Loading...
12-707-02275cd 75cd 75cd 75cd 75cd 75cd 75cd 75cd 75cd 75cd 75cd DESCRIPTION FA0.1 FIRE ALARM NOTES, LEGEND & INDEX FA2.1 FIRE ALARM PLAN F EMOTE 1 POWER SUPPLY L _(RPSL J I r -1 f -- LJP_ LJP -- 2p— �2F— 2F INTERCEPT EXISTING FIRE ALARM INITIATING CIRCUIT, EXTEND TO NEW LOCATION OF DEVICE AND CONNECT FOR OPERATION. I I I I I I rrr r III I III I IIIII� illlll Iillll I I I I (.IL— --`2L— M_ r� I I I I T �P LJ �� P P IIIIIII �P IIIIIII IIIIIII IIIIIII � IIIIIII .L � - -- LIJ r —n—RE- 1 1 r 1 � � MAIN � r , 1 1 FIRE ALARM REMOTE I CONTROLLER I I ALARM ( I COMMUNICATOR I I ANNUNCIATOR I I I CONTROL ( ( TRANSMITTER N PANEL I I PANEL I L_.r_J i (FACP) i L__T__J L__T__J III I I L----- - - - -- J I L-- - - - --� I L-------------- - - - - -- SEVENTH FLOOR SECOND FLOOR FIRST FLOOR FIRE ALARM SYSTEM WIRE SCHEDULE: FIRE ALARM SYSTEM SHALL BE POWER LIMITED • INITIATING CIRCUITS: 4 CONDUCTOR, #18 AWG SOLID, SHIELDED TWISTED PAIR • INDICATING CIRCUITS: 2 CONDUCTOR, #14 AWG SOLID, SHIELDED CABLE • ALL CONDUCTORS SHALL BE INSTALLED IN ELECTRICAL TUBING (EMT) UNLESS OTHERWISE NOTED. • PLENUM RATED FIRE ALARM CABLE IS ACCEPTABLE FOR USE WHERE APPROVED BY THE AUTHORITY HAVING JURISDICTION. FIRE ALARM RISER DIAGRAM NOT TO SCALE P P FIRE ALARM SHEET INDEX 3HEETf DESCRIPTION FA0.1 FIRE ALARM NOTES, LEGEND & INDEX FA2.1 FIRE ALARM PLAN FIRE ALARM NOTES 1. ALL NEW EQUIPMENT AND DEVICES SHALL BE U.L. LISTED FOR FIRE SERVICE AND SHALL BE COMPATIBLE WITH THE EXISTING SYSTEM IN USE 2. ALL WIRING AND CONDUIT TO CONFORM TO N.F.P.A. 72 AND N.E.C. ARTICLE 760. WIRING SHALL BE SOLID COPPER OR STRANDED COPPER WITH A MAX. OF 7 STRANDS FOR 16 GA AND 18 GA, STRANDED COPPER WITH A MAX.OF 19 STRANDS FOR SIZES 14 AND LARGER PER N.E.C. 760 AND N.F.P.A. 70. 3. ALL FIRE STOP PENETRATIONS SHALL BE MADE WITH APPROVED (NEC) METALLIC CONDUIT AND SHALL BE SEALED WITH A U.L. APPROVED FIRE STOP MATERIAL. (SEE FIRE STOP DETAIL) 4. COLOR CODING MAY NOT APPLY TO EXISTING SYSTEMS. LABEL EXISTING WIRING ACCORDINGLY. 5. ROUTING OF THE FIRE ALARM SYSTEM CONDUIT IS DIAGRAMMATIC ONLY, VERIFY EXACT LOCATIONS PRIOR TO STARTING WORK. 6. ALL FIRE ALARM NOTIFICATION APPLIANCES SHALL ACTIVATE UPON INITIATION OF THE GENERAL ALARM. 7. ALL FIRE ALARM AUDIBLE SIGNALS IN OPEN AREA SHALL HAVE A THREE PLUS TEMPORAL PATTERN. 8. ALL FIRE ALARM AUDIBLE SIGNALS SHALL HAVE A SOUND LEVEL OF AT LEAST 15 dba ABOVE THE AVERAGE ABMBIENT SOUND LEVEL. 9. MANUAL STATIONS TO BE INSTALLED AT 48" INCHES A.F.F. 10. MOUNT FIRE ALARM SYSTEM AUDIBLE /VISUAL SIGNALS (COMBINATION DEVICES) SUCH THAT THE ENTIRE STROBE LENS IS 80" A.F.F. OR 6" BELOW CEILING, WHICHEVER IS LOWER. 11. MOUNT FIRE ALARM SYSTEM STROBES SUCH THAT THE ENTIRE STROBE LENS IS 80" A.F.F. OR 6" BELOW CEILING, WHICH EVER IS LOWER. 12. SMOKE DETECTORS TO BE INSTALLED AS REQUIRED BY N.F.P.A. 72. 13. THE FIRE ALARM PANEL MUST HAVE AN EARTH GROUND CONNECTION AS REQUIRED BY THE SYSTEM MANUFACTURER, AND N.E.C. ARTICLE 760. MINIMUM WIRE SIZE IS AWG FOR GROUND CONNECTION. (NOTE PANEL NEUTRAL OR CONDUIT GROUND IS NOT ACCEPTABLE 14. A GENERAL ALARM SHALL BE ANNUNCIATED UPON ACTIVATION OF ANY PULL STATION, FLOW SWITCH OR DETECTION DEVICE. 15. A TROUBLE SIGNAL SHALL BE ANNUNCIATED UPON FAILURE OR REMOVAL OF ANY DETECTION OR MANUAL DEVICE. 16. A SUPERVISORY SIGNAL SHALL BE ANNUNCIATED UPON ACTIVATION OF ANY FIRE SPRINKLER SYSTEM TAMPER SWITCH. 17. HVAC DUCT SMOKE DETECTORS SHALL BE CONNECTED TO THE FIRE ALARM CONTROL PANEL AND SHALL INITIATE A SUPERVISORY SIGNAL ONLY. 18. ALL FIRE ALARM SYSTEM DEVICES INSTALLED FOR THIS SPECIFIC PROJECT SHALL BE U.L. CERTIFIED. 19. ALL FIRE ALARM INITIATING DEVICES SHALL BE ADDRESSABLE AND ALL FIRE ALARM CIRCUITS SHALL BE CLASS "B ", STYLE "C ". 20. SECURITY LOCK SYSTEM (BY OTHERS) SHALL BE TIED INTO FIRE ALARM SYSTEM. EMERGENCY EXITS SHALL UNLOCK UPON RECEIPT OF ANY FIRE SIGNAL OR LOSS OF PRIMARY POWER. 21. PROVIDE CERTIFICATE OF COMPLETION AT THE FINAL INSPECTION OF THE FIRE ALARM SYSTEM. 22. FIRE ALARM CONTRACTOR SHALL PROVIDE A DETAILED SET OF SHOP DRAWINGS (INCLUDING DEVICE CUT SHEETS), A COMPLETE POINT TO POINT WIRING DIAGRAM, FLOOR PLAN DRAWINGS INDICATING ALL DEVICE LOCATIONS AND NUMBERS, COMPLETE BATTERY CALCULATIONS AND COMPLETE NOTIFICATION APPLIANCE CIRCUIT CALCULATIONS (FOR THE SYSTEM TO BE INSTALLED) TO THE BUILDING DEPARTMENT (AUTHORITY HAVING JURISDICTION) AT THE TIME OF APPLICATION FOR BUILDING PERMIT. 23. PROVIDE THE OWNER WITH A COMPLETE FIRE ALARM SYSTEM AND INSTALLATION MANUAL COVERING MANUAL COVERING ALL SYSTEM EQUIPMENT INSTALLED FOR THIS PROJECT. KEEP AT THE MAIN FIRE ALARM CONTROL PANEL. FIRE ALARM SYMBOLS ElP FIRE ALARM MANUAL PULL STATION. (EXISTING TO REMAIN) OP PHOTOELECTRIC SMOKE DETECTOR. (EXISTING TO REMAIN) FF-A-FF9 FIRE ALARM CONTROL PANEL — ADDRESSABLE. (EXISTING TO REMAIN) F—RPS--j REMOTE POWER SUPPLY. (EXISTING TO REMAIN) 75 cd FIRE ALARM SPEAKER / STROBE COMBINATION. NUMERAL ® ADJACENT TO DEVICE INDICATES CANDELA RATING. (MATCH EXISTING SYSTEM) D0 N0T INSTALLL,ARM tractor's tvor - nr plans shall Fire Alarm �err,.it appro "al to N"'aml- be submitted for T✓ Ir. Department, Dkde County .... �yt AP e for B i' 'ing Pe Date >3v 75 cd FIRE ALARM STROBE. NUMERAL ADJACENT TO DEVICE %QJ INDICATES CANDELA RATING. (MATCH EXISTING SYSTEM) ISSUED FOR PERMIT IN1111l�[Ip� ISSUED FOR CONSTRUCTION KAMM CONSULTING PROJECT #: 20: PROJECT MANAGER GREG KEMP A"m M 1407 Deerf Phone :�t Newport Center rDK e ; B*aifi. Florida 344442 of Authorization t 1$� a�SN3"?s -12 • PJESCO ARCHITECT3 1750 PONCE DE LEON BLVD CORAL GABLES, FL 33134 305.448.4288 305.44 AN6 AA0002678 SEAL KAMM CONSULTING 1407 W. Fe 1VPOFfT CB�lTt�i ORVE DAD BEACH, FL 33442 (g64) M-2MO FAX (964) 949'M < LL a. I— � o Lz F- =) 8 WU�� J w W Qw z D z O cf) 0 ow�� � o am °� PROJECT NUMBER 2012 -0423 DATE 07 -06 -12 SHEET FA0,1