12-32R-001,ill i i ----- A---------- - - - - -- TENANT OCCUPANCY FIRE SEPARATION NOTE: IT SHALL BE THE RESPONSA51LITY OF THE LEASING AGENT TO ADVISE ARCHITECT OF THE PROPOSED TENANT'S USE(S) BASED ON CHAPTER 3, 'USE E OCCUPANCY CLASSIFICATION' OF THE LATEST EDITION OF THE FLORIDA BUILDING CODE TO DETERMINE IF THE SEPARATION PARTITIONS BETWEEN TENANTS ARE TO BE ONE (1) HOUR, TWO (2) HOURS OR MORE, PRIOR TO THE COMPLETION OF THE A/E DRAWINGS PER THE LANDLORD'S WORK SCOPE KAY PLAN /WORK AREA SCALE: 1432° = 1' -0'• NORTH I j.m !/ !1 I \ I �._ / \ I 1 5GALE: 1/4" = 1' -0'• WORK SCOPE: INTERIOR REMODELING OF EXISTING MEDICAL OFFICE. -'DRAW ROOMS' SHALL BE FOR COLLECTION OF BLOOD d URINE SAMPLES ONLY. - 'PROCESSING ROOM' SHALL BE FOR PLACING t PACKAGING SPECIMENS t REQUISITIONS IN A BAG TO BE SENT TO MAIN LAB FOR TESTING- -NO TESTING TO BE DONE ON SITE. KEY LEGEND- • *ALL SYMBOLS MAY NOT BE APPLICABLEis• SYMBOL DESCRIPTION PLUMBING FIXTURE ACCESSORY_ SEE SHEET A0.00 FOR FIXTURE ACCESSORY SCHEDULE WALL /PARTITION SEE SHEET A5.11 FOR WALL / PARTITION SCHEDULE AND UL LABELS O DOOR SEE SHEET A6.11 FOR DOOR SCHEDULE O WINDOW SEE SHEET A0 -00 FOR WINDOW AND STOREFRONT SCHEDULE C-4 FINISH MATERIAL SEE SHEET A6.13 FOR FINISH MATERIAL SCHEDULE O KEY NOTE_ SEE SAME SHEET FOR KEY LEGEND, TYP. FOR ALL. TABLE 1004.1.1 FLORIDA BUILDING CODE, BUILDING, 2001 MINIMUM OCCUPANT LOAD OCCUPANCY TYPE AREA / OCCUPANCY LOAD FACTOR TOTAL LOAD BUSINESS - 100 SQ FT. / PERSON 1,545 Sa FT, 16 OCCUPANTS PROFESSIONAL SERVICES LAVATORIES SHOWERS FOUNTAINS TABLE P403.1 FLORIDA BUILDING CODE, PLUMBING, 2001 MINIMUM NUM ER OF PL.UM5ING FACILITIES OCCUPANCY WATER CLOSETS LAVATORIES BATHTUBS/ DRINKING OTHER MALE FEMALE 1 LAVATORIES SHOWERS FOUNTAINS BATHTUBS / SHOWERS BUSINESS 1/25 FIRST 50, 1140 FIRST 80, _ 1/100 - - THEN 1/50 FOR THEN 1180 FOR REMAINDER REMAINDER 24 Q nIDe EXCEEDING 50 1EXCEEDING 801 1 AS PER F.B.0 PLUMBING 4032 EXCEPTION 3: SEPARATE FACILITIES SHALL NOT BE REQUIRED IN BUSINESS AND MERCANTILE OCCUPANCIES WITH A TOTAL FLOOR AREA OF 3,000 SQUARE FEET OR LESS_ SEE TABLE 1004.1.1 THIS SHEET FOR OCCUPANT LOAD (EACH) REQUIRED PROVIDED MALE WATER CLOSETS UNISEX 1 1 FEMALE WATER CLOSETS 1 1 LAVATORIES 1 1 BATHTUBS / SHOWERS - - DRINKING FOUNTAINS (PROVIDED OUTSIDE THE SPACE) 1 1 OTHER - - PROJECT DATA CONSTRUCTION TYPE: •z'•' Lo OCCUPANCY TYPE-^ ,CxROUP B (BUSINESS) y ,, TOTAL SPACE AREA: ` IL. 11 `= X1,545 SF. SLAB NOTE: CONTRACTOR SHALL CORE DRILL EXISTING CONCRETE SLAB FOR NEW # RELOCATED PLUMBING WOR1G TO BE DONE AND REMOVE DEBRIS FROM SITE. USE EXTREME CARE TO NOT CUT OR DAMAGE ANY STEEL RE -BARS DURING CORE PROCEDURE. SHOULD ANY CRAKING, SETTLEMENT OR MOVEMENT OCCUR STOP ALL WOW IMMEDIATELY- NOTIFY BLDG MANAGER FOR POSSIBLE EVACUATION OF ALL PERSONS DIRECTLY ABOVE WORK AREA AND CONTACT ARCHITECT. SHORE WORK AREA IMMEDIATELY W/ 4x4 POSTS 24' O/C BOTH WAYS W/ FLAT 2X PLATES TOP 4 BOTTOM. FURNITURE NOTE: • A MINIMUM EGRESS SPACE OF 44 INCHES SHALL BE PROVIDED BETWEEN OFFICE SYSTEM FURNITURE, TYP. • CONTRACTOR TO VERIFY EXACT MILLWORK SIZE WITH MANUFACTURER TO FIT IN SPACES PRIOR TO FABRICATION. SUBMIT SHOP DRAWINGS FOR REVIEW. DIMENSION NOTE: ROUGH OPENING DIMENSIONS SHALL BE COORDINATED WITH STRUCTURAL DRAWINGS AND DOOR / WINDOW DIMENSIONS AS PER MANUFACTURER REQUIREMENTS. G-C. SHALL NOTIFY ARCHITECT OF ANY DISCREPANCY PRIOR TO ORDERING AND INSTALLATION OF DOOR / WINDOWS_ TYP_ GENERAL FLOOR PLAN NOTES: 1, CHANGE OF ELEVATION AT ALL DOOR THRESHOLDS SHALL NOT EXCEED 1/2'. 2. LEVEL AREAS REQUIRED ON BOTH SIDES OF DOORS AS PER 5 -2.1 NFPA 101_ 3. EXISTING SPACE, UNDER CONTRACT, REFERS TO ONE STORY ONLY. 4, FIRE EXTINGUISHERS SHALL BE LOCATED AS INDICATED IN FLOOR PLAN AND IN GENERAL NOTES SHEET A0.02. 5, MIN. JAMB 6 HINGE SIDE SIDE OF DOORS SHALL BE '4'. GC. TO COORDINATE W/ FINISH MILLWORK/ DOOR MFR FLOOR PLAN KEYED NOTES: ITEM • DESCRIPTION ONEW VINYL COMPOSITE TILE ON EXISTING UNSEALED CONCRETE FLOOR SEE FINISH SCHEDULE A 6.13 FOR SPECS (TYP.) O2 30' HG, DESK BY TENANT (N.I:C) O3 NEW CABINETS TO MATCH EXISTING ADJACENT CABINETS_ SEE MILLWORK ELEVATIONS O SHEET A4.12 O EXISTING ALUMINUM WINDOW OR STOREFRONT (NIC) (TYP) OEXISTING EXTERIOR WALLS (NIC) (TYP) FURRING AS PER WALL TYPE. SEE SHEET A5.11 O6 CLOSET. O7 EXISTING STRUCTURAL COLUMN TO REMAIN. O8 PROJECTION OF CEILING COVE ABOVE. SEE DETAIL 4/A1.13 O4' -0' W x V -6' H PASS THRU WINDOW INSTALLED a 34' AFF_ PROVIDE FROSTED TEMP_ GLASS ON ANODIZED ALUMINUM FRAME_ 10 EXISTING 1/2' MAX. CHANGE IN ELEVATION. (TYP) 11 EXISTING DOOR TO BE REMOVED AND REPLACED WITH FIRE RATED PARTITION, SEE WALL TYPES A5.11. EXISTING FIRE RATED WALL TO REMAIN, GC TO VERIFY PARTITION TO 12 COMPLY WITH UL DESIGN N U425_ SEE WALL TYPES A5.11_ Si RUC T 13 FUTURE TENANT EQUIPMENT 14 EXISTING WALL TO BE CONVERTED TO FIRE RATED PARTITION, SEE WALLPR3VED S TYPES A5.11_ 15 WALL MOUNTED FLAT SCREEN TV- (NJ.C) COORDINATE POWER d CABLE r WITH ELECTRICAL DRAWINGS. PROVIDE WOOD BACKING BETWEEN STUDS. 16 KITCHEN SINK IN NEW COUNTER SEE MILLWORK ELEVATIONS. SHEET A422 17 REFRIGERATOR BY OWNER (N.I:c) 18 EXISTING CABINET 4 SINK TO REMAIN, REFINISH d REPAIR AS REQUIRED. COORDINATE W/ OWNER FOR REUSE OF EXISTING PLUMBING FIXTURES. 19 56' WIDE COUNTER INSTALLED a 34' AFF_ PROVIDE ROUND CORNERS, SEE DETAIL AT SHEET A6.111 20 NEW RESTROOM, SEE A4.11 FOR ADDITIONAL INFORMATION - 21 HATCHED AREA DENOTES NEW PARTITION. SEE WALL TYPES SHEET A5.11. 22 EXISTING PARTITION TO REMAIN. SEE WALL TYPES SHEET A5.11. 23 EXISTING BUILDING JANITOR CLOSET. 24 EXISTING DRINKING FOUNTAIN ON GROUND FLOOR _ ■ C 0 m U- 0 L•` Ci Lu ?U H MIAM~ ',iC DEPT. :ZAL SECTION . 3 fir. � CA •z'•' Lo F Lu An C�.. .T Q nIDe 01 a i m w — — �Q } Q w u Lu u a U W p J - I �— W � 0 ci W .� O Q LL 0 0 Z W J N (� � o W Q 0 I L�„ ul 0 0 o _w � WoQ� Q Z LL W W � 6L a a o :34 ar 1' T J Z w/� 0 CL C\ 0 W�_ Z O 0 v � � U W ^ _ N U Z Q � J Q Ala N U °° � a W AW w V kLL ui LL O J � Q m0 o N U ® _w � O w w N 1L SHEET: DWN. CY / MS cHECIC *rZL C. SAQUI II, AIA S I_ DATE 08.10 .2011 p R. BID - ui R_ CONS - COMM_ 1040 -205 p Z