11-1116-005I
so a a :60i
D 0 0 R S
DOOR HARDWARE NOTES
B.)
ALL RE-KEYING BY TENANT MUST BE COORDINATED THROUGH LANDLORDS BUILDING MGNT. OFFICE.
TYPE LIGHT FIXTURE
TENANT ENTRY:
C.)
PROVIDE WALL MOUNTED DOME STOPS 0 EACH DOOR.
(D
NEW BLDG. STAND, THERMOSTAT, TYP,
D,)
HARDWARE SHALL COMPLY WITH ARTICLE 515,3 (F) 3AA OF F,B,C.
2
"E"
OFFICE
INTERIOR LOCK SET
E.)
ALL HARDWARE To BE US 26 FINISH (BRUSHED CHROME FINISH)
EXISTING
"Rpl
REMOVE
OFFICE
F.)
PROVIDE DOOR FRAMES PER BLDG, STANDARD,
INTERIOR PASSAGE SET:
G.)
CONTRACTOR SHALL PROVIDE HARDWARE PRODUCT INFO. FOR ARCHIT, REVIEW
RELOCATED
INTERIOR MILLWORK
LATCH SET:
PRIOR TO PURCHASE OF HARDWARE.
H.)
ALL DOOR HARDWARE SHALL BE A.D.A. APPROVED LEVER HANDLE,
E
ELECTRONIC BUZZER
LATCH SET.
EGRESS CONTROLLED DOORS SHALL COMPLY W/ N.F.P.A. 101,5-2.1.5
SELF CLOSING
DOOR HINGE.
J.)
DOORS THAT LEAD TO TENANT SPACE TO HAVE ACCESS CONTROL HARDWARE
AND SHALL COMPLY WITH THE PROVISIONS OF NFPA 101-7.2.1.6.2.
HINGES:
DOOR A: SHALL BE CONTROLLED WITH THE USE OF A MAG-LOCK TYPE LOCKING DEVICE
THAT SHALL PERMIT INGRESS WITH THE USE OF A CARD SWIPE AND SHALL PERMIT EGRESS
BY MEANS OF A MOTION SENSOR AS YOU APPROACH THE DOORS, OR A RELEASE DEVICE
DOOR STOPS:
THAT READS- "PUSH TO EXIT", THIS SYSTEM SHALL ALSO RELEASE AND ALLOW EGRESS
UPON ACTIVATION OF FIRE ALARM. SEE ENGINEERING DRAWINGS FOR MORE DETAILS.
DOOR CLOSERS.
aQQa_3_ SHALL BE CONTROLLED BY THE USE OF AN ELECTRIC STRIKE TYPE LOCKING DEVICE
THAT SHALL PERMIT INGRESS WITH THE USE OF A CARD SWIPE AND SHALL PERMIT EGRESS
10
SILENCERS:
BY MEANS OF A MANUAL LEVER TYPE HANDLE. TYR, SEE ENGINEERING DRAWINGS FOR MORE
0 DENOTES EXISTING BUILDING STRUCTURE TO REMA I
Km
0
LEGEND
PROPOSED BUILDING STANDARD 2' X 2' ACOUSTICAL CEILING,
PROPOSED BUILDING STANDARD 2' x 4' - 18 CELL PARABOLIC
FLUORESCENT LIGHT FIXTURE.
CONTRACTOR SHALL COORDINATE FOR FIXTURE TYPE.
PROPOSED BUILDING STANDARD 2' x 2' - 9 CELL PARABOLIC
FLUORESCENT LIGHT FIXTURE.
CONTRACTOR SHALL COORDINATE FOR FIXTURE TYPE,
0
HVAC LEGEND
TYPE LIGHT FIXTURE
NEW A/C SUPPLY-AIR GRILLE.
zNEW
A/C RETURN-AIR GRILLE,
(D
NEW BLDG. STAND, THERMOSTAT, TYP,
0 DENOTES EXISTING BUILDING STRUCTURE TO REMA I
Km
0
LEGEND
PROPOSED BUILDING STANDARD 2' X 2' ACOUSTICAL CEILING,
PROPOSED BUILDING STANDARD 2' x 4' - 18 CELL PARABOLIC
FLUORESCENT LIGHT FIXTURE.
CONTRACTOR SHALL COORDINATE FOR FIXTURE TYPE.
PROPOSED BUILDING STANDARD 2' x 2' - 9 CELL PARABOLIC
FLUORESCENT LIGHT FIXTURE.
CONTRACTOR SHALL COORDINATE FOR FIXTURE TYPE,
0
PROPOSED HI-HAT
TYPE LIGHT FIXTURE
22 N
NEW
CITY SOS _rii MlAiMl
BUCAF.
ILDING DEP7-
"E"
STRuCTURALSECT1014
EXISTING
"Rpl
REMOVE
"RLJ)
RELOCATED
NOTE,
SYMBOLS ARE FOR REFERENCE ONLY, REFER TO PARTICULAR
BLDG, DISCIPLINE SHEETS FOR SPECIFIC FIXTURE TYPES, AND
SPECIFICATIONS,