Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
10-101-005
3 -D 17 D0 C' E O3 -DIG MECHANICAL ROOM I l\lj . CONTROL COMPUTER EOL -BPSA AC2 RADIOGRAPHY I X -RAY QER ROOM ROOM 4 -27 No I 1575CD 4 -29 1575CD I BATH STAIR BATH QN I3 -M F5 4 -26 I 3 -M5 T5 E O 1575Ci � 3 -M3 3 -D 15 I IE .} -2G 1575CD I I CONTROL ROOM SCRUB IEQUIP, Qo 4 -25 IROOM E 1575CD L) I GLA55 I ANGYOGRAPHY I PROCEDURE ROOM I I m i OI 2�D 14 ' ©° E 4 -24 75CD I I X -RAY RM, I WAITING ROOM 423 7/icD 0575 IQ� PFa�'- __Tf��_ ARE A LAR�' F_C� ❑'' PL��N RD F=- __.EDR sco -_E CHI ALARMS, INC, /0' 1/ 0„ FIRE ALARM NOTES 1— EXISTING FACP NOTIFIER NFS -320 ADDRESSABLE W/ 159 SENSOR AND 159 MODULE CAPACITY. LOCATED AT TELEPHONE ROOM ON 1ST FLOOR WITH CAPACITY 6.OAMP. 2 —FIRE ALARM SYSTEM SHALL BE POWER LIMITED. 3 —ALL ALARM DEVICES SHALL BE UL LISTED FOR FIRE. 4 —ALL WIRING MUST CONFORM WITH NEC. 760 AND LOCAL CODES. 5 —ALL DEVICES SHALL BE COMPATIBLE WITH FIRE ALARM CONTROL PANEL. 6 —BUILD OUT SPACE BY INTERIOR RENOVATION AT EXISTING BUILDING AT 1RS AND 2ND FLOOR. BUILDING FULLY FIRE SPRINKLERED. 7— DEDICATED 120VAC BRANCH CIRCUIT WITH LOCK FOR FACP AND BOOSTER POWER SUPPLIES. BREAKER @20 AMP IN ELECTRICAL PANEL. 8 —EMT CONDUIT SHALL BE 1/2" MINIMUM. 9— PERCENTAGE FILL AT 40 % MAXIMUM. 10— CONDUIT UP TO 8 FEET AND FREE WIRING. 11 —CABLE 18/16 AWG FPL OR EQUAL ©300V MIN & 12 AWG THHN OR ROMEX @ 600V MIN, 12 —ALARM IS GENERAL TEMPORAL TONE ON ALL INITIATING DEVICES. 13— SYSTEM INITIATING CIRCUIT SHALL BE CLASS "B" STYLE 4. 14 —ALL CONTROL RELAY SHALL BE WITHIN 3 FEET OF DEVICES BEING CONTROLLED. 15— SYSTEM SIGNAL SHALL BE CLASS "B" STYLE Y. 16— VISUAL ALARM TO COMPLY W/ ANSI A117.1,4.26 AND NFPA 72 AND F.B.C. 2001 ED. 17 —WALL MOUNTED VISUAL DEVICES ® 80" TO 96 "AFF BOTTOM OF LENS OR 6" FROM CEILING WHICHEVER IS LOWER & CEILING MOUNT. 18 —NEW STROBES 15/75CD MINIMUM TO COMPLY WITH FLORIDA ACCESSIBILITY CODE. 20 —ALL NEW STROBES ARE 15/75CD MINIMUM. 21— CEILINGS ARE FLAT AND 10 FEET HIGH OR LESS. 22— CEILING MOUNTED SMOKE DETECTORS SHALL NOT BE LOCATED IN A DIRECT AIRFLOW, NOR CLOSER THAN 3 FEET FROM AN AIR SUPPLY DIFFUSER. NFPA 72 A -5 -3.6.1 AND A- 5- 5.7.1. 23 —THERE IS NO EM CONTROL ON THIS SYSTEM. 24— MANUAL INITIATING DEVICES MOUNT @ 42" TO 54 "AFF. 25 —THIS IS AN EXISTING CERTIFIED /PLACARDED CENTRAL STATION FIRE ALARM SYSTEM. REPORTING BY TWO TELEPHONE LINES. 26— NOTIFICATION APPLIANCES WILL BE INSTALLED AS PER NFPA - 72.7.4.3 PRIVATE MODE AUDIBLE REQUIREMENT 27— BATTERY CALCULATION © 24HR STANDBY AND 5 MINUTE IN ALARM. 28 —ALL REMOTE PANEL ARE PROTECTED WITH SMOKE DETECTOR. 29 —VALUE OF WORK UNDER $5,000.00. 30 —THE DESIGN INSTALLATION COMPLIES WITH (FBC11- 4.28.3) 31— EXISTING FIRE ALARM ANNUNCIATOR LCD -80 LOCATED BY MAIN ENTRANCE. SEQUENCE OF OPERATION SEQUENCE OF OPERATION REMAIN THE SAME. ACTIVATION OF ANY SMOKE DETECTOR, MANUAL STATION, HEAT DETECTOR AND SPRINKLER WATER FLOW SHALL CAUSE THE FOLLOWING ACTIONS AND INDICATIONS: INDICATE AT THE FIRE ALARM CONTROL PANEL VIA THE LCD ALPHANUMERIC DISPLAY, A CUSTOM MESSAGE DESCRIBING THE DEVICES ORIGINATING THE ALARM CONDITION, SOUND THE AUDIBLE SIGNALS AND ILLUMINATE THE VISUAL SIGNALS THROUGHOUT THE FACILITY, SHUT DOWN ALL THE AIR HANDLING UNITS WITHIN THE BUILDING, IF THE ALARM DETECTOR IS IN THE ELEVATOR LOBBY AND MACHINE ROOM, RECALL ELEVATORS TO EITHER THE PRIMARY OR SECONDARY FLOOR DEPENDING ON THE FLOOR IN ALARM AND LIGHT THE ELEVATOR WARNING LIGHTS, ACTIVATION OF THE HEAT DETECTOR LOCATED IN THE ELEVATOR MACHINE ROOM SHALL AUTOMATICALLY SHUNT POWER THE ELEVATOR, AND INDICATE AT THE FIRE ALARM CONTROL PANEL AND SOUND THE AUDIBLE AND ILLUMINATE THE VISUAL THROUGHOUT THE FACILITY, REPORT AN ALARM SIGNAL TO THE CERTIFIED /PLACARDED CENTRAL STATION SERVICE FIRE ALARM SYSTEM VIA TWO TELEPHONE LINES. ACTIVATION OF ANY TAMPER SWITCH OR BACKFLOW SWITCH SHALL CAUSE THE FOLLOWING ACTIONS AND INDICATIONS: ACTIVATE A SUPERVISORY ALARM AT THE MAIN CONTROL PANEL, DISPLAY A MESSAGE AT THE MAIN CONTROL PANEL, LCD DISPLAY, REPORT TO THE CERTIFIED /PLACARDED CENTRAL STATION SERVICE FIRE ALARM SYSTEM VIA TWO TELEPHONE LINES. ACTIVATION OF THE DUCT DETECTORS SHALL CAUSE THE FOLLOWING ACTIONS AND INDICATIONS: SOUND A LOCAL BUZZER AT THE MAIN CONTROL PANEL,. DISPLAY A SUPERVISORY ALARM MESSAGE AT THE MAIN CONTROL PANEL, SHUT DOWN ALL AIR HANDLING UNITS WITHIN THE BUILDING. REPORT TO THE CERTIFIED /PLACARDED CENTRAL STATION SERVICE FIRE ALARM SYSTEM VIA TWO TELEPHONE LINES. ACTIVATION OF THE TROUBLE SIGNAL SHALL CAUSE THE FOLLOWING ACTIONS AND INDICATIONS: SHALL SOUND A LOCAL BUZZER AT THE MAIN CONTROL PANEL. DISPLAY A MESSAGE AT THE MAIN CONTROL PANEL LCD DISPLAY, REPORT TO THE CERTIFIED /PLACARDED CENTRAL STATION SERVICE FIRE ALARM SYSTEM VIA TWO TELEPHONE LINES. AREA ANGYOGRAPHY PROCEDURE I ROOM i I FA' mp r THIRD FLOOR. KEY PLAN. SCALE 1/8"= 1' O" EXISTING BOOSTER POWER SUPPLY - -1 :l u 12/28 09 DRAWN BY: lq- z Off = 1' CHI ALARMS, INC, �t w z ■. W Q rZ w m In O CL < u- (.0 ,-) Q z `u O O Q N V) Z O C G w z CY_ O Q u 12/28 09 DRAWN BY: lq- z Off = 1' CHI ALARMS, INC, �t w O ■. W Q rZ w m In O CL < u- (.0 ,-) Q z `u O O Q N V) Z O C G w z CY_ O Q C"-4 12/28 09 DRAWN BY: C.N. SCALE: Off = 1' CHI ALARMS, INC, F-2 SHEET 2 OF 3 w O (or) LL. Q w CL < (.0 ,-) O Q V) Z Li CY_ Q oATE : 12/28 09 DRAWN BY: C.N. SCALE: Off = 1' CHI ALARMS, INC, F-2 SHEET 2 OF 3