Loading...
12-707-003,.� EXISTING f -OERi = = F-4"E D DEM :ZINC PARTfT ON TO REt�`A N ............ T ....................... I .......... F 1 , 19 sw?. EXIT i ING- 4 E Xf$TfNG GYr-=U' -1 OA° Cf TO R.w�AiN 4 EX €6TINS 5TO :.FRONT l.IiINDOLJ 6'y15 -1 M °°0 REMA fN 4 PROPOSED SCOPE OF WORK ONLY INCLUDES INTERIOR IMPROVEMENTS WITHIN EXISTING BUILDING. NO EXTERIOR WORK OR STRUCTURAL MODIFICATIONS ARE INCLUDED. EX16T :NC 42" HIGH ^LID CUARCRAIL . ......... ......................................... .............. ... . EX1617I N » 5 °RJCTU -RA:: COLO -IN TO REMAfN (TYPICAL) Q CONTRACTOR TO PROTECT 4 RESTORE EXISTING; FLOOR, WALL, AND CEILING FINISHES IN AFFECTED ROOMS WITHIN SUITE PH -F (SOUTH OF GRID LINE 8) EXI;,TfNG X D GLAZING. SYSTEM "O REMAIN ;TAP) EXfTINC GYPSUM BOARD 0FEN[Nrz TC RR IIA €N (T'`' F €C.^,L ) 4 --- ------------- - - 14 15 _ 1 1 22 22 A/, 22 L - -- ----- - - - - -� 24 OII 6 22 O I I 16 35 31 30 O 10 I I �r- - -•�-- ' '�' 31 30 I I OO� 35 I I I I i� II I OO II 12 II 11 II 38 r, I I III I �O I I O I I Oi /r I <1 i �� 6 L----------------- - - - - -� I I'I 11 I I 11 O 12\ I I 11 gl 1:1 I L— --------------- - - - --/ 1 I I II 16 1r------------ - - - - -- II I 6 31 O O O jj \ O I I O I•I O I I I I O O O DEMOLISH I I EXISTING low- II 35 38 32 II II \ 33 35 I I 10 I ____ -- _�� r :s a, L - - - - -- O — O - -_j7 r I I I�1 ------ _-- I r 1 1 • I O I I I � O 6 I A/A 30 35 1 10 31 30 35 1 I :I \\ I L - - -- 19 - - - - - -- — I 29 — _ =� -- ' ' O �________ _ ____� r�r :O 1� 23 I I 911 :I `._ -� 29 12 __---1 38 29 ?? I 1 4 __....._. :....... I �. �. ................... ........... �.............�..: 1................ ................... ..........................1. :�. ------ ., ?�.. /.-\\..................1 :1�j. ......... - - -_ --- - - - - -- r 4 11 1 i ` LL - - - - - -� - - - -- —J — 3 O: O 4 -- - -- I \ I 6 3-1 wra O : 38 10 35 31 32 38 `� ``\ I O O UI E i � OOOO I� 4 \\ UO '1 \ I I O O• I OI \\ I : 35 38 29 10 \\ DEMOLISH EXISTING OOO 32 O 19 O I EXISTING BEM '�isH 25 111 26 28 8 6 36 I I L� -- --- - - - - -- ----- - - - - -- ------------------- - - -� -- F -I —� n i 38 i r— -- � ,A� r------ - - - - -� AA� 1 O olg.�� \\ 'j . � - - -- —�7 -- —� Gil , • I I ( I I I I I \ // I I � A/ I I 11 I I \\ �/ I I � r/ I I • I L_____ J I —J I I I I •I : 31 32 I rri O O I ILP ( I I I O O O I I I I I I I I t I I I L�'CI �[ II I O g-1 0110 II 11 I I I lO 31 10 38 O OO 21 I I I� O II 16 31 II 6 16 31 OII 6 16 31 33 11 I I OOO II I OI I ( I I I O O I I O G) 1 1 I� O o Sol I 35 11 1 I ( I I I 36 oil 1 1 S 35 I I 33 1 1 3$ : 11 35 29 16 1 1 O OL I I I 1 1 O 11 O 35 1 I (�: I I DEMcLibw : EXISTING \ II I II • I I II I �' � 12 j1 _ I I I I I I I I :I ',i II II II II II •I • I III 1 _______!..._.�..... I I 11 I I I I •I 9 I ( I I I 22 18 — I I 22 1 122 I I 22 13 22 r pEMOLITION NOTES :SANG: E EXIaTINeG (`- a40I,�R) FIRE RATED D EMf5NC. PARTI T ION TO REMAIN G H A\1111 G41: o v \ r EX1 '11N C, `10 fR L /E3E3'1' EXISTINC. N -HOUR) SIRE RATEf� �° "``I�INC PART 1T::#0`\-1 TO RE!'A IN rel ARTI T ION 170 REMAIN OCAREFULLY REMOVE EXISTING DOUBLE DOOR/HARDWARE/FRAME. STOCKPILE II REMOVE ALL EXISTING ELECTRICAL OUTLETS, TELEPHONE/DATA OUTLETS AND AND STOCKPILE FOR OWNER'S REUSE. FOR REUSE. O31 J -BOXES O REMOVE EXISTING ELECTRICAL OUTLETS, SWITCHES 4 PUSH BUTTONS 12 REMOVE EXISTING WALL MOUNTED LIGHT SWITHES (TYPICAL) O REMOVE EXISTING J -BOX 13 CAREFULLY SAWCUT 4 REMOVE PORTION OF EXISTING GYPSUM PARTITION. PREPARE PLAN. 12200 33 OPENING TO RECEIVE NEW DOOR OCAREFULLY SAWCUT 4 REMOVE PORTION OF EXISTING GYPSUM BOARD ENCLOSURE. FIELD VERIFY EXSITING CHASE FOR VERTICAL PIPING, CONDUITS, WIRING, ETC. 14 REMOVE EXISTING PLASTIC LAMINATE COUNTERTOP, BACKSPLASH 4 BASE CABINETS OREMOVE EXISTING GLASS /ALUMINUM WINDOW SYSTEM AND ASSOCIATED FRAMING COMPONENTS 15 REMOVE EXISTING WALL MOUNTED PLASTIC LAMINATE FIXED SHELVES /CABINETS O CAREFULLY SAWCUT 4 REMOVE PORTION OF EXISTING GYPSUM BOARD PARTITION. 16 O REMOVE EXISTING CARPET AND VINYL BASE. PREPARE SURFACE TO RECEIVE NEW 07/06/12 HANGAR WIRES (TYPICAL) FLOOR AND BASE FINISH. (D REMOVE EXISTING PRE -HUNG WOOD DOOR FRAME 4 CASINGS REMOVE EXISTING CERAMIC TILE FLOORING AND BASE. PREPARE SURFACE TO O CAREFULLY REMOVE EXISTING WALL MOUNTED HVAC SYSTEM THERMOSTAT AND ll RECEIVE NEW FINISH ASSOCIATED CONTROL WIRING. STOCKPILE FOR RELOCATION 18 CAREFULLY REMOVE EXISTING SECURITY ALARM KEYPAD AND ASSOCIATED OCAREFULLY 9 REMOVE EXISTING WALL MOUNTED FIRE ALAM DEVICES AND CONTROL CONTROL WIRING. FIELD VERIFY EXISTING CONDITIONS AND SYSTEM. WIRING. STOCKPILE FOR RELOCATION. 19 CAREFULLY REMOVE EXISTING WOOD DOOR, HARDWARE 4 HOLLOW METAL FRAME. Im REMOVE EXISTING PORCELAIN FLOOR TILE 4 WOOD BASE. PREPARE SURFACE STOCKPILE FOR REUSE. TO RECEIVE NEW FLOOR 4 BASE FINISH. 20 REMOVE EXISTING VINYL TILE FLOORING AND VINYL BASE. PREPARE SURFACE TO RECEIVE NEW FINISH DEMOLITION FL00fR/GE1L1NG FLAN (PARTIAL SEVENTH FLOOR) O21 REMOVE EXISTING PLASTIC LAMINATE BASE/UPPER CABINETS AND UTILITY SINK CAP ALL ASSOCIATED SANITARY AND DOMESTIC WATER PIPING O22 PATCH 4 MATCH ADJACENT FINISHES AT ALL DEMOLISHED WALL INTERSECTIONS (TYPICAL) 23 REMOVE EXISTING PLASTIC LAMINATE BASE CABINET, SINK, TOILET t WALL MOUNTED ACCESSORIES. CAP ALL ASSOCIATED SANITARY AND DOMESTIC WATER PIPING 24 REMOVE EXISTING PORCELAIN TILE FLOORING AND BASE. PREPARE SUWACE TO RECEIVE NEW FINISH. FIELD VERFIY WATERPROOFING MEMBRANE BELOW 25 CAREFULLY REMOVE EXISTING WALL MOUNTED FIRE EXTINGUISHER CABINET. STOCKPILE FOR REUSE 16 REMOVE EXISTING BI -FOLD DOOR AND OVERHEAD TRACK T� NOT USED 28 REMOVE EXISTING DOOR CHIME AND ASSOCIATED CONTROL WIRING Z9 SAWCUT 4 REMOVE EXISTING PORTION OF GYPSUM BOARD CEILING SUSPENSION SYSTEM AND HANGAR WIRES. SCALE 1 /4 "= 1' -0" RIIESCO ARCHITECTS 1750 PONCE DE LEON BLVD CORAL GABLES, FL 33134 305.448.4288 305,444.4986 AA0002678. r At 1 , SEAL DBSI ARRANQEAffiJIS BY TM DRAWM ARE OWNED M THS PROFEERTY OF THIS OF- :r vr• KAMM CONSULTING 1407 W. NEIIYPOFii' CTFL DHVE DEEfBD BEAC 33442 0A) W-nM FAX 00 W= ��ao zH�� o `z j � WUNLu J a � J w W Qw F. W > z =a D 0 z O cf)� � LJLJo a. o Q mo � REVISIONS 30 REMOVE EXISTING; PARABOLIC LIGHT FIXTURES. VERIFY FIXTURE OPERATION, LAMPS AND STOCKPILE FOR OWNER'S REUSE. O31 REMOVE EXISTING HVAC SUPPLY DIFFUSERS AND RELOCATE AS INDICATED ON THE CEILING PLAN. PROJECT NUMBER 34 REMOVE EXISTING HVAC RETURN GRILL AND RELOCATE AS INDICATED ON CEILING PLAN. 12200 33 REMOVE EXISTING PRISMATIC LIGHT FIXTURES. VERIFY FIXTURE OPERATION, LAMPS AND STOCKPILE FOR OWNER'S REUSE. OCAREFULLY REMOVE EXISTING SMOKE DETECTOR AND ASSOCIATED CONTROL DATE WIRING. STOCKPILE FOR RELOCATION. 35 REMOVE EXISTING ACOUSTICAL CEILING TILES, SUSPENSION GRID AND ASSOCIATED 07/06/12 HANGAR WIRES (TYPICAL) 36 REMOVE EXISTING MOTION SENSOR AND PUSH BUTTON FOR MAGNETIC DOOR RELEASE, AND ASSOCIATED CONTROL WIRING. SHEET 3l CAREFULLY REMOVE EXISTING EMERGENCY EXIT SIGN. STOCKPILE FOR OWNER REUSE 3S REMOVE EXISTING RECESSED DOWNLIGHT FIXTURES. STOCKPILE FOR OWNER REUSE A-2.0 39 REMOVE EXISTING WALL MOUNTED EMERGENCY LIGHTS. STOCKPILE FOR OWNER REUSE OF 8