13-459-004N
S 9 S
RELOCATED 60 DIA DOWN-
: -LIGHT FIXTURE (TYPICAL
REPAIR EXISTING ACOUS-
TICAL SUSPENSION GRID
AS- REQUIRED (TYPICAL)
2 X 2 RECESSED RETURN
AIR GRILLE TO MATCH --
EXISTING (TYPICAL OF 4)
f
SEVENTH FLOOR
REPAIR EXISTING ACOUS-
TICAL SUSPENSION GRID
AS REQUIRED (TYPICAL)
RELOCATED 2 X 2 RECESS
PRISMATIC FLUORESCENT
LIGHT FIXTURE (TYP OF 1)
WALL MOUNTED
EMERGENCY LIGHT
FIXTURE (TYP OF 3)
2 X 4 RECESSED PRISMATIC
FLUORESCENT LIGHT FIXTURE
(MATCH EXISTING)
WINDOW TREATMENTS
(TYPICAL)
REPAIR EXISTING ACOUS-
TICAL SUSPENSION GRID
AS REQUIRED (TYPICAL)
CEILING FLAN
SCALE 1/4'1= 1" -0"
u .. E.
ITEM
THICKNESS
DESCRIPTION
WATER CLOSET
URINALS
3 5/8 " METAL STUD FRAMING le"' O/G WITH ONE LAYER OF 5/8 " FIRE RATED TYPE "X" GYPSUM BOARD ON
O
41/8"
EACH SIDE AND 3 1/2" SOUND ATTENUATION INSULATION TO STRUCTURE ABOVE. (UL " U465) 1 -HOUR FIRE RATED
Q
TOILET
ASSEMBLY. FIRE SEAL ALL GAPS AND PENETRATIONS
B
41/8"
3 5/8 " METAL STUD F RA MIN G 16 " O/C A O YE E XISTI NG PARTITION HEADER TRACK WITH ON E LAYER OF 5/5"
FIRE RATED TYPE "X" GYPSUM BOARD ON EACH SIDE AND 3 1/2" SOUND ATTENUATION INSULATION TO
.............:......
ELEVATIONS
STRUCTURE U GTU RE ABOVE. 1 - HOU FI RE RA TED ASSEMBLY. FIRE SEAL ALL GAPS AND PENETRATIONS
EQUIPMENT
Q
3 5/8'" METAL STUD FRAMING o 16 "" O/C WITH ONE LAYER OF 5/8 "" GYPSUM BOARD ON EACH SIDE TO 41" ABOVE
<s>
41/8 ""
FINISH CEILING.
O
WALL ASSEMBLY
3 5/8" METAL STUD FRAMING a 16" O/C IN EX15TING DOOR OPENING WITH ONE LAYER OF 5/8" GYPSUM BOARD
O
41/8"
ON EACH SIDE. PATCH 4 MATCH ADJACENT FINISHES AS REQUIRED.
INSULATED
5/8 " GYPSUM BOARD ON ONE SIDE. PATCH 4 MATCH ADJACENT FINISHES AT ALL REMOVED WALL INTERSECTIONS
E
-
AND S ELE CTI VE DEMOLITION AREAS.
O-
EXISTING TO REMAIN. PATCH 4 MATCH ADJACENT FINISHES AS REQUIRED.
Q
i-
F>AfRT 1A
SEVENTH FLOOR
....................................................... ...............................
DETAILS S
L
O
OOM R
WATER CLOSET
URINALS
LAVATORIES
NUMBERS
1/25 1
Q
TOILET
::#V ...............................
INTERIOR
................ ...............................
ACCESSORIES
.............:......
ELEVATIONS
❑
EQUIPMENT
Q
DOOR NUMBER
EXISTING WALLS
E=
O
WALL ASSEMBLY
NEW PARTITION
INSULATED
PARTITION
F>AfRT 1A
SEVENTH FLOOR
....................................................... ...............................
................
BUSINESS OCCUPANCY 1,239 SF + 100 SF /OCCUPANT = 12 PERSONS
12 PERSONS
WATER CLOSET
URINALS
LAVATORIES
REQUIRED FIXTURES
1/25 1
1/40- 1
::#V ...............................
................ ...............................
.............:......
i DRINKING FOUNTAIN PER 100 PERSONS (1 REQUIRED)
I SERVICE SINK ( 0 REQUIRED)
• ALL REQUIRED PLUMBINCs FIXTURES ARE PROVIDED
2 PROVIDED
1 PROVIDED
IN COMMON AREAS
SCALE 114"z 1 " -0"
RECEPTION
FRONT DESK 4 OFFICES
GROUP ROOM
TOTAL OCCUPANT LOAD
3 WAITING
6 EMPLOYEES
6 PATIENTS
15 PERSONS
EXISTING FIRE EXTINGUISHERS ARE 2AI05C WITH WALL
MOUNTED BRACKET g 48 " AFF (1 PER 3,000 SF). VERIFY
OPERATION AND RE- CHARGE AS REQUIRED TO COMPLY
WITH NF-PA 10. (1,239 SF /3,000 = I REQUIRED)
MINIMUM INTERIOR FINISH CLASSIFICATION FOR EXITS,
EXIT ACCESS AND OTHER SPACES SHALL BE CLASS
"B" FLAMESPREAD 26 -15, SMOKE DEVELOPED 0 -450