10-649-018O L= 0.25xW(4" MIN.). Q VOLUME CONTROL DAMPER WITH LOCKING NUT. PROVIDE INSULATION STAND OFF BRACKET FOR ALL INSULATED DUCTS. 2� OVER 12" HIGH USE MULTIPLE BLADES. NOTE: EXHAUST AND RETURN TAKE OFF IS SIMILAR. BRANCH TAKE OFF DETAIL. SCALE: N.T.S. 1/8 "0 HANGER ROD SUPPORT fFROM EXISTING STRUCTURE WITH A 1/4" BOLT, 1" EMBEDMENT. HANGER BAND OF SAME SIZE AS HANGER STRAP SHEET METAL � 36" (914 MM) SADDLE MINIMUM DIA. MAX. 5' -0" ON CENTER 6" MIN. FIBROUS ROUND AND FLEXIBLE DUCT NOTE: HANGERS SHALL BE LOCATED AT DUCT JOINTS OR AS CLOSE AS POSSIBLE AS PER SMACNA DUCT CONSTRUCTION STANDARDS (Existing/New ROUND DUCT SUPPORT DETAIL. SCALE: N.T.S. STRUCTURE ABOVE. AR- 0010536 AA- CO01315 C.B. UNIVERSAL CONCRETE SUPPLY AIR DUCT Architect • Seal/Signature INSERTS GRINNELL FIG. 282 SEE PLAN FOR SIZES. OR EQUAL. -•- THREADED 1/4- Construction Documents for: \S-Qullr�11'14 P. AV at: ONE 7000 PLACE SUITE: 545 5th FLOOR 7000 SW 62nd AVENUE SOUTH MIAMI, FL 33143 STEEL ROD LOW PRESSURE DUCT AC AR PERMIT ISSUE 0 DOUBLE LOCK NUT AIR VOLUME CONTROL FLEXIBLE MEDIUM PRESSURE DUCT ACCESS DOOR NOTE: TERMINAL UNITS SHALL BE MOUNTED SO ACCESS DOOR AND DIAL CAN BE EASILY REACHED FROM BELOW NOTES a 1D EXISTING SUPPLY AIR DUCTWORK UPSTREAM OF VAV BOXES) 0 VAV CONTROLLERS AND ELECTRONIC THERMOSTATS CONNECTION SHALL BE IN ACCORDANCE WITH THE LATEST U a TO BE INSTALLED AS PER MANUFACTURER RECOMMENDATION EDITION OF SMACNA LOW PRESSURE DUCT MANUAL IL CO) AND TO MATCH EXISTING BLDG SYSTEM. LOCATION SHALL SUPPLY DUCTWORK SHALL BE INSULATED WITH 1" Z BE AS INDICATED. THICK FIBERGLASS BLANKET INSULATION WITH FOIL ® ALL SUPPLY AIR DIFFUSER OR RETURN AIR GRILLE WITH MANUAL KRAFT VAPOR BARRIER (R -4.2). N w 0 ALL SUPPLY AIR DUCTWORK DOWNSTREAM OF VAV BOXES O DAMPER, TO MATCH EXISTING. SHALL BE OF FIBERGLASS DUCTBOARD CONSTRUCTION, 1" Q5 SPACE OCCUPANCY REMAINS THE SAME (OFFICE). OUTSIDE AIR IN THICH (R -4.2) AND SHALL BE FABRICATED AND INSTALLED w REQUIREMENTS DO NOT VARY. AS PER LATEST EDITION OF SMACNA "FIBROUS DUCT MANUAL" ® SEAL ANY AIR LEAKS IN SUPPLY MAINS AND REPAIR ANY INSULATION. TYPICAL VARIABLE AIR VOLUME VAV BOX DETAIL. SCALE: N.T.S. Z Z IPRINTFO ON:07 -11 -2010 TURNING VAP SHEET METAL 5cREW FA5TENER5 OTES: ALL VANED ELBOWS SHALL BE CONSTRUCTED AND INSTALLED AS DETAILED BY SMACNA. WHEN W1 DOES NOT EQUAL W2 VANE SHALL BE SINGLE VANE TYPE REGARDLESS OF W DIMENSION. ALL SINGLE VANES SHALL HAVE A 2" RADIUS, 1 1/2" MAXIMUM SPACE BETWEEN VANES AND A 3/4" TRAILING EDGE. WHEN WI EQUALS WZ AND W IS GREATER THAN 20" VANES SHALL BE DOUBLE VANE TYPE. 90 ELBOW WITH TURNING VANES DETAIL. SCALE: N.T.S. 12 GAGE MINIMi SIZE SUPPORT EXISTING STRU( DUCT WORK 6 "x2 "x1/8" GALVANIZED STEEL CHANNEL. RIGID DUCT SUPPORT DETAIL. SCALE: N.T.S. SEAL JOINT WITH DUCT SEALER AND TAPE MANUAL VOLUME DAMPER DRAW BAND AIR LOW VELOCITY SUPPLY AIR DUCT (SEE PLAN VIEW) MANUAL VOLUME DAMPER INSTALL FLEXIBLE DUCT SUPPORT AS REQUIRED FOR NO SAG. SPIN COLLAR WITH INSULATED AND VAPOR SEALED DAMPER AND COLLAR AND DIFFUSER BACK EXTRACTOR PANEL DIFFUSER DETAIL $$AP' N.T.S. NOTE: SUPPORTS SHALL BE PLACED AT 5' -0" ON CENTER FOR DUCTS UP TO 35" AND 6' -0" FOR DUCTS UP TO 59 ", PER SMACNA RECOMENDATIONS. NOTE: / FOLLOW SMACNA DUCT f CONSTRUCTION STANDARDS (Existing/New) /New FLEXIBLE DUCT CONNECTION DETAIL. SCALE: N.T.S. DETAIL "A" AIR FLOW SPIN COLLAR FITTING WITH EXTRACTOR AND DAMPER. QUADRANT OPERATOR TO BE OUTSIDE INSULATION. PROVIDE INSULATION GUARD WHERE NECESSARY. ` SEAL JOINT WITH DUCT �C SEALER AND TAPE FIGURE 1 FIGURE 2 ITEM. DESCRIPTION 1. PICTURE FRAME MOUNTING ANGLE (2 PER DAMPER /1 PER SIDE) 2. DAMPER /SLEEVE ASSEMBLY 3. FIRE RATED WALL OR FLOOR 4. FASTENER FIRE DAMPER - DUCTMATE DETAIL. SCALE: N.T.S. MASONARY FIRE DAMPER -MODEL RUSKIN IBD2 - DETAIL. SCALE: N.T.S. 3 �n 4 MULTI BLADE OR CURTAIN TYPE DAMPER SLEEVE 1 151 SEVILLA AVENUE, SUITE 200 CORAL GABLES, FL 33134 OFFICE: (305) 442 -1188 FAX: (305) 445 -1509 VVVVW. ADCINTERNATIONAL.NET STATE OF FLORIDA RAYMUNDO FEITO, R.A. AR- 0010536 AA- CO01315 Architect • Seal/Signature Construction Documents for: \S-Qullr�11'14 P. AV at: ONE 7000 PLACE SUITE: 545 5th FLOOR 7000 SW 62nd AVENUE SOUTH MIAMI, FL 33143 Issue Date & Issue Description Drawn By Checked By 01 12/04/09 AC AR PERMIT ISSUE c� Z Z a w U a IL CO) Z 0 N w O O w Date & Delta Description Drawn By Checked By I Z 07 07 10 P &G P &G t9 REVISION PER CLIENT REQUEST Z Z Z a • W t— V w H a Client Information HEALTHCARE REALTY 2601 SW 37th AVENUE SUITE 805 MIAMI, FL 33133 OFFICE: (305) 446 -3666 Project Number 09127 CAD File Name ONE 7000 PLACE - SUITE 545 - DR.PEREZ Description MECHANICAL DETAILS Scale AS NOTED ■ ♦ ^ Consultant . Seal/Signature 7P N00MME00ffwq� U 21 SW 102 Ct. Miami, Fl. 33 Office: (786) 863 -7091 z Fax: (305) 220 -5196 Qpgengineerdesign@bellsouth.net U M=3mO W STATE OF FLORIDA ERGUIN CAPOTE P.E. No. 62487 LUIS O. PEREZ, PE P.E. No. 62586