 3d,3P 600 AMP EXISTING CRITICAL EXISTING LIFE EMERGENCY MAIN SW #3 120/208V 30,4W 600 AMP F -500 AMP 65 KIC IN 2" PVC COND. EACH TO 3/4" CWP 1 #60Okcmil in 1- 1/2 "C. 6' EXISTING 10' -0" DEEP GROUNDING ROD - 3/4" DIAMETER EXISTING PARTIAL ELECTRICAL RISER N.T.S. OF 4 #500 IN 3" PVC COND. EACH GROUND FLOOR SCOPE OF WORK NOTE: 1 THE SCOPE OF WORK IS A RELOCATION OF NURSE STATION FACILITIES 2- ALL FEEDERS, MAIN BREAKERS AND PANELS ARE EXITING TO REMAIN, NEW 20 AMPS BREAKERS ADD TO EXISTING PANELS SHALL BE COMPATIBLE WITH EXITING PANEL BREAKERS TO DO NOT AFFECT EXISTING FAULT CURRENT AND EXISTING COORDINATION STUDY. LIGHTING NOTES: 1- LIGHTING FIXTURES SELECTED BY ARCHITEC /OWNER AND MATCH WITH EXISTING PANEL 'EC2' FAULT CURRENT LEGEND SERVICE FEEDER: y� M- NUMBER OF CONDUCTORS PER PHASE: b WALL MOUNTED LIGHT (SCONCE) 1� DUPLEX RECEPTACLE m 12" AFF, U.O.N. 21,900 2'X2' FLUORESCENT LIGHT FIXTURE r 1,73 X L X 1 1,73 X 35 X 48,500 = 0.32 ® PARABOLIC, 120V • SINGLE RECEPTACLE O 12 ", U.O.N. • • • 1 + f 1 + 0.32 f ISCA = AVAILABLE FROM UTILITY X M = 48,500 X 0.757 = 36,715 AMPS 2'X2' FLUORESCENT LIGHT FIXTURE U SERVICE FEEDER: #500 PARABOLIC, 120V E"x GFI DUPLEX RECEPTACLE 150' LIFE SAFETY CIRCUIT C� 1,73 X L X 1 = 1,73 X 150 X 36,715 - 2.09 3390 Mary Street, Suite 216 2'X2' FLUORESCENT LIGHT FIXTURE Miami Florida 33133 USA GFI DUPLEX RECEPTACLE OVER COUNTER 0 PARABOLIC, 120V X 0.153 = 3,020 AMPS ISCA = AVAILABLE FROM UTILITY X M = 36,715 X 0.323 = 11,859 AMPS EMERGENCY CIRCUIT DUPLEX RECEPTACLE FLOOR MOUNTED ® 2'X4' FLUORESCENT LIGHT FIXTURE m�6m�mV6�4 PQmm�lm6 PARABOLIC, 120V E::h SAFETY DISCONNECT SWITCH P.E. No 57468 David Guirola Electric2l Engineer p p ID p p ZZ plroa�eQOmm ©a 13850 •r2I Way Suits k203MiMi,FL33145 9mdomRIMOMN TMM1 PH:(305)a54 -S224 FAX(305)857 -6601 CA 0000 324 PHONE OUTLET. PROVIDE MUD RING AND ® 2'X4' FLUORESCENT LIGHT FIXTURE PARABOLIC, 120V 1/2 "C STUBBED ABOVE CEILING. 1 /4 sc�Te:1 -0 061 -10026 -000 LIFE SAFETY CIRCUIT Architects project Number PHONE /DATA OUTLET. PROVIDE MUD RING Drawing Issue 2'X4' FLUORESCENT LIGHT FIXTURE AND 1/2"C STUBBED ABOVE CEILING. REVISIONS PARABOLIC, 120V $ LIGHTING SWITCH Q 48" AFF. DATE EMERGENCY CIRCUIT 3$ EXIT LIGHT WITH BATTERY CONNECTED 3 -WAY LIGHTING SWITCH 0 48" AFF. AHEAD OF ANY SWITCH, 120V D$ LIGHTING SWITCH WITH DIMMER • 48" AFF. M$ � ELECTRIC PANEL SWITCH MOTOR RATE (60AMP). JO J -BOX O ARCHITECTURAL DOWN LIGHTING LIGHTING NOTES: 1- LIGHTING FIXTURES SELECTED BY ARCHITEC /OWNER AND MATCH WITH EXISTING PANEL 'EC2' FAULT CURRENT CALCULATION: SERVICE FEEDER: #500 NUMBER OF CONDUCTORS PER PHASE: 2 CONDUCTOR LENGTH "L ": 35' CONDUCTOR "C" VALUE: 21,900 .a r 1,73 X L X 1 1,73 X 35 X 48,500 = 0.32 • • C X EL -L 2(21,900) X 208 • M - 1 1 0.757 • • • 1 + f 1 + 0.32 f ISCA = AVAILABLE FROM UTILITY X M = 48,500 X 0.757 = 36,715 AMPS ISCA = 36,715 AMP AT MAIN # 3 DISCONNECT U SERVICE FEEDER: #500 NUMBER OF CONDUCTORS PER PHASE: 1 CONDUCTOR LENGTH "L ": 150' CONDUCTOR "C" VALUE: 21,900 1,73 X L X 1 = 1,73 X 150 X 36,715 - 2.09 3390 Mary Street, Suite 216 C X EL -L 21,900 X 208 Miami Florida 33133 USA M - 1 _ 1 = 0.323 X 0.21 = 8,413 AMPS 1 + f 1 + 2.09 X 0.153 = 3,020 AMPS ISCA = AVAILABLE FROM UTILITY X M = 36,715 X 0.323 = 11,859 AMPS ISCA = 11,859 AMPS AT PANEL 'EC2' PANEL '133' FAULT CURRENT CALCULATION: SERVICE FEEDER: #500 NUMBER OF CONDUCTORS PER PHASE: 3 CONDUCTOR LENGTH 1 ": 35' CONDUCTOR "C" VALUE: 21,900 1,73 X L X 1 = 1,73 X 35 X 48,500 = 0.21 C X EL -L 3(21,900) X 208 __ 1 __ 1 M 0.826 1 + f 1 + 0.21 ISCA = AVAILABLE FROM UTILITY X M = 48,500 X 0.826 = 40,061 AMPS ISCA = 30,701 AMP AT MAIN # 1 DISCONNECT SERVICE FEEDER: #500 NUMBER OF CONDUCTORS PER PHASE: 1 CONDUCTOR LENGTH "L ": 100' CONDUCTOR "C" VALUE: 21,900 1,73 X L X 1 1,73 X 150 X 40,061 = 2.28 C X EL -L 21,900 X 208 _ 1 M __ 1 = 0.3 1 + f 1 + 2.28 ISCA = AVAILABLE FROM UTILITY X M = 40,061 X 0.3 = 12,018 AMPS ISCA = 12,018 AMPS AT PANEL '132' SERVICE FEEDER: #3/0 NUMBER OF CONDUCTORS PER PHASE: 1 CONDUCTOR LENGTH "L ": 125' CONDUCTOR "C" VALUE- 11,100 1,73 X L X 1 = 1,73 X 120 X 12,0. 18 _ 1.08 C X EL -L 11,100 X 208 1 _ 1 M - - 0.48 1 + f 1 + 1.0$ ISCA = AVAILABLE FROM UTILITY X M = 12,018 X 0.48 = 5,769 AMPS ISCA = 5,769 AMPS AT PANEL 'B3' PANEL 'EC3' FAULT CURRENT CALCULATION: SERVICE FEEDER: #500 NUMBER OF CONDUCTORS PER PHASE: 2 CONDUCTOR LENGTH "L ": 35' CONDUCTOR "C" VALUE: 21,900 1,73 X L X 1 = 1.73 X 35 X 48,500 = 0.32 C X EL -L 2(21,900) X 208 M = 1 = 1 = 0.757 1 + f 1 + 0.32 ISCA = AVAILABLE FROM UTILITY X M = 48,500 X 0.757 = 36,715 AMPS ISCA = 36,715 AMP AT MAIN # 3 DISCONNECT SERVICE FEEDER: #500 NUMBER OF CONDUCTORS PER PHASE: 1 CONDUCTOR LENGTH "L ": 170' CONDUCTOR "C" VALUE: 21,900 1,73 X L X 1 = 1,73 X 170 X 36,715 = 2.37 C X EL -L 21,900 X 208 M = 1 = 1 = 0.296 1 +f 1 +2.37 ISCA = AVAILABLE FROM UTILITY X M = 36,715 X 0.296 = 10,868 AMPS ISCA = 10,868 AMPS AT PANEL 'EC3' a•1• •1• • • Y•• ♦♦ Y€'�1• a1• • a •••ia ••• • • • r• •u r •• • • • • • •Y • • • • • Y f • •r•Ywi • • • U Y a•i!• CONDUCTOR "C" VALUE: 11,100 1,73 _X L X1_ = 1,73 X 125 X 40,061 = 3.75 C X EL -L 11,100 X 208 5.5 M = 1 = 1 = 0.21 3390 Mary Street, Suite 216 1 + f 1 + 3.75 Miami Florida 33133 USA ISCA = AVAILABLE FROM UTILITY X M = 40,061 X 0.21 = 8,413 AMPS ISCA = 8,413 AMPS AT PANEL 'A3' X 0.153 = 3,020 AMPS ISCA = 3,020 AMPS AT PANEL 'LS' Associate Architect • • • • • • • • • • r • • • r • r • r • • • • . ... • Ir• • . . ... 'Y• ' '• 1 i • • • • i • U 1 • • • • • • f ! • • U U U • • U o .... . • ♦••• • U•• • •••b PANEL 'A3' FAULT CURRENT CALCULATION: SERVICE FEEDER: #500 NUMBER OF CONDUCTORS PER PHASE: 3 CONDUCTOR LENGTH "L ": 35' CONDUCTOR "C" VALUE: 21,900 1,73 X L X 1 = 1,73 X _35X 48,500- - 0.21 C X EL -L 3(21,900) X 208 1 M - 1 = 0.826 1 + f 1 + 0.21 ISCA = AVAILABLE FROM UTILITY X M = 48,500 X 0.826 = 40,061 AMPS ISCA = 30,701 AMP AT MAIN # 1 DISCONNECT SERVICE FEEDER: #3/0 NUMBER OF CONDUCTORS PER PHASE: 1 CONDUCTOR LENGTH "L ": 100' CONDUCTOR "C" VALUE: 11,100 1,73 X L X 1 _ 1 73 X 100 X 40,06 = - 3,00 C X EL -L 11,100 X 208 1.454 M _ 1 1 = 0.25 Owner _ __ 1+ f 1+ 3 ISCA = AVAILABLE FROM UTILITY X M = 40,061 X 0.25 = 10,015 AMPS ISCA = 10,015 AMPS AT PANEL 'A2' X 0.407 = 19,740 AMPS SERVICE FEEDER: #3/0 NUMBER OF CONDUCTORS PER PHASE: 1 CONDUCTOR LENGTH "L ": 125' CONDUCTOR "C" VALUE: 11,100 1,73 _X L X1_ = 1,73 X 125 X 40,061 = 3.75 C X EL -L 11,100 X 208 5.5 M = 1 = 1 = 0.21 3390 Mary Street, Suite 216 1 + f 1 + 3.75 Miami Florida 33133 USA ISCA = AVAILABLE FROM UTILITY X M = 40,061 X 0.21 = 8,413 AMPS ISCA = 8,413 AMPS AT PANEL 'A3' X 0.153 = 3,020 AMPS PANEL 'LS' FAULT CURRENT CALCULATION: SERVICE FEEDER: #3/0 NUMBER OF CONDUCTORS PER PHASE: 1 CONDUCTOR LENGTH "L ": 40' CONDUCTOR "C" VALUE: 11,100 1,73 X L X 1 - 1,73 X 40 X 48-500 = 1.454 C X EL -L 11,100 X 208 Owner M = 1 = 1 = 0.407 1 + f 1 + 1.454 General Contractor ISCA = AVAILABLE FROM UTILITY X M = 48,500 X 0.407 = 19,740 AMPS ISCA = 19,740 AMP AT LS MAIN DISCONNECT SERVICE FEEDER: #3 NUMBER OF CONDUCTORS PER PHASE: 1 CONDUCTOR LENGTH "L ": 130' CONDUCTOR "C" VALUE: 3,880 1,73 X L X 1 = 1,73 X 130 X 19,740 - 5.5 C X EL -L 3,880 X 208 3390 Mary Street, Suite 216 1 1 M __ _ 0.153 Miami Florida 33133 USA __ 1 + f 1 + 5.5 T: 305.461.9480 F: 305.461.3686 ISCA = AVAILABLE FROM UTILITY X M = 19,740 X 0.153 = 3,020 AMPS ISCA = 3,020 AMPS AT PANEL 'LS' Associate Architect ••• u u • u u • u u • t LARKING HOSPITAL EMERGENCY DEP. ..` INTERIOR RENOVATION 7031 S.W. 62nd AVE. SOUTH MIAMI, FLORIDA 33143 Owner General Contractor LEDA DALY NTEREORS II • EST. 1515 3390 Mary Street, Suite 216 Miami Florida 33133 USA T: 305.461.9480 F: 305.461.3686 Architect Associate Architect m�6m�mV6�4 PQmm�lm6 ( #6�(�tiQQSQQ P.E. No 57468 David Guirola Electric2l Engineer p p ID p p ZZ plroa�eQOmm ©a 13850 •r2I Way Suits k203MiMi,FL33145 9mdomRIMOMN TMM1 PH:(305)a54 -S224 FAX(305)857 -6601 CA 0000 324 1 /4 sc�Te:1 -0 061 -10026 -000 Architects project Number Drawing Issue REVISIONS NO. DESCRIPT10N DATE LEO A DALY COTANY Copyright 2007 �'• i i 5 Y ' .•/ , �a Seel ELECTRICAL RISER AND LEGEND sheet Title Shoat Number