Loading...
11-220-0045GALE: 1/4" = 1' -0" NOTE: G.G. SHALL CONTACT AND COORDINATE WITH 'ELECTRASERVE', LANDLORD FIRE ALARM COMPANY FOR ANY AND ALL FIRE ALARM SYSTEM WORK SCOPE- TENANT OCCUPANCY FIRE SEPARATION NOTE: IT SHALL BE THE RESPONSABILITY OF THE LEASING AGENT TO ADVISE ARCHITECT OF THE PROPOSED TENANT'S USE(S) BASED ON CHAPTER 3, 'USE 4 OCCUPANCY CLASSIFICATION' OF THE LATEST EDITION OF THE FLORIDA BUILDING CODE (F.B.C.) TO DETERMINE IF THE SEPARATION PARTITIONS BETWEEN TENANTS ARE TO BE ONE (1) HOUR, TWO (2) HOURS OR MORE, PRIOR TO THE COMPLETION OF THE A/E DRAWINGS PER THE LANDLORD'S WORK SCOPE NOTE: ARCHITECT SHALL BE NOTIFIED WHEN FRAMING AND ROUGH INSTALLATIONS ARE COMPLETED FOR AN ON SITE VISIT PRIOR TO INSTALLATION OF DRYWALL. METAL STUD PARTITION NOTE5: 1. ALL METAL STUDS SHALL BE PROVIDED BY DIETRICH METAL FRAMING OR APPROVED EQUAL. 2. ALL DEMISING PARTITIONS TO DECK SHALL BE DIETRICH (o' STUDS 'CSW' 18 GA., a 24' O.G., TO A MAXIMUM HEIGHT OF 2(o' -0`, FOR 5PSF L/240. SHOULD CONDITION DIFFER, G.G. SHALL NOTIFY ARCHITECT IMMEDIATELY. 3. ALL REMAINING METAL STUDS SHALL BE 20 GAUGE UNLESS OTHERWISE NOTED, TYP. 4. ALL FIRE RATED WALLS SEPARATION AND /OR PENETRATIONS SHALL BE SEALED WITH AN UL LABELED FIRE RATED MATERIAL. G.C. SHALL BE RESPONSIBLE FOR PROVIDING ALL SHOP DRAWINGS AND /OR CUT SHEETS FOR ALL UL LABELED FIRE RATED MATERIALS NOT SPECIFIED IN CONSTRUCTION DOCUMENTS AND /OR SPECIFICATIONS, TYP. 5. ALL JOINTS/DEPRESSIONS OF THE GYPSUM WALL BOARD SHALL BE TAPED, APPLIED THREE COATS OF SPACKLE, AND SANDED TO A SMOOTH FINISH READY TO RECEIVE FINISH A5 PER SCHEDULE. WALLS AND CEILINGS ARE TO BE FREE OF ANY UNEVENNESS AT JOINTS AND CORNERS. ALL OUTSIDE CORNERS SHALL HAVE METAL BEAD AND SPACKLE, Ea, REFER TO FINISH SCHEDULE FOR FINISHES, TYP. 1. CONTRACTOR SHALL FIELD VERIFY THAT SLABS E FLOORS ARE NOT PRE -CAST, POST - TENSIONED, OR PRE - STRESSED PRIOR TO SHOOTING INTO SLAB, TYP. ro. G.C. SHALL SECURELY ATTACH METAL STUD FRAMING TO STRUCTURE ABOVE AND SHALL PROVIDE BRACING Q 32' O.G. ALTERNATING DIRECTIONS UNLESS OTHERWISE SPECIFIED, TYP. `8' GYPSUM BOARD BATT NSUL 5/8' MTL STUDS FIRE TEST : DESIGN U425 STC : 44-44 SOUND TEST: NCsC 2385 INTERIOR WALL (HORIZONTAL SECTION) EXTERIOR WALL (HORIZONTAL SECTION) I . - APRIL DESIGN No U425 PR L 22 2002 , NTERIOR SIDE OF FIRE CEILMG 3 5/8' MTL. CHANNEL 3 5/8' MTL STUDS 5/8 G BOARD 3'13ATT NSUL VINYL BASE 3 5/8' MTL CHANNEL SEALANT FLOOR (FOR EXTERIOR WALLS, RATINGS APPLICABLE FOR EXPOSURE TO FIRE ON INTERIOR FACE ONLY, SEE ITEMS 4 AND 41 BEARING WALL RATING - 45 MIN, 1, 1 -1/2, OR 2 HR SEE ITEMS 2 AND 4) 1. STEEL FLOOR AND CEILING TRACKS - (NOT SHOWN) - TOP AND BOTTOM TRACKS OF WALL ASSEMBLIES SHALL CONSIST OF STEEL MEMBERS, MIN NO. 20 MSG (0.0329 N, MIN BARE METAL THICKNESS) STEEL OR MIN NO. 20 GSG (OD36 IN, THICK) GALV STEEL OR NO. 20 MSG (0.033 IN. THICK) PRIMED STEEL, THAT PROVIDE A SOUND STRUCTURAL CONNECTION BETWEEN STEEL STUDS, AND TO ADJACENT ASSEMBLIES SUCH AS A FLOOR CEILING, AND /OR OTHER WALLS. ATTACHED TO FLOOR AND CEILING ASSEMBLIES WITH STEEL FASTENERS SPACED NOT GREATER THAN 24 IN. O.C, 2. STEEL STUDS - CORROSION PROTECTED STEEL STUDS, MIN NO. 20 MSG (0.0329 IN., MIN BARE METAL THICKNESS) STEEL OR MIN 3- 1/2 IN. WIDE, MIN NO. 20 GSG (0 .036 IN. THICK) GALV STEEL OR NO. 20 MSG (0.033 IN. THICK) PRIMED STEEL, COLD FORMED, SHALL BE DESIGNED IN ACCORDANCE WITH THE CURRENT EDITION OF THE SPECIFICATION FOR THE DESIGN OF GOLD- FORMED STEEL STRUCTURAL MEMBERS BY THE AMERICAN IRON AND STEEL INSTITUTE. ALL DESIGN DETAILS ENHANCING THE STRUCTURAL INTEGRITY OF THE WALL ASSEMBLY, INCLUDING THE AXIAL DESIGN LOAD OF THE STUDS, SHALL BE AS SPECIFIED BY THE STEEL STUD DESIGNER AND/OR PRODUCER AND SHALL MEET THE REQUIREMENTS OF ALL APPLICABLE LOCAL CODE AGENCIES. THE MAX STUD SPACING OF WALL ASSEMBLIES SHALL NOT EXCEED 24 IN. OC (OR 16 IN. OC - SEE ITEM 5C). STUDS ATTACHED TO FLOOR AND CEILING TRACKS WITH 1/2 IN. LONG TYPE 5 -12 STEEL SCREWS ON BOTH SIDES OF STUDS OR BY WELDED OR BOLTED CONNECTIONS DESIGNED IN ACCORDANCE WITH THE At SI SPECIFICATIONS. 3. LATERAL SUPPORT MEMBERS - (NOT SHOWN) - WHERE REQUIRED FOR LATERAL SUPPORT OF STUDS, SUPPORT MAY BE PROVIDED BY MEANS OF STEEL STRAPS, CHANNELS OR OTHER SIMILAR MEANS AS SPECIFIED IN THE DESIGN OF A PARTICULAR STEEL STUD WALL SYSTEM. STRUCTURE ABOVE EXISTING 3 5/8' - 20 GA. STEEL STUDS 6 24' O.C. WIT FIRESTOPS im 8' -0' CBEYON 4) NEW 5/8' GYPSUM BOARD + V -4 -TYPE 'X'- BOTH SIDES + EXISTING ACOUSTICAL CEILING TILES. EXISTING 5/8' GYPSUM BOARD TYPE 'X'- BOTH SIDES EXISTING 3 5/8' - 20 GA. STEEL STUDS IT 24' O.C. WITH FIR.ESTOPS ,w 8' -0' VERT. (BEYOND) EXISTING BASE AS PER ROOM + (4 ° -27" FINISH I I I I I l I jjI II 1� !� I I I I I I I I I I F I I I ( I I� XISTING 3 5/8' - 20 GA. TEEL RUNNER SECURELY NCHORED TO STRUCTURE BOVE. STANDARD 'T' HANGER WIRES SECURELY ATTACHED TO STRUCTURE ABOVE EXISTING 3 5/8' - 20 GA. STEEL RUNNER SECURELY ANCHORED TO FLOOR SLAB. FINISHED FLOOR 2nd FLOOR DISING 1 �PA_R'TITION TYPE - 1 UL -425 0" 0 6" it 2' SCALE: 1" = 1' -0" 4. GYPSUM BOARD* - GYPSUM WALLBOARD BEARING THE ULI CLASSIFICATION MARKING AS TO FIRE RESISTANCE. APPLIED VERTICALLY WITH JOINTS BETWEEN LAYERS STAGGERED. OUTER LAYER OF 3 LAYER CONSTRUCTION MAY BE APPLIED HORIZONTALLY. THE THICKNESS AND NUMBER OF LAYERS AND PERCENT OF DESIGN LOAD FOR THE 45 MIN, 1 HK 1 -1/2 HR AND 2 HR RATINGS ARE AS FOLLOWS: INTERIOR WALLS RATINGS WALLBOARD PROTECTION BOTH SIDES OF WALL - No. OF LAYERS AND THICKNESS OF BOARD In. EACH LAYER qo OF LOAD DESIGN 45 MIN. *1 LAYER 1/2 IN. THICK 100 1 HR *1 LAYER 5/8 IN. THICK 100 1 -1/2 HR *2 LAYER 1/2 IN. THICK 100 2 HR *2 LAYER 5/8 IN. THICK 80 *3 LAYER 1/2 1N. THICK 100 *2 LAYER 3/4 IN. THICK 100 *RATINGS APPLICABLE TO ASSEMBLIES SERVING AS EXTERIOR WALLS WHERE CLASSIFIED FIRE RESISTIVE GYPSUM SHEATHIN G TYPE WALLBOARD IS SUBSTITUTED ON THE EXTERIOR FACE. EXTERIOR WALLS RATINGS WALLBOARD PROTECTION ON INTERIOR SIDE OF WALL - No, OF LAYERS AND THICKNESS OF BOARD In. EACH LAYER 9a OF LOAD DESIGN 45 MIN. *I LAYER 5/8 IN. THICK 100 I HR *2 LAYER 1/2 IN. THICK 100 1 -1/2 HR *2 LAYER 5/8 IN. THICK 100 2 HR •3 LAYER 1/2 IN. THICK 100 •2 LAYER 3/4 IN. THICK 100 *RATINGS APPLICABLE TO ASSEMBLIES SERVING AS EXTERIOR WALLS WHERE CLASSIFIED FIRE RESISTIVE GYPSUM SHEATHIN G TYPE WALLBOARD IS SUBSTITUTED ON THE EXTERIOR FACE. SEE GYPSUM BOARD (CKNX) CATEGORY - FOR NAMES OF CLASSIFIED COMPANIES OF 1/2 IN. OR 5/8 IN. THICK WALLBOARD. SEE BELOW FOR CLASSIFIED COMPANY OF 3/4 IN. THICK WALLBOARD. CANADIAN GYPSUM COMPANY - TYPE IF-X3, ULTRACODE, ULTRACODE SHC OR ULTRACODE WRC. UNITED STATES GYPSUM CO - TYPE IF-X3, ULTRACODE, ULTRACODE SHC OR ULTRACODE WRC. USG MEXICO $A DE C V - TYPE IF-X3, ULTRACODE, ULTRAC.00E SHC OR ULTRACODEWRC. 4A, GYPSUM BOARD* - (AS AN ALTERNATE TO 5/8 IN THICK WALLBOARDS IN ITEM 4) - NOM 3/4 IN. THICK CANADIAN GYPSUM COMPANY - TYPES AR IP -AR UNITED STATES GYPSUM CO - TYPES AR IF-AR USG MEXICO S A DE C V - TYPES AR IF-AR 5. GYPSUM SHEATHING - FOR EXTERIOR WALLS, 1/2 OR 5/6 IN. THICK EXTERIOR REGULAR GYPSUM SHEATHING APPLIED VERTICALLY AND ATTACHED TO STUDS AND RUNNER TRACKS WITH I IN. LONG TYPE 5 -12 BUGLE HEAD SCREWS SPACED 12 IN OC. ALONG STUDS AND TRACKS, ONE OF THE FOLLOWING EXTERIOR FACINGS ARE TO BE APPLIED OVER THE GYPSUM SHEATHING. A. SIDING, BRICK, OR STUCCO - ALUMINUM SIDING, STEEL SIDING, BRICK VENEER OR STUCCO ATTACHED TO STUDS OVER GYPSUM SHEATHING AND MEETING THE REQUIREMENTS OF LOCAL CODE AGENCIES. WHEN A MIN 3 -3/4 M. THICK BRICK VENEER FACING IS USED, THE EXTERIOR WALL RATING IS APPLICABLE WITH EXPOSURE ON EITHER FACE. BRICK VENEER WALL ATTACHED TO STUDS WITH CORRUGATED METAL WALL TIES ATTACHED TO EACH STUD WITH STEEL SCREWS, NOT MORE THAN EACH SIXTH COURSE OF BRICK B. MINERAL AND FIBER BOARDS, - EXTERIOR HARD BOARD PANELING, CHEMICALLY TREATED OVER GYPSUM SHEATHING WITH PRIMED OR FNISHED FACE, 1/16 IN. THICK BY 48 IN. WIDE. ATTACHED TO STUDS OVER GYPSUM SHEATHING WITH 1 -1/8 IN. LONG BUGLE -HEAD TEK FASTENERS 16 IN. OC AT THE INTERMEDIATE SUPPORTS OR EXTERIOR LAP SIDING, CHEMICALLY TREATED, 1/16 IN, THICK BY 8 IK OR 12 IN. WIDE. ATTACHED TO STUDS WITH 1 -1/8 IN. LONG, BUGLE -HEAD TYPE TEK FASTENERS AT EACH LAP. PANELS LAPPED MINIMUM 1 IN. C. CEMENTITIOUS BACKER UNITS- - 1/2 OR 5/6 IN. THICK SQUARE EDGE BOARDS, ATTACHED TO STEEL STUDS OVER GYPSUM SHEATHING WITH 1 -5/6 IN. LONG, TYPE 5 -12, CORROSION RESISTANT, WAFER HEAD STEEL SCREWS, SPACED 8 IN. OC. STUDS SPACED A MAX OF 16 IN. OC. JOINTS COVERED WITH GLASS FIBER MESH TAPE. UNITED STATES GYPSUM CO - DUROCK EXTERIOR CEMENT BOARD OR DUROCK BRAND CEMENT BOARD. D. FIBER - CEMENT SIDING -- FIBER- CEMENT EXTERIOR SIDINGS INCLUDING SMOOTH AND PATTERNED PANEL OR LAP SIDING. E. MOLDED PLASTIC* - SOLID VINYL SIDING MECHANICALY SECURED TO FRAMING MEMBERS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDED INSTALLATION DETAILS. ASSOCIATED MATERIALS INC STRUCTURE ABOVE NEW 3 5/8' - 20 GA. STEE STUDS 24' O.G. WIT FIRESTOPS V -0' VERT. (BEYON I) NEW 5/8' GYPSUM BOARD TYPE 'X'- BOTH SIDE + 8' -0' 7iTIII EXISTING ACOUSTICAL CEILING TILES. EXISTING 5/8' GYPSUM BOARD TYPE 'X'- BOTH SIDES EXISTING 3 5/8' - 20 GA. STEEL STUDS a 24' O.C. WITH FIRESTOPS 61 8' -0' VERT. (BEYOND) EXISTING BASE AS PER ROOM FINISH + 0' -0' I I I I I I I I i z � I I 7I I I I �u w I I I I I TO I I `I 2nd FLOOR R� t L V [STING -EL RUt�NER SECURELY:. 'HOREr, TO STXUCTURE STANDARD 'T' HANGER WIRES SECURELY ATTACHED TO STRUCTURE ABOVE EXISTING 3 5/8' - 20 GA. STEEL RUNNER SECURELY ANCHORED TO FLOOR SLAB. FINISHED FLOOR DEMISING - 2 PARTITION TYPE 2 UL -425 1 " = 1-0 0 6" 1" 2 SCALE: 1" = 1' -0" v� STRUCTURE + 8' -4* + 8 ° -m' 1 I 2'X2' FISSURED ACOUSTICAL CEILING., TO MATCH EXISTING. 5/8' - 25 GA. STEEL RUNNER ECURELY ANCHORED TO TRUCTURE ABOVE. STANDARD 'T' HANGER WIRES SECURELY ATTACHED TO STRUCTURE ABOVE 3 5/8' - 25 GA. STEEL RUNNER SECURELY ANCHORED TO FLOOR SLAB. FINISHED FLOOR I 4°IGA I- �V4/�`4 � WWII G I I./9 ffimmw .® 0 a d m iu O m CA QWu QC W w a Q CJ O U DUN. w 0 O ®(L c�, a 1. DATE 01.102010 a I } u.. R BID d W R CONS. - GOl"tM, 1040 -205 p �(ry� U J z i ■ ■- ■ ■ SCALE: 1" = 1' -0" �, l"'L a, °�lEr a, 1 � ` C`', tl� �, 'Cta' x U L1 AidC1E iuL ALSIDE, DIV OF ` A * r "3 fl � HEARTLAND BUILDING PRODUCTS INC NEBRASKA PLASTICS INC 6. FASTENERS - (NOT SHOWN) - SCREWS USED TO ATTACH WALLBOARD TO STUDS- SELF-TAPPING BUGLE HEAD SHEET STEEL TYPE, SPACED 12 IN. O.C. FIRST LAYER TYPE 5 -12 BY I IN. LONG FOR 1/2 AND 5/6 IK THICK WALLBOARDS AND 1 -1/4 IN. LONG FOR 3/4 IN THICK WALLBOARD. SECOND LAYER TYPE 5 -12 BY 1 -5/6 IN. LONG FOR 1/2 AND 5/8 IN.1 THICK WALLBOARDS AND 2 -1/4 IN. LONG FOR 3/4 1N. THICK WALLBOARD. THIRD LAYER TYPE 5 -12 BY 1 -1/8 IN LONG. 1. BATTS AND BLANKETS, - PLACED IN STUD CAVITIES OF ALL EXTERIOR WALLS. MAY OR MAY NOT BE USED IN INTERIOR WALLS. ANY GLASS FIBER OR MINERAL WOOL BAIT MATERIAL BEARING THE UL CLASSIFICATION MARKING AS TO FIRE RESISTANCE, OF A THICKNESS TO COMPLETELY FILL STUD CAVITY. SEE BATTS AND BLANKETS (BZJZ) CATEGOR� FOR NAMES OF CLASSIFIED COMPANIES. 1A, FIBER, SPRAYED* - AS AN ALTERNATE TO BATTS AND BLANKETS (ITEM 1) -- SPRAY APPLIED CELLULOSE INSULATION MATERIAL. THE F15ER IS APPLIED WITH WATER TO COMPLETELY FILL THE ENCLOSED CAVITY IN ACCORDANCE WITH THE APPLICATION INSTRUCTIONS SUPPLIED WITH THE PRODUCT. NOMINAL DRY DENSITY OF 3D L5/FT3. U S GREENF15ER L L C- COCOON STABILIZED CELLULOSE INSULATION. S. JOINT TAPE AND COMPOUND - (NOT SHOWN) - VINYL OR CASEIN, DRY OR PREMIXED JOINT CONPOND APPLIED IN TWO COATS TO JOINTS AND SCREWS HEADS OF OUTER LAYER PERFORATED PAPER TAPE, 2 R WIDE, EMBEDDED IN FIRST LAYER OF COMPOUND OVER ALL JOINTS OF OUTER LAYER *BEARING THE UL CLASSIFICATION MARK. a W CJ O U DUN. MARIO F. SERRALTA O CHECK ANGEL C. SAOUI 11, AIA 1. DATE 01.102010 a I ut R BID d W R CONS. - GOl"tM, 1040 -205 p �(ry� U J z a Q W � 0 o = a � 4 ^0 W � o SCALE: 1" = 1' -0" �, l"'L a, °�lEr a, 1 � ` C`', tl� �, 'Cta' x U L1 AidC1E iuL ALSIDE, DIV OF ` A * r "3 fl � HEARTLAND BUILDING PRODUCTS INC NEBRASKA PLASTICS INC 6. FASTENERS - (NOT SHOWN) - SCREWS USED TO ATTACH WALLBOARD TO STUDS- SELF-TAPPING BUGLE HEAD SHEET STEEL TYPE, SPACED 12 IN. O.C. FIRST LAYER TYPE 5 -12 BY I IN. LONG FOR 1/2 AND 5/6 IK THICK WALLBOARDS AND 1 -1/4 IN. LONG FOR 3/4 IN THICK WALLBOARD. SECOND LAYER TYPE 5 -12 BY 1 -5/6 IN. LONG FOR 1/2 AND 5/8 IN.1 THICK WALLBOARDS AND 2 -1/4 IN. LONG FOR 3/4 1N. THICK WALLBOARD. THIRD LAYER TYPE 5 -12 BY 1 -1/8 IN LONG. 1. BATTS AND BLANKETS, - PLACED IN STUD CAVITIES OF ALL EXTERIOR WALLS. MAY OR MAY NOT BE USED IN INTERIOR WALLS. ANY GLASS FIBER OR MINERAL WOOL BAIT MATERIAL BEARING THE UL CLASSIFICATION MARKING AS TO FIRE RESISTANCE, OF A THICKNESS TO COMPLETELY FILL STUD CAVITY. SEE BATTS AND BLANKETS (BZJZ) CATEGOR� FOR NAMES OF CLASSIFIED COMPANIES. 1A, FIBER, SPRAYED* - AS AN ALTERNATE TO BATTS AND BLANKETS (ITEM 1) -- SPRAY APPLIED CELLULOSE INSULATION MATERIAL. THE F15ER IS APPLIED WITH WATER TO COMPLETELY FILL THE ENCLOSED CAVITY IN ACCORDANCE WITH THE APPLICATION INSTRUCTIONS SUPPLIED WITH THE PRODUCT. NOMINAL DRY DENSITY OF 3D L5/FT3. U S GREENF15ER L L C- COCOON STABILIZED CELLULOSE INSULATION. S. JOINT TAPE AND COMPOUND - (NOT SHOWN) - VINYL OR CASEIN, DRY OR PREMIXED JOINT CONPOND APPLIED IN TWO COATS TO JOINTS AND SCREWS HEADS OF OUTER LAYER PERFORATED PAPER TAPE, 2 R WIDE, EMBEDDED IN FIRST LAYER OF COMPOUND OVER ALL JOINTS OF OUTER LAYER *BEARING THE UL CLASSIFICATION MARK. COP m ut O U (L 1u a O OL W n` � 1L F- O H o W W -A d) u_ tu U d U lu 3� 4 �A • s • SHEET: CJ O U DUN. MARIO F. SERRALTA O CHECK ANGEL C. SAOUI 11, AIA 1. DATE 01.102010 a I ut R BID d W R CONS. - GOl"tM, 1040 -205 p z vco 0 co 4 W � o _ UJ a U co co j Q m QNov COP m ut O U (L 1u a O OL W n` � 1L F- O H o W W -A d) u_ tu U d U lu 3� 4 �A • s • SHEET: CJ O U DUN. MARIO F. SERRALTA O CHECK ANGEL C. SAOUI 11, AIA 1. DATE 01.102010 a ut R BID d W R CONS. - GOl"tM, 1040 -205 p z