12-32R-003■o TYP I GAL BRAG I N6 WIRE SCALE: 3" = 1' -0" 3-5/a.,20 G FULL LENGTH STUDS TO STEEL RUNNER SECURELY ATTACHED TO STRIIIICTURE ABOVE STANDARD 'T' HANGER WIRES SECURED' ATTACHED TO STRUCTURE ACOUSTICAL CEILING WHERE REQUIRED_ SEE REFLECTED CEILING PLAN # FINISH SCHEDULE, 5/8' GYPSUM BOARD SEE FINISH SCHEDULE 3 5/8' - 20 GA. STEEL STUDS Q 24' O .C. WITH FIRESTOPS 0 8' -0' VERT_ (BEYOND) 3-5/5',20 GA. STEEL TRACK. GEILINC I$ PARTITION DEVIL SCALE: 3" = 1' -0" z 11J Q W lL w N N w v 20 GAUGE METAL GENERAL SOFFIT FRAMING NOTES: 1. ALL METAL STUDS SHALL BE 3 -5/8' 20 GAUGE 6 24' O.C. UNLESS OTHERWISE NOTED, TYP. 2_ ALL FIRE RATED WALLS SEPARATION AND /OR PENETRATIONS SHALL BE SEALED WITH AN UL DESCRIPTION LABELED FIRE RATED MATERIAL. G.C. SHALL BE RESPONSIBLE FOR PROVIDING ALL SHOP STRUCTU DRAWINGS AND /OR CUT SHEETS FOR ALL UL LABELED FIRE RATED MATERIALS NOT SPECIFIED IN AND MODEL CONSTRUCTION DOCUMENTS AND /OR SPECIFICATIONS, TYP_ 3. ALL JOINTS/DEPRE55ION5 OF THE GYPSUM WALL BOARD SHALL SE TAPED, APPLIED THREE COATS STANDARD OF SPACKLE, AND SANDED TO A SMOOTH FINISH READY TO RECEIVE FINISH AS PER SCHEDULE, ER WALLS AND CEILINGS ARE TO BE FREE OF ANY UNEVENESS AT JOINTS AND CORNERS_ ALL OUTSIDE EMER3ENCY LIGHT FIXTURE CORNERS SHALL HAVE METAL BEAD AND SPACKLE. 4. REFER TO FINISH SCHEDULE FOR FINISHES, TYP. 5, CONTRACTOR SHALL FIELD VERIFY THAT SLABS t FLOORS ARE NOT PRE -CAST, EXIT LIGHT FIXTURE P05T- TENSIONED, OR PRE - STRESSED PRIOR TO SHOOTING= INTO SLAB, TYP_ 6_ G.C. SHALL SECURELY ATTACH METAL STUD FRAMING TO STRUCTURE ABOVE AND SHALL PROVIDE SEE ELECTRICAL DRAWINGS BRACING a 48' O.C. ALTERNATING DIRECTIONS UNLESS OTHERWISE SPECIFIED, TYP. -1. GL. SHALL COORDINATE EXACT SIZE AND LOCATION OF LIGHT FIXTURES W/ MANUFACTURER AND ILE AND WHITE METAL GRID METAL FRAMING IN FIELD FOR PROPER INSTALLATION. ® 2' -0' x 2' -0' SUPPLY SEE MECHANICAL DRAWINGS GENERAL ACOUSTICAL CE I L INCA NOTES: 1, SUSPENDED GRID HANGER WIRES: 2. PROVIDE 12 GA HANGER WIRES AT A MAX SPACING OF 4' -0' X 4' -0' ALONG MAIN RUNNERS_ DIFFUSER DO NOT SPLICE HANGER WIRES_ 3_ PROVIDE 12 GA HANGER WIRES AT THE ENDS OF ALL MAIN AND CROSS RUNNERS WITHIN 8' SEE MECHANICAL DRAWINGS FROM THE SUPPORT OR WITHIN 1/4 OF THE LENGTH OF THE END TEE, WHICHEVER 15 LEAST, FOR AIR GRILLE THE PERIMETER OF THE CEILING AREA 4, PROVIDE TRAPEZE OR OTHER SUPPLEMENTARY SUPPORT MEMBERS AT OBSTRUCTIONS TO SEE MECHANICAL DRAWINGS HANGER SPACING. PROVIDE ADDITIONAL HANGERS, OR BRACES AS REQUIRED AT ALL GRILLE CEILING BREAKS, SOFFITS OR DISCONTINUOUS AREAS_ HANGER WIRES THAT ARE MORE THAN 1 I� IN 6 OUT OF PLUMB SHALL HAVE COUNTER- SLOPING WIRES. 5, PROVIDE SETS OF FOUR SPLAYED 12 GA BRACING WIRES ORIENTED 90 DEGREES FROM EACH OTHER AT NOT MORE THAN 12 FEET BY 12 FEET ON CENTER. PROVIDE BRACING WIRES AT LOCATIONS NOT MORE THAN 1/2 OF THE ABOVE SPACINGS FROM EACH PERIMETER WALL AND AT THE EDGE OF VERTICAL CEILING OFFSETS. THE SLOPE OF THESE WIRES SHOULD NOT EXCEED 45 DEGREES FROM THE PLANE OF THE CEILING AND SHOULD BE TAUT WITHOUT Q CAUSING THE CEILING TO LIFT_ 6. FASTEN HANGER WIRES WITH NOT LESS THAN 4 TIGHT TURNS_ FASTEN BRACING SPLAY WIRES �OUWJ WITH 4 TIGHT TURNS. MAKE ALL TIGHT TURNS WITHIN A DISTANCE OF 1 -1/2 INCHES. HANGER OR N U1 J � o W BRACING WIRE ANCHORS TO THE STRUCTURE SHOULD BE INSTALLED IN SUCH A MANNER THAT I ❑ THE DIRECTION OF THE WIRE ALIGNS AS CLOSELY AS POSSIBLE WITH THE DIRECTION OF THE ❑� Z LL FORCES ACTING ON THE WIRE. 7_ SEPARATE ALL CEILING HANGING AND BRACING WIRES AT LEAST 6 INCHES FROM ALL m UNBRACED DUCTS, PIPES, CONDUIT, ETC. IT 15 ACCEPTABLE TO ATTACH LIGHTWEIGHT ITEMS, SUCH AS SINGLE ELECTRICAL CONDUIT NOT EXCEEDING 3/4' NOMINAL DIAMETER WITH A FASTENER APPROVED BY THE STRUCTURAL ENGINEER AND ORS, 8. CEILING GRID MEMBERS MAY BE ATTACHED TO NOT MORE THAN 2 ADJACENT WALLS_ CEILING GRID MEMBERS SHOULD BE AT LEAST 1/2 INCH FREE OF OTHER WALLS_ IF WALLS RUN DIAGONALLY TO CEILING GRID SYSTEM RUNNERS, ONE END OF MAIN AND CROSS RUNNERS SHOULD BE FREE AND A MINIMUM OF 1/2', CLEAR OF WALL- S_ LAY -1N CEILING ASSEMBLIES IN EXITWAYS SHALL BE INSTALLED WITH A MAIN RUNNER OR CROSS RUNNER SURROUNDING ALL SIDES OF EACH PIECE OF TILE BOARD OR PANEL AND z EACH LIGHT FIXTURE OR GRILL SPLICES AND INTERSECTIONS OF SUCH RUNNERS SHALL BE ATTACHED WITH THROUGH CONNECTORS SUCH AS POP RIVETS, SCREWS, PINS, PLATES WITH BENT TABS OR BY OTHER APPROVED CONNECTORS. EXPANSION JOINTS SHALL BE 0 PROVIDED IN THE CEILING AT INTERSECTIONS OF CORRIDORS AND AT JUNCTIONS OF 0 CORRIDORS AND LOBBIES OR OTHER SIMILAR AREAS_ 10. ATTACH ALL LIGHT FIXTURES TO THE CEILING GRID RUNNERS TO RESIST A HORIZONTAL FORCE EQUAL TO THE WEIGHT OF THE FIXTURES. 11. FLUSH OR RECESSED LIGHT FIXTURES AND AIR TERMINALS OR SERVICES WEIGHING LESS THAN 56 POUNDS MAY BE SUPPORTED DIRECTLY ON THE RUNNERS OF HEAVY DUTY GRID SYSTEM LLI BUT, IN ADDITION, THEY MUST HAVE A MINIMUM OF TWO SLACK SAFETY WIRES ATTACHED TO W ul THE FIXTURE AT DIAGONAL CORNERS AND ANCHORED TO THE STRUCTURE ABOVE_ ALL 4 FT_ UL LU X 4 FT. LIGHT FIXTURES MUST HAVE SLACK SAFETY WIRE AT EACH CORNER. ALL FLUSH OR � N RECESSED LIGHT FIXTURES AND AIR TERMINALS OR SERVICES WEIGHING 56 POUNDS OR MORE MUST BE INDEPENDENTLY SUPPORTED BY NOT LESS THAN 4 TAUT WIRES, EACH C.Y / t1LS ATTACHED TO THE FIXTURE AND TO THE STRUCTURE ABOVE REGARDLESS OF THE TYPE OF ANGEL C. sAMI II, AIA CEILING GRID SYSTEM USED_ THE 4 TAUT WIRES INCLUDING THEIR ATTACHMENT TO THE 08.102011 STRUCTURE ABOVE MUST BE CAPABLE OF SUPPORTING 4 TIMES THE WEIGHT OF THE UNIT. - R CONS TYP I GAL BRAG I N6 WIRE SCALE: 3" = 1' -0" 3-5/a.,20 G FULL LENGTH STUDS TO STEEL RUNNER SECURELY ATTACHED TO STRIIIICTURE ABOVE STANDARD 'T' HANGER WIRES SECURED' ATTACHED TO STRUCTURE ACOUSTICAL CEILING WHERE REQUIRED_ SEE REFLECTED CEILING PLAN # FINISH SCHEDULE, 5/8' GYPSUM BOARD SEE FINISH SCHEDULE 3 5/8' - 20 GA. STEEL STUDS Q 24' O .C. WITH FIRESTOPS 0 8' -0' VERT_ (BEYOND) 3-5/5',20 GA. STEEL TRACK. GEILINC I$ PARTITION DEVIL SCALE: 3" = 1' -0" z 11J Q W lL w N N w v Q �V � a • :v 4 ING EXIST_ 3 %8' 20 GAUGE METAL AT 24' O.C. CURELY ATTA STRUCTURE ITH 34. TAP CON OTC iv EXIST_ 3 V 20 GAUGE METAL sTuo REFLECTED CEILING LEGEND= SYMBOL DESCRIPTION MANUFACTURER STRUCTU ABOVE WITH %' AND MODEL <F,,r,.,<:: •;' 2' -0' x 4' -0' SEE ELECTRICAL DRAWINGS STANDARD FLOURE5CENT FIXTURE ER WIRES SECURELY EMER3ENCY LIGHT FIXTURE SEE ELECTRICAL DRAWINGS i EMERGENCY LIGHT AND SEE ELECTRICAL DRAWINGS EXIT LIGHT FIXTURE ® EXIT LIGHT FIXTURE SEE ELECTRICAL DRAWINGS X2 ACOUSTICAL CEILING ILE AND WHITE METAL GRID SEE FINISH SCHEDULE ® 2' -0' x 2' -0' SUPPLY SEE MECHANICAL DRAWINGS AIR DIFFUSER ® 1' -0' x 1' -0' SUPPLY AIR SEE MECHANICAL DRAWINGS DIFFUSER n n 2' -0' x 2' -0' RETURN SEE MECHANICAL DRAWINGS AIR GRILLE i' -0' x 1' -0' RETURN AIR SEE MECHANICAL DRAWINGS GRILLE I� EXHAUST FAN SEE MECHANICAL DRAWINGS Q �V � a • :v 4 ING EXIST_ 3 %8' 20 GAUGE METAL AT 24' O.C. CURELY ATTA STRUCTURE ITH 34. TAP CON OTC iv EXIST_ 3 V 20 GAUGE METAL sTuo BRACES T 48' O.C. STAGGERED AND SECURELY ATTACHED TO STRUCTU ABOVE WITH %' TAP CONS a EACH END, STANDARD 12 GAUGE Ha ER WIRES SECURELY ATTACHE t0 i STRUCTURE A VE z �4 d ACOUSTICAL CEILINGS_ sEE CEILING PLAN t FINISH SCHEDULE. V GYPSUM BOARD. 6'(MINJ ABOVE ACOUSTICAL CEILING CORNER BEAD (TYP) 3 V 20 GAUGE RUNNER SEXISTIN5 GEIL.ING DETAIL- SCALE: I" = 1' -0" I f u =s• A•._) u I H tviIArifiI BUILDING DEPT. STRUCTURAL SECTION IF + 8' -11' BOTT. OF GYP_ BOARD SOFFIT _ + W- 5 -1/2' TOP OF EXISTING STOREFRONT. + 8' -0' BOTTOM OF ACOUSTICAL CEILING a GYPSUM BOARD HEADER _ C R m G C (k I�L S� q z D i= It a N G' E rr C O u.i N iu m uj O . -ter A • > .A G Lu 4. _L tt I` 4 Q 9 � � 0 i O d) n n U- LL aaa m Q J I- W �OUWJ ❑ O Q LL Z W N U1 J � o W �a I� 0 I ❑ �0 ❑Q W ❑� Z LL WNW I 0 m M V M � J W .. TWA z N O ci� a �0 W Z o a- N E LLI W n= Z a v Z Q z 0 � 0 W mU W o I_ `v ° it LL LLI V U w LL O J Q m o O 1.0 Ul U LLI ® W ul L UL LU J � N SHEET: D WN_ C.Y / t1LS CHECK- ANGEL C. sAMI II, AIA 1. DATE 08.102011 R BID - R CONS - COMM_ 1040 -205 N 0) Lu U a 0 U Wu O u ti ti 1 J 5' •