12-707-001GENEFRAL NOTES
1. CONTRACTOR SHALL COMPLY WITH ALL LOCAL, STATE AND FEDERAL BUILDING CODES. PERMIT SHALL BE
POSTED ON A VISIBLE LOCATION AT ALL TIMES.
2. CONTRACTOR TO REMOVE, RELOCATE OR RE -ROUTE AS NECESSARY ELECTRICAL, WATER GAS, OR ANY
OTHER UTILITY LINES ENCOUNTERED DURING CONSTRUCTION.
3, CONTRACTOR MUST NOTIFY ARCHITECT IMMEDIATELY OF ANY UNEXPECTED OR UNKNOWN C0NDITIONSAANY
DISCREPANCIES WITH THE DRAWINGS AND /OR THE CONTRACT DOCUMENTS, ANY ERRORS AND OMISSIONS ON
THE DRAWINGS AND/ OR THE FIELD PRIOR TO PROCEEDING WITH WORK AND /OR SHOP FABRICATION.
4. CONTRACTOR TO OBTAN WRITTEN APPROVAL FROM OWNER'S REPRESENTATIVE OR ARCHITECT PRIOR TO
ANY CHANGES OR DEVIATION FROM CONTRACT DOCUMENTS.
5, DRAWINGS NOT TO BE SCALED. DIMENSIONS TO BE FOLLOWED.
ALL DIMENSIONS ARE BASED ON NOMINAL SIXES of MEMBER AND ARE GIVEN To THE OUTER FACE OF SUCH
MEMBERS, NOT TO FACE OF FINISH MATERIALS, UNLESS OTHERWISE NOTED ON THE DRAWINGS.
THE PLANS AND CALCULATIONS HAVE BEEN PREPARED TO COMPLY WITH THE REQUIREMENTS OF THE 2010
FLORIDA BUILDING CODE. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF
THE 2010 FLORIDA BUILDING CODE, 2010 FLORIDA FIRE PREVENTION CODE, AND WITH THE REQUIREMENTS
OF THE LOCAL BUILDING OFFICIAL.
g_ PROVIDE AND INSTALL FIRE EXTINGUISHERS PER FIRE MARSHALL'S REQUIREMENTS AND THE 2010 FLORIDA
FIRE PREVENTION CODE.
ALL EXTERIOR PRE - MANUFACTURED ITEMS SHALL COMPLY WITH MIAMI DADE COUNTY PRODUCT APPROVAL.
10. ALL EXTERIOR WINDOWS, LOUVERS, HOODS, AND DOORS SHALL COMPLY WITH MIAMI DADE COUNTY
PRODUCT APPROVAL, WATER INFILTRATION TEST REQUIREMENTS AND WITH 2010 FLORIDA BUILDING CODE
REQUIREMENTS. SUBMIT SHOP DRAWINGS AND PRODUCT APPROVALS FOR ATTACHMENT METHODS 4 DETAILS.
11, ALL WOOD IN CONTACT WITH MASONRY AND / OR CONCRETE SHALL BE PRESSURE TREATED LUMBER
12. PROVIDE AND INSTALL WOOD BLOCKING FOR ALL WALL MOUNTED ACCESSORIES AND FINISHED MILLWORK
13. PROVIDE 20 GAUGE METAL STUDS AT ALL WALL - MOUNTED LAVATORIES, URINALS, AND WATER CLOSETS.
FLUSH MECHANISMS SHALL BE OPPOSITE OF WALL.
14, REFER TO MECHANICAL, PLUMBING, ELECTRICAL, AND STRUCTURAL DRAWINGS FOR COORDINATION WITH
THE ARCHITECTURAL DRAWINGS. ITEMS INDICATED ON THE ARCHITECTURAL DRAWINGS AND NOT SHOWN
ON CONSULTANT DRAWINGS AND CONVERSELY, ITEMS SHOWY`! ON THE CONSULTANT DRAWINGS AND NOT
INDICATED ON THE ARCHITECTURAL DRAWINGS SHALL ALL BE CONSIDERED PART OF THE WOfa'IK UNDER
THIS CONTRACT. THE GENERAL CONTRACTOR SHALL NOT BE ENTITLED TO ADDITIONAL FEES FOR
FAILING TO PROPERLY COORDINATE THE WORK BETWEEN THE TRADES.
15. TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMICIDES, INCLUDIING SOIL APPLIED
PESTICIDES, BAITING SYSTEMS, AND PESTICIDES APPLIED TO WOOD, OR OTHER APPROVED METHODS Or-
TERMITE PROTECTION LABELED FOR USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION AND
SHALL COMPLY WITH THE REQUIREMENTS OF THE 2010 FLORIDA BUILDING CODE SECTION 1816. UPON
COMPLETION OF THE APPPLICATION OF THE TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF
COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL
COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: "THE BUILDING HAS R= CIEVED A COMPLETE
TREATMENT FOR THE PRE=VENTION OF SUBTERRANEAN TERMITES. TREATMENT IS IN ACCORDANCE WITH
RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER
SERVICES."
16. CONTRACTOR TO PROVIDE AS BUILTS, WARRANTIES, GUARANTEES, AND OPERATIONAL MANUALS ALONG
WITH ALL THE REQUIRED CLOSE -OUT DOCUMENTS UPON SUBSTANTIAL COMPLETION. PROVIDE A 5%
EXTRA STOCK OF ALL SPECIFIED FINISH ITEMS FOR OWNER USE.
PROVIDE AND INSTALL FLANGELESS ACCESS PANELS IN GYPSUM BOARD 4 CEMENT PLASTER ASSEMBLIES
REQUIRED BY MECHANICAL, ELECTRICAL, AND PLUMBING WORK COORDINATE LOCATION WITH ARCHITECT.
18. CONTRACTOR SHALL NOT SAWCUT, DRILL OR ALTER IN ANY FORM, THE EXISTING STRUCTURE WITHOUT PRIOR
APPROVAL FROM THE BUILDING ENGINEER
19. CONTRACTOR TO REPAIR ALL EXISTING CONCRETE SLABS AFFECTED BY NEW WORK PATCH t MATCH
ADJACENT SURFACES.
20. CONTRACTOR SHALL REMOVE ALL EXCESS MATERIAL AND SHALL CLEAN UP AND RESTORE THE SITE TO
ITS ORIGINAL CONDITION OR BETTER ALL DAMAGE, AS A RESULT OF WORK UNDER THIS CONTRACT DONE
TO EXISTING STRUCTURES, ACCESS ROADS, PAVED AREAS, CURBS, GUTTERS, SOD AREAS, TREES, UTILITY
POLES OR UNDERGROUND LINES AND INCLUDING ALL OBSTRUCTIONS NOT SPECIFICALLY MENTIONED,
SHALL BE REPAIRED AND RESTORED TO A CONDITION ACCEPTABLE TO THE ARCHITECT.
21. CONTRACTOR TO FIR= SEAL ALL GAPS AND PENETRATIONS THROUGH NEW AND /OR EXISTING FIRE RATED
WALL ASSEMBLIES.
G;ENEfRAL CONDITION6.
1. ALL CONSTRUCTION METHODS, MATERIALS, ETC„ SHALL MEET OR EXCEED ANY AND ALL PERTINENT AND
APPLICABLE BUILDING CODES, STANDARDS AND ORDINANCES.
2. PROVIDE A COMPLETE AND OPERATING INSTALLATION INCLUDING ALL NECESSARY ITEMS EVEN THOUGH
SUCH ITEMS ARE NOT INCLUDED IN THE CONSTRUCTION DOCUMENTS.
3. ALL SUBCONTRACTORS SHALL MAKE A PROPER EXAMINATION OF THE PROJECT SITE TO BECOME
FAMILIARIZED WITH THE EXISTING CONDITIONS AND CAREFULLY EXAMINE THE MOST CURRENT AVAILABLE
CONSTRUCTION DOCUMENTS. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY FOR RESOLUTION,
THROUGH THE GENERAL CONTRACTOR OF ANY AMBIGUITY, INCONSISTENCY, OR ERROR WHICH MAY BE
DISCOVERED UPON EXAMINATION OF THE CONSTRUCTION DOCUMENTS OR OF THE SITE OR LOCAL
CONDITIONS. NO EXTRA PAYMENTS SHALL BE APPROVED DUE TO ERRORS OR INCOMPLETE FIELD
CONDITIONS REVIEW, SPECIFICALLY VERIFYING THAT THE NEW EQUIPMENT WILL FIT AS SHOWN ON
DRAWINGS.
4. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND ALL THE SUBCONTRACTORS TO
BID AND BUILD FROM THE MOST UP -TO -DATE SET OF CONSTRUCTION DOCUMENTS AVAILABLE. THE
RELEASE AND USE OF PARTIAL SETS DURING BIDDING AND / OR CONSTRUCTION SHALL NOT RELIEVE THE
CONTRACTOR'S RESPONSIBILITY FOR HIS WORK AND COORDINATION OF THE SAME WITH WORK BY OTHER
TRADES.
5. WRITTEN DIMENSIONS GOVERN. DO NOT SCALE DRAWINGS. IF REQUIRED DIMENSIONS ARE NOT INDICATED
OR SEEM TO BE IN ERROR PROMPTLY NOTIFY THE ARCHITECT FOR RESOLUTION.
6. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND SUBCONTRACTOR TO BE AWARE OF ALL
THE COMMENTS MADE BY THE JURISDICTIONAL BUILDING DEPARTMENT UPON THE OFFICIAL SIGNED AND
SEALED CONSTRUCTION DOCUMENTS JOBSITE FIELD SET AND SHALL INCORPORATE SAME WITHIN THE
SCOPE OF WORK IT SHALL ALSO BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO NOTIFY THE
ARCHITECT OF ANY AND ALL FIELD CHANGES ORDERED BY THE JURISDICTIONAL INSPECTORS AND
OBTAIN WRITTEN APPROVAL OF ANY CHANGES BEFORE PROCEEDING. IT IS THE RESPONSIBILITY of
GENERAL CONTRACTOR TO PROVIDE COST OF REQUIRED CHANGES AT TIME OF APPROVAL REQUEST.
'1, ANY AND ALL SUBSTITUTIONS TO THE CONSTRUCTION DOCUMENTS OR SPECIFICATIONS MUST BE EQUAL TO
THE PERFORMANCE AND APPEARANCE AND MUST BE SUBMITTED TO THE ARCHITECT FOR NECESSARY
REVIEW AND REQUIRED APPROVAL. ALLOW TEN BUSINESS DAYS REVIEW PERIOD FROM ARCHITECT'S
RECEIPT OF SUBSTITUTION SUBMITTAL. ARCHITECT WILL DETERMINE ACCEPTABILITY OF ANY AND ALL
SUBSTITUTIONS. THE SUBCONTRACTOR BEARS ALL ADDITIONAL COSTS OF UNACCEPTABLE SUBSTITUTION
IF USED IN ORIGINAL. BID. THE SUB- CONTRACTOR BEARS ALL ADDITIONAL COSTS FOR REMEDY IF
UNAPPROVED SUBSTITUTION ARE UTILIZED OR DISCOVERED. CONTRACTOR IS RESPONSIBLE TO
PROVIDE ALL TECHNICAL DATA SHOWNG SUBSTITUTION IS EITHER EQUAL OR BETTER THAN SPECIFIED
PRODUCT AT THE TIME OF SUBSTITUTION APPROVAL REQUEST. ALL SUBMITTALS WILL BE RETURNED IF
DATA IS NOT COMPARED TO SPECIFIED PRODUCT.
8. SUBMIT SIX COPIES OF ALL PRODUCT SUBMITTALS REQUESTED BY THE ARCHITECT AND /OR THE
JURISDICTIONAL. AUTHORITY AND / OR THE GENERAL CONTRACTOR REQUIRED FOR CUSTOM FABRICATED
WORK OR AS REQUIRED HEREIN. A MINIMUM OF TEN BUSINESS DAYS SHOULD BE ESTIMATED FOR PROPER
REVIEW of SUBMITTALS.
9. NO RELATED WORK WILL BEGIN WITHOUT RELATED SUBMITTAL.
10. SUBSTITUTIONS WILL NOT BE CONSIDERED DUE TO SUBCONTRACTORS LACK OF PROPER AND TIMELY
ORDERING, SCHEDULING AND /OR PLANNING. ALL LONG LEAD ITEMS SHALL BE IDENTIFIED AND
SCHEDULED PRIOR TO CONSTRUCTION.
Il. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO REVIEW ALL SUBMITTALS PRIOR TO
SUBMITTING SAME TO THE ARCHITECT. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING
ACTUAL EXISTING CONDITIONS RELATED TO SUBMITTALS.
12. THE FOLLOWING PRODUCT SUBMITTALS WILL BE REQUIRED FOR THE RELATED WORK: LIGHT FIXTURES,
PLUMBING FIXTURES, HVAC DEVICES, FIR= ALARM DEVICES, HOLLOW METAL DOORS/FRAMES AND
HARDWARE. FLOOR,WALL 4 CEILWa FINISHER. SHOP DRAWINGS ARE REQUIRED FOR CABINETRY
13, CONTRACTOR SHALL COORDINATE CONSTRUCTION SEQUENCING WITH THE OWNER TO NOT INTERFERE WITH
THE NORMAL OPERATION OF THE BUSINESS. ALL WORK GENERATING NOISE, SMELL AND DUST SHALL BE
COORDINATED WITH THE OWNER
14. ANY POWER INTERUPTIONS SHALL BE SCHEDULED 4 COORDINATED WITH THE OWNER UNDER NO
CIRCUMSTANCES IS ANY WORK TO BE DONE ON THE POWER, SPRINKLER, FIRE ALARM OR HVAC SYSTEMS
WITH OUT COORDINATING WITH, AND OBTAINING APPROVAL FROM THE OWNER
15. REFER TO SITE PLAN FOR TEMPORARY CONSTRUCTION ACCESS LOCATION. ACCESS To LOBBY 4 USE of
EXISTING TOILETS IS STRICTLY PROHIBITED. CONTRACTOR TO PROVIDE TEMPORARY TOILETS.
LOCATION PLAN ry
SCALE: N.Th.
LEGAL DE5CIRIFTION
THE EAST 149 FEET OF THE NORTH 115 FEET OF THE EAST 1/2 OF THE SOUTH-
EAST 114, OF THE SOUTHEAST 1/4, OF THE SOUTHWEST 1/4 OF SECTION 25,
TOWNSHIP 54 SOUTH, RANGE 40 EAST AND THE SOUTH 130 FEET OF THE
NORTH 245 FEET OF THE EAST 1/2 OF THE SOUTHEAST 1/4 OF THE SOUTHEAST
1/4 OF THE SOUTHWEST 1/4 OF SECTION 25, TOWNSHIP 54 SOUTH, RANGE 40
EAST, ALL BEING AND LYING IN DADE COUNTY, FLORIDA.
OUTLINE SPECIFICATIONS
(EQUAL PRODUCTS FROM OTHER MANUFACTURERS WILL BE CONSIDERED)
WOOD FLOORING: REFER TO INTERIOR DESIGN DRAWINGS
SHEET VINYL FLOORING: REFER TO INTERIOR DESIGN DRAWINGS
PORCELAIN TILE FLOORING: REFER TO INTERIOR DESIGN DRAWINGS
WOOD, RUBBER 4 TILE BASE: REFER TO INTERIOR DESIGN DRAWINGS
ACOUSTICAL CEILING SYSTEM: REFER TO INTERIOR DESIGN DRAWINGS
WALL 4 CEILING PAINT: REFER TO INTERIOR DESIGN DRAWINGS
WOOD DOORS: WEYERHAUSER TIMBERLAND CORE DPC -1, 13/4" SOLID CORE
PARTICLE BOARD WITH CHERRY FACE VENEER. PREMIUM GRADE 1 DOORS
PLAIN SLICED OR FLAT CUT. REFER TO INTERIOR DESIGN DRAWINGS FOR STAIN.
CONTRACTOR TO SUBMIT ALTERNATE COST FOR BIRCH DOORS
HOLLOW METAL FRAMES: 16 -GAUGE ALL WELDED MITERED GALVANIZED
STEEL, 3 ADJUSTABLE ANCHORS PER JAMB WITH FLOOR CLIPS. 2" THICK
STANDARD PROFILE FOR 13/4" DOORS. DEPTH OF FRAME SHALL
ACCOMMODATE WALL THICKNESS DIMENSION, 3 RESILIENT RIBBER
SILENCERS ON STRIKE SIDE, BONDERIZED AND PRIME PAINTED WITH ONE
COAT OF BAKED ENAMEL. REFER TO INTERIOR DESIGN DRAWINGS FOR
PAINT COLOR. CONTRACTOR TO SUBMIT ALTERNATE COST FOR 25" WIDE
SATIN ANODIZED ALUMINUM FRAMES
HARDWARE:
B BUTTS: FULL MORTISE BALL BEARING HINGES -4V2" x 4L/2" 1 vz PAIR,
(1.1826D), STANLEY F5516S
C CLOSER: LCN 4040 (US26D)
L LOCKSET: LEVER TYPE, GRADE I, HEAVY -DUTY, (US26D) SCHLAGE
S10D SATURN
WS WALL STOP: ROCKWOOD 40S (US26D)
JURISDICTION
CITY OF SOUTH MIAMI
LAND USE TRANSIT ORIENTED DEVELOPMENT DISTRICT
ZONING DISTRICT
MIXED USE -5 TODD (MU -5)
USE CATEGORY
MEDICAL OFFICE
OCCUPANCY CLASSIFICATION
BUSINESS GROUP "B"
TYPE OF CONSTRUCTION
TYPE IB
FIRE SUPPRESSION SYSTEM
STAND PIPE/FHC
AREA OF REMODELING
3,312 SF.
CLASSIFICATION OF WORK
ALTERATION -LEVEL 2
FOLIO NUMBER
09- 4025 - 000 -0591
NIDEX OF DfRAWING5
INTERIOR DESI
ID -01
FLOOR FINISH PLAN
ID -02
WALL FINISH PLAN
ID -03
INTERIOR ELEVATIONS
ID -04
FINISH LEGEND 4 SCHEDULE
ARCHITECTU
A -10 GENERAL NOTES, PROJECT DATA 4 MASTER SITE PLAN
A -1.1 EXISTING BUILDING PLAN (SEVENTH FLOOR)
A -2.0 PARTIAL DEMOLITION FLOOR 4 CEILING PLAN
A -3.0 PARTIAL SEVENTH FLOOR PLAN
A -ofd PARTIAL SEVENTH FLOOR CEILING PLAN
A -5.0 INTERIOR ELEVATIONS
A -6.0 ENLARGED PLANS 4 GENERAL DETAILS
A -1.0 DOOR 4 FINISH SCHEDULES
_
^ -
-
_
_.......__ ..............._ /
---- - ----- - ---
SW 10TH STREET
........ . ....... ....... . ....... :::: "� CF'E�........ .. l..!•:e%i ...... 5&521 ...............
PLUMBING
GENERAL NOTES, SCHEDULES 4
P -0.1
P -2.1
SANITARY PLAN 4 ISOMETRIC
P -3.1
DOMESTIC WATER PLAN 4 160P
MECHANICAL
M -0.1
GENERAL NOTES, SCHEDULES 4
M -2.1
AIR CONDITIONING PLAN
M -2.1
SCHEDULES 4 DETAILS
MA5T
as
-t
�n
[v
�zs
to
ui
N
VJ
51TE F
SCALE 1 "- 30' -0"
FIRE ALARM SE x EN l H FLOOfR f FLAN
FA -Z.1 GENERAL NOTES, INDEX 4 RISER
FA -2.1 FIRE ALARM PLAN EXISTING SCALE 1/16 " = 1' -0"
RTFSco
ARCHITECTS
1750 PONCE DE LEON BLVD
CORAL GABLES, FL 33134
305.448.4288 305.444.4986
AA0002678
• V
f
1
leA
88AL
OF SUCH HH?
�Lj
KAMM CONSULTING
140! W. IiE11VPOf1ti C9OM MVE
DEEf.D MACK FL 3MQ
mw= FAX m4 94ti~w
��ao
U. I- a. d
o
W LIJ = u
U�o
a �
�w
W
Qw
�
W >
Z =a
�- w 0
z
04
Ocf)
�
ow��
0. ac o
am °�
PROJECT NUMBER
12200
DATE
07/06/12
SHEET
A -1.0
L��