12-1210-0074
2 3 1 2 3
EXITS,.
M5
M CEILING; PLAN
(PARTIAL FIFTH FLOOR) SCALE 1/411= 1' -0"
t"IECHANICAL NOTES
S NEW 24 x 24 RETURN GRILLE TO BE LOCATED AS SHOWN. NO DUCTWORK
(PLENUM RETURN)
M2 NEW 24 X 24 SUPPLY DIFFUSER TO BE LOCATED AS SHOWN. CONTRACTOR TO
EXTEND EXISTING FLEX DUCT AS REQUIRED TO NEW LOCATION. (8/A -5.0)
M3 NEW 24 X 24 SUPPLY DIFFUSER TO BE LOCATED AS SHOWN. CONTRACTOR TO
8
PROVIDE 4 INSTALL NEW FLEX DUCT AS INDICATED TO NEW LOCATION, (8/A -5.0)
M4 PROVIDE 4 INSTALL STYLE "8" DYNAMIC FIRE DAMPER AT AT MAIN SUPPLY DUCT
(1 -HOUR FIRE RATED PARTITION)
M5 FIELD VERIFY EXISTING RETURN AIR OPENING HAS A FIRE DAMPER IF NOT, PROVIDE
4 INSTALL STYLE "B" DYNAMIC FIRE DAMPER AT FIRE RATED PARTITION (i /A -5.0)
M6 NEW 24" X 24" RETURN AIR OPENING ABOVE CEILING W/ FIRE DAMPER PROVIDE
4 INSTALL STYLE "B" DYNAMIC FIRE DAMPER AT FIRE RATED PARTITION (l- A/5.0)
M� REBALANCE EXISTING CFM'S TO NOTED AMOUNT IN PLAN. FIELD VERIFY EXISTING
8
CONDITIONS (TYPICAL)
M8 MECHANICAL CONTRACTOR TO TEST 4 BALANCE SYSTEM AND SUBMIT REPORT TO
OWNER ONCE INSTALLATION IS COMPLETE
M9 EXISTING THERMOSTATS TO REMAIN, FIELD VERIFY CONTROL WIRING AND OPERATION.
CONTRACTOR TO FIELD VERIFY EXISTING CONDITION OF VAV BOXES POWER,
ACTUATOR AND HEATER CONDITIONS PRIOR TO BID.
ELECTiRICAL NOTES
E1 RELOCATE EXISTING 2 X 4 PRISMATIC/PARABOLIC LIGHT FIXTURES AS INDICATED. VERIFY
LAMP AND BALLAST OPERATION. CLEAN TROFFER AND FRAME.
E2 RELOCATE EXISTING 6" DIAMETER RECESSED DOWNLIGHT FIXTURES AS INDICATED.
VERIFY LAMP AND TRANSFORMER OPERATION. CLEAN LENS AND TRIM.
E3 INTERCEPT EXISTING LIGHTING CIRCUIT IN RECEPTION AND CORRIDOR, AND ROUTE /CONNECT
RELOCATED LIGHTS AS INDICATED. DISCONNECT 3 -WAY SWITCH FROM ADJACENT LOBBY
E4 INTERCEPT EXISTING LIGHTING CIRCUIT IN RECEPTION AND ROUTE /CONNECT RELOCATED
DOWNLIGHTS AS INDICATED. SINGLE POLE, 20 AMP LIGHT SWITCH, MOUNTS 42" AFF
OINTERCEPT EXISTING LIGHTING CIRCUIT AND ROUTE /CONNECT NEW LIGHT SWITCH, WIRES
E5 AND CONDUIT TO THIS LOCATION. SINGLE POLE, 20 AMP LIGHT SWITCH, MOUNT Q 42" Am
E6 RELOCATE EXISTING WALL MOUNTED FIRE ALARM DEVICE (HS) AS INDICATED. EXTEND
CONTROL WIRING AS REQUIRED FOR THIS LOCATION AND CONNECT TO EXISTING SYSTEM.
E-I RELOCATE EXISTING CEILING MOUNTED SMOKE DETECTOR AS INDICATED. EXTEND
CONTROL WIRING AS REQUIRED FOR THIS LOCATION AND CONNECT TO EXISTING SYSTEM.
ES RELOCATE EXISTING WALL MOUNTED EMERGENCY LIGHT AS INDICATED. EXISTING LIGHTING
CIRCUIT AND WIRING TO REMAIN.
E9 RELOCATE EXISTING CEILING MOUNTED EXIT SIGN AS INDICATED. EXISTING LIGHTING
8
CIRCUIT AND WIRING TO REMAIN.
E €s/ T1N
of
ELECTIRIGAL FLOOfR/CEILING PLAN
(PARTIAL FIFTH FLOOR)
CONNECT TO EXISTING CIRCUIT FROM REMOVED OUTLET, USE 2 012 THWN CU 4 012 (GND)
E10 IN 1/2" CONDUIT. 20 AMP DUPLEX RECEPTACLE (NEMA 5 -20R), MOUNT o 18" AFF
EII CONNECT TO EXISTING SPARE CIRCUIT (DEDICATED), USE 2 "12 THWN CU 4 012 (C-ND)
IN 1/2" CONDUIT. 20 AMP DUPLEX RECEPTACLE WITH GROUND FAULT CIRCUIT INTERRUPTER
(NEMA 5 -20R), MOUNT a 48" AFF
E12 TELEPHONE/DATA OUTLET WITH 3/4" CONDUIT EXTENDED FROM WALL 6" ABOVE FINISHED
CEILING. MOUNT a 18" AFF TO CENTERLINE OF BOX
E13 PROVIDE AND INSTALL 2' X 2' X 3/4" BC PLYWOOD TELEPHONE BOARD PAINTED WITH 2
COATS OF FIRE RETARDENT WHITE PAINT. MOUNT 20 AMP DUPLEX RECEPTACLE
DIRECTLY ON BOARD. MOUNT 2" CONDUIT WITH PULL STRING AND RUN ABOVE CEILING TO
MAIN TELEPHONE BOARD ON FLOOR, TERMINATE CONDUIT WITH INSULATED BUSHING AT
BOARD. MOUNT GROUND BAR AT BASE OF BOARD WITH 1 1'2 GROUND TO NEAREST
EFFECTIVELY GROUNDED BUILDING STRUCTURAL MEMEBER.
... - APPROVED BY - -0
MIAMI -DADE COU0IN WAR=
w IA'T t & Al N, KYRTE- 4310N �._.
DX'
ALL EXISTING ELECTRICAL CIRCUITS TO REMAIN. EXTEND
CONDUITS AND BRANCH WIRING TO PROPOSED LOCATION
INDICATED ON PLAN. NO NEW OR ADDITIONAL CIRCUITS.
ALL EXISTING MAIN DISTRIBUTION DUCTWORK TO REMAIN.
EXTEND AND RELOCATE EXISTING FLEXIBLE DUCTWORK
TO PROPOSED- LOCATION INDICATED ON PLAN. TWO
ADDITIONAL FLEXIBLE DUCTS ADDED.
r
]RUIESCO��
ARCH IT EC.T
1750 PONCE DE LEON BLVD
CORAL GABLES, FL 33134
305.448.4288 305.444.4986
AA90020Z P
c G� r 10k✓ '
SEAL
AIL H DPS G? ARRANdffiNFJ
AND PIAIZ4 II�IDIGI�D OR REPRB9
TM BY THIS DRAWING ARE OWr
HY,AND THE PROPFRIY OF TIDE
FICE AND WERE EVDL1
JOONNECIION�
PROJECT. NMM OF SUCH HWAS> ]
SRINS, ARRANOI71ffi1 3 OR PIANS S9
BE USED BY OR DI9aMM TO I
PERSON FIRM OR CORPORATION
ANY PU�tP088 WHATSOEM WPl}R MSS
OF RMSM ARCHIf = PAR
oZN�
W
o ��
aW`��
or �
w � �
J
Q `
O r=
Fr
�Q
D Qz
oU� REVHONS
3::
EL co
CL 0
PROJECT NUMBER
12900
DATE
07/23/12
SHEET
MEP -1
Rw,