Loading...
10-685-037le" 22 BY X 211 30" le 3" X 2" USE OF 2" WIDE 22 gauge 21x 15" hangers may be substituted for 3" hangers for ducts with widths not over 48 and depths not over 24" provided that not more than one joint occurs between hangers and the maximum hanger spacing Oft. Exception: When duct perimeter is e0" or. less and does not require reinforcement two joints are permitted bet hangers e en ha s 0 AIR VENT FLANGED UNION (TYP.) SITE iNVE ST iGAT i ON NOTE EXAMINATION OF CONTRACT DOCUMENTS AND SITE OF WORK: THE BIDDER 1S REQUIRED, BEFORE SUBMITTING HiS PROPOSAL, TO VISIT THE SITE OF THE PROPOSED WORK AND FAMILIARIZE HIM OR HERSELF WiTH THE NATURE AND EXTENT OF THE WORK AND ANY LOCAL CONDITIONS THAT MAY IN ANY MANNER AFFECT THE WORK TO BE DONE AND EQUIPMENT, MATERIALS AND LABOR REQUIRED THEREFORE. SINCE THE WORK INVOLVES NEW AND/OR EXISTING BUILDINGS, SYSTEMS AND FACILITIES, SPECIAL CONSIDERATION SHALL BE GIVEN TO EXAMINATION OF WORKING CONDITIONS, NEW FACILITIES AND ALL BUILDING STRUCTURES FAMILIARIZE TO HIMSELF WiTH ALL EXISTING CONDITIONS. SLIGHT VARIATION OF ROUTING AND OR CONSTRUCTIONS SHOULD BE ANTICIPATED BY THIS CONTRACTOR TO AVOID CONFLICTS WITH OTHER TRADES. THESE VARIATIONS ARE EXPRESSLY INCLUDED AS PART OF THE WORK WHENEVER REQUIRED AT NO ADDITIONAL COST TO THE OWNER. IGNORANCE ON THE PART OF THE CONTRACTOR WiLL IN NO WAY RELIEVE HIM OF THE OBLIGATIONS AND RESPONSIBILITY ASSUMED UNDER THIS CONTRACT. BALANCING VALVE PRE55. TEMP. TEST PORT (TYP.) CONTTREOL VALV GAUGE COCK CIRCUIT SETTER BALANCING VALVE W/ TEST PORT. I G"WS BUTTERFLY VALVE (TYP.) 3/4" DRAIN Y STRAINER W/ BLOW -OFF BALL HOSE -BIBS VALVE VALVE AHU =7 CONNECTION DETAIL . N.T.S. iN CASE OF FIRE ALARM ACTIVATION VIA SMOKE DETECTOR OR VIA FLOW SWITCH ALL EXHAUST FANS AND FAN COIL SERViNG THIS AREA SHALL SHUT -DOWN. Maximum Hanger Duct size, incites Spacing 48: Wide or orator 4 ft Less tha 4e" wide Eft and less than 48" 1 4" deep 113 Width between 28" Eft 4 4e" and greater 1 than 16" deep Extension is Less than 29" wide - eft and 4" depth or less ' le" 22 BY X 211 30" le 3" X 2" USE OF 2" WIDE 22 gauge 21x 15" hangers may be substituted for 3" hangers for ducts with widths not over 48 and depths not over 24" provided that not more than one joint occurs between hangers and the maximum hanger spacing Oft. Exception: When duct perimeter is e0" or. less and does not require reinforcement two joints are permitted bet hangers e en ha s 0 AIR VENT FLANGED UNION (TYP.) SITE iNVE ST iGAT i ON NOTE EXAMINATION OF CONTRACT DOCUMENTS AND SITE OF WORK: THE BIDDER 1S REQUIRED, BEFORE SUBMITTING HiS PROPOSAL, TO VISIT THE SITE OF THE PROPOSED WORK AND FAMILIARIZE HIM OR HERSELF WiTH THE NATURE AND EXTENT OF THE WORK AND ANY LOCAL CONDITIONS THAT MAY IN ANY MANNER AFFECT THE WORK TO BE DONE AND EQUIPMENT, MATERIALS AND LABOR REQUIRED THEREFORE. SINCE THE WORK INVOLVES NEW AND/OR EXISTING BUILDINGS, SYSTEMS AND FACILITIES, SPECIAL CONSIDERATION SHALL BE GIVEN TO EXAMINATION OF WORKING CONDITIONS, NEW FACILITIES AND ALL BUILDING STRUCTURES FAMILIARIZE TO HIMSELF WiTH ALL EXISTING CONDITIONS. SLIGHT VARIATION OF ROUTING AND OR CONSTRUCTIONS SHOULD BE ANTICIPATED BY THIS CONTRACTOR TO AVOID CONFLICTS WITH OTHER TRADES. THESE VARIATIONS ARE EXPRESSLY INCLUDED AS PART OF THE WORK WHENEVER REQUIRED AT NO ADDITIONAL COST TO THE OWNER. IGNORANCE ON THE PART OF THE CONTRACTOR WiLL IN NO WAY RELIEVE HIM OF THE OBLIGATIONS AND RESPONSIBILITY ASSUMED UNDER THIS CONTRACT. BALANCING VALVE PRE55. TEMP. TEST PORT (TYP.) CONTTREOL VALV GAUGE COCK CIRCUIT SETTER BALANCING VALVE W/ TEST PORT. I G"WS BUTTERFLY VALVE (TYP.) 3/4" DRAIN Y STRAINER W/ BLOW -OFF BALL HOSE -BIBS VALVE VALVE AHU =7 CONNECTION DETAIL . N.T.S. iN CASE OF FIRE ALARM ACTIVATION VIA SMOKE DETECTOR OR VIA FLOW SWITCH ALL EXHAUST FANS AND FAN COIL SERViNG THIS AREA SHALL SHUT -DOWN. TF -1 MANUFAC. GRENHECK TYPE IN LINE CFM CHANNEL SECTION STATIC FIRE55UiRE IN. 1 4" H.P. 113 If Total Minimum Minimum 1 RPM Extension is Channel Channel WANCsERS AND SUFF'OIR S iw �/ not greater than: Gauge Profile f_ f I� 6 +' 24 3" X 1.51, C2~I'1 le" 22 BY X 211 30" le 3" X 2" USE OF 2" WIDE 22 gauge 21x 15" hangers may be substituted for 3" hangers for ducts with widths not over 48 and depths not over 24" provided that not more than one joint occurs between hangers and the maximum hanger spacing Oft. Exception: When duct perimeter is e0" or. less and does not require reinforcement two joints are permitted bet hangers e en ha s 0 AIR VENT FLANGED UNION (TYP.) SITE iNVE ST iGAT i ON NOTE EXAMINATION OF CONTRACT DOCUMENTS AND SITE OF WORK: THE BIDDER 1S REQUIRED, BEFORE SUBMITTING HiS PROPOSAL, TO VISIT THE SITE OF THE PROPOSED WORK AND FAMILIARIZE HIM OR HERSELF WiTH THE NATURE AND EXTENT OF THE WORK AND ANY LOCAL CONDITIONS THAT MAY IN ANY MANNER AFFECT THE WORK TO BE DONE AND EQUIPMENT, MATERIALS AND LABOR REQUIRED THEREFORE. SINCE THE WORK INVOLVES NEW AND/OR EXISTING BUILDINGS, SYSTEMS AND FACILITIES, SPECIAL CONSIDERATION SHALL BE GIVEN TO EXAMINATION OF WORKING CONDITIONS, NEW FACILITIES AND ALL BUILDING STRUCTURES FAMILIARIZE TO HIMSELF WiTH ALL EXISTING CONDITIONS. SLIGHT VARIATION OF ROUTING AND OR CONSTRUCTIONS SHOULD BE ANTICIPATED BY THIS CONTRACTOR TO AVOID CONFLICTS WITH OTHER TRADES. THESE VARIATIONS ARE EXPRESSLY INCLUDED AS PART OF THE WORK WHENEVER REQUIRED AT NO ADDITIONAL COST TO THE OWNER. IGNORANCE ON THE PART OF THE CONTRACTOR WiLL IN NO WAY RELIEVE HIM OF THE OBLIGATIONS AND RESPONSIBILITY ASSUMED UNDER THIS CONTRACT. BALANCING VALVE PRE55. TEMP. TEST PORT (TYP.) CONTTREOL VALV GAUGE COCK CIRCUIT SETTER BALANCING VALVE W/ TEST PORT. I G"WS BUTTERFLY VALVE (TYP.) 3/4" DRAIN Y STRAINER W/ BLOW -OFF BALL HOSE -BIBS VALVE VALVE AHU =7 CONNECTION DETAIL . N.T.S. iN CASE OF FIRE ALARM ACTIVATION VIA SMOKE DETECTOR OR VIA FLOW SWITCH ALL EXHAUST FANS AND FAN COIL SERViNG THIS AREA SHALL SHUT -DOWN. OUTSIDE AIR INTAKE CALCULATIONS AS PER ASHRAE -62 -2001 is FBC -2004. AHU- 7 1057 SF NURSE STATION 0 890 SF CORRIDORS O 872 SF OFFICE AREA CALCULATIONS 1057 X 10 X 15 — 159 CFM O.A.1. 1000 Q 890 X 0.1 = 89 CFM O.A.I. O 1000 X 7 X 20 122 CFM O.A.I. 370 CFM O.A.I. REQUIRED 370 CFM O.A.I. PROVIDED FAN SCHEDULE ITEM TF -1 MANUFAC. GRENHECK TYPE IN LINE CFM 600 STATIC FIRE55UiRE IN. 1 4" H.P. 113 VOLTS 115 see 1 RPM 1835 REFERENCE MODEL BSQ -80 REMARKS 1 THERMOSTAT CONDENSING UNIT - r OUTSIDE AIR INTAKE CALCULATIONS AS PER ASHRAE -62 -2001 is FBC -2004. AHU- 7 1057 SF NURSE STATION 0 890 SF CORRIDORS O 872 SF OFFICE AREA CALCULATIONS 1057 X 10 X 15 — 159 CFM O.A.1. 1000 Q 890 X 0.1 = 89 CFM O.A.I. O 1000 X 7 X 20 122 CFM O.A.I. 370 CFM O.A.I. REQUIRED 370 CFM O.A.I. PROVIDED FAN SCHEDULE ITEM TF -1 MANUFAC. GRENHECK TYPE IN LINE CFM 600 STATIC FIRE55UiRE IN. 1 4" H.P. 113 VOLTS 115 PHASES 1 RPM 1835 REFERENCE MODEL BSQ -80 REMARKS 1 MECHANICAL PLAN PHASE 5 1. The contractor shall furnish all labor, material and equipment for a complete H.V.A.C. system in accordance with these drawings. The Florida Building Cods 2004 and the latest edition of the following publications: (a )ANS B9.1 Mechanical Refrigeration (b) NFPA Pamphlets 90A k 91 c) SMACNA (d) ASHRAE. 2. All air conditioning ductwork shall be gmd(26g@) with I" exterior wrapped insulation. 3. All exhaust ductwork shall be code gage galvanized sheet metal. 4. Duct size shown are net free area inside. 5. All air devices (diffusers, registers and grilles) shall be all aluminum construction, with exposed surface chemically treated to receive paint to match color or AIRGUIDE or approved equal. 6. Provide opposed blade dampers at all diffusers and registers. •Y•V •YU • LEL;`EIS. •.f •'•.. Y • c Y Y • • •••• 00664, YYY Y••• • • . V • • V G • V • • • • • • Y • • • C • . Y. • • • • Y V Y • *000 f • f ♦ • • 000 • ***e u' • YYY • ` Y • EXISTING DUCT :Y•. •:L ----- - - ---- TO REMAIN EXISTING DUCT TO BE ELIMINATED NEW DUCT EXISTING RETURN OR EXHAUST GRILL TO REMAIN EXISTING RETURN OR V7 EXHAUST GRILL TO BE ELIMINATED NEW EXHAUST OR RETURN GRILL j j EXISTING SUPPLY GRILL TO REMAIN V. _.V EXISTING SUPPLY GRILL TO BE ELIMINATED • NEW SUPPLY GRILL SCOPE OF WRK FOR PHASE 5 - INSTALL EXHAUST GRILL CONNECTED TO TF -I IN AREA OF WORK TO MAINTAIN NEGATIVE PRESSURE. - INSTALL NEW SUPPLY AND RETURN GRILLS AS SHOW IN PLANS. 7. Thermostats shall be combination cooling /heating with system Cool /Auto /Heat /Off and Fan On /Auto selector switches. - CONNECT THE RETURN DUCT UNFINISHED IN 8- Air filters for replaced fan coils shall be two beds type, filter No.1 PHASE 3 TO MECHANICAL ROOM W/NEW FIRE 3OX efficiency, Mery 8, filter No.2 9OX efficiency, Mery 14. DAMPER 14 GA. LiNK ( R/A PLENUM FILTER CUBIC L32XB 11—PULL OUT SPACE LINED R/A DUCT - _ _ D ALL FOR101 MD(TAKE( ?E) 1 1 U.L. 555 FIRE DAMPER L _ J A r -1 COIL PULL COLLAR 1 \ / I I I OUTS ACE 42x8 FD ISD VD RECTANGULAR DUCT /X\ 30X8 FROM NURSE STATION, 40X20 S/A D CT I — — — — ACCESS DOOR � / \ I I I I FIRE DAMPER DETAIL —WALL - FD I V WR CCONNECT N.T.S. TO EXIST. MAIN ft/A SiDE PARTIAL PLAN AHU -1 SCALE: 1/2 " =1' -fd" AIR BALANCE CALCULATIONS MARK SUPPLY AIR RETURN AIR EXHAUST AiR UNDER CUT DOOR AIR OUTSIDE AIR INTAKE TO OTHER AREAS AHU -7 3000 2630 370 0 370 370 TOTAL EXH. 370 TOTAL INTAKE CALCULATION OF TEMPORARY FAN TO MAINTAIN NEGATIVE PRESSURE IN AREA OF WORK DURING CONSTRUCTION TIME (BASED ON PHASE 5 AS LARGER AREA). 5904 C.F AT 3 COMPLETE CHANGES PER HOURS 5904 X 3 – 300 CFM MINIMUN REQUIRED 60 600 CFM PROVIDED AHU —T LEGEND SIDE REGISTER TRANE 24X24 CD —(SEE SCHEDULE CEILING DIFFUSER AIR FLOW DUCT TO MATCH NECK SIZE TYP. CEILING GRILL �y CEILING GRILLE SEE SIZE SCHEDULE HEAT PUMP UNIT FiRE RATE ENCLOSURE DUCT TO MATCH NECK SIZE TYP. UNLESS OTHERWISE NOTED. FIRE RATED ROOF FLOOR CEILING ASSEMBLY RETURN AIR GRILL ROOF TOP UNIT + VOLUME DAMPER AIR HANDLER UNIT QQ THERMOSTAT CONDENSING UNIT DUCT MOUNTED SMOKE DETECTOR EXHAUST. FAN C2~I'1 SEE F.A. RISER FOR SPECS. GENERAL H• V.A.C. NOTES AIR FLOW DIRECTION ( ARROWS DENOTE --� 1 WAY, 2 WAY, ETC., SEE PLANS -�� RETURN OR EXHAUST, SEE PUNS. p WALL MOUNTED SIDE REGISTER, r Ln EXHAUST FAN OAJ OUTSIDE AIR INTAKE 1. The contractor shall furnish all labor, material and equipment for a complete H.V.A.C. system in accordance with these drawings. The Florida Building Cods 2004 and the latest edition of the following publications: (a )ANS B9.1 Mechanical Refrigeration (b) NFPA Pamphlets 90A k 91 c) SMACNA (d) ASHRAE. 2. All air conditioning ductwork shall be gmd(26g@) with I" exterior wrapped insulation. 3. All exhaust ductwork shall be code gage galvanized sheet metal. 4. Duct size shown are net free area inside. 5. All air devices (diffusers, registers and grilles) shall be all aluminum construction, with exposed surface chemically treated to receive paint to match color or AIRGUIDE or approved equal. 6. Provide opposed blade dampers at all diffusers and registers. •Y•V •YU • LEL;`EIS. •.f •'•.. Y • c Y Y • • •••• 00664, YYY Y••• • • . V • • V G • V • • • • • • Y • • • C • . Y. • • • • Y V Y • *000 f • f ♦ • • 000 • ***e u' • YYY • ` Y • EXISTING DUCT :Y•. •:L ----- - - ---- TO REMAIN EXISTING DUCT TO BE ELIMINATED NEW DUCT EXISTING RETURN OR EXHAUST GRILL TO REMAIN EXISTING RETURN OR V7 EXHAUST GRILL TO BE ELIMINATED NEW EXHAUST OR RETURN GRILL j j EXISTING SUPPLY GRILL TO REMAIN V. _.V EXISTING SUPPLY GRILL TO BE ELIMINATED • NEW SUPPLY GRILL SCOPE OF WRK FOR PHASE 5 - INSTALL EXHAUST GRILL CONNECTED TO TF -I IN AREA OF WORK TO MAINTAIN NEGATIVE PRESSURE. - INSTALL NEW SUPPLY AND RETURN GRILLS AS SHOW IN PLANS. 7. Thermostats shall be combination cooling /heating with system Cool /Auto /Heat /Off and Fan On /Auto selector switches. - CONNECT THE RETURN DUCT UNFINISHED IN 8- Air filters for replaced fan coils shall be two beds type, filter No.1 PHASE 3 TO MECHANICAL ROOM W/NEW FIRE 3OX efficiency, Mery 8, filter No.2 9OX efficiency, Mery 14. DAMPER 14 GA. LiNK ( R/A PLENUM FILTER CUBIC L32XB 11—PULL OUT SPACE LINED R/A DUCT - _ _ D ALL FOR101 MD(TAKE( ?E) 1 1 U.L. 555 FIRE DAMPER L _ J A r -1 COIL PULL COLLAR 1 \ / I I I OUTS ACE 42x8 FD ISD VD RECTANGULAR DUCT /X\ 30X8 FROM NURSE STATION, 40X20 S/A D CT I — — — — ACCESS DOOR � / \ I I I I FIRE DAMPER DETAIL —WALL - FD I V WR CCONNECT N.T.S. TO EXIST. MAIN ft/A SiDE PARTIAL PLAN AHU -1 SCALE: 1/2 " =1' -fd" AIR BALANCE CALCULATIONS MARK SUPPLY AIR RETURN AIR EXHAUST AiR UNDER CUT DOOR AIR OUTSIDE AIR INTAKE TO OTHER AREAS AHU -7 3000 2630 370 0 370 370 TOTAL EXH. 370 TOTAL INTAKE CALCULATION OF TEMPORARY FAN TO MAINTAIN NEGATIVE PRESSURE IN AREA OF WORK DURING CONSTRUCTION TIME (BASED ON PHASE 5 AS LARGER AREA). 5904 C.F AT 3 COMPLETE CHANGES PER HOURS 5904 X 3 – 300 CFM MINIMUN REQUIRED 60 600 CFM PROVIDED AHU —T S.R SIDE REGISTER TRANE CD CEILING DIFFUSER AIR FLOW CG CEILING GRILL 2081316!0 0 HP. HEAT PUMP UNIT FiRE RATE ENCLOSURE aox UNLESS OTHERWISE NOTED. FIRE RATED ROOF FLOOR CEILING ASSEMBLY R1U ROOF TOP UNIT FIRE STOPPING ANU AIR HANDLER UNIT SMOKE CONTROL CJ CONDENSING UNIT EF EXHAUST. FAN C2~I'1 CUBIC FEET PER MINUTE GENERAL H• V.A.C. NOTES 1. The contractor shall furnish all labor, material and equipment for a complete H.V.A.C. system in accordance with these drawings. The Florida Building Cods 2004 and the latest edition of the following publications: (a )ANS B9.1 Mechanical Refrigeration (b) NFPA Pamphlets 90A k 91 c) SMACNA (d) ASHRAE. 2. All air conditioning ductwork shall be gmd(26g@) with I" exterior wrapped insulation. 3. All exhaust ductwork shall be code gage galvanized sheet metal. 4. Duct size shown are net free area inside. 5. All air devices (diffusers, registers and grilles) shall be all aluminum construction, with exposed surface chemically treated to receive paint to match color or AIRGUIDE or approved equal. 6. Provide opposed blade dampers at all diffusers and registers. •Y•V •YU • LEL;`EIS. •.f •'•.. Y • c Y Y • • •••• 00664, YYY Y••• • • . V • • V G • V • • • • • • Y • • • C • . Y. • • • • Y V Y • *000 f • f ♦ • • 000 • ***e u' • YYY • ` Y • EXISTING DUCT :Y•. •:L ----- - - ---- TO REMAIN EXISTING DUCT TO BE ELIMINATED NEW DUCT EXISTING RETURN OR EXHAUST GRILL TO REMAIN EXISTING RETURN OR V7 EXHAUST GRILL TO BE ELIMINATED NEW EXHAUST OR RETURN GRILL j j EXISTING SUPPLY GRILL TO REMAIN V. _.V EXISTING SUPPLY GRILL TO BE ELIMINATED • NEW SUPPLY GRILL SCOPE OF WRK FOR PHASE 5 - INSTALL EXHAUST GRILL CONNECTED TO TF -I IN AREA OF WORK TO MAINTAIN NEGATIVE PRESSURE. - INSTALL NEW SUPPLY AND RETURN GRILLS AS SHOW IN PLANS. 7. Thermostats shall be combination cooling /heating with system Cool /Auto /Heat /Off and Fan On /Auto selector switches. - CONNECT THE RETURN DUCT UNFINISHED IN 8- Air filters for replaced fan coils shall be two beds type, filter No.1 PHASE 3 TO MECHANICAL ROOM W/NEW FIRE 3OX efficiency, Mery 8, filter No.2 9OX efficiency, Mery 14. DAMPER 14 GA. LiNK ( R/A PLENUM FILTER CUBIC L32XB 11—PULL OUT SPACE LINED R/A DUCT - _ _ D ALL FOR101 MD(TAKE( ?E) 1 1 U.L. 555 FIRE DAMPER L _ J A r -1 COIL PULL COLLAR 1 \ / I I I OUTS ACE 42x8 FD ISD VD RECTANGULAR DUCT /X\ 30X8 FROM NURSE STATION, 40X20 S/A D CT I — — — — ACCESS DOOR � / \ I I I I FIRE DAMPER DETAIL —WALL - FD I V WR CCONNECT N.T.S. TO EXIST. MAIN ft/A SiDE PARTIAL PLAN AHU -1 SCALE: 1/2 " =1' -fd" AIR BALANCE CALCULATIONS MARK SUPPLY AIR RETURN AIR EXHAUST AiR UNDER CUT DOOR AIR OUTSIDE AIR INTAKE TO OTHER AREAS AHU -7 3000 2630 370 0 370 370 TOTAL EXH. 370 TOTAL INTAKE CALCULATION OF TEMPORARY FAN TO MAINTAIN NEGATIVE PRESSURE IN AREA OF WORK DURING CONSTRUCTION TIME (BASED ON PHASE 5 AS LARGER AREA). 5904 C.F AT 3 COMPLETE CHANGES PER HOURS 5904 X 3 – 300 CFM MINIMUN REQUIRED 60 600 CFM PROVIDED AHU —T YES MANUF. TRANE MODEL LPCAD08P AIR FLOW 3000 CFM ELECT. SERVICE 2081316!0 0 WATER CONN. 1 -1 2" CWS, CWR HVAC DESIGN REQUIRE: YES NO DUCT SMOKE DETECTOR X FIRE DAMPERS) X SMOKE DAMPERS X FiRE RATE ENCLOSURE X FIRE RATED ROOF FLOOR CEILING ASSEMBLY X FIRE STOPPING X SMOKE CONTROL X tiro Yry f^ ■a0�1gIR�l maml� mama �taa><ala�a P.E. No 5328E Jose Antonio Mendez. Professional Engineer m Q m m 0 II �omff�eelmm�a 1385 Coral Way Suite *203 Miami, FL 33145 PH:(305)854 -9824 FAX(305)856 -1797 . jose01188891./Mm CA 00008324 r � r r ♦ .Y .-LARKING HOSPITAL • �•W ,EMERGENCY DEP. INTERIOR RENOVATION l � Y Y i • • : 7031 S.W. 62nd AVE • ° t0(J11i • MIAMI. FLORIDA 33143 General Contractor K-DADA V IN TER e0RSNG E • EST. 1915 3390 Mary Street, Suite 216 Miami Florida 33133 USA T. 305.461.9480 F: 305.461.3686 Architect A9eeciete Architect soil: 061- 10026 -000 Arehitects Pre*t Number Drawing Issue REVISIONS NO. DESCRIPTION DATE Shoat Number