12-32R-008FIXTURE CONNECTION SCHEDULE
ITEM
WASTE &
SOIL (AS PER
TABLE 709.1
WATER (AS PER TABLE 6045)
COLD
HOT
WATER CLOSET
3'
1/2'
- -
LAVATORY
1-V4'
1/2"
- -
SINK
NOTE ALL TRAPS SHALL BE CONSISTENT W/ FIXTURE OUTLET SIZE
NOTE ALL FIXTURE SHALL COMPLY W/ F.B.C, TABLE 60"
WATER PIPING SIZE
Qi
v2'0 CW/HW
Q
v2-0 CW
03
3/4.0 CW - 1/2'0 HW
®
3 /4'e CW/HW
05
1/2-0 HW
6
3/4'0 CW
E E ALL REDUCED FLOW PLUMBING FIXTURES AS PER
ADE COUNTY OPC4NANC E CODE CHANGE
NNE
CONSTRUCTION NOTES
- ALL SANITARY PIPE 2 V210 OR SMALLER
SHALL RUN O V4' SLOPE PER LFT.
3' AND LARGER O V8' SLOPE PER LFT.
- ALL TUB AND SHOWER SHALL BE
ANTI- SCALDING VALVE O 110 DEGREE (TYP)
- ALL PIPES TO DISCHARGE
MIN. 12' FROM STRUCTURE
- ALL PLUMBING WATER DEVICE
PROVIDE SHUT -OFF VALVE
- NO SPLICE ALLOWED UNDER SLAB
HAMMER ARRESTOR,
- HAMMER ARRESTOR M SHALL BE JOSAM
ABSORBOTAON TYPE Na 75001 OR
APPROVED EQUAL.
- A WATER HA SHALL BE INSTALLED WHERE
OUIgC-0LOSING VALVES ARE UTILIZED,
UNLESS OTHERWISE APPROVED.
- SHALL BE LOCATED WITM AN EFFECTIVE
RANGE OF THE QUICK-CLOSING VALVE
1
SOM
yr cw
1�
SK
EXISTING
V2' CW SOV EXISTING 31 4' WATER LINE
CONNECT NEW WATER LINES
AS SHOWN FOR NEW FUTURES.
C U
1/2' CW 1
0
11WC
WATER ISOMETRIC
NTS
ADJUSTABLE COLLAR
EXISTING 3' DRAIN LINE CONNECT
NEW 3' SANITARY TO EXIST.
STAINLESS STEEL COVER
SCREWED TO THREADED
GO PLUG
FACE OF WALL
FLOOR WALL
TYPICAL CLEANOUT DETAILS
NT,S
NOTE
NO SPLICE ALLOWED UNDER SLAB
NOTE
ALL PLUMBING WATER DEVICE
PROVIDE SHUT -OFF VALVE
LEGEND
ON - OVER HEAD
US - UNDER SLAB
LLG - UNDER GROUND
AAV - AIR ADMITTANCE VALVE
RW. - RUN IN WALL
NOTE
ALL SANITARY PIPE 2 V2-0 OR SMALLER
SHALL RUN O V4' SLOPE PER LFT.
3' AND LARGER O V8' SLOPE PER LFT.
NOTE:
ALL VTR SHALL BE OFF SET
A MIN, OF 4W FROM FIRE
SEPARATION WALL
NOTE
ALL PIPES TO DISCHARGE
MIN. 12 - FROM STRUCTURE
FIELD COORDINATION NOTE
EVERY CONTRACTOR SHALL COORDINATE IN FIELD W/ OTHER TRADES
PRIOR START OF CONSTRUCTION FOR THE STRUCTURAL BEAM SLAB,
TRUSSES, ARC FrECTURAL DETAILING AS PRE -FAB FORMS, REVELING
CEILINGS, ARCH WITH THE LOCATION OF CEILING OR WALL GRILLES,
DUCT WORKS, RETURN GRILLES, LIGHTING FIXTURES SWITCHES
RECEPTACLES OR ANY OTHER DEVICES. AND TO NOTIFY ARCHITECT/
ENGINEERS IF ANY CONFLICT OCCUR PRIOR ITS INSTALLATION- NO
ADDITIONAL COST TO OWNER CAN BE APPLIED.
I
I
I
cV
�I
I
I
iZi LAV
CO
WC
t
FD
TOTAL 7 DELL
SANITARY ISOMETRIC
NTS
0191;
SLEEVE & SEAL
SEAL THRU SLAB
MIN. 3'
WASTE
PIPING
COLD WATER SUPPLY
FROM NEAREST
LAVATORY OR SINK
TRAP PRIMER VALVE
FLOOR DRAIN W/
ADJUSTABLE
STRAINER
TRAP PRIMER
CONNECTION
P -TRAP
FLOOR DRAIN DETAIL W/ TRAP PRIMER
N.T.S.
Gras s i fl ep,
UML
S.Ys t eQa
WL 1113
1 or 2 Hour Fire Rated Through
Penetration Firestop for Single
Metallic Pipe through
Gypsum Walls using
TREMstop IA.
F- Rating = 1 and 2 Hr.
T- Rating = 0 Hr.
M00(03
3735 Green Rd.
Beachwood, OH, 44122
Drawing not to scale
1QPre -Rated Gypsum Wallboard/Stud Wall Assembly
Metallic Pipe:
A) Steel Pipe - 4" diam. (or smaller) Sch. 40 (or heavier) steel pipe.
B) Iron Pipe - 4" diam. (or smaller) cast or ductile iron pipe.
C) Conduit - 4" diam. (or smaller) EMT or rigid steel conduit.
D) Copper Tubing - 4" diam. (or smaller) Type L (or heavier) copper tubing.
E) Copper Pipe - 4" diam. (or smaller) Regular (or heavier) copper pipe.
The annular space shall be min. 1/4" to max. 5/8" within the firestop system.
t 3)TREMstop 1A - Min. 1/2" thickness of sealant applied within opening. Additional sealant
to be installed such that a min. 1/4" crown is formed around the
penetrating item.
Project: The products used in the above assembly The above described assembly and
been tested in accordance with the following: products have been tested and are
based on both past and anticipated
Location: ASTM E814 (UL 1479) Standard Test Method performance criteria. Tremeo shall
for Through Penetration Firestopping. not be liable for any damages, direct
Installer. or consequential, resulting from use
Date: 6/30/97 1 Drawing: TW -1113 ofthis material or design. Tremco
"I only be responsible for replacing
Signature: Approved by: J. Pitcole material found to be defective.
MEC JOB #10151
h IRE
Maqueira Engineering
Consultants, Inc.
CA #9088
Rolando Maqueira, PE
PE #55482
7487 SW 50th terrace
Miami, Florida 33155
Tel: 305.669.5595
Fax: 305.669.5596
�I J
W
0 z
�N�W
I �
111111
z �
�wNW
0
� m
M CC>7
LU
z
z
� LL
x
a
uuf� J
1� N
0
N_0 0
0
0
LLI
LL �
aw
N
� U)
'z N
�Z
g
. 1 a
WN
U
a
W °
� J
� LL
Vow
�Qm�
S
�.
--------------------------- s
i
Ld
Q LL
N LL!
Q O
O Q
0—
0
r
LLU
O
z
Q
Z
LU
Q
SHEET:
F =-- 2
OWd. &a
CHECK. 1 M $
I.OATE Oe.113.201?
R. 1310
R. CONS.
Cot" IM. 1m4m -Zm3
y
s
Ix
i
e
t