10-323-019System No. C -AJ -2419 F Rating - 3 Hr T Rating - 0 Hr 1. Floor or Wall Assembly -- Min 4-1/2 in. thick reinforced lightweight or normal weight (100 -150 pcf) concrete floor or min 5 in. thick reinforced lightweight or normal weight 100 -150 concrete wall. Wall m also be constructed of a UL 9 ( P� may any Classed Concrete Blocks*. Max diam of opening shall be 6 in. See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manufacturers. 2. Through Penetrants -- One nonmetallic penetrant centered within the firestop system. The annular space between pipe and periphery of opening shall be nom 3/4 in. Pipe to be rigidly supported on both sides of the floor assembly. The following types and saes of non - metallic pipe may be used: A Polyvinyl Chloride (PVC) Pipe -- Nom 4 in. dam (or smaller) Schedule 40 solid core or cellular core PVC pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. B. Chlorinated Polyvinyl Chloride (CPVC) pipe - Nom 4 in. diam (or smaller) SDR 13.5 CPVC pipe for use in closed (process or supply) piping systems. C. Acrylonitrile Butadiene Styrene (ABS) Pipe -- Nom 4 in. diam (or smaller) Schedule 40 solid core or cellular core ABS pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. 3. Firestop System -- The details of the firestop system shall be as follows: A. Fill, Void or Cavity Material* - Wrap Strip -- Nom 3/16 in. thick by 1 -3/4 in. wide intumescent wrap strip. The wrap strip is continuously wrapped around the outer circumference of the pipe covering two times and slid into the annular space. When multiple wrap strips are used to achieve the required total length, the ends are to be butted end to end and held in place with tape. The bottom edge of the wrap strip shall be recessed 1/2 in. from the bottom surface of the concrete floor. In walls, the wrap shall be installed on both surfaces of the wall such that the exposed edge of the wrap strip is recessed 1/2 in. from each side of the wall. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC -- CP 648 -E- W45/1 -3/4' Wrap Strip B. FIT, Void or Cavity Materials* - Sealant -- Min 1/2 in. thickness of fill material applied within the annulus, flush with bottom surface of floor or both surfaces of wall. HILT] CONSTRUCTION CHEMICALS, DIV OF HILTI INC -- FS ONE Sealant *Bearing the UL Classification Mark P � ®m Reproduced by HILTI, Inc Courtesy of V�'SS lF�ec� Underwriters Laboratories, Inc. �? FIRESTOP SYSTEMS Apn127, 2005 C m US r System No. C -AJ -2271 r F Rating - 2 Hr T Rating -1 Hr A W Rating - Class 1(See Item 3) 1. Floor or Wall Assembly - Min 2 -1/2 in. (64 mm) thick reinforced lightweight or normal weight (100 -150 pd or 1600 -2400 kgtm3) concrete. Wall may also be constructed of any UL Classified Concrete Blocks'. Max diam of opening is 7 in. (178 mm). See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manufacturers. 2. Through Penetrants - One nonmetallic pipe or conduit to be installed concentrically or eccentrically within the firestop system. Annular space between pipe or conduit and edge of opening to be min 0 in. (0 mm, point contact) and max 1/2 in. (13 mm). Pipe or conduit to be rigidly supported on both sides of floor - ceiling assembly. The following types and sizes of nonmetallic pipes or conduits may be used: A Polyvinyl Chloride (PVC) Pipe - Nom 6 in. (152 mm) diam (or smaller) Schedule 40 solid or cellular core PVC pipe for use in dosed (process or supply) or vented (drain, waste or vent) piping systems. B. Chlorinated Polyvinyl Chloride (CPVC) Pipe - Nom 6 in. (152 mm) diam (or smaller) SDR13.5 CPVC pipe for use in dosed (process or supply) piping systems. C. Acrylonitrile Butadiene Styrene (ABS) Pipe - Nom 6 in. (152 mm) diam (or smaller) Schedule 40 solid or cellular core ABS pipe for use in dosed (process or supply) or vented (drain, waste or vent) piping systems. D. Flame Retardant Polypropylene (FRPP) Pipe - Nom 6 in. (152 mm) diam (or smaller) Schedule 40 FRPP pipe for use in dosed (process or supply) or vented (drain, waste or vent) piping systems. 3. Fill, Void or Cavity Materials* - Sealant- Required for systems with W Rating, but otherwise optional. Min 1/2 in. (13 mm) thickness of fill material applied within the annulus, flush with top or bottom surface of floor. W Rating applies only when CP601 S or CP 604 Sealant is used. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC- FS-ONE Sealant, CP 601S Sealant or CP 604 Sealant 3A Packing Material (not shown) - Min 1/2 in. (13 mm) thickness of 4 pcf (64 kglm3) mineral wool batt insulation firmly packed into annular space and recessed from the top surface of floor to accommodate the required thickness of fill material. Required only when CP 604 Sealant is used. 4. Firestop Device*- Firestop Collar- Firestop collar shall be installed in accordance with the accompanying installation instructions. Collar to be installed and latched around the pipe and secured to underside of floor or both sides of wall using anchor hooks provided with the collar. Minimum two anchor hooks required for non 1 -1/2 and 2 in. (38 and 51 mm) diam pipes. Minimum three anchor hooks required for nom 3 and 4 in. (76 and 102 mm) diam pipes. Minimum four anchor hooks required for 6 in. (152 mm) diam pipes. The anchor hooks are to be secured with min 114 in. (6 mm) diam by min 1 -1/4 in. (32 mm) long steel expansion bolts or min 0.145 in. (3.7 mm) diam by 1 -1/4 in. (32 mm) long powder actuated fasteners utilizing a 1 -7/16 in. (37 mm) diam by 1/16 in. (1.6 mm) thick steel washer. As alternates to the anchors specified above, Hilt! 1/4 in. (6 mm) diam by 1 -1/4 in. (32 mm) long KWIK -CON II+ concrete screw anchor, Hilt 1/4 in. (6 mm) diam by 1 -3/4 in. (45 mm) long KWIK -BOLT 3 steel expansion anchor or Hilti X-DNI 27 P8 S15 powder actuated floor pin with integral nom 9/16 in. (15 mm) diam washer may be used. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC - CP 643 50/1.5 -N, CP 643 63aW, CP 643 9313'N, CP 643 9014% and CP643 16016 "N. Firestop Collar *Bearing the UL Classification Mark S ►F/ ELM Reproduced by HILTI, Inc. Courtesy of V Underwriters Laboratories, Inc. Hilt! Firestop Systems November 18,2006 m System No. W -L -2284 F Rating -1 Hr T Rating -1 Hr a N 3 SECTION A -A 1. Wall Assembly -- The 1 hr fire -rated gypsum board /stud wall assembly shall be constructed of the materials and in the manner specked in the individual 0300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A Studs -- Wall framing shall consist of wood studs or steel channel studs. Wood studs to consist of 2 by 4 in. lumber spaced 16 in. OC. Steel studs to be min 3 -1/2 in. wide and spaced max 24 in. OC. B. Gypsum Board* -- Min 5/8 in. thick, 4 ft wide with square or tapered edges. The gypsum wallboard type, thickness, number of layers and orientation shall be as specified in the individual U300 or U400 Wall and Partition Design. Max diam of opening is 4 in. -- nonmetallic i to be centered within the firestop em. An annular space of 3 16 to 1 4 in. 2. Through Penetrants One nonmet Pipe p syst Pa / / is required within the firestop system. Pipe to be rigidly supported on both sides of wall assembly. The following types and sizes of nonmetallic pipes may be used: A Polyvinyl Chloride (PVC) Pipe - Nom 3 in. diam (or smaller) Schedule 40 solid or cellular core PVC pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. B. Chlorinated Polyvinyl Chloride (CPVC) Pipe -- Nom 3 in. diam (or smaller) SDR 13.5 CPVC pipe for use in closed (process or supply) piping systems. 3. Fill, Void or Cavity Material* -- Wrap Strip - Layers of intumescent wrap strip are continuously wrapped around the pipe with ends held in place with tape. Wrap strip installed such that ends protrude nom. 1/8 in. beyond both surfaces of wall. Size of wrap strip and number of layers are shown in table below. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC -- CP648 -E W25/1' or CP648 -E W45/1 -3/4' Frestop Wrap Strip ProdudDesignation Pipe Number of Nom. Wrap Strip SYMBOL Diameter (in.) Layers Width (n.) CP648- E- W2511' 1 -112 and 2 1 1 CP648- E -W45/1 -314° 1 -112, 2 and 3 1 1 -3/4 A. Fill, Void or Cavity Material* - Wrap Strip -- (As an aftemate to the wrap strip in Item 3) - One layer of intumescent wrap strip is tightly wrapped around the pipe with ends butted and held in place with integrated tape. Wrap strip installed such that ends protrude nom. 1/8 in. beyond both surfaces of wall. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC -- CP648- S -1.5' US, CP648 -S -2' US, CP648 -S -3' US *Bearing the UL Classification Mark L= ;J Reproduced Laboratories, Inc. of FIRESTOP SYSTEMS Apnl22•2005 C US System No. F -A -2089 0 F Rating - 3 Hr a T Rating - 0 Hr W Rating - Class 1(See Item 3B) 2 1 313 44. t A A 3A SECTION A -A 1. Floor Assembly - Min 2 -1/2 in. thick reinforced lightweight or normal weight (100.150 pd) concrete. Max diameter of opening is 5 in. 1A. Floor AssemblygOptional - Not Shown) - The fire rated unprotected concrete and steel floor assembly shall be constructed of the materials and in the manner specified in the individual D900 Series designs in the Fire Resistance Directory and as summarizes below: A Concrete - Min 2 -1/2 in. thick reinforced lightweight or normal weight (100 -150 pd) concrete. B. Steel Floor and Form Units* - Composite or non-composite max 3 in. deep gale steel fluted units as specified in the individual Floor- Ceiling Design. 2. Through Penetrants - One nonmetallic pipe to be installed concentrically or eccentrically within the firestop system. Annular space within the firestop system is dependent upon the diam and type of penetrant used as tabulated in Item 3A. Pipe to be rigidly supported on both sides of floor or wall assembly. The following types and sizes of nonmetallic pipes may be used: A Polyvinyl Chloride (PVC) Pipe - Nom 3 in. diam (or smaller) Schedule 40 solid or cellular core PVC for use in dosed (process or supply) or vented (drain, waste or vent) piping systems. B. Chlorinated Polyvinyl Chloride (CPVC) Pipe - Nom 3 in. diam (or smaller) SDR13.5 CPVC for use in dosed (process or supply) piping systems. C. Acrylonitrile Butadiene Styrene (ABS) Pipe - Nom 3 in. diam (or smaller) Schedule 40 solid or cellular core PVC for use in dosed (process or supply) or vented (drain, waste or vent) piping systems. D. Flame Retardant Polypropylene (FRPP) Pipe - Nom 3 in. diam (or smaller) Schedule 40 FRPP pipe for use in dosed (process or supply) or vented (drain, waste or vent) piping system. 3. Firestop System - The firestop system shall consist of the following: A Fill, Void or Cavity Material` -Wrap Strip - Nom 3116 in. thick by 1-314 in. wide intumescent wrap strip. The layers of wrap strip are continuously wrapped tightly around pipe with ends held in place with tape. Wrap strip installed recessed % in. from bottom surface of concrete cover. The max diam of opening, max diam and type of penetrant, annular space within the firestop system and layers of wrap strip required are tabulated below: HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC - CP648 -E W4511 -314' Wrap Strip B. Fill, Void or Cavity Materials•- Sealant - Min 1/4 in. thickness of fill material applied within the annulus directly on top of wrap strip, flush with top surface of floor. W Rating applies only when CP 601 S Sealant is used. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC- FS-ONE Sealant or CP 601S Sealant *Bearing the UL Classification Mark S IF/ Reproduced by HILTI, Inc. Courtesy of VI tom► Underwriters Laboratories, Inc. m Hilti Firestop Systems October 06, 2005 1 PLUMBING FIRE PENETRATION DETAILS Scale: NTS PRINTED ON: 12-07-2009 System No. C -AJ -1226 N F RATING = MR. :y T RATING = MR ! L Rating At Ambient - Less than 1 CFM/Sq Ft L Rating At 400 F -4 CFWSq Ft 3 4B F_ A 2 4B 1 i 3 A 4A SECTION A -A 1. Floor or Wall Assembly -- Min 4 -1/2 in. thick reinforced lightweight or normal weight (100 -150 pcf) concrete. Wall may also be constructed of any UL Classified Concrete Blocks*. Max diam of opening is 32 in. 2. Metallic Sleeve -- (Optional) Nom 32 in. diam (or smaller) Schedule 40 (or heavier) steel sleeve cast or grouted into floor or wall assembly, flush with floor or wall surfaces or extending a max of 3 in. above floor or beyond both surfaces of wall. 3. Through - Penetrant -- One metallic pipe, tube or conduit to be installed either concentrically or eccentrically within the firestop system. The annular space between penetrant and periphery of opening shall be min 0 in. (point contact) to max 1 -7/8 in. Penetrant may be installed with continuous point contact. Penetrant to be rigidly supported on both sides of floor or wall assembly. The following types and saes of metallic penetrants may be used: A. Steel Pipe -- Nom 30 in. dam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe -- Nom 30 in. dam (or smaller) cast or ductile iron pipe. C. Copper Pipe -- Nom 6 in. dam (or smaller) Regular (or heavier) copper pipe. D. Copper Tubing -- Nom 6 in. diam (or smaller) Type L (or heavier) copper tubing. E Conduit -- Nom 6 in. d conduit am (or smaller) steel cond F. Conduit - Nom 4 in. dam (or smaller) steel electrical metallic tubing 4. Firestop System -- The fmstop system shall consist of the following: A. Packing Material -- Min 4 in. thickness of min 4 pcf mineral wool butt insulation firmly packed into opening as a permanent form. Packing material to be recessed from top surface of floor or sleeve or from both surfaces of wall or sleeve as required to accommodate the required thickness of fill material B. Fill, Void or Cavity Material* -- Sealant -- Min 1/4 in. thickness of fill material applied within the annulus, flush with top surface of floor or sleeve or with both surfaces of wall or sleeve. At the point or continuous contact locations between penetrant and concrete or sleeve, a min 1/4 in. diam bead of fill material shall be applied at the concrete or sleeve/ pipe penetrant interface on the top surface of floor and on both surfaces of wall. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC -- FS -One Sealant *Bearing the UL Classification Mark M�_M LJ-- iJ�L���• hKodutmil undowdti s� tiLat � d /� FIRESn7P SYSTEMS October 30. 2003 C U$ Page: t of t System No. C -AJ -2342 N F Rating - 3 Hr a T Rating - 0 Hr W Rating - Class 1 (See Item 3B) 2 3B 1 A A 3A SECTION A -A 1. Floor or Wall Assembly- Min 2 -1/2 in. (64 mm) thick reinforced lightweight or normal weight (100 -150 pd or 1600 -2400 kg/m3) concrete floor or wall. Wall may also be constructed of any UL Classified Concrete Blocks *. Max diam of opening is 6 in. See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manufacturers. 2. Through Penetrants - One nonmetallic pipe to be installed concentrically or eccentrically within the firestop system. Annular space within the firestop system is dependent upon the max diam and type of penetrant used as tabulated in Item 3A Pipe to be rigidly supported on both sides of floor or wall assembly. The following types and sizes of nonmetallic pipes may be used: A. Polyvinyl Chloride (PVC) Pipe - Nom 4 in. (102 mm) diam (or smaller) Schedule 40 solid or cellular core PVC for use in dosed (process or supply) or vented (drain, waste or vent) piping systems. i B. Chlorinated Polyvinyl Chloride (CPVC) Pipe - Nom 4 in. (102 mm) diam (or smaller) SDR13.5 CPVC for use in dosed (process or supply) piping ly) P P 9 systems. C. Acrylonitrile Butadiene Styrene (ABS) Pipe - Nom 4 in. (102 mm) diam (or smaller) Schedule 40 solid or cellular core ABS for use in dosed (process or supply) or vented (drain, waste or vent) piping systems. D. Flame Retardant Polypropylene (FRPP) Pipe - Nam 4 in. (102 mm) diam (or smaller) Schedule 40 FRPP pipe for use in dosed (process or supply) or vented (drain, waste or vent) piping system. 3. Firestop System - The firestop system shall consist of the following: A Fill, Void or Cavity Material* - Wrap Strip - Layers of intumescent wrap strip are continuously wrapped around the pipe with ends held in place with tape. Wrap strip installed recessed max 1/4 in. (6 mm) from bottom surface of floor or from both surfaces of wall. Size of wrap strip and number of layers for a given size penetrant are shown in table below: HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC - CP648 -E W2511' or CP648 -E W4511 -3/4" Firestop Wrap Strip Reproduced by HILTI, Inc. Courtesy of V S 1 Fj� Underwriters Laboratories, Inc. Hilti Firestop Systems August2g,2007 e, P Y Page- 1 of 2 A-7 A---J System No. W -L -1290 N F Rating -1 and 2 Hr (See Item 1) 3 T Rating - 0 Hr L Rating at Ambient - Less than 1 CFM /Sq Ft L Rating at 400° F - Less than 1 CFM /Sq Ft 1. Wall Assembly -- The 1 or 2 hr fire rated gypsum board /stud wall assembly shall be constructed of the materials and in the manner specified in the individual 0300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features. A Studs -- The 1 or 2 hr fire rated gypsum board /stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features. B. Gypsum Board * - -- Nom 5/8 in. thick, 4 ft wide with square or tapered edges. The gypsum board type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U300 or U400 Series Design in the Fire Resistance Directory. Max dam of opening is 5 in. The hourly F and T Ratings of the firestop system are equal to the hourly fire rating of the wall assembly in which it is installed. 2. Through Penetrant -- One metallic pipe, conduit or tubing installed concentrically or eccentrically within the firestop system. Pipe, conduit or tubing may be installed at an angle not greater than 45 degrees from perpendicular. Pipe, conduit or tube to be rigidly supported on both sides of wall assembly. The annular space between the pipe or tube and periphery of the opening shall be min 0 in (point contact) to max 1/2 in. The following types and sizes of metallic pipes, conduit or tube may be used: A Steel Pipe -- Nom 4 in. diam (or smaller) Schedule 40 (or heavier) steel pipe. B. Iron Pipe -- Nom 4 in. dam (or smaller) cast or ductile iron pipe. C. Conduit -- Nom 4 in. dam (or smaller) steel electrical metallic tubing (EMT) or steel conduit D. Copper Tube -- Nom 4 in. dam (or smaller) Type L (or heavier) copper tube. E. Copper Pipe -- Nom 4 in. dam (or smaller) Regular (or heavier) copper pipe. 3. Fill, Void or Cavity Material * - Sealant -- Min 5/8 in. thickness of fill material applied within the annulus, flush with both surfaces of wall. At the point contact location between pipe and wall, a min % in dam bead of fill material shall be applied at the pipe /wall interface. HILTI CONSTRUCTION CHEMCIALS, DIV OF HILTI INC -- CP606 Flexible Firestop Sealant *Bearing the UL Classification Mark Reproduced by HILTI, Inc. Courtesy of Ic,v l FVFp Unden!writers Laboratories, Inc. FIRESTOP SYSTEMS .tune 03, 2005 C US System No. C -AJ -2342 F Rating - 3 Hr 'a T Rating - 0 Hr W Rating - Class 1 (See Item 3B) Product Designation Pipe Size in. (mm) Max Opening Diam (in.) PLUMBING SYMBOL LEGEND Nom Wrap Strip Width in. (mm) CP648 -E W2511' 11/2(38) 3(76) 3/16 (4.8) 15/16 (24) GATE - VALVE 1(25) CP648 -E W4511 -314" SYMBOL DESCRIPTION SYMBOL DESCRIPTION 1 13/4 (45) � VENT THRU ROOF (VTR) 31/2(89) SANITARY PIPE CW COLD WATER PIPE 'Id P -TRH 2 (51) 31/2(89) 3/16(4.8) 15116 (24) 1 1314 (45) CP648 -E W4511 -314' 3 (76) 4 (102) PIPING TURNING UP 15116 (24) 1 1314 (45) CP648 -E W45/1 -314' 3 (76) WATER HAMMER (SHOCK) 318 (10) 1 1/16(27) ----- - - - - -- VENT PIPE HW HOT WATER PIPE 6 (152) ARRESTOR. 11/8(29)1 PIPING TURNING DOWN - COLD WATER PIPE CONNECT TO EXISTING CO WALL CLEAN OUTS -- HOT WATER PIPE F.F. FIRST FLOOR FD FLOOR DRAIN UG UNDERGROUND S.F. SECOND FLOOR CD CONDENSATE DRAIN PIPE FU FIXTURE UNITS DCV DOUBLE CHECK VALVE FW FILTERED WATER BACKFLOWPREVENTER; CA COMPRESSOR SYSTEM PIPING VA VACUUM SYSTEM PIPING ® FLOOR CLEAN -OUT 1 PLUMBING FIRE PENETRATION DETAILS Scale: NTS PRINTED ON: 12-07-2009 System No. C -AJ -1226 N F RATING = MR. :y T RATING = MR ! L Rating At Ambient - Less than 1 CFM/Sq Ft L Rating At 400 F -4 CFWSq Ft 3 4B F_ A 2 4B 1 i 3 A 4A SECTION A -A 1. Floor or Wall Assembly -- Min 4 -1/2 in. thick reinforced lightweight or normal weight (100 -150 pcf) concrete. Wall may also be constructed of any UL Classified Concrete Blocks*. Max diam of opening is 32 in. 2. Metallic Sleeve -- (Optional) Nom 32 in. diam (or smaller) Schedule 40 (or heavier) steel sleeve cast or grouted into floor or wall assembly, flush with floor or wall surfaces or extending a max of 3 in. above floor or beyond both surfaces of wall. 3. Through - Penetrant -- One metallic pipe, tube or conduit to be installed either concentrically or eccentrically within the firestop system. The annular space between penetrant and periphery of opening shall be min 0 in. (point contact) to max 1 -7/8 in. Penetrant may be installed with continuous point contact. Penetrant to be rigidly supported on both sides of floor or wall assembly. The following types and saes of metallic penetrants may be used: A. Steel Pipe -- Nom 30 in. dam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe -- Nom 30 in. dam (or smaller) cast or ductile iron pipe. C. Copper Pipe -- Nom 6 in. dam (or smaller) Regular (or heavier) copper pipe. D. Copper Tubing -- Nom 6 in. diam (or smaller) Type L (or heavier) copper tubing. E Conduit -- Nom 6 in. d conduit am (or smaller) steel cond F. Conduit - Nom 4 in. dam (or smaller) steel electrical metallic tubing 4. Firestop System -- The fmstop system shall consist of the following: A. Packing Material -- Min 4 in. thickness of min 4 pcf mineral wool butt insulation firmly packed into opening as a permanent form. Packing material to be recessed from top surface of floor or sleeve or from both surfaces of wall or sleeve as required to accommodate the required thickness of fill material B. Fill, Void or Cavity Material* -- Sealant -- Min 1/4 in. thickness of fill material applied within the annulus, flush with top surface of floor or sleeve or with both surfaces of wall or sleeve. At the point or continuous contact locations between penetrant and concrete or sleeve, a min 1/4 in. diam bead of fill material shall be applied at the concrete or sleeve/ pipe penetrant interface on the top surface of floor and on both surfaces of wall. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC -- FS -One Sealant *Bearing the UL Classification Mark M�_M LJ-- iJ�L���• hKodutmil undowdti s� tiLat � d /� FIRESn7P SYSTEMS October 30. 2003 C U$ Page: t of t System No. C -AJ -2342 N F Rating - 3 Hr a T Rating - 0 Hr W Rating - Class 1 (See Item 3B) 2 3B 1 A A 3A SECTION A -A 1. Floor or Wall Assembly- Min 2 -1/2 in. (64 mm) thick reinforced lightweight or normal weight (100 -150 pd or 1600 -2400 kg/m3) concrete floor or wall. Wall may also be constructed of any UL Classified Concrete Blocks *. Max diam of opening is 6 in. See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manufacturers. 2. Through Penetrants - One nonmetallic pipe to be installed concentrically or eccentrically within the firestop system. Annular space within the firestop system is dependent upon the max diam and type of penetrant used as tabulated in Item 3A Pipe to be rigidly supported on both sides of floor or wall assembly. The following types and sizes of nonmetallic pipes may be used: A. Polyvinyl Chloride (PVC) Pipe - Nom 4 in. (102 mm) diam (or smaller) Schedule 40 solid or cellular core PVC for use in dosed (process or supply) or vented (drain, waste or vent) piping systems. i B. Chlorinated Polyvinyl Chloride (CPVC) Pipe - Nom 4 in. (102 mm) diam (or smaller) SDR13.5 CPVC for use in dosed (process or supply) piping ly) P P 9 systems. C. Acrylonitrile Butadiene Styrene (ABS) Pipe - Nom 4 in. (102 mm) diam (or smaller) Schedule 40 solid or cellular core ABS for use in dosed (process or supply) or vented (drain, waste or vent) piping systems. D. Flame Retardant Polypropylene (FRPP) Pipe - Nam 4 in. (102 mm) diam (or smaller) Schedule 40 FRPP pipe for use in dosed (process or supply) or vented (drain, waste or vent) piping system. 3. Firestop System - The firestop system shall consist of the following: A Fill, Void or Cavity Material* - Wrap Strip - Layers of intumescent wrap strip are continuously wrapped around the pipe with ends held in place with tape. Wrap strip installed recessed max 1/4 in. (6 mm) from bottom surface of floor or from both surfaces of wall. Size of wrap strip and number of layers for a given size penetrant are shown in table below: HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC - CP648 -E W2511' or CP648 -E W4511 -3/4" Firestop Wrap Strip Reproduced by HILTI, Inc. Courtesy of V S 1 Fj� Underwriters Laboratories, Inc. Hilti Firestop Systems August2g,2007 e, P Y Page- 1 of 2 A-7 A---J System No. W -L -1290 N F Rating -1 and 2 Hr (See Item 1) 3 T Rating - 0 Hr L Rating at Ambient - Less than 1 CFM /Sq Ft L Rating at 400° F - Less than 1 CFM /Sq Ft 1. Wall Assembly -- The 1 or 2 hr fire rated gypsum board /stud wall assembly shall be constructed of the materials and in the manner specified in the individual 0300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features. A Studs -- The 1 or 2 hr fire rated gypsum board /stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features. B. Gypsum Board * - -- Nom 5/8 in. thick, 4 ft wide with square or tapered edges. The gypsum board type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U300 or U400 Series Design in the Fire Resistance Directory. Max dam of opening is 5 in. The hourly F and T Ratings of the firestop system are equal to the hourly fire rating of the wall assembly in which it is installed. 2. Through Penetrant -- One metallic pipe, conduit or tubing installed concentrically or eccentrically within the firestop system. Pipe, conduit or tubing may be installed at an angle not greater than 45 degrees from perpendicular. Pipe, conduit or tube to be rigidly supported on both sides of wall assembly. The annular space between the pipe or tube and periphery of the opening shall be min 0 in (point contact) to max 1/2 in. The following types and sizes of metallic pipes, conduit or tube may be used: A Steel Pipe -- Nom 4 in. diam (or smaller) Schedule 40 (or heavier) steel pipe. B. Iron Pipe -- Nom 4 in. dam (or smaller) cast or ductile iron pipe. C. Conduit -- Nom 4 in. dam (or smaller) steel electrical metallic tubing (EMT) or steel conduit D. Copper Tube -- Nom 4 in. dam (or smaller) Type L (or heavier) copper tube. E. Copper Pipe -- Nom 4 in. dam (or smaller) Regular (or heavier) copper pipe. 3. Fill, Void or Cavity Material * - Sealant -- Min 5/8 in. thickness of fill material applied within the annulus, flush with both surfaces of wall. At the point contact location between pipe and wall, a min % in dam bead of fill material shall be applied at the pipe /wall interface. HILTI CONSTRUCTION CHEMCIALS, DIV OF HILTI INC -- CP606 Flexible Firestop Sealant *Bearing the UL Classification Mark Reproduced by HILTI, Inc. Courtesy of Ic,v l FVFp Unden!writers Laboratories, Inc. FIRESTOP SYSTEMS .tune 03, 2005 C US System No. C -AJ -2342 F Rating - 3 Hr 'a T Rating - 0 Hr W Rating - Class 1 (See Item 3B) Product Designation Pipe Size in. (mm) Max Opening Diam (in.) Annular Space Min in.(mm) Annular Space Max in. (mm) Number of Layers Nom Wrap Strip Width in. (mm) CP648 -E W2511' 11/2(38) 3(76) 3/16 (4.8) 15/16 (24) 1 1(25) CP648 -E W4511 -314" 11/2(38) 3 (76) 3/16(4.8) 1516 (24) 1 13/4 (45) CP648 -E W2511" 2 (51) 31/2(89) 3/16(4.8) 15116 (24) 1 1(25) CP648 -E W45/1 -314" 2 (51) 31/2(89) 3/16(4.8) 15116 (24) 1 1314 (45) CP648 -E W4511 -314' 3 (76) 4 (102) 3/16(4.8) 15116 (24) 1 1314 (45) CP648 -E W45/1 -314' 3 (76) 5 (127) 318 (10) 1 1/16(27) 2 1314 (45) CP648 -E W4511 -314' 4 (102) 6 (152) 318 (10) 11/8(29)1 77TF 1314 (45) Al. Fill, Void or Cavity Material' - Wrap Strip - (As an alternate to the wrap strip in Item 3A) - One layer of intumescent wrap strip is continuously wrapped around the pipe with ends butted and held in place with integrated tape. Wrap strip installed recessed max 1/4 in. (6 mm) from top surface of floor or from both surfaces of wall. Size of wrap strip for a given size penetrant are shown in the table below. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC - CP646- S-1.5" US, CP648 -S-2' US, CP648 -S-3" US or CP648 -SA" US Wrap Strip Product Designation Pipe Size Max Opening Annular Space Annular Space Nom Wrap Strip Nom Wrap Strip Thick in. Nom Wrap Strip Width in. in. mm ( ) Diam in. ( ) Min in. mm ( ) Max in. mm ( ) Len in. (mm) Length (mm) (mm) CP648- S-1.5° US 1 1/2 (38) 3 (76) 3/16(4.8) 15/16(24). 6.5(165) 0.18 (4.6) 1 (25) CP648 -S-2" US 2 (51) 3112 (89) 3116 (4.8) 15116 (24) 8 (203) 0.18 (4.6) 1 (25) CP648 -S-3" US 3(76) 4 (102) 3/16(4.8) 5/16 (8) 11.5 (292) 0.18 (4.6) 13/4(45) CP648 -S-4° US 4(102)- 6 (152} 318 (10) 11/8(29) 15.1 (384) 0.36(9) 1 3/4 (45) Al. Fill, Void or Cavity Material* - Wrap Strip - (As an alternate to the wrap strip in Item 3A) - One layer of intumescent wrap strip is continuously wrapped around the pipe with ends butted and held in place with integrated tape. Wrap strip installed recessed max 1/4 in. (6 mm) from top surface of floor or from both surfaces of wall. Size of wrap strip for a given size penetrant are shown in the table below. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC - CP648-S-1.5° US, CP648 -S -2' US, CP648 -S-3" US or CP648-SA" US Wrap Strip B. Fill, Void or Cavity Material" - Sealant - Min 1/4 in. (6 mm) thickness of fill material applied within the annulus, flush with top surface of floor of both surfaces of wall. W Rating applies only when CP 601S or CP 604 sealant is used. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC FS-ONE Sealant, CP 601S Sealant or CP 604 Sealant C. Packing Material (not shown) - Min 1/2 in. (13 mm) thickness of 4 pd (64 kg/m3) mineral wool batt insulation firmly packed into annular space and recessed from the top surface of floor to accommodate the required thickness of fill material. Required only when CP 604 Sealant is used. *Bearing the UL Classification Mark S►Fi Reproduced by HILTI, Inc. Courtesy of V Underwriters Laboratories, Inc. Systems August 2s,2oo7 Hilti Firestop Y m Page: 2 of 2 151 SEVILLA AVENUE, SUITE 200 CORAL GABLES, FL 33134 OFFICE: (305) 442 -1188 FAX: (305) 445 -1509 WWW. ADCINTERNATIONAL.NET STATE OF FLORIDA AR- 0010536 RAYMUNDO FEITO, R.A. AA- CO01315 Architect • Seal/Signature Construction Documents for: - SR PFW at: ONE 7000 PLACE SUITE: PHN 7th FLOOR 7000 SW 62nd AVENUE SOUTH MIAMI, FL 33143 9 Issue Date & Issue Description Drawn By Checked By 01 12/04/09 AC AR PERMIT ISSUE Z_ Z J CL W U CL i Z 0 N W IO n: O I-- Date & Delta Description Drawn By Checked By Z • t9 Z Z QZ IL • W H V W F- V Q Client Information HEALTHCARE REALTY 2601 SW 37th AVENUE SUITE 805 MIAMI, FL 33133 OFFICE: (305) 446 -3666 Project Number 09148 CAD File Name ONE 7000 PLACE - SUITE PHN DesPn , oNrG FIRE DETAILS Scale AS NOTED Consultant • Seal/Signature 1 1 �• I, I)