10-650-0205�0G 0 VA � nNG 4. ��pFO Nf 500K E0 2 EA'¶NG E PROJECT NOTES —ALL DISCONNECTED PLUMBING LINES FOR EXISTING FIXTURES SHALL BE CAPPED.NO LINES SHALL REMAIN OPEN TO THE ATMOSPHERE — INSTALL A WATER HAMMER ARRESTER FOR EACH PLUMBING FIXTURE SUPPLY BRANCH USING TABLE (2/P -2) — INSTALL A SHUTOFF VALVE ON THE FIXTURE SUPPLY TO EACH PLUMBING FIXTURE. —THE INSTALLATION OF ANY PART OF PLUMBING SYSTEM SHALL BE ACCORDING TO FBC —P SECTION 307 —ANY PLUMBING LINES WHICH REQUIRE REMOVAL AND /OR ALTERATION, G.C. SHALL CAP AND FILL SLAB WITH SAME FIRE RATED INTEGRITY. — PROVIDE METAL SLEEVE AT ALL WALL AND SLAB PENETRATIONS. —ALL HORIZONTAL DRAIN PIPE 2 "M OR SMALLER SHALL BE SLOPED AT 1 /4 " /FT —ALL HORIZONTAL DRAIN PIPE FROM 3" TO 6" SHALL. BE SLOPED AT 1 /8 " /FT MIN. —ALL HORIZONTAL DRAIN PIPE 8" OR LARGER SHALL BE SLOPED AT 1 /16 "/FT MIN — PROVIDE AUTOMATIC TRAP RESEAL FOR ALL FLOOR DRAINS CONNECT NEW LINES TO EXISTING, VERIFY EXACT LOCATION,SIZE & CAPACITY IN FIELD PRIOR TO BID THE PROJECT. NOTIFY ARCHITECT & ENGINEER OF ANY DISCREPANCIES. CONTRACTOR IS STRONGLY ENCOURAGE TO PERFORM A VISIT TO VERIFY ALL CONDITIONS THAT MAY AFFECT THE SCOPE OF WORK.CONTRACTOR NOT PERFORMING A SITE VISIT ARE ACKNOWLEDGING AND ACCEPTING ALL SITE CONDITIONS AS THEY EXIST. VERIFY: POINTS OF CONNECTIONS; EXISTING LINES ( SIZE, CAPACITY, MATERIALS, ....) —ALL PLUMBING WORK PERFORMED UNDER THIS CONTRACT SHALL COMPLY WITH LOCAL CODES AND ORDINANCES AND ALL STANDARDS OF CONSTRUCTION ESTABLISHED BY THE LANDLORD. — SUBMIT SHOP DRAWINGS FOR ACCEPTANCE BY THE ARCHITECT AND /OR ENGINEER BEFORE PROCEEDING WITH THE PURCHASE OR INSTALLATION OF THE EQUIPMENT AND MATERIALS. NO FACSIMILES OR FACSIMILE COPIES SHALL BE ACCEPTED. —IF ANY CONFLICT IS ENCOUNTERED WITHIN THE DESIGN DOCUMENTS, REGARDLESS OF TRADE OR RESPONSIBILITY, THE GREATER SCOPE OF WORK SHALL PREVAIL —THESE PLANS ARE FOR BUILDING DEPARTMENT REVIEW ONLY. THEY ARE NOT TO CONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENT APPROVALS ARE OBTAINED. — CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS BEFORE PROCEEDING WITH WORK.IF ANY DISCREPANCIES, ERRORS OR OMISSIONS ARE ENCOUNTERED ON PLANS, CONTRACTOR SHALL NOTIFY ARCHITECT/ ENGINEER BEFORE ANY PART OF THE WORK IS STARTED SO THAT PROPER CORRECTIONS BE MADE. IF ARCHITECTS/ENGINEER IS NOT NOTIFIED PRIOR TO COMMENCING OF THE WORK, THE CONTRACTOR SHALL. BEAR FULL RESPONSIBILITY FOR ANY DISCREPANCIES , ERROR OR OMISSIONS. � p SANITARY RISER WATER HAMMER. THE FLOW VELOCITY OF THE WATER DISTRIBUTION SYSTEM SHALL BE CONTROLLED TO REDUCE THE POSSIBILITY OF WATER HAMMER. A WATER — HAMMER ARRESTOR SHALL BE INSTALLED WHERE QUICK — CLOSING VALVES ARE UTILIZED. WATER — HAMMER ARRESTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. WATER — HAMMER ARRESTORS SHALL CONFORM TO ASSE 1010 . Q ®�ESnG EXISING 2 � ?4 INSTANT WATER HEATER CHRONOMITE MODEL M -20L 5.54 KW , 277 VOLTS EXISTING 4" WASTE STACK EXISTING 2" DOMESTIC WATER EXISTING 3" VENT STACK 4� S.S. SINGLE COMPARTMENT SINK W/ GOOSENECK FAUCET (LEVER HANDLES) PLUMBING Scale: Y40 = 1'-0w + 1 ENGINEERING b''ESIGN 21 SW ■ tl 786.E363-7091 ■ ■ :D P=1 00 .j ERGUIN CAPOTE PE No. 62487 Luis CL "• ■ GUTIERREZ PE No. 66391 151 SEVILLA AVENUE, SUITE 200 CORAL GABLES, FL 33134 OFFICE: (305) 442 -1188 FAX: (305) 445 -1509 WWW. ADCINTERNATIONAL.NET STATE OF FLORIDA AR- 0010536 RAYMUNDO FEITO, R.A. AA— CO01315 Architect • Seal/Signature Construction Documents for: HE"c111111111 1 S ,& 3M at: ONE 7000 PLACE 3rd FLOOR 7000 SW 62nd AVENUE SOUTH MIAMI, FL 33143 Consultant • Seal/Signature