Loading...
10-685-002y GENERAL NOTES TAPED, TROWELED AND POLISHED. ALL OUTSIDE CORNERS AT PARTITIONS SHALL HAVE CORNER BEADS OR ALL BEADS AS APPLICABLE. GENERAL SYMBOLS,- INDEX OF DRAWINGS 'gee REFERENCE DETAIL NUMBER DETAIL REFERENCE: SHEET WHERE DETAIL IS DRAWN. TITLES: SHEET WHERE DETAIL IS FIRST REFERENCED 0 SUB -TITLE -- BUILDING SECTION SECTION OR REFERENCE DOOR OR WINDOW FRAME SECTION ELEVATION (WHERE ONLY ONE IS REFERENCED) A <: a INTERIOR ELEVATION (SOLID INDICATES VIEWS REFERENCED) --- — MATCH LINE COLUMN LINE �--^ -� LIM PROJECT LIMIT LINE ^m �_ EXISTING TO REMAIN — T TO BE DEMOLISHED XXXXX ROOM NAME XXXXX XXXX ROOM NUMBER XXX PROGRAM AREA XXX ACTUAL AREA DOOR REFERENCE WINDOW REFERENCE ❑1 NOTE REFERENCE 1 S2 PARTITION TYPE REFERENCE AREVISION REFERENCE TOP OF PARAPET ELEVATION REFERENCE EL =233' -2" A COLUMN NUMBER OR LETTER (EXISTING CONST.) XXX EQUIPMENT REFERENCE LIFE SAFETY SYMBOLS A4 GENERAL CONIE&MR AND CTO S SCHEDULES, ORGANIZING AND COORDINATION GENERAL NOTES 4" 146 GENERAL RESPONSIBILITIES COORDINATE WITH BUILDING MANAGER AND BUILDING THIS PROJECT SHALL CONFORM TO ALL STATE AND LOCAL T2" 360 d EXIT CAPACITY (HORIZONTAL) OCCUPANTS FOR USE OF POWER, WORKING HOURS, CODES AND ORDINANCES WHICH TAKE PRECEDENCE OVER - 1 -FS EACH CONTRACTOR AND SUBCONTRACTOR SHALL VISIT THE 517E ROUTES FOR WORKMAN'S TRAVEL, LOCATIONS OF DRAWINGS. ANY DEVIATION AND /OR SUBSTITUTION FROM ABOVE FINISH FLOOR AND EXISTING FACILITIES TO DETERMINE THE EXTENT OF WORK. DUMPSTERS AND CONSTRUCTION VEHICLES, ETC. THE INFORMATION AND INSTRUCTIONS PROVIDED HEREIN Q IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO MAT SHALL BE SUBMITTED TO THE ARCHITECT FOR HIS VERIFY EXISTING CONDITIONS AND TO MAKE ALLOWANCE FOR THE CONTRACTOR SHALL PREPARE THE JOB SITE APPROVAL PRIOR TO THE PERFORMANCE OF THE WORK. MAXIMUM THEM PRIOR TO ANY CONSTRUCTION. PARTITION LAYOUT FOR REVIEW OF ARCHITECT PRIOR TO BUILDING MET METAL ERECTING PARTITIONS. FILL AND SEAL PENETRATIONS TO FIRE MARSHALL, FLORIDA PREVENTION CODE -2001 GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL REVIEW MAINTAIN FIRE RATINGS. EDITION, AND FIRE PROTECTION DRAWINGS PRIOR TO CONSTRUCTION AND REPORT ANY N DISCREPANCIES ENCOUNTERED. THE ARCHITECT / ENGINEER CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING ALL NEW WORK SHALL BE PERFORMED TO MEET THE SHOULD BE NOTIFIED IN WRITING 7 DAYS PRIOR TO AND IMPLEMENTING ALL WORK SO AS NOT TO DISRUPT FLORIDA FIRE PREVENTION CODE -2004 EDITION NO SUBMITTING HIS DID. OR INCONVENIENCE THE EXISTING OCCUPANTS OR CONCRETE NIC ADJOINING OCCUPANTS. PROVIDE 4A -605 UL -RATED FIRE EXTINGUISHER FOR j GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND N EACH AREA OF TENANT SPACE UP TO 3,000 S.F. WHICH Drawing Issue REPORT ANY DISCREPANCIES TO THE ARCHITECT. ALL ACTIVITIES GENERATING EXCESSIVE NOISE, WHICH IS NOT WITHIN 75 FEET OF THE NEAREST M COMMON MON REVISIONS WOULD INTERFERE WITH TENANTS RIGHTS TO OCCUPANCY, BUILDING EXTINGUISHER (NFPA 10 3 -EST ADDITION, , THE CONTRACTOR IS TO ACQUIRE ALL REQUIRED PERMITS FOR MUST BE SCHEDULED AFTER NORMAL WORKING HOURS. PROVIDE AND LOCATE EXTING EXTINGUISHERS IN ADDITIONAL G DETAIL THE DEMOLITION, CONSTRUCTION AND OCCUPANCY OF THE NUMBERS AND LOCATIONS REQUIRED BY LOCAL DN PROJECT. ANY DISRUPTION OF BUILDING UTILITIES WHICH WOULD AUTHORITY. REUSE EXISTING OR OWNER'S STOCK WHERE DR IMPACT OCCUPIED AREAS MUST BE SCHEDULED AFTER POSSIBLE. OBTAIN FIRE MARSHALL'S APPROVAL OF PLYWOOD ALL WORK DONE UNDER THE SUPERVISION OF THE NORMAL WORKING HOURS. LOCATIONS. AT A MINIMUM PROVIDE TWO PT CONTRACTOR SHALL BE IN A NEAT AND WORKMANLIKE MANNER EXTINGUISHERS -ONE LOCATED NEAR FRONT EXIT IN AN EXISTING AND IN ACCORDANCE WITH ALL GOVERNING AGENCIES, RULES FINISH NOTES OBVIOUS LOCATION AND THE SECOND LOCATED NEAR THE EC AND REGULATIONS HAVING JURISDICTION. R REAR OR SECONDARY EXIT IN AN OBVIOUS LOCATION. F ALL NEW MATERIALS AND /OR PATCHWORK SHALL BE ALL EXTINGUISHERS TO HAVE UPDATED INSPECTION THE CONTRACTOR IS TO PROVIDE ALL THE SUPPLEMENTARY PROVIDED TO MATCH EXISTING MATERIALS AND /OR LABELS. SC MATERIALS REQUIRED TO PROPERLY INSTALL, SUPPORT, BRACE ADJOINING WORK. *j l ti a ., � „ • �+ Cry April 2nd; 2008 AND SHORE ALL BUILDING COMPONENTS WITHIN THE SCOPE OF ICORE 11',0ING U T' ALL PENETRATIONS IN FIRE RATED ASSEMBLIES SHALL BE FIN THE PROJECT. ALL GYPSUM BOARD WALLS SHALL RECEIVE ONE COAT SEALED WITH MATERIALS APPROVED BY GOVERNING FL LATEX PRIMER AND TWO COATS INTERIOR LATEX PAINT, AGENCIES MEETING UL (OR EQUAL) SPECIFICATIONS s G110t SIMILAR,�7[- �lIGTU'�A�' �� ALL PRODUCTS SHALL BE INSTALLED PER MANUFACTURER'S SEE PAINT SPECIFIED ON FINISH SCHEDULE. INCLUDING INSTALLATION SYSTEM. ALL DUCTS SQ RECOMMENDATIONS. Sheet PENETRATING FIRE RATED ASSEMBLIES SHALL RECEIVE ST CONCRETE SLABS SHALL BE TROWELED SMOOTH. FIRE DAMPERS. GWB THESE DRAWINGS DO NOT SHOW EVERY MINOR DETAIL OF STD STANDARD ✓ / V, y ,a CONSTRUCTION. THE CONTRACTOR SHALL FURNISH AND ALL DOORS AND WOOD TRIM SHALL BE PAINT GRADE ALL EXIT DOORS SHALL HAVE HARDWARE PER N.F.P A. INSTALL ALL ITEMS REQUIRED FOR A COMPLETE BUILDING UNLESS OTHERWISE SPECIFIED. STANDARDS. ALL EXIT DOOR LOCKS SHALL HAVE THUMB VB SYSTEM AND SHALL PROVIDE ALL REQUIREMENTS FOR ALL LATCHES REQUIRING LESS THAN AN 180 DEGREE TURN. EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER. PROVIDE CAULKING AT ALL INTERIOR NON - MOVING JOINTS ENTRY LOCKS SHALL NOT REQUIRE UNLOCKING FOR HC HOLLOW CORE (WINDOW FRAMES, DOOR FRAMES, CEILING GRID/WALL EXITING FROM OCCUPIED SPACE WHEN USED IN EACH CONTRACTOR AND SUBCONTRACTOR SHALL BE JOINTS, CABINETRY SEAMS, ETC.). CAULK TO MATCH CONJUNCTION WITH DEAD BOLTS. RESPONSIBLE FOR THE SAFETY AND WELL-BEING OF HIS ADJOINING MATERIALS IF NOT PAINTED. CLEAN ALL W EMPLOYEES AND ALL CONSTRUCTION SAFETY REGULATIONS JOINTS AND PRIME AS NEEDED FOR FULL ADHESION. FLORIDA ACCESSIBILITY CODE FOR BUILDING INCLUDING OSHA ARE TO BE STRICTLY FOLLOWED. CAULKED JOINTS SHALL NOT EXCEED 1 /8 ". REWORK CONSTRUCTION FBC -2004 EDITION AND CODE IN INC AND REALIGN MATERIALS UNTIL SEAMS ARE 1/8" OR COMPLIANCE ALL CONTRACTORS AND SUBCONTRACTORS SHALL BE LESS. MICA TO MICA 1/16 ". WD WOOD CURRENTLY LICENSED IN THE STATE OF FLORIDA, DADE INT ALL NEW WORK SHALL BE PERFORMED TO MEET ALL COUNTY AND LOCAL CITIES IF REQUIRED. PROVIDE COPIES OF PROVIDE FLOOR PREPARATION TO RECEIVE NEW FLOOR APPLICABLE CITY, COUNTY AND STATE BUILDING CODES. LICENSES TO OWNER PRIOR TO COMMENCEMENT OF WORK. FINISH. THIS SHALL INCLUDE FLASH PATCHING AND EXISTING IMPROVEMENTS AND COMPONENTS SHALL BE THE CONTRACTOR SHALL REPAIR AND PAINT EXISTING LEVELING AT DOORWAYS, PERIMETERS AND SIMILAR AREAS WHICH MIGHT BE OBVIOUS TO THE TENANT. MODIFIED OR REWORKED AS NECESSARY AND PRACTICAL SURFACES DAMAGED BY DEMOLITION COVERED WITHIN THE IN ORDER THAT AT THE TIME OF COMPLETION ALL CONTRACT DOCUMENTS. ALL FINISH WOOD SHALL RECEIVE A STAIN PLUS TWO COMPONENTS MEET ALL APPLICABLE CODES. THIS COATS OF CLEAR SATIN URETHANE VARNISH. PROVIDE REQUIRES AT A MINIMUM THE FOLLOWING: THE CONTRACTOR SHALL COORDINATE AND SCHEDULE THE SAMPLES FOR OWNER'S SELECTION UNLESS OTHERWISE WORK OF ALL TRADES TO INSURE THE WORK IS COMPLETED IN SCHEDULED, a. ALL FIRE WALLS (NEW AND EXISTING BE SEALED AND j A TIMELY MANNER COMPLYING WITH THE.OWNER /CONTRACTOR PATCHED WITH PROTECTED PENETRATIONS, PER U.L AGREEMENT. PROVIDE FINISH AS SCHEDULED OR NOTED. OTHERWISE ASSEMBLY SPECIFICATIONS, CONFORM TO BUILDING STANDARDS. PRIOR TO COMMENCEMENT OF WORK, THE CONTRACTOR SHALL b. ALL EXISTING PIPES, CONDUITS, WIRES AND DUCTS BE VERIFY LOCATION OF ALL EQUIPMENT AND UTILITIES TO BE HARDWARE NOTES OF THE PROPER MATERIAL AND SIZE, AND BE PROPERLY REMOVED. REMOVALS SHALL BE COORDINATED WITH THE INSTALLED TO MEET CODE. EXISTING NON - COMPLIANT OWNER AND ALL BUILDING AND OTHER AUTHORITIES HAVING ALL ENTRY HARDWARE MUST BE RE -KEYED AT THE TIME ITEMS SHALL BE REPLACED, UNLESS SPECIFICALLY NOTED JURISDICTION. IF SO DIRECTED THE CONTRACTOR SHALL OF TURNOVER TO CLIENT. LOCKSMITH WILL PROVIDE OTHERWISE ON PLANS AS EXISTING AND NOT TO BE INCLUDE ANY ADDITIONAL COST TO HIS BID. KEYS DIRECTLY TO THE CLIENT. CONTRACTOR AND REPLACED. SUBCONTRACTORS ARE NOT TO BE PROVIDED COPIES OF THE CONTRACTOR SHALL PROVIDE AN ON SITE DUMPSTER IN A ENTRY KEYS. c. ALL WALLS, CEILING GRIDS, LIGHTS, CONDUITS, PIPES, LOCATION APPROVED BY THE OWNER FOR THE DISPOSAL OF DUCTS AND WIRES, WHETHER NEW OR EXISTING, TO BE REMOVED MATERIAL ! CLEANING REQUIREMENTS BRACED, STRAPPED, AND /OR SUPPORTED PER CODE, U.L AND MANUFACTURER SPECIFICATIONS. THE CONTRACTOR SHALL ESTABLISH A SCHEDULE FOR THE JOB SITE SHALL BE MAINTAINED IN A SAFE AND DEMOLITION PROCEDURES AND OPERATIONAL SEQUENCE FOR NEAT CONDITION AT ALL TIMES. BROOM CLEANING SHALL ALL FIXTURES AND HARDWARE SHALL COMPLY WITH THE LL C C REVIEW AND ACCEPTANCE OF THE OWNER, BE PERFORMED AS NEEDED TO AVOID DEBRIS BUILD UP. FLORIDA BUILDING CODE -2004 EDITION, CHAPTER IA 11- FLORIDA ACCESSIBILITY CODE FOR BUILDING GENERAL CONTRACTOR SHALL ESTABLISH SCHEDULE SHOWING ALL BUILDING MATERIALS SHALL BE STORED IN A SAFE CONSTRUCTION. THIS SHALL INCLUDE LEVER STYLE DOOR TIME OF DAY, AREA AND MEANS OF TRAVEL THROUGH AND ORGANIZED MANNER. HANDLES ON ALL DOORS WITH LATCHES, PREMISES FOR DISPOSAL OF DEBRIS FOR THE. OWNER. AT PROJECT COMPLETION, THE JOB SITE SHALL BE FULLY THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CLEANED AND TURNED OVER TO OCCUPANT READY FOR PROTECTION OF HIS WORK, INCLUDING BUT NOT LIMITED TO THEM TO MOVE IN AND BEGIN OPERATING WITHOUT ANY VANDALISM, THEFT, ETC, ADDITIONALLY, THE CONTRACTOR ADDITIONAL WORK OR CLEANING. THIS REQUIRES ALL SHALL BE RESPONSIBLE FOR THE OWNER AND HIS TENANTS' SURFACES TO BE CLEANED WITH APPROPRIATE CLEANING PROPERTY, INCLUDING BUT NOT LIMITED TO ANY DAMAGE, SOLUTIONS, VACUUMED, AND WAXED /SEALED AS CODE COMPLIANCE VANDALISM, THEFT, ETC. APPROPRIATE. ALL VCT SHALL BE SEALED AD WAXED. ALL MIRRORS, WINDOWS, HARDWARE, CABINETRY, WALL THE GENERAL CONTRACTOR SHALL PROVIDE THE ARCHITECT FINISHES AND FIXTURES ARE INCLUDED. WITH REDLINED AS -BUILT DRAWINGS FOR ANY AND ALL FIELD CHANGES AND /OR ADDITIONS TO THE WORK INCLUDED IN THE CONSTRUCTION NOTES DRAWINGS. TYPE 1 CONSTRUCTION PROJECT DATA WHERE DISSIMILAR METALS COME IN CONTACT, INSTITUTIONAL GROUP "I" ALL CONTRACTORS AND SUBCONTRACTORS SHALL CARRY THE CONTRACTOR IS TO PREVENT VIBRATIONS, AND NOISE FULLY SPRINKLED CODES: MINIMUM WORKMAN'S COMPENSATION, LIABILITY AND TRANSMISSION BETWEEN METALS AND ELECTROLYTIC AUTOMOBILE INSURANCE REQUIRED BY THE STATE OF FLORIDA ACTION. FLORIDA BUILDING CODE- -2Q07, NATIONAL AND HIGHER LIMITS IF REQUIRED BY THE OWNER. PROVIDE ELECTRICAL CODE LATEST EDITION, ALL OTHER INSURANCE CERTIFICATES TO OWNER BEFORE COMMENCEMENT PROVIDE DOUBLE STUDS AT ALL DOOR JAMBS. RULES, REGULATIONS AND CODES HAVING OF WORK. JURISDICTION INTERIOR PARTITIONS SHALL BE OF THICKNESS INDICATED PROVIDE STUD BACKING IN WALL CAVITY TO SUPPORT WALL ON DRAWINGS. NFPA 101 -2006 MOUNTED DOOR STOPS, GRAB BARS, AND MISC. ITEMS. COORDINATE HEIGHT ABOVE FLOOR. ALL GYPSUM BOARD TO BE USED IN WET AREAS SHALL FLORIDA ADMINISTRATIVE CODE CH 59A -3 BE MOISTURE RESISTANT TYPE AND TO RECEIVE TWO THE WORDING "ALIGN" DENOTES GYPSUM BOARD SHEATHING COATS OF EPDXY BASED PAINT. j UFAS ADA GUIDELINES FOR DESIGNS k OVER FACE OF BASE BUILDING COLUMNS AND WALL SURFACES CONSTRUCTION OF HEALTHCARE FACILITIES - 2006 AT JUNCTION WITH INTERIOR PARTITION TO ALIGN THE TWO ALL APPLICABLE RECOGNIZED NATIONAL CONSTRUCTION EDITION DISSIMILAR PARTS AND PROVIDE A SMOOTH CRACK -FREE INDUSTRY STANDARDS FOR MATERIALS AND INSTALLATION SURFACE (TYPICAL ALL CONDITIONS). SHALL BE A FULL PART OF THESE CONTRACT DOCUMENTS. ALL WORK SHALL BE PERFORMED TO MEET AND COMPLY WITH FLORIDA BUILDING CODE -2004 EDITION, CHAPTER 11- FLORIDA STRUCTURAL NOTES ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION. ALL DOORS IN RATED WALLS TO BE U.L LABELED, BOTH CONTRACTOR SHALL ACQUAINT HIMSELF WITH THESE DOCUMENTS AND THE SITE. ANY OVERSIGHT OF CONFLICTS DOOR AND JAMB, WITH U.L CLOSURES. LEGAL DESCRIPTION HEREIN NOT REPORTED IN WRITING TO THE ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY ARCHITECT /ENGINEER PRIOR TO BIDDING SHALL NOT ENTITLE SHALL BE FIRE TREATED. THE CONTRACTOR TO AN EXTRA. ALL GLASS WITHIN 4' -0" OF DOORS SHALL BE DIMENSIONS AS INDICATED ON THE DRAWINGS SHALL TAKE TEMPERED. PRECEDENCE OVER SCALING OF THE DRAWINGS. THE LARKIN CENTER PB 27 -67 LOTS 1 TO 9 k LOTS 18 -20 INC. BLK 1 LESS W110 DIMENSIONS INDICATED ON THE DRAWINGS ARE CALCULATED BY CONTRACTOR SHALL COORDINATE WITH OWNER'S CABINET FT OF LOTS 1- 18T -19 -20 LOT SIZE IRREGULAR OR 17546- 2896- 2899 -0297 COMPUTER AND ARE ROUNDED TO THE NEAREST INCH. THE SUB - CONTRACTOR AND SHALL SUPPLY ALL NECESSARY (15) LOCATION OF PARTITIONS TO THE CENTERS OF MULLIONS OR SUPPORTS AND BLOCKING REQUIRED, TO ALIGN WITH EXISTING WALLS SHALL TAKE PRECEDENCE OVER WRITTEN DIMENSIONS WHEN SO NOTED. ALL DIMENSIONS ALL DOORS, WINDOWS AND ROUGH OPENINGS SHALL BE SHALL BE FIELD VERIFIED. CONTRACTOR SHALL NOTIFY THE VERIFIED WITH MANUFACTURERS SPECIFICATIONS FOR ARCHITECT OF ANY DIMENSIONS THAT ARE IN CONFLICT WITH PROPER INSTALLATION. THE CONSTRUCTION DOCUMENTS. ALL INTERIOR WALLS SHALL RECEIVE 5/8" GYPSUM PROVIDE CHASE ENCLOSURES AS REQUIRED FOR ANY PIPING, BOARD, UNLESS OTHERWISE NOTED. ETC., GOING THROUGH AREA OF WORK AND NOT DENOTED ON PLANS. ALL WET AREAS SHALL RECEIVE 5/8" (MIN.) GYPSUM � BOARD MOISTURE RESISTANT. CONTRACTOR SHALL PROVIDE ACCESS PANEL FOR ALL VALVES, ETC., AS REQUIRED THROUGHOUT PROJECT, ALL GYPSUM BOARD WALLS AND CEILINGS SHALL BE TAPED, TROWELED AND POLISHED. ALL OUTSIDE CORNERS AT PARTITIONS SHALL HAVE CORNER BEADS OR ALL BEADS AS APPLICABLE. GENERAL SYMBOLS,- INDEX OF DRAWINGS 'gee REFERENCE DETAIL NUMBER DETAIL REFERENCE: SHEET WHERE DETAIL IS DRAWN. TITLES: SHEET WHERE DETAIL IS FIRST REFERENCED 0 SUB -TITLE -- BUILDING SECTION SECTION OR REFERENCE DOOR OR WINDOW FRAME SECTION ELEVATION (WHERE ONLY ONE IS REFERENCED) A <: a INTERIOR ELEVATION (SOLID INDICATES VIEWS REFERENCED) --- — MATCH LINE COLUMN LINE �--^ -� LIM PROJECT LIMIT LINE ^m �_ EXISTING TO REMAIN — T TO BE DEMOLISHED XXXXX ROOM NAME XXXXX XXXX ROOM NUMBER XXX PROGRAM AREA XXX ACTUAL AREA DOOR REFERENCE WINDOW REFERENCE ❑1 NOTE REFERENCE 1 S2 PARTITION TYPE REFERENCE AREVISION REFERENCE TOP OF PARAPET ELEVATION REFERENCE EL =233' -2" A COLUMN NUMBER OR LETTER (EXISTING CONST.) XXX EQUIPMENT REFERENCE LIFE SAFETY SYMBOLS A4 FIRE /SMOKE COMPARTMENT L CLEAR WIDTH OF DOOR IN INCHES 4" 146 EXIT CAPACITY (VERTICAL) AIR CONDITIONING CLEAR WIDTH OF DOOR IN INCHES T2" 360 d EXIT CAPACITY (HORIZONTAL) 2 -F 2 HR FIRE WALL - 1 -FS 1 HR FIRE /SMOKE WALL 8 CEILING MOUNTED EXIT LIGHT (ARROW INDICATES DIRECTION OF EXIT) ABOVE FINISH FLOOR WALL MOUNTED EXIT LIGHT (ARROW INDICATES DIRECTION OF EXIT) FIRE EXTINGUISHER (WALL MOUNTED) Q FIRE HOSE CABINET W /INT FIRE EXTINGUISHER MAT FIRE ALARM HORN /STROBE FIRE ALARM STROBE ARCHITECTURAL A0.0 COVER SHEET A1.0 INDEX OF DRAWINGS, GENERAL NOTES k SYMBOLS, CODE COMPLIANCE & ABBREVIATIONS A2.0 SITE PUN A2.1 EXISTING FLOOR PUN / LIFE SAFETY PLAN - 1ST FLOOR A2.2 EXISTING FLOOR PUN / LIFE SAFETY PLAN - 2ND FLOOR A2.3 EXISTING FLOOR PUN/ LIFE SAFETY PUN - 3RD FLOOR A2.4 FLOOR PUN / LIFE SAFETY PUN - 2ND FLOOR A2.5 FLOOR PLAN / LIFE SAFETY PLAN - 3RD FLOOR A3.0 OVERALL DEMOLITION PLAN 2ND AND 3RD FLOORS A3.1 OVERALL FLOOR PUN 2ND AND & FLOORS A3.2 OVERALL R.C.P. 2ND k 3RD FLOORS A4.0 PHASE 1 DEMOLITION PLAN 2ND k 3RD FLOORS A4.1 PHASE 1 FLOOR PUN 2ND & 3RD FLOORS A4.2 PHASE 1 R.C.P. 2ND & 3RD FLOORS A4.3 PHASE 2 DEMOLITION PLAN 2ND k 3RD FLOORS A4.4 PHASE 2 FLOOR PUN 2ND & 3RD FLOORS A4.5 PHASE 2 R.C.P. 2ND k 3RD FLOORS A4.6 PHASE 3 DEMOLITION PLAN 2ND k 3RD FLOORS A4.7 PHASE 3 FLOOR PLAN 2ND k 3RD FLOORS A4.8 PHASE 3 R.C.P. 2ND k 3RD FLOORS A4.9 PHASE 4 DEMOLITION PLAN 2ND ik 3RD FLOORS A4.10 PHASE 4 FLOOR PLAN 2ND k 3RD FLOORS A4.11 PHASE 4 R.C.P. 2ND & 3RD FLOORS A4.12 PHASE 5 DEMOLITION PLAN 2ND k 3RD FLOORS A4.13 PHASE 5 FLOOR PUN 2ND k 3RD FLOORS A4.14 PHASE 5 R.C.P. 2ND & 3RD FLOORS A5.0 DOOR SCHEDULE, DOOR TYPES AND NOTES A6.0 ENLARGED FLOOR PUN AND INTERIOR GENERAL ELEVATIONS A8.0 MILWORK A9,0 DETAILS MECHANICAL M -1 MECHANICAL PUN PHASE 1 AND DETAILS M -2 MECHANICAL PUN PHASE 2 AND DETAILS M -3 MECHANICAL PUN PHASE 3 AND DETAILS M -4 MECHANICAL PLAN PHASE 4 AND DETAILS M -5 MECHANICAL PLAN PHASE 5 AND DETAILS M -6 MECHANICAL PLAN FINAL AND DETAILS M -7 SPECIFICATIONS ELECTRICAL E -1 PHASE 1 POWER PLAN 2ND & 3RD FLOORS E -2 PHASE 1 LIGHTING PUN 2ND k 3RD FLOORS E -3 PHASE 2 POWER PLAN 2ND & 3RD FLOORS E -4 PHASE 2 LIGHTING PLAN 2ND & 3RD FLOORS E -5 PHASE 3 POWER PLAN 2ND & 3RD FLOORS E -6 PHASE 3 LIGHTING PUN 2ND & 3RD FLOORS E -7 PHASE 4 POWER PUN 2ND k 3RD FLOORS E -B PHASE 4 LIGHTING PLAN 2ND & 3RD FLOORS E--9 PHASE 5 POWER PUN 2ND k 3RD FLOORS E -10 PHASE 5 LIGHTING PLAN 2ND & 3RD FLOORS AND FIRE ALARM RISER E -11 ELECTRICAL RISER AND LEGEND E -12 PANEL SCHEDULE FIRE SAFETY FS -1 SPRINKLER PUN PHASE 1 FS -2 SPRINKLER PUN PHASE 2 FS -3 SPRINKLER PLAN PHASE 3 FS -4 SPRINKLER PUN PHASE 4 FS -5 SPRINKLER PUN PHASE 5 PLUMBING P -1 PLUMBING PLAN PHASE 1 AND DETAILS P -2 PLUMBING PLAN PHASE 2 AND DETAILS P--3 PLUMBING PLAN FINAL, NOTES AND DETAILS STANDARD ABBREVIATIONS A L LARKIN HOSPITAL- • A/C AIR CONDITIONING U ,INT-ERIQR,RMOVATION ACT ACOUSTICAL CEILING TILE LTG LIGHTING AFF ABOVE FINISH FLOOR M AVG AVERAGE MAT MATERIAL B MAX MAXIMUM EST. BLDG BUILDING MET METAL C MIN MINIMUM Associate Architect N CL CENTER LINE CLG CEILING NO NUMBER Client Codelrile Number CONC CONCRETE NIC NOT IN CONTRACT CPT CARPET N NEW Drawing Issue CT CERAMIC TILE O REVISIONS D BUILDING DEPARTMENT COMMENTS OC ON CENTER DET DETAIL P DN DOWN PSF POUNDS PER SQUARE FOOT DR DOOR PWD PLYWOOD E PT PAINT E}i T'G EXISTING R EC EXPOSED CONCRETE R RELOCATED F S FEC FIRE EXTINGUISHER CABINET SC SOLID �.�viH CtitiA ' *j l ti a ., � „ • �+ Cry April 2nd; 2008 J.L. Beattie ICORE 11',0ING U T' REGISTERED ARCHITECT AR 0010920 FIN FINISH SCH SCHEDUL FL FLOOR SIM s G110t SIMILAR,�7[- �lIGTU'�A�' �� SYMBOLS, CODE FT FEET SQ SQUARE Sheet G ST STONE ppvLO 5Y: A1,00 GWB GYPSUM WALLBOARD STD STANDARD ✓ / V, y ,a GYP GYPSUM V H VB VINYL BASE VCT VINYL COMPOSITION TILE HC HOLLOW CORE V.I.F. VERIFY IN FIELD HM HOLLOW METAL W I W/ WITH IN INC WD WOOD INT INTERIOR WIO WITHOUT LARKIN HOSPITAL- • • • :. � A • A A A �•• ,INT-ERIQR,RMOVATION 7031 S.W*,62nd AVE. • • • • nSOOTH MWAI, C' ORIDA 33143 • owner General Contractor LM A DALY N ERIC) $LNG E EST. 3390 Mary Street, Suite 216 Miami Florida 33133 USA T: 305.461.9480 F: 305.461.3686 Architect Associate Architect 23/100181 _ Client Codelrile Number _113 Frojeci ID- Submission Number 061 -10026 -000 Architects Project Number Drawing Issue REVISIONS NO.1 BUILDING DEPARTMENT COMMENTS 10115/2010 LEO A DALY COMPANY Copyright 2007 *j l ti a ., � „ • �+ Cry April 2nd; 2008 J.L. Beattie REGISTERED ARCHITECT AR 0010920 Scal INDEX OF DRAWINGS, GENERAL NOTES & SYMBOLS, CODE COMPLIANCE & ABREVIATIONS Sheet Title A1,00 Sheet Number