10-649-007x� ----------------------.---------------_-------------------------------- SPECIFICATIONS FOR GENERAL CONTRACTORS PERFORMING WORK FOR HEALTHCARE REALTY ---------------------------------------------------------------------- 1. UPON COMPLETION OF THE JOB, THE CONTRACTOR WILL PROVIDE THE TENANT AND LANDLORD WITH: A. AS -BUILT PLANS. B. RELEASE OF LIENS FOR ALL SUB - CONTRACTORS. C. A FINAL RELEASE OF LIENS FROM THE GENERAL CONTRACTOR. D. THE ORIGINAL BUILDING PERMIT PLANS WITH THE ORIGINAL INSPECTOR'S SIGNATURES. 2. THE LANDLORD WILL NOT BE RESPONSIBLE FOR: A. SECURITY OF MATERIALS OF WORK IN PLACE. B. AIR CONDITIONING WORK NOT BEING PROPERLY PERFORMED TO ALLOW FOR PROPER COOLING OF THE LEASED PREMISES UNLESS ALL AIR CONDITIONING WORK IS DONE IN COORDINATION WITH THE BUILDING ENGINEERING STAFF. C. WARRANTY REPAIRS. D. WINDOW BREAKAGE DURING CONSTRUCTION. E. WORK STOPPAGES DUE TO WORK INTERFERING WITH OTHER TENANTS. F. DELAYS DUE TO CHANGE ORDERS AND ARCHITECT - CONTRACTOR PROBLEMS. G. PAYMENT OF ANY DRAW WILL BE SUBJECT TO THE LANDLORD'S AND OWNER'S REPRESENTATIVES AGREEING TO THE DEGREE OF COMPLETION. TEN PERCENT (10 %) OF EACH DRAW WILL BE HELD AS A RETAINER UNTIL THE JOB IS COMPLETED, INCLUDING PUNCH LIST ITEMS, RELEASES OF LIEN, AND ACCEPTANCE OF THE SPACE BY BOTH THE TENANT AND LANDLORD. 3. THE CONTRACTOR WILL: SECURE THE NECESSARY BUILDING PERMITS AND INSPECTIONS. INDEMNIFY AND KEEP HARMLESS THE OWNER FROM ALL LOSSES, DAMAGES, LIABILITIES, AND EXPENSES WHICH MAY ARISE OR BE CLAIMED AGAINST LANDLORD AND BE IN FAVOR OF ANY PERSONS, FIRMS, OR CORPORATIONS FOR ANY INJURIES OR DAMAGES TO THE PERSON OR PROPERTY OF ANY PERSONS, FIRMS, OR CORPORATION CONSEQUENT UPON OR ARISING FROM THE CONSTRUCTION, USE, OR OCCUPANCY OF LEASED PREMISES BY THE CONTRACTOR OR CONSEQUENT UPON OR ARISING FROM ANY ACTS, OMISSIONS, NEGLECT OR FAULT OF THE CONTRACTOR HIS AGENTS, SERVANTS, EMPLOYEES, LICENSEES, VISITORS, CUSTOMERS, PATRONS, OR INVITEES, OR CONSEQUENT UPON OR ARISING FROM THE CONTRACTOR'S FAILURE TO COMPLY WITH ANY LAWS, STATUTES, ORDINANCES, CODES, OR REGULATIONS; THAT THE OWNERS SHALL NOT BE LIABLE TO THE CONTRACTOR FOR ANY DAMAGES, LOSSES OR INJURIES TO THE PERSONS, FIRMS OR CORPORATIONS EXCEPT WHEN SUCH INJURY, LOSS, OR DAMAGE RESULTS FROM NEGLIGENCE OF THE OWNER, HIS AGENTS, OR EMPLOYEES, AND THAT THE CONTRACTOR WILL INDEMNIFY AND KEEP HARMLESS THE OWNERS AND BE IN FAVOR OF ANY PERSONS, FIRMS, OR CORPORATIONS FOR ANY INJURIES OR DAMAGES TO THE PERSON, OR THE PROPERTY OF ANY PERSONS, FIRMS OR CORPORATIONS WHERE SAID INJURIES OR DAMAGES AROSE ABOUT OR UPON THE LEASED PREMISES AS A RESULT OF THE HE NEGLIGENCE OF THE CONTRACTOR, HIS AGENTS, EMPLOYEES, SERVANTS, LICENSEES, VISITORS, CUSTOMERS, PATRONS, AND INVITEES. ALL PERSONAL PROPERTY PLACED OR MOVED INTO OR OUT OF THE BUILDING SHALL BE AT THE RISK OF THE CONTRACTOR OR THE OWNER THEREFORE AND THE OWNERS SHALL NOT BE LIABLE TOT HE CONTRACTOR FOR ANY DAMAGE TO ANY PERSONAL PROPERTY. 4. THE CONTRACTOR WILL CONFINE THE CONSTRUCTION DEBRIS AND DUST TO THE CONSTRUCTION AREA, AWAY FROM COMPLETED TENANT SPACE OR COMMON AREAS. ALL AREAS OF THE BUILDING, ESPECIALLY ACCESS AREAS AND COMMON AREAS, ARE TO BE MAINTAINED IN A CLEAN AND ORDERLY FASHION. THE CONTRACTOR IS TO TURN THE IMPROVED PREMISES OVER THE PROPERTY MANAGER IN A CLEAN CONDITION, READY FOR OCCUPANCY BY THE TENANT. 5. THE CONTRACTOR WILL REMOVE ALL TRASH AND DEBRIS, INCLUDING EXCESS MATERIALS FROM THE CONSTRUCTION SITE AND THE BUILDING AND NO UNREASONABLE ACCUMULATION BE ALLOWED. 6 THE CONTRACTOR WILL COORDINATE THE DELIVERY OF MATERIALS AND THE USE OF THE FREIGHT ELEVATOR AND REMOVAL OF DEBRIS WITH THE PROPERTY MANAGER. 7 THE CONTRACTOR IS RESPONSIBLE FOR ALL PARKING CHARGES OF HIS EMPLOYEES, SUB - CONTRACTORS, AND VENDORS. 8 THE CONTRACTOR WILL SUBMIT ALL CHANGES ORDERS TO THE LANDLORD FOR APPROVAL AND THE BLUEPRINTS ARE TO BE REVISED ACCORDINGLY. 9 . THE CONTRACTOR WILL EXERCISE ALL DUE DILIGENCE IN MAINTAINING A SAFE WORKING ENVIRONMENT AND TO ABIDE BY ALL OSHA REGULATIONS. 10. UPON COMPLETION, THE CONTRACTOR WILL REMOVE ALL FOREIGN MATERIALS FROM WINDOWS, FLOORS, GLASS, HARDWARE AND RESTROOM FIXTURES. 11. THE CONTRACTOR WILL NOT UNDULY DISTURB THE PEACEFUL ENJOYMENT OF ANY TENANTS IN THE BUILDING. ALL DRILLING THROUGH THE CONCRETE FLOOR SLAB IS TO BE SCHEDULED WITH THE PROPERTY MANAGER. ALL PLUMBING INSTALLATIONS REQUIRING ACCESS TO OTHER AREAS OF THE BUILDING WET COLUMN WILL BE COORDINATED WITH THE PROPERTY MANAGER. 12. THE CONTRACTOR WILL INSTALL CONSTRUCTION AIR CONDITIONING FILTERS IN ALL RETURN AIR DAMPERS IN THE DEMISING WALLS IN ORDER TO PREVENT CONSTRUCTION DUST FROM ENTERING THE MAIN AIR CONDITIONING SYSTEM. 13. THE CONTRACTOR IS TO PROVIDE FIVE (5) COPIES OF ALL SHOP DRAWINGS, PRODUCT INFORMATION SUBMITTALS, AND ALL OTHER SUBMITTALS REQUIRED FOR REVIEW, ETC. AT LEAST TWO (2) OF THE ABOVE COPIES SHALL BE ORIGINALS. ----------------------------------------------------------------------- GENERAL NOTES ----------------------------------------------------------------------- 1. THE CONTRACTOR SHALL VISIT THE JOB SITE AND VERIFY ALL CONDITIONS OF THE WORK PRIOR TO SUBMITTING A BID. 2. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD. DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO THE COMMENCING OF THE WORK IN THE AREA IN QUESTION. 3. ALL WORK SHALL BE DONE IN ACCORDANCE TO THE LATEST EDITION OF THE FLORIDA BUILDING CODE AND ANY APPLICABLE CODE. 4. IMPACT FEES, WATER AND SEWER CONNECTION FEES AND DEPOSITS FOR PERMANENT UTILITY SERVICES SHALL BE PAID FOR THE BY OWNER. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND /OR THE OWNER WHEN THESE FEES APPLY PRIOR TO THE START OF THE CONSTRUCTION OF THIS PROJECT. 5. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR ALL PREFABRICATED ITEMS OF THE WORK INCLUDING BUT NOT LIMITED TO THE FOLLOWING: PREFAB STAIR, WHEELCHAIR LIFT, ATM, VAULT, STOREFRONT DOORS, CABINETS, AIR CONDITIONING, ETC. THE CONTRACTOR SHALL OBTAIN THE ARCHITECT'S WRITTEN APPROVAL OF SHOP DRAWINGS PRIOR TO THEIR FABRICATION. SAMPLES SHALL BE SUBMITTED UPON REQUEST. 6. WHERE EXISTING WALLS, CEILINGS OR FIXTURES ARE REMOVED: WALLS CEILINGS AND FLOORS SHALL BE PATCHED; ELECTRIC AND PLUMBING SHALL BE CAPPED. 7. PROVIDE 1 -3 ABC RATED FIRE EXTINGUISHER PER 2500 SQ. FT.. , AND MAXIMUM INTERVALS OF 75' -0" 8. ANY ITEM OF WORK NECESSARY TO THE PROPER COMPLETION OF CONSTRUCTION WHICH IS NOT SPECIFICALLY COVERED IN THESE DOCUMENTS SHALL BE PERFORMED IN A MATTERS DEEMED GOOD PRACTICE OF THE TRADE INVOLVED. 9. ALL NEWS MATERIALS AND FINISHES SHALL MATCH EXISTING, UNLESS SPECIFIED OTHERWISE, SEE OWNER AND /OR ARCHITECT FOR APPROVAL OF ALTERNATIVES. 10. BUILDING HAS A COMPLETE FIRE SPRINKLER SYSTEM. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR THE RELOCATION AND CONDITION OF SPRINKLER HEADS. SPRINKLER HEADS SHALL BE FLUSH MOUNTED. 11. PROVIDE WATER PROOFING MEMBRANE OF ALL NEW CONCRETE SLAB ON GRADE POURS. 12. CONTRACTOR SHALL PREPARE EXISTING AND NEW FLOOR SURFACES FOR PROPER LEVELING TO RECEIVE NEW PROPOSED FLOOR FINISHES. 13. CONTRACTOR IS TO PROVIDE PROPER BACKING AND BRACING AT ALL AREAS TO RECEIVE MILLWORK CABINETS, SHELVING, ETC. 14. ALL PROPOSED MILLWORK CONSTRUCTION SHALL COMPLY WITH AWI CUSTOM STANDARDS, TYP. 15. CONTRACTOR SHALL COORDINATE AT ROUGH FRAMING PRIOR . TO INSTALLATION OF GYPSUM WALL BOARD ALL PROPOSED CONDUIT TYPES, RUNS, AND LOCATIONS W/ LE FEBURE, ADT, AND DIEBOLD. TYP. GENERAL NOTES USE AND INTERPRETATION OF THIS DRAWING 1. GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION, AIA DOCUMENT A201, ARE A PART OF A CONTRACT DOCUMENTS AS DESCRIBE USE AND INTENT OF THE DRAWINGS. THE CONTRACT DOCUMENTS INCLUDE NOT ONLY THE DRAWINGS, BUT ALSO THE OWNER - CONTRACTOR AGREEMENT, CONDITIONS OF THE CONTRACT, THE SPECIFICATIONS, ADDENDA, AND MODIFICATIONS ISSUED AFTER EXECUTION OF THE CONTRACT. THESE CONTRACT DOCUMENTS ARE COMPLEMENTARY, AND WHAT IS REQUIRED BY ANY ONE SHALL BE BINDING AS IF REQUIRED BY ALL. WORK NOT COMPLETELY DELINEATED HEREON SHALL BE CONSTRUCTED OF THE SAME MATERIALS AND DETAILED SIMILARLY AS WORK SHOWN MORE COMPLETELY ELSEWHERE IN THE CONTRACT DOCUMENTS. 2. BY USE OF THE DRAWINGS FOR CONSTRUCTION OF THE PROJECT, THE OWNER REPRESENTS THAT HE HAS REVIEWED AND APPROVED THE DRAWINGS, AND THAT THE CONSTRUCTION DOCUMENT PHASE OF THE PROJECT IS COMPLETE. THE CONTRACTOR REPRESENTS THAT HE HAS VISITED THE SITE, FAMILIARIZED HIMSELF WITH THE LOCAL CONDITIONS, VERIFIED FIELD DIMENSIONS AND CORRELATED HIS OBSERVATIONS WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. 3. THE CONTRACT SUM AND THE CONTRACT TIME MAY BE CHANGED ONLY BY CHANGE ORDER TO THE CONTRACTOR SIGNED BY THE OWNER AND THE ARCHITECT. ANY WORK PERFORMED IN VARIANCE WITH THE CONTRACT DOCUMENTS AND NOT COVERED BY THE ARCHITECT'S WRITTEN ORDER FOR A MINOR CHANGE IN THE WORK OR A CHANGE ORDER, WILL NOT BE ACCEPTED. 4. AS INSTRUMENTS OF SERVICE, ALL DRAWINGS, SPECIFICATIONS AND COPIES THEREOF FURNISHED BY THE ARCHITECT ARE HIS PROPERTY. THEY ARE TO BE USED ONLY FOR THIS PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT. CHANGES TO THE DRAWINGS MAY ONLY BE MADE BY THE ARCHITECT. ANY SUBMISSION OR DISTRIBUTION WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT MAY BE CONSTRUED AS DEROGATION OF THE ARCHITECT'S COPYRIGHT OR OTHER RESERVED RIGHTS. A. D.A. ALL WORK SHALL BE CONSTRUCTED IN ACCORDANCE WITH A.D.A. ACCESSIBILITY GUIDELINES AS SET FORTH IN THE AMERICANS WITH DISABILITIES ACT HANDBOOK. AS PUBLISHED BY THE EQUAL EMPLOYMENT OPPORTUNITY COMMISSION AND THE U.S. DEPARTMENT OF JUSTICE ON OCTOBER 1991. THE CONTRACTOR AND SUBCONTRACTORS SHALL BE RESPONSIBLE FOR THE IMPLEMENTATION OF SUCH. GENERAL NOTES AND SPECIFICATIONS: GENERAL CONDITIONS: 1. THE CONTRACTOR SHALL VISIT THE JOB SITE AND VERIFY ALL CONDITIONS OF THE WORK PRIOR TO SUBMITTING A BID. 2. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD. DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO THE COMMENCEMENT OF THE WORK IN THE AREA IN QUESTION. 3. ALL WORK SHALL BE DONE IN ACCORDANCE TO THE LATEST EDITION OF THE SOUTH FLORIDA BUILDING CODE AND ANY OTHER APPLICABLE FEDERAL, STATE, AND COUNTY CODE. 4. IMPACT FEES, WATER AND SEWER CONNECTION FEES AND DEPOSITS FOR PERMANENT UTILITY SERVICES SHALL BE PAID FOR BY THE OWNER. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND OR OWNER WHEN THESE FEES APPLY PRIOR TO THE START OF THE CONSTRUCTION OF THIS PROJECT. 5. ANY ITEM OF WORK NECESSARY TO THE PROPER COMPLETION OF CONSTRUCTION WHICH IS NOT SPECIFICALLY COVERED IN THESE DOCUMENTS SHALL BE PERFORMED IN A MATTER DEEMED GOOD PRACTICE GOOD PRACTICE OF THE TRADE INVOLVED. BURGLARY INTRUSION NOTES: 1., ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF A FORCE OF 300 LBS. APPLIED IN ANY MOVEABLE DIRECTION. 2. ALL SINGLE EXTERIOR SWING DOORS SHALL HAVE A LOCK TO BE KEY OPERATED FROM THE EXTERIOR WITH A MIN. OF 6000 POSSIBLE KEY CHANGES OR LOCKING COMBINATIONS. IF KEY -IN -THE- KNOB IS USED, THERE SHALL BE AN AUXILIARY SINGLE DEAD BOLT WITH HARDENED BOLT INSERTS. 3. SLIDING GLASS DOORS SHALL BE PROVIDED WITH SLIDING DEAD DOOR DEAD BOLTS AS A BOLT OR PIN NOT REMOVEABLE OR OPERABLE FROM THE EXTERIOR AT THE JAMB, SILL, HEAD, OR MEETING MULLIONS. THESE DOORS SHALL BE REINFORCED IN THE STRIKE AND LOCK AREA TO MAINTAIN BOLT STRENGTH EFFECTIVENESS IF NECESSARY AND SUCH DOORS SHALL HAVE NO SCREWS REMOVABLE FROM THE OUTSIDE WHICH WOULD FACILITATE READY ENTRY FROM THE OUTSIDE. 4. HINGES ON EXTERIOR OUT- SWINGING DOORS SHALL HAVE NONEXPOSED SCREWS AND NONREMOVABLE PINS. 5. JAMBS OF ALL EXTERIOR OFFSET TYPE IN- SWINGING DOORS SHALL BE RABBETTED OR OF SIMILAR FABRICATION TO PREVENT DEFEATING THE PURPOSE OF THE STRIKE AND THE INTEGRITY OF LOCKS AND LATCHES. 6. SINGLE SWINGING EXTERIOR DOORS IF WOOD, SHALL BE SOLID CORE OF NOT LESS THAN 1 3/8" THICK. 7. GLASS IN EXTERIOR DOORS SHALL COMPLY W/ THE AMERICAN NATIONAL STANDARDS INSTITUTE Z97.1. 8. VISION PANELS IN EXTERIOR DOORS, OTHER THAN GLAZING WITHIN 40" OF THE INSIDE LOCKING ACTIVATING' DEVICE OF LOCKS AND SWINGING GLASS DOORS SHALL COMPLY WITH AMERICAN NATIONAL STANDARDS INSTITUTE Z97.1. 9. SLIDING GLASS DOORS AND WINDOWS SHALL BE INSTALLED AND CONSTRUCTED SO THAT NO PANEL CAN BE LIFTED FROM THE TRACKS WHEN IN THE LOCKED POSITION AND SO AS TO COMPLY W/ THE ARCHITECTURAL ALUMINUM MANUF. ASSOC., FOR FORCED ENTRY RESISTANCE AAMA 1303.2. 10. SINGLE SWING EXTERIOR AND SWING DOORS CONNECTING LIVING AREAS W/ THE GARAGE AREAS SHALL BE SECURED W/ A LATCH AND A SINGLE DEAD BOLT W/ ONE INCH MIN. THROWS, OR A COMBINATION OF DEAD LATCH AND DEAD BOLT SETS W/ LATCH THROW A MIN. OF 1/2" AND BOLTS HAVING A MIN. THROW OF 1 INCH. DOOR SHALL BE A MIN. OF 1 3/8" THICK SOLID CORE. -------------------------------------------- GENERAL NOTES 1.1 ALL WORK SHALL BE DONE IN ACCORDANCE, WITH FLORIDA BUILDING CODE, AND ALL OTHER APPLICABLE CODES AND STANDARD. CARPENTRY AND MILLWORK: 2.1 LUMBER MUST BE SOUND, THOROUGHLY SEASONED, WELL MANUFACTURED, AND FREE FROM WARP THAT CANNOT BE CORRECTED BY BRIDGING OR NAILING. WOODWORK EXPOSED TO VIEW AT EXTERIOR OR INTERIOR OF BUILDING SHALL BE DRESSED AS PER PLANS OR AS DIRECTED BY ARCHITECT. 2.2 ALL WOOD IN CONTACT WITH MASONRY OR EXPOSED TO WEATHER SHALL BE PRESSURE TREATED. 2.3 PLYWOOD SHALL BE EXTERIOR TYPE C -D GRADE AT ALL EXTERIOR SHEATHING AND FLOOR UNDERLAYMENT. 2.4 STRUCTURAL WOOD METAL CONNECTORS SHALL CONFORM TO THE LATEST RQUIREMENTS OF THE S.F.B.C. ALL METAL EXPOSED TO WEATHER INCLUDING NAILS, FLASHING, AND DRIP EDGES SHALL BE GALVANIZED UNLESS OTHERWISE SPECIFIED. 2.5 DRYWALL CONSTRUCTION SHALL 1/2" EXCEPT AS OTHERWISE SPECIFIED IN THE DRAWINGS.. 2.6 DRYWALL IN BATHROOMS SHALL MOISTURE RESISTANT, 2.7 DRYWALL SHALL BE FIRE RATED TYPE "X ", WHERE SPECIFIED IN THE PLANS. 2.8 DRYWALL SHALL BE ERECTED AND JOINTS TAPED IN STRICT CONFORMITY OF THE MANUFACTURER. 2.9 USE METAL CORNER BEADS ON ALL INTERIOR GYPSUM BOARD CORNERS, METAL BEAD TRIM SHALL MEET THE REQUIREMENTS OF ASTM C380. DOORS AND WINDOWS: 3.1 EXTERIOR DOORS SHALL HAVE WEATHERSTRIPING INCORPORATED. 3.2 EACH DOOR SHALL BE ACURRATELY CUT, TRIMMED AND FITTED TO ITS FRAME. ALLOW CLEARANCES FOR PAINT AND FOR POSSIBLE SWELLING. 3.3 JOINTS AND SPACES AROUND WINDOWS AND EXTERIOR DOORS SHALL BE CAULKED WITH POLYSULFIDE SEALANT. JOINTS TO BE CAULKED SHALL BE DRY, FREE OF DUST, AND DIRT. 3.4 JOINTS MORE THAN 1/2- DEEP SHALL PACKED' WITH CAKUM TO 1/4" FROM SURFACE BEFORE APPLYING CAULKING. 3.5 BED METAL THRESHOLDS IN CAULKING COMPUND BEFORE INSTALLATION. 3.6 ALL CAULKING WORK SHALL BE COMPLETED BEFORE FINISH COAT OF PAINT IS APPLIED. 3.7 ALL EXTERIOR DOORS AND WINDOWS SHALL BE WATER TESTED WITH GARDEN HOSE TO CHECK FOR LEAKS. FINISH NOTES: 4.1 TILE AND OTHER FINISHES SHALL BE SELECTED' BY THE OWNER AND OR ARCHITECT, CLEARANCES SHALL BE ALLOWED FOR THE INSTALLATION OF VARIOUS THICKNESSES. 4.2 ALL PAINT SHALL BE PRIMER AND FINISH COAT,' COLOR AND TYPE SHALL BE SELECTED BY THE OWNER AND OR ARCHITECT. COLOR SWATCHES MAY REQUESTED BY ARCHITECT PRIOR TO THE EXECUTION OF THE WORK. 4.3 ALL PAINT FINISHES SHALL BE SMOOTH WITHOUT RUNS, SKIPS, SAGS, OR DEFECTS. ELECTRICAL: I, 5.1 THE DRAWINGS INDICATE LOCATION OF EQUIPMENT, RUNS AND OUTLETS DIAGRAMATICALLY. INDICATED LOCATIONS ARE ESSENTIAL TO THE OVERALL AESTHETIC CONCEPT. IN THE EVENT THAT CHANGES MUST BE MADE DUE TO DEVELOPED CONDITIONS IN THE CONSTRUCTION, THE ARCHITECT SHALL BE NOTIFIED SO THAT THE APPROPRIATE CHANGES' IN LOCATIONS BE MADE PRIOR TO INSTALLATION. !! 5.2 UNDER NO CIRCUMSTANCE IS THE SUB - CONTRACTOR TO ASSUME LOCATIONS OF EQUIPMENT, RUNS AND OUTLETS WHICH ARE EXPOSED TO VIEW. 5.3 ALL PULL AND J -BOXES ARE TO BE COMPLETELY CONCEALED. 5.4 SUB - CONTRACTORS SHALL OBTAIN THE APPROPIATE INSPECTOR' S APPROVAL / ACCEPTANCE OF THE INSTALLATION. s s BUILDING DEPT. s; I, x 4KK 151 SEVILLA AVENUE, SUITE 200 CORAL GABLES, FL 33134 OFFICE: (305) 442 -1188 FAX: (305) 445 -1509 WWW. ADCINTERNATIONAL.NET ti STATE OF FLORIDA AR= 0010536 RAYMUNDO FEITO, R.A. AA- CO01315 Architect • SeaUSignature ■ Construction Documents for: Sim 5u5 - DR at: ONE 7000 PLACE SUITE: 545 5th FLOOR 7000 SW 62nd AVENUE SOUTH MIAMI, FL 33143 I Issue Date $ Issue Description Drawn By Checked By 01 12/04/09 AC AR PERMIT ISSUE Date $ Delta Description Drawn By Checked By Client Information HEALTHCARE REALTY 2601 SW 37th AVENUE SUITE 805 MIAMI, FL 33133 OFFICE: (305) 446 -3666 Project Number 09127 CAD File Name ONE 7000 PLACE - SUITE 545 - DR.PEREZ Description GENERAL NOTES Scale 1/4"=V-0" Consultant • Seal/Signature A=02 a 3 OF 11 151 SEVILLA AVENUE, SUITE 200 CORAL GABLES, FL 33134 OFFICE: (305) 442 -1188 FAX: (305) 445 -1509 WWW. ADCINTERNATIONAL.NET ti STATE OF FLORIDA AR= 0010536 RAYMUNDO FEITO, R.A. AA- CO01315 Architect • SeaUSignature ■ Construction Documents for: Sim 5u5 - DR at: ONE 7000 PLACE SUITE: 545 5th FLOOR 7000 SW 62nd AVENUE SOUTH MIAMI, FL 33143 I Issue Date $ Issue Description Drawn By Checked By 01 12/04/09 AC AR PERMIT ISSUE Date $ Delta Description Drawn By Checked By Client Information HEALTHCARE REALTY 2601 SW 37th AVENUE SUITE 805 MIAMI, FL 33133 OFFICE: (305) 446 -3666 Project Number 09127 CAD File Name ONE 7000 PLACE - SUITE 545 - DR.PEREZ Description GENERAL NOTES Scale 1/4"=V-0" Consultant • Seal/Signature A=02 a 3 OF 11