Loading...
12-250-002� Z z F- P= ocn aW Mr. ARCHITECTURAL 1 0.4 19 on 01 A -0 COVER SHEET, INDEX OF DRAWINGS, PROJECT DATA 02 A -1 SITE PLAN 03 A -2 DEMOLITION PLAN 04 A -3 FLOOR PLAN - DIMENSIONED 05 A -4 FLOOR PLAN -NOTED 06 A -5 ROOF PLAN 07 A -6 EXTERIOR ELEVATIONS 08 A -7 CROSS SECTION AND WALL SECTIONS STRUCTURAL 09 S -1 FOUNDATION PLANS 10 S -2 TIE BEAM PLANS 11 S -3 STRUCTURAL NOTES AND DETAILS 12 S -4 STRUCTURAL NOTES AND DETAILS 1,T) mvp F OIF; / 1 g _ N 9A *,W* Van MECHANICAL 13 M -1 MECHANICAL FLOOR PLAN ELECTRICAL 14 E -1 ELECTRICAL FLOOR PLANS ZZ Miami, FLOOD LEGEND ADDITION, REMODELING, REPAIRS AND COMBINATION FOLIO: ADDRESS:7011 SW 68 CT LOT /UNIT: 2 SUNSET SUBDIVISION:CIRCLE PLAT BOOK: 48 PAGE: 5 COST OF CONSTRUCTION: SCOPE OF WORK INTERIOR RENOVATION: COST OF WORK $• (MUST ITEMIZED LIST) ADDITION: COST OF WORK 1251 SQ. FT. CONST. x($47 SQ. FT. LIVING SPACE) $59,079 198 SQ. FT. CONST. x ($35 SQ. FT STORAGE, GARAGE) $ 6,930 TOTAL COST OF WORK $66,009 �� OCCUPANCY: RESIDENTIAL: R1 LOWEST FLOOD ELEV/INCLUD. GARAGE /STORAGE FLOOR ADJACENT, GRADE ELEVATION NEW BASEMENT SUNKEN AREAS. ELEVATION NEXT TO WALL OF STRUCTURE EXISTING 16.78 N.G.V.D. 2,267 S.F. SUBTOTAL 1,449 S.F. 14.65 N.G.V.D. ADDITION 16.78 N.G.V.D. 14.65 N.G.V.D. o ° w le WQ THE OWNER OF THIS PROPERTY UNDERSTANDS THAT THE WORK AMOUNT INDICATES ABOVE IS GOING TO BE KEPT ON THE OMCIAL PERMIT RECORD DURING A SIX (6) MONTH PERIOD FROM THE DATE OT WHICH THE CERTIFICATE OF COMPLETION IS ISSUED, IF ANY ADDITIONAL, REPAIR, RECONSTRUCTION, ALTERATION, ADDITION, REMODELING OR COMBINATION THEREOF IS DONE BEFORE THE CERTIFICATE OF COMPLETION IS ISSUED, OR WITHIN THE TRACKING PERIOD, IT WILL BE CONSIDERED A CONTINUANCE OF THE ABOVE WORK, IF THE PROPERTY IS DECLARED SUBSTANTIALLY WILL BE ELEVATED IN ACCORDANCE WITH CHAPTER 11C OF THE MIAMI -DATE COUNTY CODE. z ZO �z �o X o W Q r e s i d e c I -.&- - �qivvwmlfivi LOT AREA GROSS SQUARE FOOTAGE: 17,303 S.F. EXISTING RESIDENCE SQUARE FOOTAGE: 2,267 S.F. LIVING AREA ADDITION SQUARE FOOTAGE: 1,251 S.F. GARAGE AREA ADDITION SQUARE FOOTAGE: 198 S.F. LOT COVERAGE 21,47% VISUAL SITE INSPECTION REVEALS CLEAN UNDISTURBED SAND AND /OR ROCK OF 2000 PSI MINUMUM BEARING CPACITY, ARCHITECT WILL PROVIDE STATEMENT LETTER TO BUILDING OFFICIAL AFTER GROUND BREAKING ATTESTING TO THE OBSERVED BEARING CAPACITY. GENERAL NOTES: THE CONTRACTOR SHALL EXAMINE THE DRAWINGS CHECK AND VERIFY ALL DIMENSIONS, ELEVATIONS AND OTHER EXISTING CONDITIONS BEFORE COMMENCING WORK. IN CASE OF ANY DISCREPANCY THE ARCHITECT MUST BE NOTIFIED IN WRITING BEFORE PROCEEDING WITH ANY WORK. THE CONTRACTOR IS SOLELY RESPONSIBLE OF CONSTRUCTION MEANS, TECHNIQUES, SEQUENCES, PROCEDURES AND SAAFETY REGULATIONS IN CONNECTION WITH THE WORK. DIMENSIONS TAKE PRECEDENCE OVER SCALE. ALL MANUFACTURERS AND /OR SUPPLIER SHALL SUBMIT SHOP DRAWINGS TO THE ARCHITECT OR ENGINEER FOR APPROVAL PRIOR TO FABRICATION. REQUIREMENTS TO EXISTING RESIDENCE AS SPECIFIED UNDER CHAPTER 34 OF THE FLORIDA BUILDING CODE. 1. PROVIDE IMPACT RESISTANT GLASS AT ALL WINDOW OR PROVIDE APPROVED HURRICANE SHUTTERS. 2. CORNERS OF BUILDING TO HAVE 1 -#5 TIE -DOWN CONCRETE FILLED CELLS AND AT 8' -0" O.C. THEREAFTER. 3. GFI OUTLETS SHALL BE INSTALLED WHERE REQUIRED BY CODE 4. SMOKE DETECTORS SHALL BE INSTALLED MIRE REQUIRED BY CODE. Addition TOTAL EXIST. 2,572 S.F. TOTAL ADD. 1,776 S.F. NEW TOTAL OVERALL 4,348 S.F. ADDRESS 7011 SW 68 CT. S. MIAMI FLORIDA LEGAL DESCRIPTION LOT 2 OF SUNSET CIRCLE ACCORDING TO THE PLAT BOOK 48 PAGE 5 MIAMI -DADE COUNTY, FLORIDA Fit, p Na l6n; Is y.!{ -1 je r -=oa Nv Nigro, - BUILDING AND STRu4vm"kL­ -FLORIDA BUILDING CODE 2007 EDITION WITH 2009 SUPPLEMENT - PLUMBING - n TInA PLUMBING CODE 2007 EDITION - MECHANICAL - FLORIDA M` 'AN(`k CODE 2007 EDITION - ELECTRICAL -NEC 2007 -FIRE PROTECTION: - FLORIDA FIRE PROTECTION CODE EDITION ACCESSIBILITY: - FLORIDA ACCESSIBILITY CODE 2007 EDITION CONSTRUCTION TYPE: "V -B l �� OCCUPANCY: RESIDENTIAL: R1 SQUARE FOOTAGE CALCULATIONS: EXISTING NEW LIVING 1,930 S.F. LIVING 1,251 S.F. GARAGE 337 S.F. GARAGE 198 S.F. SUBTOTAL 2,267 S.F. SUBTOTAL 1,449 S.F. ENTRY 135 S.F. GAZEBO 327 S.F. LANAI 170 S.F. TOTAL EXIST. 2,572 S.F. TOTAL ADD. 1,776 S.F. NEW TOTAL OVERALL 4,348 S.F. ADDRESS 7011 SW 68 CT. S. MIAMI FLORIDA LEGAL DESCRIPTION LOT 2 OF SUNSET CIRCLE ACCORDING TO THE PLAT BOOK 48 PAGE 5 MIAMI -DADE COUNTY, FLORIDA Fit, p Na l6n; Is y.!{ -1 je r -=oa Nv Nigro, ADO NOT SCALE DRAWINGS. USE GIVEN DIMENSION REPORT. ANY DISCREPANCIES ON DIMENSION REPORT TO THE ARCHITECT OR CONSTRUCTION SUPERINTENDENT BEFORE PROCEEDING WITH WORK. THESE PLANS ARE IN COMPLIANCE WITH THE 2007 FLORIDA BUILDING CODE AND 2009 SUPPLEMENT INCLUDING SECTION 1609 FOR 140 MPH BASIC WIND SPEED 3- SECOND GUST AND EXPOSURE "B" WIND ZONE r w W Nq 8 • � � �� * M M � a Z..7 COT Iq a w J a 0 w o ° w le WQ J Y ¢ co O M w m s'n O to v ADO NOT SCALE DRAWINGS. USE GIVEN DIMENSION REPORT. ANY DISCREPANCIES ON DIMENSION REPORT TO THE ARCHITECT OR CONSTRUCTION SUPERINTENDENT BEFORE PROCEEDING WITH WORK. THESE PLANS ARE IN COMPLIANCE WITH THE 2007 FLORIDA BUILDING CODE AND 2009 SUPPLEMENT INCLUDING SECTION 1609 FOR 140 MPH BASIC WIND SPEED 3- SECOND GUST AND EXPOSURE "B" WIND ZONE r W Nq 8 • � � �� * •ham � �r _5 b `rte I w a t b a.� r "%4 -- CL> • .-� v.� �dd :-4 - cd 4. o � ADO NOT SCALE DRAWINGS. USE GIVEN DIMENSION REPORT. ANY DISCREPANCIES ON DIMENSION REPORT TO THE ARCHITECT OR CONSTRUCTION SUPERINTENDENT BEFORE PROCEEDING WITH WORK. THESE PLANS ARE IN COMPLIANCE WITH THE 2007 FLORIDA BUILDING CODE AND 2009 SUPPLEMENT INCLUDING SECTION 1609 FOR 140 MPH BASIC WIND SPEED 3- SECOND GUST AND EXPOSURE "B" WIND ZONE noepffler —VAN HEMERT __j SHEET A —O 01 13 COCA Ca GIZ b `rte w a noepffler —VAN HEMERT __j SHEET A —O 01 13