ANY NEW HVAC DEVICES SHALL
MATCH EXISTING BUILDING
STANDARD (TYPICAL)
0
FA
M NOTES
Ml EXISTING RETURN GRILLE TO BE RELOCATED AS SHOWN. NO DUCTWORK
(PLENUM RETURN)
M2 EXISTING SUPPLY DIFFUSER TO BE RELOCATED AS SHOWN. CONTRACTOR TO
EXTEND EXISTING FLEX DUCT AS REQUIRED TO NEW LOCATION.
M3 RELOCATE EXISTING THERMOSTAT AS SHOWN, MOUNT ID 45" AFF. EXTEND CONTROL
WIRING AS REQUIRED TO NEW LOCATION
FIELD VERIFY EXISTING MAIN SUPPLY DUCT HAS FIRE DAMPER IF NOT, PROVIDE
M4 4 INSTALL STYLE "B" DYNAMIC FIRE DAMPER AT 1 -HOUR FIRE RATED PARTITION
FIELD VERIFY EXISTING RETURN AIR OPENING HAS A FIRE DAMPER IF NOT, PROVIDE
4 INSTALL STYLE "B" DYNAMIC FIDE DAMPER AT 1 -HOUR FIRE RATED PARTITION
M6 NEW 24" X 24" RETURN AIR OPENING A50VE CEILING= W/ FIRE DAMPER PROVIDE
4 INSTALL STYLE "5" DYNAMIC FIRE DAMPER AT 1 -HOUR FIRE RATED PARTITION
8REBALANCE EXISTING CFM'S TO NOTED AMOUNT IN PLAN. FIELD VERIFY S" DIAMETER
FLEXIBLE DUCTWORK
M8 MECHANICAL CONTRACTOR TO TEST 4 BALANCE SYSTEM AND SUBMIT REPORT TO
8
OWNER ONCE INSTALLATION IS COMPLETE
M9 NOT USED
ELECTfRIC L NOTES
CONNECT TO EXISTING CIRCUIT 1 ROM REMOVED OUTLET, USE 2 +12 THWN CU 4 "12 (GND)
EI IN 1/2" CONDUIT. 20 AMP DUPLEX RECEPTACLE (NEMA 5 -20R), MOUNT o 1S" AFF
E2 INTERCEPT EXISTING LIGHTING CIRCUIT AND ROUTE /CONNECT NEW LIGHT SWITCH, WIRES
AND CONDUIT TO THIS LOCATION. SINGLE POLE, 20 AMP LIGHT SWITCH, MOUNT -0 42" AFF
E3 INTERCEPT EXISTING EMERGENCY LIGHTING CIRCUIT IN CORRIDORS AND ROUTE /CONNECT
NEW LIGHTS AS INDICATED. 2 X 2 FLOURESCENT STATIC TROFFER (MATCH EXISTING)
E4 INTERCEPT EXISTING NORMAL LIGHTING CIRCUIT IN CORRIDORS AND ROUTE /CONNECT NEW
LIGHTS AS INDICATED. 2 X 2 FLOURESCENT STATIC TROFFER (MATCH EXISTING)
E5 REINSTALL EXISTING SECURITY ALARM KEYPAD IN NEW PARTITION- EXTEND CONTROL
WIRING AS REQUIRED FOR THIS LOCATION AND CONNECT TO EXISTING SYSTEM.
E6 REINSTALL EXISTING WALL MOUNTED FIRE ALAR'1 DEVICE (HS) IN NEW PARTITION. EXTEND
CONTROL WIRING AS REQUIRED FOR THIS LOCATION AND CONNECT TO EXISTING SYSTEM.
E-1 REINSTALL EXISTING CEILING MOUNTED SMOKE DETECTOR DEVICE IN NEW CEILING. EXTEND
CONTROL WIRING= AS REQUIRED FOR THIS LOCATION AND CONNECT TO EXISTING SYSTEM.
E8 RESTORE EXISTING WALL MOUNTED FIRE ALARM DEVICE (PS) IN EXISTING J -BOX. EXTEND
CONTROL WIRING AS REQUIRED FOR THIS LOCATION AND CONNECT TO EXISTING SYSTEM.
E9 REINSTALL EXISTING EXIT SIGN IN PORTION OF NEW CEILING TILE /GRID. EXISTING LIGHTING
CIRCUIT AND WIRING TO REMAIN.
ELECTRICAL FLOOiR/CEILING; PLAN
(PARTIAL SEVENTH FLOOR)
FHVAC MSIQN REQUIRES
YES
No
DUCT SMOKE DETECTOR
•
FIRE DAMPER(8)
•
SMOKE DAMPERS)
•
FIRE RATED ENCLOSURE
•
FIFE RATED ROOF/FLOOR/CEILING ASSEMBLY
•
FIRE STOPPING
•
SMOKE CONTROL
•
0
SCALE 1/4 "= 1' -0"
ALL EXISTING ELECTRICAL CIRCUITS TO REMAIN. EXTEND
CONDUITS AND BRANCH WIRING TO PROPOSED LOCATION
INDICATED ON PLAN. NO NEW OR ADDITIONAL CIRCUITS.
;- RIE—SCO
ARCHITECTS
1750 PONCE DE LEON BLVD
CORAL GABLES, FL 33134
305.448.4288 305.444.4986
AA0002678
N
r
SEAL '
ALL IDFA4� DFSIONARRANCiFMII1I3
AND �P[[wwlr��e 1CA, OR 0M ESEN-
TED BY TH1S DRAWING ARE OWNED
BY AND THE PRROPMY OF THIS OF-
R611 AND WERE (R M EVOLVED
AND DEVELOPED FOR ON AND
IN CONNECTION WIIH THE SPE)MUD
PROJECT. NONE OF SUCH IDEAS. DE-
SIGNS. ARRANCMMEN S OR PLANS SHALL
HE USED BY OR MCLOSED TO ANY
PERSON FIRM OR CORPORATION FOR
ANY PfJRPO6E WHATSOEVER WITHOUT
TIIE EXPRESSLY WRrrrEN PERMISSION
OF RIE CO ARCHITECTS. PA
MARINA + ASSOCIATES
m PONCE of UEN a.w, BE 329
CORAL GABLES, FL 3M
(305) 4440 FAX (305) 444 -9698
� F- D
O
°Q °off
U
�j w
a W
F-
0 �
o� Q w
oUW
w 0 �- Z
OJ N
(O
O Q can �
�
°
W o
Q =o �
REWSAONS
m 07-12 -12 PERMIT
PROJECT NUMBER
12600
DATE
05/02/12
SHEET
ME -1.0
OF 7
e