DEMOLITION PROJECT NOTES:
}
EXISTING
BUILDING EXTERIOR STRUCTURE TO REMAIN, TYP.
Q
EXISTING
EXTERIOR WINDOWS /GLAZING TO REMAIN, TYP,
EXISTING
ENTRY DOOR & FRAME TO BE REMOVED
EXISTING
INTERIOR PARTITION TO REMAIN, TYP.
EXISTING
INTERIOR DOORS & FRAME TO BE REMOVED, TYP.
EXISTING
FLUORESCENT FIXTURES TO BE REMOVED, TYP.
6
SEE ENGINEERING
DRAWINGS FOR FURTHER INFO.
61
EXISTING
METAL STUD FRAMING AROUND PERIMETER TO REMAIN; FRAMING
TO BE USED
FOR BUILD -OUT OF NEW CEILING
EXISTING
ELECTRICAL TO BE REMOVED, TYP. REFER TO ENGINEERING
DRAWINGS
FOR FURTHER INFO.
EXISTING
PIPES TO REMAIN, REFER TO ENGINEERING
6 3
DRAWINGS
FOR FURTHER INFO.
(7
DASHED
LINE DENOTES EXISTING INTERIOR PARTITION TO BE REMOVED, TYP.
EXISTING
LOWER & UPPER CABINETS TO BE REMOVED
EXISTING
ADJACENT TENANT SPACE (N.I.C.)
10
EXISTING
COMMON AREA CORRIDOR. (N.I.C.)
11
EXISTING
CORRIDOR PARTITION TO REMAIN. CONTRACTOR TO INSPECT EXISTING
PARTITION AND SEAL ALL PENETRATIONS AS REQUIRED PER CODE TYP.
12
EXISTING
PORTION OF CORRIDOR PARTITION TO BE REMOVED
13
EXISTING
DEMISING PARTITION TO REMAIN. CONTRACTOR TO INSPECT EXISTING
DEMISING
PARTITION AND SEAL ALL PENETRATIONS AS REQUIRED PER CODE TYP.
14
EXISTING
VINYL BASE TO BE REMOVED
1/4" = 1'-0"
CONSTRUCTION PROJECT NOTES:
1� EXISTING BUILDING EXTERIOR STRUCTURE TO REMAIN, TYP.
EXISTING EXTERIOR WINDOWS /GLAZING TO REMAIN, TYP.
3 EXISTING INTERIOR PARTITION TO REMAIN, TYP.
�4 EXISTING COMMON AREA CORRIDOR PARTITION TO REMAIN. CONTRACTOR
TO REVIEW AND INSPECT THE EXISTING CONDITIONS OF THE WALLS IN
THE COMMON AREA CORRIDOR TO ASSURE THAT PROPER DEMISING AND
FIRE RATING ARE MAINTAINED. CONTRACTOR SHALL PATCH AND REPAIR
DENOTED WALL AS REQUIRED. SEE SECTION, SHEET A -06 AS GUIDE FOR
PROPER ASSEMBLY.
EXISTING TENANT DEMISING PARTITION TO REMAIN. CONTRACTOR TO REVIEW
AND INSPECT THE EXISTING CONDITIONS OF THE WALLS IN THE COMMON
AREA CORRIDOR TO ASSURE THAT PROPER DEMISING AND FIRE RATING ARE
MAINTAINED.
6 EXISTING ADJACENT TENANT SPACE
7 PROPOSED BUILDING STANDARD INTERIOR PARTITION, TYP. SEE SECTION 1,
SHEET A -6 FOR DETAIL.
PROPOSED 3' x 7! BUILDING STANDARD S.C. WD. TENANT ENTRY DOOR, TYP.
PROPOSED 3' x 7' BUILDING STANDARD S.C. WD. INTERIOR DOOR, TYP.
1O PROPOSED BI -FOLD DOORS
11 PROPOSED UPPER AND LOWER CABINETS WITH NEW SINK AND FAUCET; FOR
DETAILS REFER TO SHEETS A -05 AND A -06
12 PROPOSED UPPER AND LOWER CABINETS; FOR DETAILS REFER TO SHEETS
A -05 AND A -06
13 PROPOSED BUILT -IN DESK AND UPPER CABINETS; FOR DETAILS REFER TO
SHEETS A -05 AND A -06
14 PROPOSED LEDGE AT 36" A.F.F.; FOR DETAILS REFER TO SHEETS A -05 AND A -06
15 EXISTING COLUMNS TO BE FURRED WITH 1/2" DRYWALL ALL AROUND
16 EXISTING PIPES TO BE FURRED WITH 1/2" DRYWALL
17 PROPOSED PORTION OF COMMON CORRIDOR WALL TO BE BUILT;
FOR DETAILS REFER TO SHEET A -0.6
THIS FACILITY WILL NOT # Or • MORE PATIENTS
'RENDERED OF # DUE TO ANESTHESIA, DIALYSIS,
ANY PROCEDURE, OR
• F, A i • • •
.'", 119"'
# i r
THE rr IS A PORTABLE # IGITAL X-RAY IMAGING EQUIPMENT THAT STORES
ELECTRONICALLY.
THESE IMAGES CAN BE VIEWED BY DOCTOR ON # #• PLACED IN THE ROOM.
THE IMAGES WIH NOT PROCESSED #• DEVELOPED • ON
THIS PERMIT SHALL NOT INCLUDE FOR PROCESSING r'
NO WET " PROCESSING OF • IN THIS SUITE.
CITY OF I i
BUILDING
STRUCTURAL S4',ION
RM
r••M #
ii �i•i �
DOOR
•
DOOR
i •' i••'
r
0
Construction Documents for:
HE'LlIL
13M
at:
ONE 7000 PLACE
3rd FLOOR
7000 SW 62nd AVENUE
SOUTH MIAMI. FL 33133
Issue Date & Issue Description Drawn By Checked By
Q1 03 01 10 JP AR
Client Information
HEALTHCARE REALTY
ONE 7000 Place
SUITE PHN
MIAMI, FL 33133
OFFICE: (305) 446 -3666
Project Number
09126
CAD File Name
ONE 7000 PLACE - HEALTH SOUTH SUITE330 - DR. BONNER
Description
DEMOLITION /CONSTRUCTION PLAN
Scale
I
Consultant • Seal/Signature