Loading...
12-547-001GENEfRAL N 11 1• CONTRACTOR SHALL COMPLY WITH ALL LOCAL, STATE AND FEDERAL BUILDING CODES. PERMIT SHALL BE POSTED ON A VISIBLE LOCATION AT ALL TIMES. 2. CONTRACTOR TO REMOVE, RELOCATE OR RE -ROUTE AS NECESSARY ELECTRICAL, WATER GAS, OR ANY OTHER UTILITY LINES ENCOUNTERED DURING CONSTRUCTIOlIt 3• CONTRACTOR MUST NOTIFY ARCHITECT IMMEDIATELY OF ANY UNEXPECTED OR UNKNOWN CONDITIONSANY DISCREPANCIES WITH THE DRAWINGS AND /OR THE CONTRACT DOCUMENTS, ANY ERRORS AND OMISSIONS ON THE DRAWINGS AND/ OR THE FIELD PRIOR TO PROCEEDING WITH WORK AND /OR SHOP FABRICATION. 4. CONTRACTOR TO OBTAIN WRITTEN APPROVAL FROM OWNER'S REPRESENTATIVE OR ARCHITECT PRIOR TO ANY CHANGES OR DEVIATION FROM CONTRACT DOCUMENTS. 5, DRAWINGS NOT TO BE SCALED. DIMENSIONS TO BE FOLLOWED. 6. ALL DIMENSIONS ARE BASED ON NOMINAL SIZES OF MEMBER AND ARE GIVEN TO THE OUTER FACE OF SUCH MEMBERS, NOT TO FACE OF FINISH MATERIALS, UNLESS OTHERWISE NOTED ON THE DRAWINGS. -1_ THE PLANS AND CALCULATIONS HAVE BEEN PREPARED TO COMPLY WITH THE REQUIREMENTS OF THE 2010 FLORIDA BUILDING CODE. ALL MATERIALS AND WORKMANS41P SHALL CONFORM TO THE REQUIREMENTS or- THE 2010 FLORIDA BUILDING CODE, 2010 FLORIDA FIRE PREVENTION CODE, AND WITH THE REQUIREMENTS OF THE LOCAL BUILDING OFFICIAL. g. PROVIDE AND INSTALL FIRE EXTINGUISHERS PER FIRE MARSHALL'S REQUIREMENTS AND THE 2010 FLORIDA FIRE PREVENTION CODE. g ALL EXTERIOR PRE- MANUFACTURED ITEMS SHALL COMPLY WITH MIAMI DADE COUNTY PRODUCT APPROVAL. 10, ALL EXTERIOR WINDOWS, LOUVERS, HOODS, AND DOORS SHALL COMPLY WITH MIAMI DADE COUNTY PRODUCT APPROVAL, WATER INFILTRATION TEST REQUIREMENTS AND WITH 2010 FLORIDA BUILDING CODE REQUIREMENTS. SUBMIT SHOP DRAWINGS AND PRODUCT APPROVALS FOR ATTACHMENT METHODS 4 DETAILS. 11. ALL WOOD IN CONTACT WITH MASONRY AND / OR CONCRE I ER SHALL BE PRESSURE TREATED LUMBER 12. PROVIDE AND INSTALL WOOD BLOCKING FOR ALL WALL MOUNTED ACCESSORIES AND FINISHED MILLWORK 13, PROVIDE 20 GAUGE METAL STUDS AT ALL WALL- MOUNTED LVATOFJES, URINALS, AND WATER CLOSETS. FLUSH MECHANISMS SHALL BE OPPOSITE OF WALL. 14• REFER TO MECHANICAL, PLUMBING, ELECTRICAL, AND STRUCTURAL DRAWINGS FOR COORDINATION WITH THE ARCHITECTURAL DRAWINGS. ITEMS INDICATED ON THE I ARCHITECTURAL DRAWINGS AND NOT SHOWN ON CONSULTANT DRAWINGS AND CONVERSELY, ITEMS SHOWN ON THE CONSULTANT DRAWINGS AND NOT INDICATED ON THE ARCHITECTURAL DRAWINGS SHALL ALLI BE CONSIDERED PART OF THE WORK UNDER THIS CONTRACT. THE GENERAL CONTRACTOR SHALL NOT BE ENTITLED TO ADDITIONAL FEES FOR FAILING TO PROPERLY COORDINATE THE WORK BETWEEN THE TRADES. 15. TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMICIDES, INCLUDIING SOIL APPLIED PESTICIDES, BAITING SYSTEMS, AND PESTICIDES APPLIED O WOOD, OR OTHER APPROVED METHODS OF TERMITE PROTECTION LABELED FOR USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION AND SHALL COMPLY WITH THE REQUIREMENTS OF THE 2010 FLORIDA BUILDING CODE SECTION 1816. UPON COMPLETION OF THE APPPLICATION OF THE TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: 'THE BUILDING HAS RECIEVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES." 16. CONTRACTOR TO PROVIDE AS GUILTS, WARRANTIES, GUARANTEES, AND OPERATIONAL MANUALS ALONG WITH ALL THE REQUIRED CLOSE -OUT DOCUMENTS UPON SUBSTANTIAL COMPLETION PROVIDE A 5% EXTRA STOCK OF ALL SPECIFIED FINISH ITEMS FOR OWNER USE. 1-1. PROVIDE AND INSTALL FLANGELESS ACCESS PANELS IN GTPSUM BOARD 4 CEMENT PLASTER ASSEMBLIES REQUIRED BY MECHANICAL, ELECTRICAL, AND PLUMBING WORK COORDINATE LOCATION WITH ARCHITECT. 18. CONTRACTOR SHALL NOT SAWCUT, DRILL OR ALTER IN ANY FORM, THE EXISTING STRUCTURE WITHOUT PRIOR APPROVAL FROM THE BUILDING ENGINEER 1S. CONTRACTOR TO REPAIR ALL EXISTING CONCRETE SLABS AFFECTED BY NEW WORK PATCH 4 MATCH ADJACENT SURFACES. 20. CONTRACTOR SHALL REMOVE ALL EXCESS MATERIAL AND SHALL CLEAN UP AND RESTORE THE SITE TO ITS ORIGINAL CONDITION OR BETTER ALL DAMAGE, AS A RESULT OF WORK UNDER THIS CONTRACT DONE TO EXISTING STRUCTURES, ACCESS ROADS, PAVED AREASf CURBS, GUTTERS, SOD AREAS, TREES, UTILITY POLES OR UNDERGROUND LINES AND INCLUDING ALL OBSTRUCTIONS NOT SPECIFICALLY MENTIONED, SHALL BE REPAIRED AND RESTORED TO A CONDITION ACCEPTABLE TO THE ARCHITECT. 21. CONTRACTOR TO FIRE SEAL ALL GAPS AND PENETRATIONS THROUGH NEW AND /OR EXISTING FIRE RATED WALL ASSEMBLIES. G;ENEFOAL GONDITION5. 1. ALL CONSTRUCTION METHODS, MATERIALS, ETC„ SHALL MEET OR EXCEED ANY AND ALL PERTINENT AND APPLICABLE BUILDING CODES, STANDARDS AND ORDINANCES. 2. PROVIDE A COMPLETE AND OPERATING NSTALLATION INCLUDING ALL NECESSARY ITEMS EVEN THOUGH SUCH ITEMS ARIH NOT INCLUDED IN THE CONSTRUCTION DOCUMENTS. 3. ALL SUBCONTRACTORS SHALL MAKE A PROPER EXAMINATION OF THE PROJECT SITE TO BECOME FAMILIARIZED WITH THE EXISTING CONDITIONS AND CAREFULLY EXAMINE THE MOST CURRENT AVAILABLE CONSTRUCTION DOCUMENTS. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY FOR RESOLUTION, THROUGH THE GENERAL CONTRACTOR OF ANY AMBIGUITY, ;INCONSISTENCY, OR ERROR WHICH MAY BE DISCOVERED UPON EXAMINATION OF THE CONSTRUCTION DOCUMENTS OR OF THE SITE OR LOCAL CONDITIONS. NO EXTRA PAYMENTS SHALL BE APPROVED DUE TO ERRORS OR INCOMPLETE FIELD CONDITIONS REVIEW, SPECIFICALLY VERIFYING THAT THE Ni W EQUIPMENT WILL FIT AS SHOWN ON DRAWINGS. 4. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND ALL THE SUBCONTRACTORS TO BID AND BUILD FROM THE MOST UP -TO -DATE SET OF CONSTRUCTION DOCUMENTS AVAILABLE. THE RELEASE AND USE OF PARTIAL SETS DURING BIDDING AND / OR CONSTRUCTION SHALL NOT RELIEVE THE CONTRACTOR'S RESPONSIBILITY FOR HIS WORK AND COORDINATION OF THE SAME WITH WORK BY OTHER TRADES. 5. WRITTEN DIMENSIONS GOVERN. DO NOT SCALE DRAWINGS. IF REQUIRED DIMENSIONS ARE NOT INDICATED OR SEEM TO BE IN ERROR, PROMPTLY NOTIFY THE ARCHITECT FOR RESOLUTION 6. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND SUBCONTRACTOR TO BE AWARE OF ALL THE COMMENTS MADE BY THE JURISDICTIONAL BUILDING DEPARTMENT UPON THE OFFICIAL SIGNED AND SEALED CONSTRUCTION DOCUMENTS JOBSITE FIELD SET AND SHALL INCORPORATE SAME WITHIN THE SCOPE OF WORK IT SHALL ALSO BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO NOTIFY THE ARCHITECT OF ANY AND ALL FIELD CHANGES ORDERED BY THE JURISDICTIONAL INSPECTORS AND OBTAIN WRITTEN APPROVAL OF ANY CHANGES BEFORE PROCEEDING. IT IS THE RESPONSIBILITY OF GENERAL CONTRACTOR TO PROVIDE COST OF REQUIRED CHANGES AT TIME OF APPROVAL REQUEST. ANY AND ALL SUBSTITUTIONS TO THE CONSTRUCTION DOCUMENTS OR SPECIFICATIONS MUST BE EQUAL TO THE PERFORMANCE AND APPEARANCE AND MUST BE SUBMITTED TO THE ARCHITECT FOR NECESSARY REVIEW AND REQUIRED APPROVAL. ALLOW TEN BUSINESS DAYS REVIEW PERIOD FROM ARCHITECT'S RECEIPT OF SUBSTITUTION SUBMITTAL. ARCHITECT WILL DETERMINE ACCEPTABILITY OF ANY AND ALL SUBSTITUTIONS. THE SUBCONTRACTOR BEARS ALL ADDITIONAL COSTS OF UNACCEPTABLE SUBSTITUTION IF USED N ORIGINAL BID. THE SUB- CONTRACTOR BEARS !ALL ADDITIONAL COSTS FOR REMEDY IF UNAPPROVED SUBSTITUTION ARE UTILIZED OR DISCOVERED. CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL TECHNICAL DATA SHOWING SUBSTITUTION IS EITHER EQUAL OR BETTER THAN SPECIFIED PRODUCT AT THE TIME OF SUBSTITUTION APPROVAL REQUEST. ALL SUBMITTALS WILL BE RETURNED IF DATA IS NOT COMPARED TO SPECIFIED PRODUCT. 8. SUBMIT SIX COPIES OF ALL PRODUCT SUBMITTALS REQUESTED BY THE ARCHITECT AND /OR THE JURISDICTIONAL AUTHORITY AND / OR THE GENERAL CONTRACTOR REQUIRED FOR CUSTOM FABRICATED WORK OR AS REQUIRED HEREIN. A MINIMUM OF TEN BUSINESS DAYS SHOULD BE ESTIMATED FOR PROPER REVIEW OF SUBMITTALS. a NO RELATED WORK WILL BEGIN WITHOUT RELATED SUBMITT�4L. 10. SUBSTITUTIONS WILL NOT BE CONSIDERED DUE TO SUBCONTRACTORS LACK OF PROPER AND TIMELY ORDERING, SCHEDULING AND /OR PLANNING. ALL LONG LEAD ITEMS SHALL BE IDENTIFIED AND SCHEDULED PRIOR TO CONSTRUCTION. 11. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO REVIEW ALL SUBMITTALS PRIOR TO SUBMITTING SAME TO THE ARCHITECT. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING ACTUAL EXISTING CONDITIONS RELATED TO SUBMITTALS. 12, THE FOLLOWING PRODUCT SUBMITTALS WILL BE REQUIRED FOR THE RELATED WORK: LIGHT FIXTUIMS, EMERGENCY LIGHTS, EXIT SIGNS, FIRE ALARM DEVICES, HOLLOW METAL DOORS/FRAMES AND HARDWARE. SHOP DRAWINGS ARE REQUIRED FOR NOT APPLICABLE CING WITH THE OWNER TO NOT INTERFERE WITH 13, CONTRACTOR SHALL COORDINATE CONSTRUCTION SEQU THE NORMAL OPERATION OF THE BUSINESS. ALL WORK GENERATING NOISE, SMELL AND DUST SHALL BE COORDINATED WITH THE OWNER 14. ANY POWER INTERUPTIONS SHALL BE SCHEDULED 4 COORDINATED WITH THE OWNER UNDER NO CIRCUMSTANCES IS ANY WORK TO BE DONE ON THE POWER SPRINKLER, FIRE ALARM OR HVAC SYSTEMS WITH OUT COORDINATING WITH, AND OBTAINING APPROVAL FROM THE OWNER 15. REFER TO SITE PLAN FOR TEMPORARY CONSTRUCTION ACCESS LOCATION. ACCESS TO LOBBY 4 USE OF EXISTING TOILETS IS STRICTLY PROHIBITED. CONTRACTOR'TO PROVIDE TEMPORARY TOILETS. ry LOCATION PLAN SCALE: N.T.S. LEGAL DESCRIPTION _._ ........_... .........................._._. __ -- _ - -- _. _.__ ...... . .... _ _ ..........._ _. _ w° : _.._ ................. ................_. - -- - _........... .................- - -.... s SW 10TH STREET .._ ............... __ _ _................ _ _� _._....__. _..._._ _.....____ ..........._. ........______. - -............ W....... _._.. _ .......... _._. _.._ (� ..........._...._ ...............__.._. .............. . t ,t � 3 i w"A a- `'�, -, M LET ►- �; � � i THE EAST 149 FEET OF THE NORTH 115 FEET OF THE EAST 1/2 OF THE SOUTH - w3 LAND USE TRANSIT ORIENTED DEVELOPMENT DISTRICT EAST 114, OF THE SOUTHEAST 1/4, OF THE SOUTHWEST 1/4 OF SECTION 25, € USE CATEGORY TOWNSHIP 54 SOUTH, RANGE 40 EAST AND THE SOUTH 130 FEET OF THE M BUSINESS GROUP "B" NORTH 245 FEET OF THE EAST 1/2 OF THE SOUTHEAST 1/4 OF THE SOUTHEAST TYPE IB x 1/4 OF THE SOUTHWEST 114 OF SECTION 25, TOWNSHIP 54 SOUTH, RANGE 40 AREA OF REMODELING 64-1 SF. EAST, ALL BEING AND LYING IN DADE COUNTY, FLORIDA, ALTERATION -LEVEL 2 FOLIO NUMBER OS- 4025 -000 -0591 EXISTING SEVEN --TORY ; ; ;ST_ P Pi D i D ICE ul_, DlNs OUTLINE 5FECIFIGATIONS I _. _..._ ..._ 3 ._ ...... (EQUAL PRODUCTS FROM OTHER MANUFACTURERS WILL BE CONSIDERED) CARPET: COMMERCIAL GRADE DIRECT GLUE DOWN CARPET. KARASTAN- "HYPNOTIZING" DC15.1, COLOR 88406 WINK (MATCH EXISTING) VINYL TILE: 12" x 12" x 1 /8" VINYL TILE BY "ARMSTRONG" IMPERIAL TEXTURE STANDARD EXCELON, COLOR TO MATCH EXISTING VINYL BASE: 4" HIGH COVE BASE BY ARMSTRONG", 080 STANDARD, COLOR TO MATCH EXISTING CEILING: 24 x 24 x 5/8 ANGLED TEGULAR BY ARMSTRONG, MATCH EXISTING CEILING TILE AND SUSPENSION GRID PAINT: 1 PRIMER COAT 4 2 COATS OF LATEX FOR PARTITIONS "SHERWIN WILLIAMS" COLOR- SW6141 "SOFTER TAN ". 2 -COATS OF SEMI -GLOSS ALKYD ENAMEL FOR HOLLOW METAL FRAMES, COLOR TO MATCH EXISTING WOOD DOORS: WEYERHAUSER TIMBERLAND CORE DPC -1, 134" SOLID CORE PARTICLE BOARD WITH BIRCH FACE VENEER. PREMIUM GRADE i DOORS PLAIN SLICED OR FLAT CUT. (STAIN TO MATCH EXISTING) HOLLOW METAL FRAMES: I6 -GAUGE ALL WELDED MITERED GALVANIZED STEEL, 3 ADJUSTABLE ANCHORS PER JAMB WITH FLOOR CLIPS. 2" THICK STANDARD PROFILE FOR 13/4" DOORS. DEPTH OF FRAME SHALL ACCOMMODATE WALL THICKNESS DIMENSION, 3 RESILIENT RUBBER SILENCERS ON STRIKE SIDE, BONDERIZED AND PRIME PAINTED WITH ONE COAT OF BAKED ENAMEL. (MATCH EXISTING DOOR FRAME COLOR) HARDWARE: (MATCH EXISTING) B BUTTS: FULL MORTISE BALL BEARING HINGES -41/2" x 41/1" 1 1/2 PAIR, (1.1526D), STANLEY F55168 C CLOSER: LCN 4040 (US26D) L LOCKSET: LEVER TYPE, GRADE 1, HEAVY -DUTY, (US26D) SCHLAGE SIOD SATURN WS WALL STOP: ROCKWOOD 409 (11826D) JURISDICTION CITY OF SOUTH MIAMI LAND USE TRANSIT ORIENTED DEVELOPMENT DISTRICT ZONING DISTRICT MIXED USE -5 TODD (MU -5) USE CATEGORY MEDICAL OFFICE OCCUPANCY CLASSIFICATION BUSINESS GROUP "B" TYPE OF CONSTRUCTION TYPE IB FIRE SUPPRESSION SYSTEM STAND PIPE/FHC AREA OF REMODELING 64-1 SF. CLASSIFICATION OF WORK ALTERATION -LEVEL 2 FOLIO NUMBER OS- 4025 -000 -0591 INDEX OF DF...,AWING5 ARCHITECTU A -1.0 GENERAL NOTES, PROJECT DATA 4 MASTER SITE PLAN A -1.1 EXISTING BUILDING PLAN (SEVENTH FLOOR) A -2.0 ENLARGED DEMOLITION FLOOR 4 CEILING PLAN A -30 PARTIAL SEVENTH FLOOR PLAN A -old PARTIAL SEVENTH FLOOR CEILING PLAN A -5.0 DETAIL, DOOR 4 FINISH SCHEDULES ME -1.0 MECHANICAL/ELECTRICAL FLOOR 4 CEILING PLANS ; � 1 > i 3 1€ ;I � 1 1 jE 3 it II 1' z Lu .1 CV v! MASTER SITE PLAN SCALE I "= 30' -0" 3Uil_[,liN'G DEPT. STZUC ORAL ccuf. 0 -' !dIrPOVED BY. -_ _ , PROJECT NUMBER 12600 RIESCO ARCHITECTS 1750 PONCE DE LEON BLVD CORAL GABLES, FL_ 33134 305.448.4288 305.444.4986 AA0002678 0. � 1 . M .; � 1 •r. �~ �_�1 . MU L �K 1. 1 •JI •,: J +: J.Y J� 7• 11: 1 f •• y• ' J' la \Y • MARNA + ASSOCIATES 7V PONCE DE LEON BLVD, ME 351 CORAL GAS, FL 33134 (305) 444 0 FAX (305) 4*M � � D O J 0 oQo� �W�" a W Cc o � IrQw oUW U = Q W � Z O -J c*j Cc ° LL_ o Q =o � REVISKM 1 3 i i I EXISTING SCALE I /16 "= V -0" DATE 05/02/12 SHEET A -1.0 OF 7 ; 3 ; 1 � � ILi I EXISTING SEVEN --TORY ; ; ;ST_ P Pi D i D ICE ul_, DlNs �..._. _......_ _ _. _..._ ..._ 3 ._ ...... 3 1€ ;I � 1 1 jE 3 it II 1' z Lu .1 CV v! MASTER SITE PLAN SCALE I "= 30' -0" 3Uil_[,liN'G DEPT. STZUC ORAL ccuf. 0 -' !dIrPOVED BY. -_ _ , PROJECT NUMBER 12600 RIESCO ARCHITECTS 1750 PONCE DE LEON BLVD CORAL GABLES, FL_ 33134 305.448.4288 305.444.4986 AA0002678 0. � 1 . M .; � 1 •r. �~ �_�1 . MU L �K 1. 1 •JI •,: J +: J.Y J� 7• 11: 1 f •• y• ' J' la \Y • MARNA + ASSOCIATES 7V PONCE DE LEON BLVD, ME 351 CORAL GAS, FL 33134 (305) 444 0 FAX (305) 4*M � � D O J 0 oQo� �W�" a W Cc o � IrQw oUW U = Q W � Z O -J c*j Cc ° LL_ o Q =o � REVISKM 1 3 i i I EXISTING SCALE I /16 "= V -0" DATE 05/02/12 SHEET A -1.0 OF 7