10-323-0207TH FLOOR PARTIAL FLOOR PLAN .. 1 rl 1 iJ ii (D 1 OR 2 —HOUR FIRE RATED GYPSUM WALLBOARD /STUD ASSEMBLY. Q STEEL SLEEVE. SCH 40(OR HEAVIER) STEEL PIPE WITH LENGTH AS SAME AS FLOOR /WALL THICKNESS PLUS 1 TO 4 IN. ® A) STEEL PIPE — 6" DIA. (OR SMALLER) SCH. 40 (OR HEAVIER) STEEL B) CONDUIT — 4" DIAM. (OR SMALLER) EMT OR RIGID STEEL. ® COMPLETELY FILL ANNULAR SPACE AND THICKNESS OF FLOOR OR WALL WITH FYRE— SHIELD. FILL MATERIAL SHALL BE DOMED ON BOTH SIDES OF ASSEMBLY TO A 1/2" HEIGHT IN ADDITION TO THICKNESS REQUIRED FOR OPENING. • SINGLE METAL PIPE THRU ONE, TWO HOUR GYPSUM WALLBOARD /STUD ASSEMBLY RATED WALL N.T.S DETAIL GENERAL NOTES 1— INSTALLATION SHALL BE DONE IN STRICT ACCORDANCE WITH THE FLORIDA BUILDING CODE 2007 AND NEC 2008. 2— ALL CONDUCTORS SHALL BE COPPER, THWN TYPE RATED AT 750C. 3— ALL CONDUITS SHALL BE E.M.T. UNLESS INDICATED OTHERWISE. 4— ALL RECEPTACLES AND LIGHT SWITCHES SHALL HAVE AN ENGRAVED BRANCH CIRCUIT IDENTIFICATION PLATE INDICATING PANEL AND CIRCUIT NUMBER. 5— PROVIDE TYPED CIRCUIT INDEX FOR ALL NEW AND EXISTING PANELBOARDS. 6— PROVIDE ALL REQUIRED PERMITS AND PAY ALL FEES, 7— ALL BOXES SHALL BE METALLIC. 8— ALL RECEPTACLES SHALL BE 18" A.F.F. UNLESS INDICATED OTHERWISE. 9— PROVIDE A GREEN GRD. WIRE TO ALL RECEPTACLES, AND FIXED EQUIPMENT, 10— CONTRACTOR MUST VISIT SITE TO BECOME FAMILIAR WITH EXISTING CONDITIONS BEFORE BIDDING THIS JOB. 11— CONTRACTOR SHALL INSTALL ALL ELECTRICAL EQUIPMENT FURNISHED BY THE OWNER OR OTHER CONTRACTOR. 12— ALL CONDUITS SHALL RUN CONCEALED U.I.O. 13— PROVIDE COVER PLATES FOR ALL OUTLETS. 14— ALL CONDUIT PENETRATIONS OF FIRE —RATED WALLS, FLOORS, AND CEILINGS SHALL BE SEALED IN ACCORDANCE WITH REQUIREMENTS OF NEC ARTICLE 300 -21 AND DETAILS I AND II ON THIS SHEET. 15— PROVIDE ALL THE REQUIRED WIRING AND CONDUIT. 16— FOR ALL DISCONNECTS PROVIDE NEMA 1 ENCLOSURE INDOORS AND NEMA 3R ENCLOSURE OUTDOOR. 17— ALL ELECTRICAL SWITCHES SHALL BE 48" A.F.F. UNLESS INDICATED OTHERWISE. 18— ALL LIGHT SWITCHES SHALL HAVE AN ENGRAVED BRANCH CIRCUIT IDENTIFICATION PLATE INDICATING PANEL AND CIRCUIT NUMBER. 19— COORDINATE MOUNTING HEIGHT OF ALL LIGHTING FIXTURES WITH ARCHITECT. 20— SHEETS WITH NOTES IN HEXAGON ARE FOR SPECIFIC LOCATIONS. NOTES WITHOUT HEXAGON ARE GENERAL NOTES FOR THAT SHEET. 21— ALL FLUORESCENT FIXTURES SHALL USE ENERGY CONSERVATION BALLAST AND LAMPS LAMPS (GE OR SYLVANIA) 22— ALL CONDUITS RUNNING UNDERGROUND BE PVC SCHEDULE 40 1" MINIMUM. 23— ALL CONDUITS RUNNING EXPOSED IN EXTERIOR AREAS UP TO 8' -0" HIGH TO BE RIGID METALLIC CONDUIT. 24— ALL CONDUITS RUNNING CONCELEAD TO BE EMT TYPE. gnzi� NI I SYMBOL I DESCRIPTION I FLUORESCENT LIGHTING FIXTURE CEILING MTD IN NORMAL POWER. TYPE AS SPECIFIED. FLUORESCENT DOWNLIGHT CEILING MTD. TYPE AS SPECIFIED. �} CEILING /WALL MTD. EXIT LIGHT. CEILING /WALL MTD. EMERGENCY LIGHT. TELEPHONE OUTLET MTD 18" AFF.,U.1.0 DATA OUTLET MTD. 18" A.F.F.,U.1.0 FIRE ALARM SYSTEM PHOTOELECTRIC SMOKE DETECTOR ADDRESSABLE TYPE. FIRE ALARM SYSTEM COMBINATION HORN /STROBE LIGHT (75 Cd) OF . AVT 80" MEASURED FROM FINISHED FLOOR TO BOTTvON FIRE ALARM SYSTEM STROBE LIGHT �75 Cd) MTD. AT 80" MEASURED FROM FINISHED FLOOR TO BOTTON F DEVICE. I NOTE: ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED FOR THIS PROJECT. I 151 SEVILLA AVENUE, SUITE 200 CORAL GABLES, FL 33134 OFFICE: (305) 442 -1188 FAX: (305) 445 -1509 WWW. ADCINTERNATIONAL.NET STATE OF FLORIDA AR- 0010536 RAYMUNDO FEITO, R.A. AA- CO01315 Architect • Seal/Signature Construction Documents for: S1 PHN at: ONE 7000 PLACE SUITE: PHN 7th FLOOR 7000 SW 62nd AVENUE SOUTH MIAMI, FL 33143 11ssue Date 8 Issue Description Drawn By Checked By 01 12/04/09 AC AR PERMIT ISSUE C7 z z a W Q IL • C9 N W O F2 UJ i. Date A Delta Description Drawn By Checked By z i z E z IL LU I- V H V Q Client Information HEALTHCARE REALTY 2601 SW 37th AVENUE SUITE 805 MIAMI, FL 33133 OFFICE: (305) 446 -3666 Project Number 09148 CAD File Name ONE 7000 PLACE - SUITE PHN Description ELECTRICAL GENERAL NOTES & DETAILS Scale AS NOTED Consultant Seal/Signature 1 E' F • 21 SW 102 • :. 863-70 1 220-5196 •gengineerdesign@beRsouth.net E=1 mO STATE OF •- D• -• LUIS • • 62586 20A, 1201277VAC SINGLE POLE TOGGLE SWITCH, SPECIFICATION GRADE 4' -0" A. F. $3 THREE WAY SWITCH, SAME AS ABOVE 20A, 125V, 3 WIRE GROUNDING TYPE SPECIFICATION GRADE DUPLEX RECEPTACLE, MTD. 18" A.F.F., U.I.O. 20 A. 125V. 3 WIRES GROUND TYPE SPECIFICATION GRADE QUADRUPLEX RECEPT. MTD. 18" A.F.F., U.I.O. 20A, 125V, 3 WIRE GROUND FAULT INTERRUPTER DUPLEX RECEPTACLE, 6" ABOVE COUNTERS OR 42" A.F.F., U.I.O. MOTOR, NUMBER IN CIRCLE DENOTES HORSE POWER RATING DI /I-Q CEILING OR WALL MTD. JUNCTION BOX SURFACE WALL MTD. PANELBOARD FLUSH MTD. PANELBOARD 3 30 E— SAFETY DISCONNECT SWITCH, 30= SWITCH SIZE, 3 =No. OF POLES, 15 LuJ �� 15 =FUSE SIZE, O =NON FUSED I NOTE: ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED FOR THIS PROJECT. I 151 SEVILLA AVENUE, SUITE 200 CORAL GABLES, FL 33134 OFFICE: (305) 442 -1188 FAX: (305) 445 -1509 WWW. ADCINTERNATIONAL.NET STATE OF FLORIDA AR- 0010536 RAYMUNDO FEITO, R.A. AA- CO01315 Architect • Seal/Signature Construction Documents for: S1 PHN at: ONE 7000 PLACE SUITE: PHN 7th FLOOR 7000 SW 62nd AVENUE SOUTH MIAMI, FL 33143 11ssue Date 8 Issue Description Drawn By Checked By 01 12/04/09 AC AR PERMIT ISSUE C7 z z a W Q IL • C9 N W O F2 UJ i. Date A Delta Description Drawn By Checked By z i z E z IL LU I- V H V Q Client Information HEALTHCARE REALTY 2601 SW 37th AVENUE SUITE 805 MIAMI, FL 33133 OFFICE: (305) 446 -3666 Project Number 09148 CAD File Name ONE 7000 PLACE - SUITE PHN Description ELECTRICAL GENERAL NOTES & DETAILS Scale AS NOTED Consultant Seal/Signature 1 E' F • 21 SW 102 • :. 863-70 1 220-5196 •gengineerdesign@beRsouth.net E=1 mO STATE OF •- D• -• LUIS • • 62586