12-250-0070 I to I 0 1 to 1 pt N I DEMOLITION FLOOR PLAN SEE SHEET A -1 SITE PLAN FOR OVERALL FINAL FLOOR PLAN 1/4" = 1' -0" LEGEND (NOTES)O -- THIS SHEET NOT USED O2 -�► NOT USED NOT USED O4 -�► HATCHED AREA INDICATES EXISTING ROOF PORTION TO BE REMOVE TO RECEIVE NEW GABLE ENTRY ROOF -SEE DRAWINGS a5 -� PORTION OF EXISTING ROOFING ABOVE TO BE REMOVE, SEE ROOF PLAN FOR AREA - EXISTING ROOF TRUSSES TO REMAIN as -�► DASHED LINE INDICATES EXISTING BLOC( WALL TO BE REMOVE, BEAM ABOVE TO REMAIN. SHOWN REMAINING BLOC( SHALL BE REINFORCED WITH 1 -15 VERTICAL REBAR AT EACH CELL AND FILL WITH CONCRETE, REBAR SHALL BE EMBEDDED INTO FOOTING AND BEAM ABOVE 4' MIN., REMOVE AND REINSTALL SHOWN BLOCK COLUMN IF NEEDED. 0­3_ NOT USED 0­3- NOT USED �9 -s NOT USED 10 NOT USED 11 EXISTING GYPSUM WALLBOARD AND WOOD FRAMED WALL TO BE REMOVE, PATCH TO MATCH ADJACENT FINISHES 12 REMOVE EXISTING SHELVING 13 REMOVE EXISTING BI -FOLD DOORS 14 NOT USED 15 NOT USED { 16 NOT USED 17 REMOVE EXISTING WINDOW, SEE NEW FLOOR PLAN FOR NEW WINDOW SIZES 18 REMOVE EXISTING WINDOW, CLOSE OPENING WITH BLOC(, PATCH TO MATCH ADJACENT FINISHES 19 REMOVE EXISTING BLOCK WAIL AS SHOWN FOR NEW HALLWAY, SEE NEW FLOOR PLAN, PATCH TO MATCH ADJACENT FINISHES 20 INSTALL NEW 1 -15 VERTICAL REBAR W11H FILLED CELL, CUT ADDITIONAL 8" OF BLOC( FOR NEW REINFORCED BLOCK CELL 21 REMOVE EXISTING OVERHANG THIS SIDE OF EXISTING RESIDENCE (SEE ADDITION FLOOR PLAN FOR OVERHANG SECTIONS THAT WILL NEED TO BE REMOVE) DASHED LINE INDICATES AREA OF EXISTING POOL PAVERS TO BE REMOVE (FIELD VERIFY) -AREA TO RECEIVE ADDITION 23 EXISTING HVAC COMPRESSOR TO BE RELOCATED (CONTRACTOR SHALL COORDINATE NEW LOCATION WITH SELECTED HVAC CONTRACTOR) 24 EXISTING ELECTRICAL METER TO BE RELOCATED (SEE FLOOR PLAN - ELECTRICAL DWG FOR NEW LOCATION) INDICATES EXISTING WALLS TO BE REMOVE (SEE LEGEND) ADDRESS 7011 SW 68 CT. S. MIAMI FLORIDA LEGAL DESCRIPTION LOT 2 OF SUNSET CIRCLE ACCORDING TO THE PLAT BOOK 48 PAGE 5 MIAMI —DADE COUNTY. FLORIDA DO NOT SCALE DRAWINGS, USE GIVEN DIMENSION REPORT. ANY DISCREPANCIES ON DIMENSION REPORT TO THE ARCHITECT OR CONSTRUCTION SUPERINTENDENT BEFORE PROCEEDING WITH WORK. THESE PLANS ARE IN COMPLIANCE WITH THE 2007 FLORIDA BUILDING CODE AND 2009 SUPPLEMENT INCLUDING SECTION 1609 FOR 140 MPH BASIC WIND SPEED 3— SECOND GUST AND EXPOSURE "B" WIND ZONE u 11 R ;R ingil I A A o PROJ NoIG -13-11 FlLE:knoepfflw —Hemert DRAWN: G.A.R. CHECKED: A.K. DATE. 01 -20 -12 N >— is m ul O H �� V � w M M 0 4 ► a °- � o N r b � Q, 4 ♦p tb � �r{ O '_'`_, w < a � w • z w Q ° W g E"'4 Y � c10 O � W q w _ Ln o° Lf)� tart ass �� O a O V r b � Q, 4 ♦p tb � �r{ oepffler —VAN HEMERT Oe SHEET r A -2 03 1 15 I� O O V b O '_'`_, • z COO O �„7 _ cc� V �♦ oepffler —VAN HEMERT Oe SHEET r A -2 03 1 15