Loading...
12-547-00714 ^1 ' - r-- o­--I(_-�E LI I OFFICE 1m-1 I EX157';�C-. TO M,,iN E6 i J ; I ... .... .... ... .... .... ... .... .... ..i M3 •- - - -. -_ HA L w 'r 9 o 3 €; i j �-�� O I� j j� i •/ \ i o i. Lei {� i i I 0 I ANY NEW HVAC DEVICES SHALL MATCH EXISTING BUILDING STANDARD (TYPICAL) 0 FA M NOTES Ml EXISTING RETURN GRILLE TO BE RELOCATED AS SHOWN. NO DUCTWORK (PLENUM RETURN) M2 EXISTING SUPPLY DIFFUSER TO BE RELOCATED AS SHOWN. CONTRACTOR TO EXTEND EXISTING FLEX DUCT AS REQUIRED TO NEW LOCATION. M3 RELOCATE EXISTING THERMOSTAT AS SHOWN, MOUNT ID 45" AFF. EXTEND CONTROL WIRING AS REQUIRED TO NEW LOCATION FIELD VERIFY EXISTING MAIN SUPPLY DUCT HAS FIRE DAMPER IF NOT, PROVIDE M4 4 INSTALL STYLE "B" DYNAMIC FIRE DAMPER AT 1 -HOUR FIRE RATED PARTITION FIELD VERIFY EXISTING RETURN AIR OPENING HAS A FIRE DAMPER IF NOT, PROVIDE 4 INSTALL STYLE "B" DYNAMIC FIDE DAMPER AT 1 -HOUR FIRE RATED PARTITION M6 NEW 24" X 24" RETURN AIR OPENING A50VE CEILING= W/ FIRE DAMPER PROVIDE 4 INSTALL STYLE "5" DYNAMIC FIRE DAMPER AT 1 -HOUR FIRE RATED PARTITION 8REBALANCE EXISTING CFM'S TO NOTED AMOUNT IN PLAN. FIELD VERIFY S" DIAMETER FLEXIBLE DUCTWORK M8 MECHANICAL CONTRACTOR TO TEST 4 BALANCE SYSTEM AND SUBMIT REPORT TO 8 OWNER ONCE INSTALLATION IS COMPLETE M9 NOT USED ELECTfRIC L NOTES CONNECT TO EXISTING CIRCUIT 1 ROM REMOVED OUTLET, USE 2 +12 THWN CU 4 "12 (GND) EI IN 1/2" CONDUIT. 20 AMP DUPLEX RECEPTACLE (NEMA 5 -20R), MOUNT o 1S" AFF E2 INTERCEPT EXISTING LIGHTING CIRCUIT AND ROUTE /CONNECT NEW LIGHT SWITCH, WIRES AND CONDUIT TO THIS LOCATION. SINGLE POLE, 20 AMP LIGHT SWITCH, MOUNT -0 42" AFF E3 INTERCEPT EXISTING EMERGENCY LIGHTING CIRCUIT IN CORRIDORS AND ROUTE /CONNECT NEW LIGHTS AS INDICATED. 2 X 2 FLOURESCENT STATIC TROFFER (MATCH EXISTING) E4 INTERCEPT EXISTING NORMAL LIGHTING CIRCUIT IN CORRIDORS AND ROUTE /CONNECT NEW LIGHTS AS INDICATED. 2 X 2 FLOURESCENT STATIC TROFFER (MATCH EXISTING) E5 REINSTALL EXISTING SECURITY ALARM KEYPAD IN NEW PARTITION- EXTEND CONTROL WIRING AS REQUIRED FOR THIS LOCATION AND CONNECT TO EXISTING SYSTEM. E6 REINSTALL EXISTING WALL MOUNTED FIRE ALAR'1 DEVICE (HS) IN NEW PARTITION. EXTEND CONTROL WIRING AS REQUIRED FOR THIS LOCATION AND CONNECT TO EXISTING SYSTEM. E-1 REINSTALL EXISTING CEILING MOUNTED SMOKE DETECTOR DEVICE IN NEW CEILING. EXTEND CONTROL WIRING= AS REQUIRED FOR THIS LOCATION AND CONNECT TO EXISTING SYSTEM. E8 RESTORE EXISTING WALL MOUNTED FIRE ALARM DEVICE (PS) IN EXISTING J -BOX. EXTEND CONTROL WIRING AS REQUIRED FOR THIS LOCATION AND CONNECT TO EXISTING SYSTEM. E9 REINSTALL EXISTING EXIT SIGN IN PORTION OF NEW CEILING TILE /GRID. EXISTING LIGHTING CIRCUIT AND WIRING TO REMAIN. ELECTRICAL FLOOiR/CEILING; PLAN (PARTIAL SEVENTH FLOOR) FHVAC MSIQN REQUIRES YES No DUCT SMOKE DETECTOR • FIRE DAMPER(8) • SMOKE DAMPERS) • FIRE RATED ENCLOSURE • FIFE RATED ROOF/FLOOR/CEILING ASSEMBLY • FIRE STOPPING • SMOKE CONTROL • 0 SCALE 1/4 "= 1' -0" ALL EXISTING ELECTRICAL CIRCUITS TO REMAIN. EXTEND CONDUITS AND BRANCH WIRING TO PROPOSED LOCATION INDICATED ON PLAN. NO NEW OR ADDITIONAL CIRCUITS. ;- RIE—SCO ARCHITECTS 1750 PONCE DE LEON BLVD CORAL GABLES, FL 33134 305.448.4288 305.444.4986 AA0002678 N r SEAL ' ALL IDFA4� DFSIONARRANCiFMII1I3 AND �P[[wwlr��e 1CA, OR 0M ESEN- TED BY TH1S DRAWING ARE OWNED BY AND THE PRROPMY OF THIS OF- R611 AND WERE (R M EVOLVED AND DEVELOPED FOR ON AND IN CONNECTION WIIH THE SPE)MUD PROJECT. NONE OF SUCH IDEAS. DE- SIGNS. ARRANCMMEN S OR PLANS SHALL HE USED BY OR MCLOSED TO ANY PERSON FIRM OR CORPORATION FOR ANY PfJRPO6E WHATSOEVER WITHOUT TIIE EXPRESSLY WRrrrEN PERMISSION OF RIE CO ARCHITECTS. PA MARINA + ASSOCIATES m PONCE of UEN a.w, BE 329 CORAL GABLES, FL 3M (305) 4440 FAX (305) 444 -9698 � F- D O °Q °off U �j w a W F- 0 � o� Q w oUW w 0 �- Z OJ N (O O Q can � � ° W o Q =o � REWSAONS m 07-12 -12 PERMIT PROJECT NUMBER 12600 DATE 05/02/12 SHEET ME -1.0 OF 7 e