Loading...
10-323-021NEW LIGHTING PLAN ,� Scale: 4" = V -0" LIGHTING NOTEF 1— LIGHTING FIXTURES AND SWITCHES LABELED "E" ARE EXISTING TO REMAIN, LAB�LED "RL" ARE EXISTING RELOCATED AS PART OF THIS PROJECT AND "N" ARE NEW. 2— NEW LIGHTING FIXTURES SHOWN TO BE SELECTED BY OWNER /ARCHITECT U.I.O. 3— CONNECT ALL NEW EMERGENCY LIGHTS SHOWN AHEAD OF SWITCH. 4— PROVIDE BUILT —IN OCCUPANCY SENSOR TO ALL NEW LIGHT SWITCHES INDICATED ON PLANS. �5 CONNECT TO EXISTING LIGHTING FIXTURE AS INDICATED. PROVIDE NEW #12 WIRIN IN A 1/2" COND. © CONNECT TO NEW SWITCH AS INDICATED. PROVIDE NEW #12 WIRING IN A 1/2" Ut ND. Q7 NEW EXHAUST FAN TO BE CONTROLLED BY EXISTING LIGHT SWITCH. 8— ALL LIGHTING FIXTURES IN THIS SPACE ARE CONNECTED TO EXISTING 277/480V s PANEL "PH ". CONTRACTOR TO TRACE AND VERIFY ALL EXISTING CIRCUITS TO BE USED IN THIS PROJECT PRIG TO COMMENCING WORK AND TO UPDATE EXSISTING PANEL DIRECTORY AFTER COMPLETION OF WORK. s I nn nn nn1 n NEW POWER/FIRE ALARM PLAN Scale: 4" = V -0" O Q r-RI HLU UIN.VI LV GVIv c POWER/FIRE A RM NOTES 1— RECEPTACLES AND TEL /DATA OUTLETS LABELED "E" ARE EXISTING TO REMAIN AND LABELED "N" ARE NEW. 0 CONNECT TO EXISTING RECEPTACLE AS INDICATED. PROVIDE NEW #12 WIRING IN A 1/2" COND. Q3 NEW 4.2 KW, 277V TANKLESS WATER HEATER BELOW SINK. CONNECT TO PANEL "HEAT ", SPARE CIRCUIT #24 AS INDICATED. PROVIDE NEW 1P-20 AMPS, 277V CIRCUIT BREAKER AND NEW #12 WIRING IN A 1/2" COND TO DO INSTALLATION. 4— ALL FIRE ALARM DEVICES SHOWN ARE EXISTING TO REMAIN U.I.O. A TEi: -TU -PE- GN RAT'IVE CORAL GABLES, FL 33134 OFFICE: (305) 442 -1188 °"• ,' FAX: (305) 445 -1509 �' • WWW. ADCINTERNATIONAL.NET R. - ` STATE OF FLORIDA AR- 001 -0536 - RAYMUNDO FEITO, R.A. AA —0001 15 Architect • Seal /Signature Construction Documents for: su-, r,\m.,. PfN at: ONE 7000 PLACE SUITE: PHN ,' 7th FLOOR z . 7000 SW 62nd AVENUE SOUTH MIAMI, FL 33143 Issue Date & Issue Description Drawn By Checked By 01 12/04/09 AC AR PERMIT ISSUE 02 01/13/10 AC AR PRICING SUBMITTAL C9 z E z IL a A" -N a � • z W r a client Information I g HEALTHCARE REA - - -- LTY - - - =- - -- - = -- Project Number 09148 CAD File Name ONE 7000 PLACE - SUITE PHN Description` ELECTRICAL POWER &'L°IGHTING PLANS Scale AS NOTED Consultant • Seal/Signature t ,E'NGi 1[llV G fv o� " uJ Q i ':C . < 21 SW 102 Ct. i .ti t Office: (786) 863 = pP�' Fax: (305) 220 -5196 pgengineerdesignftellsoutl ne E U =2 0 9 W I STATE OF FLORIDA WERGUIN CAPOTE P.E. No. 62487 LUIS 0. PEREZ, PE P.E. No. 62586 fisa.ibw .,qp Date 815e7ta'bescnptaon '" "'" "Drawn By Checked By • I z aayy ..yy. .. _ ZQ ..... ... yp °. ° • .... -.,. ,... , � a 7 ... . . , ._.. ..... a k•�, .; w .. — V 1 a client Information I g HEALTHCARE REA - - -- LTY - - - =- - -- - = -- Project Number 09148 CAD File Name ONE 7000 PLACE - SUITE PHN Description` ELECTRICAL POWER &'L°IGHTING PLANS Scale AS NOTED Consultant • Seal/Signature t ,E'NGi 1[llV G fv o� " uJ Q i ':C . < 21 SW 102 Ct. i .ti t Office: (786) 863 = pP�' Fax: (305) 220 -5196 pgengineerdesignftellsoutl ne E U =2 0 9 W I STATE OF FLORIDA WERGUIN CAPOTE P.E. No. 62487 LUIS 0. PEREZ, PE P.E. No. 62586