Loading...
12-250-034AIR CONDITIONING NOTES- 1,- ALL CONDITIONING SUPPLY DUCTSAND FRESH AIR INTAKE DUCTS SHALL HAVE A MANUAL VOLUME BALANCING DAMPER INSTALLED. 2.- ALL WORK SHALL BE IN ACCORDANCE WITH THE LATEST LOCAL CODES, FLORIDA BUILDING CODE AND SECTION 503 OF FLORIDA ENERGY EFICIENCY CODE, 3,- DUCTWORK: RETURN AND SUPPLY PLEUMS TO BE ( +) 1 1/2' FIBERGLASS DUCTBOARD ALL SEAMS AND JOINTS SEALED AND STAPLED WITH SILVER TAPE UL181A.T❑ BE R -6 FLEX DUCT USING SILVER TAPE UL181A AND NYLON PANDUIT STRAPS AT COLLAR CONNECTIONS. ROUND DUCT WORK 4,- AIR CONDITIONING CONTRACTOR SHALL PROVIDE ONE YEAR GUARANTEE ON ALL MATERIAL AND LABOR FURNISHED AND FIVE YEARS ON ALL COMPRESSORS, 5,- ALL FLEX DUCT TO BE HUNG WITH 2' U CHANNEL CONTINUOUS PROVIDE AIR CHAMBERS ON ALL SUPPLIES, 6.- FANS TO BE CONNECTED FOR PROPER SHUT DOWN, 7.- RETURN AIR GRILLES ARE FILTERED. 8,- RECTANGULAR DUCTWORK TO BE HUNG WITH 2' U CHANNEL AND METAL STRAP @ 4' O.C. 9,- ELECTRICAL CONTROLS AND POWER WIRING UNDER ELECTRICAL CONTRACT, 10.-TEST AND BALANCE° C❑NRACTOR SHALL TEST AND BALANCE VENTILATION AND A/C SYSTEMS, DUCT CALCULATIONS SYSTEM 1 EQUAL FRICTI ❑N DUCT SIZING= (0.1 IWG /LENGHT) X 100 L -1 EFDS= (0.1 IWG/ 24') X 100 = 0.416 IWG 3 3�" EQUAL FRICTION DUCT SIZING= (0,1 IWG /LENGHT) X 100 L -2 EFDS= (0.1 IWG/ 30') X 100 = 0.33 IWG O DUCT CALCULATI ❑NS SYSTEM 2 FRESH AIR INTAKE �1 EQUAL FRICTION DUCT SIZING= (0.1 IWG /LENGHT) X 100 L -1 EFDS= (0.1 IWG/ 19.5`) X 100 = 0.5128 IWG 108 EQUAL FRICTION DUCT SIZING= (0,1 IWG /LENGHT) X 100 L -2 EFDS= (0.1 IWG/ 30') X 100 = 0.33 IWG 120/1 CONDENSER REFRIGERANT PIPING TO RESPECTIVE AHU 4' CONC. SLAB 3/4' VIBRA PADS / UNIT TO BE SECURE TO CONC. PAD USING 5/16' TAPCON & STRAP TYP OF 4 CONDENSER ATT. DETAIL SCALE: NTS REFRIGERANT PIPING + CONTROL WIRING FMC1101 TO CONSDENSING UNIT RETURN DUCT FMC 601 CMU WALL CREAREANCESo SIDES, 12' SERV. PANELi 36' TOP, 60' 4' PVC PIPE SLEEVE WATERTIGHT ' THREADED ROD SUSPENDED FROM TOP CHORD SUPPLY AIR DUCT FMC 601 AUX. DRAIN PAN +FLOAT SWITCH CONDENATE FLOAT SWITCH ASSY. WIRED FMC 301.2.3 DRAIN FMC 307 TO SHUT OFF AHU AND CU HORIZONTAL AIR HANDLER DETAIL SCALE: NTS HVAC LEGEND SYMBOL DESIGNATION CBS INS. INT. R -4.0. MANUAL VOLUME DAMPER �T THERMOSTAT 3 3�" 4 WAY SUPPLY AIR CEILINGS R -19 RETURN AIR GRILL (D EQUIPMENT DESIGNATION �S SMOKE SENSOR / FIRESTAT O EXHAUST FAN 100 CFM 120/1 FRESH AIR INTAKE �1 SUPPLY DUCT Broan RETURN DUCT Ceiling SCOOP IN DAMPER INSULATION TYPES MARK SERVICE CBS INS. INT. R -4.0. %" RIGID POLYSTYRENE FRAME WOOD ADJACENT R -13, 3 3�" BATTS FIBERGLAS CEILINGS R -19 6 Y4" BATTS FIBERGLAS ATTIC R -30 9 J�"" BATTS FIBERGLAS SCREEN NOTE, CONTRACTOR WILL DETERMINE ROOF LOCATION. SELF FLASHING BASE CAP TO BE COATED WITH TAR 3N BOTH SIDES OF THE FLANGE. FLANGE TO LINE FLUSH WITH ROOFTOP AND TO BE SEALED WATERTIGHT WITH TAR, ATTACH DUCT WORK TO CAP AND SEAL • ROOF , • ' I SECURE �1119 TYPICAL HANGING STIR AND SADDLE HANGIN( DETAIL TYPICAL 2 BAR AND WIRE DUCT HANGING DETAIL i I ' ' NEW FAN SCHEDULE MARK SERVICE MFG. Model MTG, CFM ESP In H2O Volt / Phase Watts F 1 Restroom Exhaust Broan OTR110 Ceiling 110 0.10 120/1 108 F 2 Restroom Exhaust Broan QTRI10 Ceiling 110 0.10 120/1 108 F 3 Restroom Exhaust Broan QTR110 Ceiling 110 0.10 120/1 108 NEW SPLIT UNIT SCHEDULE CU -1 & 2 PLAN MARK MFG. LOCATI ❑N MODEL SEER # VOLTAGE OVERCURRENT DEVICE MAX,(2) MIN. CIRCUIT AMPACITY = CU -1 DATA SCFM C❑ ❑LING CAPCITY (BTU) C ❑IL —COMPONENTS FAN MOTOR FAN BLADE C❑MPRESOR CU -1 EXISTING EXISTING EXISTING CAPACITY = CU -2 X 1.15 = 30K )K1,15 = 34,5K BTU W CU -2 RHEEM OUTSIDE GRD, ELEV RAPM036JEZ 15,5 208 -230 1PH -60HZ 35 21 2 -18 3/8' 0 PSC, 0.8 AMP 1/6 HP 24'0- 3 SCFM -4000 16 LRA - 79 3300 1557 36,000 WALLAWABLE RANGE PER FMC; 100 -115% OF DESIGN CAPACITY = CU -1 X 1,15 = XXXXXX 1.15 = XXXK BTU WALLAWABLE RANGE PER FMC; 100 -115% OF DESIGN CAPACITY = CU -2 X 1.15 = 30K )K1,15 = 34,5K BTU NEW AC AHU UNIT -1 & 2 PLAN MFG L ❑CATI ❑N MODEL VOLTAGE MIN. CIRC MAX, BKR, BLOWER COMPONENTS CONNECTORS DATA NOMINAL RATINGS BLOWER SERVICE VALVE COOLING (BTH /H) CFM MARK 6 ---. Cr9 SEER # � AMPACITY SIZE MOTOR AHU -1 W O ^� w ]C CL P4 g P4 5C � O P4 EXISTING EXISTING EXISTING 14 15 tc) Lf) M 0 u v AHU -2 RHEEM ON 208 -230 4.9/9.9 15/15 FLA 2.5 10 5/8'0 LIQUID 3/8' 30,000- 36,000 H -1,200 TRUSSES RHPNHM3624JC HP 3/4 DRAIN FTP 3/4' SUCTION 7/8' 2.5 TO 3 TON M-950 1PH -60HZ L- 600 WALLAWABLE RANGE PER FMC: 100 -115% OF DESIGN CAPACITY z 0 I= I- Cn 0 wI Q { ....................., ..... ................,,............. ..., ........ ........................ . .......... ,................. ,.. EXISTING �N I.C.) s' rf �` i _..... :. ...i ` ............. `..+......,...... _..... _f �' ... _........... ........... ......................... .,..:....,...................,1 ..P E L EXISTING (N..C.) .............................. ............................... ... 2 , ;..,gin 10x6 75 CFM 0181 {: 6"0 12X12 10*0 / 6x12 120 CFI( 16X1 ......................... .......,, +Co ........ `moo 70 CFM 6X4 ............. .. .... ........... Iro 70 CFM \ 1 z 80 k r`r 1 70 CFM RNMOOTF A /. -H .............. ............... f , •, `F2 z I4x12 k \ .. � ON TRUSSES : c ....................... .................. ............. ............ .......: ... .........................,.,.,. ...........................,.,E t{..b�,..._._._ _ ._ ,.«.,.....,. -,.., mss. ..,... ... ....... ............ .. :} w.v },! `./........,..................` c LOUVERED GRILL DSL _ _ _ _ _ __ Fi !ROOF 18'x22! !� m " :• :.... € tR %t 70 CFI( 8X4 6'i r' r{ ..........., 120 ON ' HATCIfED ,:AREA /INDICATES /' f { , /EXISTING , (N.I.0 : : : ::: : : : ::::::::' 7 , µ 70 CFM 6X4 4 .: + ............::.:. A.G. MIN. 10*0 Lo •+•L; \gg D f 12X12 „t...,. e. CU• -2 _ _ z"I g ADDRESS 7011 SW 68 CT. S. MIAMI FLORIDA LEGAL DESCRIPTION LOT 2 OF SUNSET CIRCLE ACCORDING TO THE PLAT BOOK 48 PAGE 5 MIAMI —DADE COUNTY, FLORIDA Piz El�� gig -a 151H111190N PROJ No10 -13-11 Fl(_E:knoopff ws Hemat DRAWN: G.A.R. CHECKED: A.K. DATE: 01 -20 -12 aw 11110 DO NOT SCALE DRAWINGS, USE GIVEN DIMENSION REPORT. ANY DISCREPANCIES ON DIMENSION REPORT TO THE ARCHITECT OR CONSTRUCTION SUPERINTENDENT BEFORE PROCEEDING WITH WORK. THESE PLANS ARE IN COMPLIANCE WITH THE 2007 FLORIDA BUILDING CODE AND 2009 SUPPLEMENT INCLUDING SECTION 1609 FOR 140 MPH BASIC WIND SPEED 3— SECOND GUST AND EXPOSURE "B" WIND ZONE b Ito U b CLZO 2 r -.—i M M c� 0 V1 P4 6 ---. Cr9 fVJw � a r U W O ^� w ]C CL P4 g P4 5C � O P4 m w a to 14 15 tc) Lf) M 0 u v DO NOT SCALE DRAWINGS, USE GIVEN DIMENSION REPORT. ANY DISCREPANCIES ON DIMENSION REPORT TO THE ARCHITECT OR CONSTRUCTION SUPERINTENDENT BEFORE PROCEEDING WITH WORK. THESE PLANS ARE IN COMPLIANCE WITH THE 2007 FLORIDA BUILDING CODE AND 2009 SUPPLEMENT INCLUDING SECTION 1609 FOR 140 MPH BASIC WIND SPEED 3— SECOND GUST AND EXPOSURE "B" WIND ZONE b Ito U b CLZO -.—i c� ---. Cr9 c� Q r DO NOT SCALE DRAWINGS, USE GIVEN DIMENSION REPORT. ANY DISCREPANCIES ON DIMENSION REPORT TO THE ARCHITECT OR CONSTRUCTION SUPERINTENDENT BEFORE PROCEEDING WITH WORK. THESE PLANS ARE IN COMPLIANCE WITH THE 2007 FLORIDA BUILDING CODE AND 2009 SUPPLEMENT INCLUDING SECTION 1609 FOR 140 MPH BASIC WIND SPEED 3— SECOND GUST AND EXPOSURE "B" WIND ZONE b Ito U b CLZO -.—i c� ---. Cr9 c� cry O ^� CL P4 noepffler —VAN HEMERT SHEET M -1 14 15