Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
10-1042-020
i® GENERAL ELECTRICAL NOTES 1— ALL ELECTRICAL WORK PERFORMED IN THIS CONTRACT SHALL COMPLY WITH THE NEC, SSBC, LOCAL LAWS AND ORDINANCES, THE RULES AND REGULATIONS OF THE LOCAL UTILITY COMPANIES, AND ALL STANDARDS OF CONSTRUCTION ESTABLISHED BY THE LANDLORD. 2— EXCEPT AS OTHERWISE INDICATED, ALL CONDUCTORS SHALL BE COPPER, USE TW SOLID WIRES FOR CONDUCTORS SIZES No. 10 SMALLER. USE TYPE THW STRANDED CABLE FOR CONDUCTORS IN SIZES No 8 AND LARGER. CABLE SIZES # 4/0 AND LARGER SHALL TERMINATE WITH PRESSURE CRIMP CONNECTORS. ALL CIRCUITS WHICH DO NOT SHOW WIRING AND CONDUIT SIZE ARE TO BE # 12 CU. IN 1/2" CONDUIT. 3— ROUTING OF RACEWAYS. INTERCONNECTING OUTLETS AND HOME —RUNS IS UP TO ELECTRICAL CONTRACTOR, BUT AFTER COMPLETION OF THE INSTALLATION, HE SHALL SUBMIT TO THE ENGINEER AS BUILT DRAWINGS OF HIS WORK FOR FUTURE RECORD. ALL CONDUCTORS SHALL BE IN CONDUIT. FOR UNDERGROUND /IN —SLAB LOCATIONS USE GALVANIZED RIGID STEEL (GRS) CONDUIT OR SCHEDULE 40 PVC CONDUIT WITH GROUND WIRE SIZED AS INDICATED OR REQUIRED BY NEC. UNDERGROUND GRS SHALL BE COATED WITH TWO COATS OF BITUMASTIC # 50 APPLIED WITHOUT THINING. ALL SECTIONS OF METALLIC CONDUIT SYSTEM SHALL BE GROUNDED AND ELECTRICALLY CONTINOUS. USE ELECTRICAL. METALLIC TUBING (EMT) FOR INTERIOR CONCEALED WIRING AND ELSEWHERE AS PERMITED BY THE NEC. USE FLEXIBLE METAL CONDUIT FOR CONNECTIONS TO LIGHT FIXTURES AND TRANSFORMERS. USE LIQUID TIGHT FOR FLEXIBLE CONNECTIONS IN ALL WET LOCATIONS. INSTALL A NYLON PULL CHORD IN ALL EMPTY RACE WAYS FOR FUTURE USE. SIZE ALL GUTTERS AND PULL BOXES PER NEC 370 AND 374. 4— FUSES SERVING ELECTRICAL MOTORS SHALL BE TIME DELAYED TYPE. UNLESS OTHERWISE INDICATED. ALL MOTERS STARTERS ARE TO BE SUPPLIED AND INSTALLED. GENERAL CONTRACTOR IS REQUIRED TO COORDINATE WITH ELECTRICAL AND MECHANICAL SUBCONTRACTORS PRIOR TO BID. 5— ALL WIRING DEVICES SHALL BE SPECIFICATION GRADE HUBBELL OR APPROVED EQUAL WIRING DEVICE PLATES IN FINISHED AREAS SHALL BE PHENOLIC COMPOUND WITH POLISH FINISH. COLOR AND STYLE SELECTED BY ARCHITECT, TENANT, OR OWNER, AS APPLICABLE. ALL SWITHCHES MOUNTED VERTICALLLY 048' A.F.F. UNLESS OTHERWISE SPECIFIED. ALL RECEPTACLES MOUNTED VERTICALLY 018 A.F.F. UNLESS OTHERWISE SPECIFIED. WHERE APPLICABLE, OUTLETS (POWER. TELEPHONE. DATA, SECURITY, ETC.) WITHIN CASEWORK ARE TO BE COORDINATED WITH CASEWORK MANUFACTURER. IN THE CASE OF OUTLETS SERVING CASEWORK MOUNTED EQUIPMENT. COORDINATE WITH CASEWORK MANUFACTURER AND EQUIPMENT MANUFACTURER FOR EXACT REQUIREMENTS PRIOR TO BID, COORDINATE INSTALLATION OF FLOOR OUTLETS WITH OWNER OR TENANT FOR EXACT LOCATION. IF FLOOR OUTLETS SERVE DISPLAY FIXTURES COORDINATE WITH MANUFACTURER FOR EXACT LOCA71ON REQUIRED. LOCATIONS ON THESE DRAWINGS ARE APPROXIMATE. 6— PROVIDE WRITTEN GUARANTEE STATING THAT THE CONDUCTOR WILL REPLACE OR REPAIR, FREE OF CHARGE, ANY EQUIPMENT OR MATERIAL WHICH FAILS DURING A ONE YEAR PERIOD FROM THE DATE OF SUBSTANTIAL COMPLETION. 7— THE ELECTRICAL CONTRACTOR SHALL BE RESPNSIBLE TO COORDINATE HIS WORK WITH THAT OF OTHER TRADES ANDA GENERAL CONTRACTOR. THE ELECTRICAL CONTRACTOR SHALL FURNISH ND INSTALL ALL ITEMS WHICH ARE NECESSARY TO COMPLETE THE INgLLATION OF A COMPLETE AND WORKING ELECTRICAL SYSTEM DICATED BY CONTRACT DRAWINGS. ELECTRICAL CONTRACTOR SHALL SURE A COMPLETE SET OF DRAWINGS PRIOR TO BID TO DETERMINE OTHER WORK INDICATED IN STRUCTURAL. ARCHITECTURAL, MECHANICAL, ,R OTHER DISCIPLINE, WILL AFFECT HIS BID. CONTRACTC 1S TO THE VISIT SITE AND FAMILIARIZE HIMSELF WITH THE EX154G CONDITIONS PRIOR TO BID. , NOTIFY ARCHITECT OF ANY DI:REPANCIES BETWEEN THESE DRAWINGS AND THE EXISTING INSTALLAIN. 8— IN EXISTING BUILDINGS, ALL ROOF AND SLAB INETRATIONS MUST CONFORM TO LANDLORD'S STANDARD CRTIERIAND SHALL BE SUBJECT TO LANDLORD'S APPROVAL AS TO LOCATION AI CONSTRUCTION DETAILS. ROOFING AND /OR WEATHERPROOFINCOF ANY INSTALLATION AND /OR PENETRATION MUST BE PERFORMED E A ROOFING CONTRACTOR AUTHORIZED BY THE LANDLORD. CONTRACTORS REQUIRED TO MAINTAIN FIRE RATING OF ALL WALL AND SLAEPENETRATIONS. 9— ELECTRICAL CONTRACTOR IS TO COORDINATE H WORK WITH THE ARCHITECT, TENANT, OR OWNER, AS APPLICABL, BEFORE ROUGH INSTALLATION OF LIGHTS, RECEPTACLES, AND STTCHES FOR EXACT LOCATION AND HEIGHT. CONTRACTOR SHALL VRIFY THE CEILING FINISHES AND SUSPENSION SYSTEMS FOR SELETION OF THE PROPER TRIM AND SUPPORT ARRANGMENTS OF THE FDURE. COORDINATE REQUIREMENTS PRIOR TO BID. 10— ELECTRICAL CONTRACTOR SHALL COORDINATE TE REQUIREMENTS OF PLUG AND CHORD TYPE EQUIPMENT WITH MANGCTURER AND IS REQUIRED TO PROVIDE ELECTRICAL OUTLETS THT WILL ACCEPT MANUFACTURER'S SUPPLIED PLUGS. 11— ALL AREAS IN WHICH WORK IS BEING PERFOR0 SHALL BE KEPT CLEAN AT ALL TIMES. 12— EQUIPMENT SPECIFIED SHALL BE ADHERED TO. HOWEVER, OWNER HAS THE FINAL. DECISION ON THE TYPE AND QUALW OF EQUIPMENT TO BE SUPPLIED. CONTRACTOR SHALL OBTAIN WRITTEI PERMISSION FROM THE OWNER PRIOR TO PURCHASING SUBSTITUTI6 EQUIPMENT. CONTRACTOR SHALL BEAR THE COST OF ALL EGINEERING WORK RELATED TO SUBSTITUTED EQUIPMENT. 13— PROVIDE REQUIRED CONDUIT WITH PULL— STRING FOR TELEPHONE AS INDICATED. OBTAIN REQUIREMENTS FROM TELERONE COMPANY, TENANT, OR OWNER, AS APPLICABLE , FOR THE INSTALU10N OF TELEPHONE OUTLETS SHOWN ON THESE DRAWINGS. CONTUCTOR SHALL SUPPLY AND INSTALL RACEWAYS TO TELEPHONE COMPANY PCYT OF SERVICE CONTRACTOR SHALL SUPPLY AND INSTALL RACEAYS AND JUNCTION BOXES FROM TELEPHONE BACKBOARD TO ALL LOCATIONS INDICATED, ON DRAWINGS. PRIOR TO BID, CONTACT OWNER OR TENANT TCDETERMINE IF TELEPHONE WIRING AND OR FINISHED PLATES ARE TO BE ICLUDED IN CONTRACT PRICE. LIGHTING FIXTURE SCHEDULE ELECTRICAL LEGEND SWITCHES & RECEPTACLES MOUNflNQ LIGHTS & FIXTURES VOLT SIGNALING SYSTEM CATALOOUE NO. SWITCH A FLUOR. Recessed PUSH BOTTON 4 - M 3326— FSA12.1 RECESSED DOWNLIGHT a BELL ® TIME SWITCH 120 V. WALL LIGHT ST824- 332G— FSA12.12 3EPU— B50—JL TELEPHONE 8" SINGLE RECEPTACLE Recessed FLOURESCENT STRIP 120 V. DATA COVER sM4- 332G— FSJA72.1 3EPU— B50—JL DUPLEX RECEPTACLE ® FLUOR. suspended INTERCOM 4�__ M&WRACLE CP4194- 6'TF'28- 2CFS22 POLE MOUNT LIGHT ® STROBE LIGHT SURFACE 240 V. OUTLET $° FLOODLIGHT © PULL STATION QUAD. RECEPT. EXIT LIGHT 24 HORN / STROBE ® 120V RECEPTACLE EXHAUST FAN +° FIRE ALARM HORN F@ JUNCTION BOX CEILING FAN ® TELEVISION OUTLET ® TEST KEY STATATION GARAGE DOOR MOTOR (D THERMOSTAT EJ' CIRCUIT BREAKER DISPOSAL 0ZH SECURITY CAMERA ® ELECTRICAL METER E C DOOR El Q- O R&RMCAL SPEAKER FOR MUSIC ❑c s ( LT SMOKE DETECTOR ® UM VULIAUL FLOOR DUPLEX RECEPT. DUCT SMOKE DETECTOR - _ __ TO SAFETY SWITCH -- box fuse size size 0 BE WF WEATHER -PROOF LIGHTING FIXTURE SCHEDULE SYMBOL TYPE MOUNflNQ LAMP VOLT MANUFACTURER CATALOOUE NO. REMAMM A FLUOR. Recessed (3)F032 —Te 120 V. COLUMBIA M 3326— FSA12.1 — A1 FLUOR. Recessed (3)FO32 -78 120 V. COLUMBIA ST824- 332G— FSA12.12 3EPU— B50—JL — BOOINE EMERG. BATTERY PACK B FLUOR. Recessed (3)FO32 —TB 120 V. COLUMBIA sM4- 332G— FSJA72.1 3EPU— B50—JL BOOINE EMERG. BATTERY PACK C FLUOR. suspended (8) TF26 120 V. OLYMPIA CP4194- 6'TF'28- 2CFS22 BA E LED SURFACE — 120 V. DUALRE CSXWREB3 —JL exiatIna Vx4'x3/4' PLYWOOD BOARD PAINTED BLACK WITH NON - COMBUSTIBLE PAINT 3/4" C WITH PULL WIRE TERMINATE 6" ABOVE C% D DATA AND TEL OUTLETS. FINISHED PLATES T AND WIRING BY DATA/TEL, SUBCONTRACTOR. Tel. & data subs. to coordinate all requirement with tenant's rep. NTS 45CLI -C-sp, WIRE Q MAIN BUS 200 SERVICE : 0,- • �. . — POLES 42 now �� Elm - s01EMM Elm - . nn■�■■ s�■■■■■■■�� ©ice - __ ■■■■■�■■� s ■■■■ ■■■■ mom - _ __ ■■■■■■��� sue■■■ ■■■■ - - - - i mim - ■■■■■■�■■� sue■■■ ■■■■ - - - - ME -- - - - ■■■■■�■■a s E311121111011 - MIE vvvvE111 FEMAMER U. o KvA 100%: TOTAL 31 KVA 96 A a � y replace `existing panel '-for a' new one with more circuit . PANEL capacity. ,A, .. . q " pt 3rd �.� i \ \ ° ° x i FLOOR I existing exisitng feeders to I 4 #3/0 THW CU existing floor panels I 1 # 6 CU GR. IN 2.5 "C no work to be done I to remain as is I I T� r EXISTING I I I I 1 SEXIST. }r — —, _ _ I existing (I existing I —1 _ —I— _ —!— _ I I i c/t ii existing I f 1 r 1 I PANEL I I PAac t I r -1 n r 1 n r 1 n I I I I (fused III I existing I I II I I existing I Iexisting I (existing I I I disconnecij -LI I I PANEL I w /mcb II w /mcb I I fused III Ifused III Ifused I I I METER L disconnec I disconnec I disconnec L - - -- J —i I 3j* F-�I -� I I I I I P j 1 F�-� 1 3 !-� i, I I I II I i ! LM 1 of 1 J I I ,_r L_� L____r_J�_ —� —_� L_ _1_J L_ _r_J L_-r J w L . a I I --- - - - - -- -•� EXISTING 10 "X10" L_ �w. _.. I � i --- - - - - -- —� WIREWAY � ° iI L------------------------ -.$.— •._r.,.___.____..j • � _ iZ� � «tee.-. ! ; EXISTING TO REMAIN. 3/4" CW PIPE total load has not s changed _ EXISTING #2/0 CU -GR WIRE TO 5/8" RD. REBAR IN FOUNDATION. ELECTRICAL RISER NTS k f I 1 I ° atn i «� �rt•a..r ..fi=x "�:J'!!� �A\Pv\C E N s !.4 i at Plo. 34923 � z X• T FGTAVO got. Ca t 4Fchanical / 9. ' \ ' ��&risultirig # o-q . � A a. registrat 7410 —B sm. 48th. ST., r t e 1 ( 3 0 5) 6 1 Y4 *n