13-459-001GENERAL NOTE5 1. CONTRACTOR SHALL COMPLY WITH ALL LOCAL, STATE AND FEDERAL BUILDING CODES. PERMIT SHALL BE POSTED ON A VISIBLE LOCATION AT ALL TIMES. 2. CONTRACTOR TO REMOVE, RELOCATE OR RE -ROUTE AS NECESSARY ELECTRICAL, WATER GAS, OR ANY OTHER UTILITY LINES ENCOUNTERED DURNG CONSTRUCTION. 3, CONTRACTOR MUST NOTIFY ARCHITECT IMMEDIATELY OF ANY UNEXPECTED OR UNKNOWN CONDITIONSANY DISCREPANCIES WITH THE DRAWINGS AND /OR THE CONTRACT DOCUMENTS, ANY ERRORS AND OMISSIONS ON THE DRAWINGS AND/ OR THE FIELD PRIOR TO PROCEEDING WITH WORK AND /OR SHOP FABRICATION. 4. CONTRACTOR TO OBTAIN WRITTEN APPROVAL FROM OWNER'S REPRESENTATIVE OR ARCHITECT PRIOR TO ANY CHANGES OR DEVIATION FROM CONTRACT DOCUMENTS. 5, DRAWINGS NOT TO BE SCALED. DIMENSIONS TO BE FOLLOWED. 6. ALL DIMENSIONS ARE BASED ON NOMINAL SIZES OF MEMBER AND ARE GIVEN TO THE OUTER FACE OF SUCH MEMBERS, NOT TO FACE OF FINISH MATERIALS, UNLESS OTHERWISE NOTED ON THE DRAWINGS. THE PLANS AND CALCULATIONS HAVE BEEN PREPARED TO COMPLY WITH THE REQUIREMENTS OF THE 2010 FLORIDA BUILDING CODE. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF THE 2010 FLORIDA BUILDING CODE, 2010 FLORIDA FIRE PREVENTION CODE, AND WITH THE REQUIREMENTS OF THE LOCAL BUILDING OFFICIAL. g, PROVIDE AND INSTALL FIRE EXTINGUISHERS PER FIRE MARSHALL'S REQUIREMENTS AND THE 2010 FLORIDA FIRE PREVENTION CODE. g ALL EXTERIOR PRE- MANUFACTURED ITEMS SHALL COMPLY WITH MIAMI DADE COUNTY PRODUCT APPROVAL. 10. ALL EXTERIOR WINDOWS, LOUVERS, HOODS, AND DOORS SHALL COMPLY WITH MIAMI DADE COUNTY PRODUCT APPROVAL, WATER INFILTRATION TEST REQUIREMENTS AND WITH 201¢ FLORIDA BUILDING CODE REQUIREMENTS. SUBMIT SHOP DRAWINGS AND PRODUCT APPROVALS FOR ATTACHMENT METHODS 4 DETAILS. 11, ALL WOOD IN CONTACT WITH MASONRY AND / OR CONCRETE SHALL BE PRESSURE TREATED LUMBER 12. PROVIDE AND INSTALL WOOD BLOCKING FOR ALL WALL MOUNTED ACCESSORIES AND FINISHED MILLWORK 13. PROVIDE 20 GAUGE METAL STUDS AT ALL WALL - MOUNTED LAVATORIES, URINALS, AND WATER CLOSETS. FLUSH MECHANISMS SHALL BE OPPOSITE OF WALL. 14, REFER TO MECHANICAL, PLUMBING, ELECTRICAL, AND STRUCTURAL DRAWINGS FOR COORDINATION WITH THE ARCHITECTURAL DRAWINGS. ITEMS INDICATED ON THE ARCHITECTURAL DRAWINGS AND NOT SHOWN ON CONSULTANT DRAWINGS AND CONVERSELY, ITEMS SHOWN ON THE CONSULTANT DRAWINGS AND NOT INDICATED ON THE ARCHITECTURAL DRAWINGS SHALL ALL BE CONSIDERED PART OF THE WORK UNDER THIS CONTRACT. THE GENERAL CONTRACTOR SHALL NOT BE ENTITLED TO ADDITIONAL FEES FOR FAILING TO PROPERLY COORDINATE THE WORK BETWEEN THE TRADES. 15. TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMICIDES, NCLUOIING SOIL APPLIED PESTICIDES, BAITING SYSTEMS, AND PESTICIDES APPLIED TO WOOD, OR OTHER APPROVED METHODS or- TERMITE PROTECTION LABELED FOR USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION AND SHALL COMPLY WITH THE REQUIREMENTS OF THE 2010 FLORIDA BUILDING CODE SECTION 1816. UPON COMPLETION OF THE APPPLICATION OF THE TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: "THE BUILDING HAS RECIEVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES." 16. CONTRACTOR TO PROVIDE AS GUILTS, WARRANTIES, GUARANTEES, AND OPERATIONAL MANUALS ALONG WITH ALL THE REQUIRED CLOSE -OUT DOCUMENTS UPON SUBSTANTIAL COMPLETION. PROVIDE A 5% EXTRA STOCK OF ALL SPECIFIED FINISH ITEMS FOR OWNER USE. 1'1. PROVIDE AND INSTALL FLANGELESS ACCESS PANELS IN GYPSUM BOARD ; CEMENT PLASTER ASSEMBLIES REQUIRED BY MECHANICAL, ELECTRICAL, AND PLUMBING WORK COORDINATE LOCATION WITH ARCHITECT. 18 CONTRACTOR SHALL NOT SAWCUT, DRILL OR ALTER IN ANY FOR"(, THE EXISTING STRUCTURE WITHOUT PRIOR APPROVAL FROM THE BUILDING ENGINEER 19. CONTRACTOR TO REPAIR ALL EXISTING CONCRETE SLABS AFFECTED BY NEW WORK PATCH t MATCH ADJACENT SURFACES. 20. CONTRACTOR SHALL REMOVE ALL EXCESS MATERIAL AND SHALL CLEAN UP AND RESTORE THE SITE TO ITS ORIGINAL CONDITION OR BETTER ALL DAMAGE, AS A RESULT OF WORK UNDER THIS CONTRACT DONE TO EXISTING STRUCTURES, ACCESS ROADS, PAVED AREAS, CURBS, GUTTERS, SOD AREAS, TREES, UTILITY POLES OR UNDERGROUND LINES AND INCLUDING ALL OBSTRUCTIONS NOT SPECIFICALLY MENTIONED, SHALL BE REPAIRED AND RESTORED TO A CONDITION ACCEPTABLE TO THE ARCHITECT. 21. CONTRACTOR TO FIRE SEAL ALL GAPS AND PENETRATIONS THROUGH NEW AND /OR EXISTING FIRE RATED WALL ASSEMBLIES. G;ENEfRAL CONDITIONS 1. ALL CONSTRUCTION METHODS, MATERIALS, ETC, SHALL MEET OR EXCEED ANY AND ALL PERTINENT AND APPLICABLE BUILDING CODES, STANDARDS AND ORDINANCES. 2. PROVIDE A COMPLETE AND OPERATING INSTALLATION INCLUDING ALL NECESSARY ITEMS EVEN THOUGH SUCH ITEMS ARE NOT INCLUDED IN THE CONSTRUCTION DOCUMENTS. 3. ALL SUBCONTRACTORS SHALL MAKE A PROPER EXAMINATION OF THE PROJECT SITE TO BECOME FAMILIARIZED WITH THE EXISTING CONDITIONS AND CAREFULLY EXAMINE THE MOST CURRENT AVAILABLE CONSTRUCTION DOCUMENTS. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY FOR RESOLUTION, THROUGH THE GENERAL CONTRACTOR OF ANY AMBIGUITY, INCONSISTENCY, OR ERROR WHICH MAY BE DISCOVERED UPON EXAMINATION OF THE CONSTRUCTION DOCUMENTS OR OF THE SITE OR LOCAL CONDITIONS. NO EXTRA PAYMENTS SHALL BE APPROVED DUE TO ERRORS OR INCOMPLETE FIELD CONDITIONS REVIEW, SPECIFICALLY VERIFYING THAT THE NEW EQUIPMENT WILL FIT AS SHOWN ON DRAWINGS. 4. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND ALL THE SUBCONTRACTORS TO BID AND BUILD FROM THE MOST UP -TO -DATE SET OF CONSTRUCTION DOCUMENTS AVAILABLE. THE RELEASE AND USE OF PARTIAL SETS DURING BIDDING AND / OR CONSTRUCTION SHALL NOT RELIEVE THE CONTRACTOR'S RESPONSIBILITY FOR HIS WORK AND COORDINATION OF THE SAME WITH WORK BY OTHER TRADES. 5. WRITTEN DIMENSIONS GOVERN. DO NOT SCALE DRAWINGS. IF REQUIRED DIMENSIONS ARE NOT INDICATED OR SEEM TO BE IN ERROR PROMPTLY NOTIFY THE ARCHITECT FOR RESOLUTION. 6. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND SUBCONTRACTOR TO BE AWARE OF ALL THE COMMENTS MADE 6Y THE JURISDICTIONAL BUILDING DEPARTMENT UPON THE OFFICIAL SIGNED AND SEALED CONSTRUCTION DOCUMENTS JOBSITS FIELD SET AND SHALL INCORPORATE SAM WITHIN THE SCOPE OF WORK IT SHALL ALSO BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO NOTIFY THE ARCHITECT OF ANY AND ALL FIELD CHANGES ORDERED BY THE JURISDICTIONAL INSPECTORS AND OBTAIN WRITTEN APPROVAL OF ANY CHANGES BEFORE PROCEEDING. IT IS THE RESPONSIBILITY OF GENERAL CONTRACTOR TO PROVIDE COST OF REQUIRED CHANGES AT TIME OF APPROVAL REQUEST. 1, ANY AND ALL SUBSTITUTIONS TO THE CONSTRUCTION DOCUMENTS OR SPECIFICATIONS MUST BE EQUAL TO THE PERFORMANCE AND APPEARANCE AND MUST BE SUBMITTED TO THE ARCHITECT FOR NECESSARY REVIEW AND REQUIRED APPROVAL. ALLOW TEN BUSINESS DAYS REVIEW PERIOD FROM ARCHITECT'S RECEIPT OF SUBSTITUTION SUBMITTAL. ARCHITECT WILL DETERMINE ACCEPTABILITY OF ANY AND ALL SUBSTITUTIONS. THE SUBCONTRACTOR BEARS ALL ADDITIONAL COSTS OF UNACCEPTABLE SUBSTITUTION IF USED IN ORIGINAL 510. THE SUB- CONTRACTOR BEARS ALL ADDITIONAL COSTS FOR REMEDY IF UNAPIPROVED SUBSTITUTION ARE UTILIZED OR DISCOVERED. CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL TECHNICAL DATA SHOWING SUBSTITUTION IS EITHER EQUAL. OR BETTER THAN SPECIFIED PRODUCT AT THE TIME OF SUBSTITUTION APPROVAL REQUEST. ALL SUBMITTALS WILL BE RETURNED IF DATA IS NOT COMPARED TO SPECIFIED PRODUCT. S. SUBMIT SIX COPIES OF ALL PRODUCT SUBMITTALS REQUESTED BY THE ARCHITECT AND /OR THE JURISDICTIONAL AUTHORITY AND / OR THE GENERAL CONTRACTOR REQUIRED FOR CUSTOM FABRICATED WORK OR AS REQUIRED HEREIN. A MINIMUM OF TEN BUSINESS DAYS SHOULD BE ESTIMATED FOR PROPER REVIEW OF SUBMITTALS. S. NO RELATED WORK WILL BEGIN WITHOUT RELATED SUBMITTAL... 10. SUBSTITUTIONS WILL NOT BE CONSIDERED DUE TO SUBCONTRACTORS LACK OF PROPER AND TIMELY ORDERING, SCHEDULING AND /OR PLANNING. ALL LONG LEAD ITEMS SHALL BE IDENTIFIED AND SCHEDULED PRIOR TO CONSTRUCTION. 11_ IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO REVIEW ALL SUBMITTALS PRIOR TO SUBMITTING SAME TO THE ARCHITECT. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING ACTUAL EX15TNG CONDITIONS RELATED TO SUBMITTALS. 12. THE FOLLOWING PRODUCT SUBMITTALS WILL BE REQUIRED FOR THE RELATED WORK LIGHT FIXTURES, EMERGENCY LIGHTS, EXIT SIGNS, FIRE ALARM DEVICES, HVAC DEVICES, PRE -HUNG WOOD DOORS AND HARDWARE, AND FLOORIWALL/CEILING FINISHES. SHOP DRAWINGS ARE REQUIRED FOR: CABINETRY 13. CONTRACTOR SHALL COORDINATE CONSTRUCTION SEQUENCING WITH THE OWNER TO NOT INTERFERE WITH THE NORMAL OPERATION OF THE BUSINESS. ALL WORK GENERATING NOISE, SMELL AND DUST SHALL BE COORDINATED WITH THE OWNER 14. ANY POWER INTERUPTIONS SHALL BE SCHEDULED < COORDINATED WITH THE OWNER UNDER NO CIRCUMSTANCES IS ANY WORK TO BE DONE ON THE POWER, SPRINKLER, FIRE ALARM OR HVAC SYSTEMS WITH OUT COORDINATING WITH, AND OBTAINING APPROVAL FROM THE OWNER 15. REFER TO SITE PLAN FOR TEMPORARY CONSTRUCTION ACCESS LOCATION. ACCESS TO LOBBY 4 USE OF EXISTING TOILETS IS STRICTLY PROHIBITED. CONTRACTOR TO PROVIDE TEMPORARY TOILETS. illy LOCATION PLAN LEGAL DE5CRIFTION THE EAST 149 FEET OF THE NORTH 115 FEET OF THE EAST 1/2 OF THE SOUTH- EAST 1/4, OF THE SOUTHEAST 1/4, OF THE SOUTHWEST 1/4 OF SECTION 25, TOWNSHIP 54 SOUTH, RANGE 40 EAST AND THE SOUTH 130 FEET OF THE NORTH 245 FEET OF THE EAST 1/2 OF THE SOUTHEAST 1/4 OF THE SOUTHEAST 1/4 OF THE SOUTHWEST 1/4 OF SECTION 25, TOWNSHIP 54 SOUTH, RANGE 40 EAST, ALL BEING AND LYING IN DADE COUNTY, FLORIDA. OUTLINE 5FECIFICATION5 (EQUAL PRODUCTS FROM OTHER MANUFACTURERS WILL BE CONSIDERED) CARPET: 32 OZ. PATTERNED LOOP. DIRECT GLUE DOWN CARPET TO MATCH EXISTING. WOOD BASE: 4" HIGH POPLAR BASE BY "FEDERAL MILLWORK ", STANDARD PROFILE (STAIN GRADE) MATCH EXISTING PORCELAIN FLOOR TILE: 18" x 18" x 5/16" UNPOLISHED FLOOR TILE BY "CROSSVILLE ". INSTALL* 45' PATTERN. GROSS COLORS TO BE SELECTED. PORCELAIN COVE SASE: 6" x all x 5116" UNPOLISHED COVE BASE BY "CROSSVILLE ". CROSS COLORS TO BE SELECTED. PAINT: 2 COATS OF EGGSHELL LATEX OVER 1 COAT PRIMER FOR PARTITIONS. 2 -COATS OF SEMI -GLOSS ENAMEL FOR HOLLOW METAL FRAMES. COLOR TO BE SELECTED. WOOD DOORS: WEYERHAUSER TIMBERLAND CORE DPC -I, 1-3/411 SOLID CORE PARTICLE BOARD WITH BIRCH FACE VENEER PREMIUM GRADE I DOORS. (STAIN GRADE). COLOR TO BE SELECTED. HARDWARE: (MATCH EXISTING) B BUTTS: FULL MORTISE BALL BEARING HINGES -41/2" x 4V2" 1 1/2 PAIR (US26D), STANLEY F55168 C CLOSER: LCN 4040 (US26D) L LOCKSET: LEVER TYPE, GRADE 1, HEAVY -DUTY, (U626D) SCHLAGE S10D SATURN WS WALL STOP: ROCKWOOD 40S (US26D) FS FLOOR STOP: GJF1515 SERIES (US 26D) CEILING: 2411 x 241' x 3/4" LAY -IN (MATCH EXISTING) WHITE BY "ARMSTROWS" ON 15/1611 SNAP GRID, DOUBLE WEB SYSTEM, INTERMEDIATE DUTY (LOW SHEEN SATIN WHITE). WINDOW TREATMENTS: ROLL -UP SOLAR SCREENS WITH 10 PERFORATION BY "AMERICAN BLIND CORPORATION ", CHAIN CONTROL t VALANCE COLOR AND MATERIAL TO BE SELECTED (305) 262 -2009 INDEX OF DRAWINGS ARCHITECTURAL A -ID GENERAL NOTES, PROJECT DATA 4 MASTER SITE A -1.1 EXISTING BUILDING PLAN (SEVENTH FLOOR) A -2.0 ENLARGED DEMOLITION FLOOR 4 CEILING PLAN A -30 PARTIAL FLOOR 4 CEILING PLAN A -4-0 INTERIOR ELEVATIONS 4 DETAILS A -5.0 DOOR r FINISH SCHEDULES ME -I MECHANICAL PLANS AND DETAILS ME -2 ELECTRICAL PLANS AND DETAILS JURISDICTION CITY OF SOUTH MIAMI LAND USE TRANSIT ORIENTED DEVELOPMENT DISTRICT ZONING DISTRICT MIXED USE -5 TODD (MU -5) USE CATEGORY MEDICAL OFFICE OCCUPANCY CLASSIFICATION BUSINESS GROUP "B "• TYPE OF CONSTRUCTION TYPE IB FIRE SUPPRESSION SYSTEM STAND PIPE/FHC AREA OF REMODELING 1,239 SF. CLASSIFICATION OF WORK ALTERATION -LEVEL 2 FOLIO NUMBER 0g- 4025 -000 -0591 f f Pjt a �°4 ,..✓ ,✓F ., a .,. m ^ ., ^ ... .,......_....._.... ... ............ _..�. .......,.,......-.... . »..... ......,..............._.-...... ..................._.._.. ....._.....,..........._... ............... ..... ».._,........,.......... ...,......... ..k ., ., .. _ «. .,, .........._. SW 10TH STREET r t ms's in U' € ... . ....... . ....... EXI3 T INN RIESCO ARCHITECTS 1VEW, r pil F € F € € 1750 PONCE DE LEON BLVD : CORAL GABLES, FL 33134 305.448.4288 305.444.4986 tu = I F € € t I F € I € flii. 1 L i g G Y� J x Ul r E € z Fr EX1 TIN 11�EF € i I .../ t c E ° E e E I; t B € MASTER SITE PLAN SCALE 1"= 30' -0" )UTHMIA IG DepT. 4/ WATER- , 11 E.=lr_(\00N --�5EVENTH FL00fR 5ULDING FLAN - '- -� EXISTING SCALE 1/16 " = 1' -011 Y 1"• It �: 1 11 : J1 •' ' �!" DI: t1 an CO I am • U. 1 0 8 cn w 1 w cf3 0 D Cc z w w C . 0 w z c*j • 0 a. CD u cn c • IL 0 0 • .i 107 ; 'N I� 04/03/13 SHEEr A-1.0 OF 7