10-650-013r 1 ` 011 r ��­���� 'ii� 11� Scale: 1/8"= V-0" -I I!-_; t I - ° . _... OR • r WALLBOARD/STUD STEEL SLEEVE. SCH • •` HEAVIER) STEEL PIPE WITH LENGTH FLOOR/WALL AS SAME AS TO # r •- • •- CONDUIT r . •- OR RIGID COMPLETELY FILL ANNULAR SPACE AND THICKNESS OF FLOOR OR WALL WITH - BE DOMED ON BOTH SIDES OF ASSEMBLY TO A 1/2" HEIGHT IN ADDITION TO THICKNESS REQUIRED . RICNEW01 GENERAL NOTES 1- INSTALLATION SHALL BE DONE IN STRICT ACCORDANCE WITH THE FLORIDA BUILDING CODE 2007 WITH 2009 SUPPLEMENTS AND NEC 2008. 2- ALL CONDUCTORS SHALL BE COPPER, THWN TYPE RATED AT 750C. 3- ALL CONDUITS SHALL BE E.M.T. UNLESS INDICATED OTHERWISE. 4- ALL RECEPTACLES AND LIGHT SWITCHES SHALL HAVE AN ENGRAVED BRANCH CIRCUIT IDENTIFICATION PLATE INDICATING PANEL AND CIRCUIT NUMBER. 5- PROVIDE TYPED CIRCUIT INDEX FOR ALL NEW AND EXISTING PANELBOARDS. 6- PROVIDE ALL REQUIRED PERMITS AND PAY ALL FEES. 7- ALL BOXES SHALL BE METALLIC. 8- ALL RECEPTACLES SHALL BE 18" A.F.F. UNLESS INDICATED OTHERWISE. 9- PROVIDE A GREEN GRID. WIRE TO ALL RECEPTACLES, AND FIXED EQUIPMENT. 10- CONTRACTOR MUST VISIT SITE TO BECOME FAMILIAR WITH EXISTING CONDITIONS BEFORE BIDDING THIS JOB. 11- CONTRACTOR SHALL INSTALL ALL ELECTRICAL EQUIPMENT FURNISHED BY THE OWNER OR OTHER CONTRACTOR. 12- ALL CONDUITS SHALL RUN CONCEALED U.I.O. 13- PROVIDE COVER PLATES FOR ALL OUTLETS. 14- ALL CONDUIT PENETRATIONS OF FIRE -RATED WALLS, FLOORS, AND CEILINGS SHALL BE SEALED IN ACCORDANCE WITH REQUIREMENTS OF NEC ARTICLE 300 -21 AND DETAILS I AND 11 ON THIS SHEET. 15- PROVIDE ALL THE REQUIRED WIRING AND CONDUIT. 16- FOR ALL DISCONNECTS PROVIDE NEMA 1 ENCLOSURE INDOORS AND NEMA 3R ENCLOSURE OUTDOOR. 17- ALL ELECTRICAL SWITCHES SHALL BE 48" A.F.F. UNLESS INDICATED OTHERWISE. 18- ALL LIGHT SWITCHES SHALL HAVE AN ENGRAVED BRANCH CIRCUIT IDENTIFICATION PLATE INDICATING PANEL AND CIRCUIT NUMBER. 19- COORDINATE MOUNTING HEIGHT OF ALL LIGHTING FIXTURES WITH ARCHITECT. 20- SHEETS WITH NOTES IN HEXAGON ARE FOR SPECIFIC LOCATIONS. NOTES WITHOUT HEXAGON ARE GENERAL NOTES FOR THAT SHEET. 21- ALL FLUORESCENT FIXTURES SHALL USE ENERGY CONSERVATION BALLAST AND LAMPS LAMPS (GE OR SYLVANIA) 22- ALL CONDUITS RUNNING UNDERGROUND BE PVC SCHEDULE 40 1" MINIMUM. 23- ALL CONDUITS RUNNING EXPOSED IN EXTERIOR AREAS UP TO 8' -0" HIGH TO BE RIGID METALLIC CONDUIT. 24- ALL CONDUITS RUNNING CONCELEAD TO BE EMT TYPE. SYMBOL LEGEND I SYMBOL I DESCRIPTION I FLUORESCENT LIGHTING FIXTURE CEILING r IN NORMAL -• TYPE AS SPECIFIED FLUORESCENT DOWNLIGHT CEILING MTD. TYPE AS SPECIFIED. (Z} CEILING /WALL MTD. EXIT LIGHT. CEILING /WALL MTD. EMERGENCY LIGHT. it TELEPHONE OUTLET MTD 18" AFF.,U.1.0 DATA OUTLET MTD. 18" A.F.F.,U.I.O n FIRE ALARM SYSTEM PHOTOELECTRIC SMOKE DETECTOR ADDRESSABLE TYPE. FIRE MTD. AT 8 r FROM FINISHED FLOOR TO BOTTON OF STROBE FIRE ALARM SYSTEM r AT .• r FROM FINISHED FLOOR TO BOTTON F DEVICE. 20A, 120/277VAC SINGLE POLE TOGGLE SWITCH, SPECIFICATION GRADE 4' -0" A.FF.F. $3 THREE WAY SWITCH, SAME AS ABOVE 20A, 125V, 3 WIRE GROUNDING TYPE SPECIFICATION GRADE DUPLEX RECEPTACLE, MTD. 18" A.F.F., U.I.O. 20 A. 125V. 3 WIRES GROUND TYPE SPECIFICATION GRADE QUADRUPLEX RECEPT. MTD. 18" A.F.F., U.I.O. 20A, 125V, 3 WIRE GROUND FAULT INTERRUPTER DUPLEX RECEPTACLE, 6" ABOVE COUNTERS OR 42" A.F.F., U.I.O. (2) MOTOR, NUMBER IN CIRCLE DENOTES HORSE POWER RATING Q�r® CEILING OR WALL MTD. JUNCTION BOX SURFACE WALL MTD. PANELBOARD FLUSH MTD. PANELBOARD 330 SAFETY DISCONNECT • OF POLES, 15 15=FUSE SIZE, • r -140TE: ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED FOR THIS PROJECT- 151 SEVILLE` AVENUE c'..'IT2 2GG ~ " " CORAL GABLES, FL 33134 OFFICE: (305) 442 -1188 FAX: (305) 445 -1509 WWW. ADCINTERNATIONAL.NET Date & Delta Description Drawn By Checked By a 1 04/15/2011 P &G LP I BLDG DEPT. COMM. Client Information HEALTHCARE REALTY ONE 7000 Place SUITE PHN MIAMI, FL 33133 OFFICE: (305) 446 -3666 Project Number 09126 CAD File Name ONE 7000 PLACE - HEALTH SOUTH SUITE330 - DR. BONNER Description ELECTRICAL NOTES AND OVERALL PLAN Scale AS NOTED