FIXTURE CONNECTION SCHEDULE
ITEM
WASTE &
SOIL
UNIT DESIGNATION
WATER
F.U.
COLD
HOT
WATER CLOSET
3"
4
1/2"
- -
LAVATORY
1-1/2-
1
1/2"
1/2
KITCHEN SINK
1 -1/2"
2
1/2"
1/2"
REFRIGERATOR
_ _
N/A
1/2"
- -
FLOOR DRAIN
3
2
TRAP SEAL
- -
w
0
w
z
w
cn
w
U
ry
w
Cn
0
cn
,z
w
V)
z 1%__
cn
¢
J
z
0
V)
cn
w
I
O
ry
z
CD
V)
w
0
w
M
xg
ti
I
I
I
Ica
0
I
cI.>
I
rs �.
�' 13+ f•�' ' ,>
I
0 -�
4-il III-100,
�c
af I ~ .4.
LIJ AFRO
•� I (S�GGf<)
�
z I WdA�R
C) I
� I c�
w aa S*
z yLAC>5�
0
z f cie
ME
U
° INSTANT WATER HEATER (ELECTRIC) \c,
CHRONOMITE MODEL SR -15L
4150 WATT
Z 277 VOLT
0
°
1
U
US REFER TO "GENERAL CONDITIONS FOR RENOVATION"
w (• #) FINAL LINE DIM. BASE ON WC SELECTION BY OWNER
ME
z
c>
0
°
ry
w
0
°
z
cn
w
0
z
°
z
a�
a
a
�J
w
L�
r�
� z
U
w
J V)
5
(r;
An
CHRONONTE
ELECT WATER
HTR'INSTANTANEOUS)
UNIT DESIGNATION
FIXTURE UNIT TABULATION
TANKLESS WATER HEATER
MODEL
HOT
SR -15L
DIMENSIONS
1/2"
6.25" x 9 -5/8" x 2 -3/4"
WEIGHT
5 POUNDS
PIPE FITTING
1/4" NPT STANDARD PIPE THREAD
PRESSURE REQUIREMENTS
25 PSI MIN /150 PSI MAX
VOLTAGE
277 V
KW RATING
4,150 W
MAXIMUM OPERATING TEMPERATURE 140 F
FLOW SWITCH ACTIVATION
0.4 GPM
FLOW SWITCH DE— ACTIVATION
0.35 GPM
* GENERAL CONDITIONS FOR RENOVATIONS
1 -THE PLUMBING CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO BID AND
VERIFY ALL CONDITIONS, LOCATION, DIMENSIONS, MATERIALS, ELEVATIONS AND
COUNTS AS SHOWN AND /OR NOTED ON THE DRAWINGS AND INCLUDE IN THE BID
ANY AND ALL FABRICATION REQUIRED PRIOR TO INSTALLATION.THE CONTRACTOR
SHALL VERIFY SIZE, ELEVATION AND PRESENT STATE OF ALL EXISTING UTILITIES,
AND SHALL NOTIFY ENGINEER IF PIPE SIZE CHANGES ARE REQUIRED BECAUSE OF
EXISTING CONDITIONS.
2 -THE PLUMBING CONTRACTOR SHALL DETERMINE THE EXTENT TO WHICH
EXISTING PIPING WILL HAVE TO BE REROUTED, RELOCATED, OR RECONNECTED,
AND THE AMOUNT OF ADDITIONAL WORK WHICH MAY BE REQUIRED DUE TO THE
PHYSICAL CONDITIONS OF THE PIPING SHALL BE PERFORMED UNDER THIS
CONTRACT WITHOUT ADDITIONAL CHARGES TO THE OWNER.
3 -THE CONTRACTOR SHALL COORDINATE HIS WORK WITH THE ACTUAL
DIMENSIONS AND ROUGH -IN LOCATIONS FOR THE EQUIPMENT BEING REUSED.
4- PLUMBING EQUIPMENT THAT IS TO REMAIN IN AREAS WHERE THE INSTALLATION
WILL INTERFERE WITH THE INSTALLATION OF NEW EQUIPMENT OR NEW
ARCHITECTURAL CHANGES , SHALL BE REMOVED, RELOCATED, OR RE- ROUTED TO
PERMIT COMPLETION OF SUCH WORK.
5— SALVAGED MATERIALS, EQUIPMENT, AND PLUMBIN FIXTURES SHALL BE DELIVERED
TO THE OWNER AT HIS PROPERTY AND STOREDNITHIN THE BUILDING WHERE
DIRECTED. ANY REMOVED MATERIALS OR EQUIPMENTVHICH THE OWNER DOES NOT
WISH TO KEEP SHALL BE DISPOSED OF BY THE CONTACTOR, WITHOUT ADDITIONAL
COST TO THE OWNER.
6 —ALL PRESENT PIPING IN EXISTING AREAS TO BE AIERED, WHICH WILL HAVE NO
USE UPON COMPLETION OF THE ALTERATIONS SHALL E REMOVED. PIPING WHICH IS
OR WILL BECOME EXPOSED TO VIEW, OR WILL INTERFEE WITH THE INSTALLATION
AND COMPLETION OF THE WORK REQUIRED, SHALL BRELOCATED. PIPING SHALL
NOT BE RUN EXPOSED THROUGH EXISTING OR NEW FIISH SPACE UNLESS WRITTEN
PERMISSION IS GRANTED BY THE OWNER.
7- INTERRUPTION OF EXISTING FACULTIES OR SERVICS SHALL BE KEPT TO A
MINIMUM AND THE CONTRACTOR SHALL FURNISH AL MATERIALS AND LABOR
REQUIRED WHENEVER TEMPORARY CONDITIONS ARE NECESSARY TO MAINTAIN
CONTINUITY OF SERVICE . INTERRUPTION OF SERVICS , THE INSTALLATION OF
TEMPORARY FACILITIES, AND THE WORK OF MAKING 4NAL CONNECTIONS TO NEW
WORK SHALL BE DONE ONLY AT SUCH TIMES AS PERAITTED AND SCHEDULED BY
THE OWNER WITHOUT ADDITIONAL COST. THE PLUMBING CONTRACTOR SHALL BE
RESPONSIBLE TO COORDINATE THE SERVICE INTERRUPTIONS WITH THE OWNER AND
GENERAL CONTRACTOR.
�• PLUMBING NOTES AND DETAILS
Scale: NTS
.. i i i i i i
PROJECT NOTES
-ALL DISCONNECTED PLUMBING LINES FOR EXISTING FIXTURES SHALL BE CAPPED.NO LINES SHALL REMAIN
OPEN TO THE ATMOSPHERE
- INSTALL A WATER HAMMER ARRESTER FOR EACH PLUMBING FIXTURE SUPPLY BRANCH USING TABLE (2/12-2)
- INSTALL A SHUTOFF VALVE ON THE FIXTURE SUPPLY TO EACH PLUMBING FIXTURE.
-THE INSTALLATION OF ANY PART OF PLUMBING SYSTEM SHALL BE ACCORDING TO FBC -P SECTION 307
-ANY PLUMBING LINES WHICH REQUIRE REMOVAL AND /OR ALTERATION, G.C. SHALL CAP AND FILL SLAB
WITH SAME FIRE RATED INTEGRITY.
- PROVIDE METAL SLEEVE AT ALL WALL AND SLAB PENETRATIONS.
-ALL HORIZONTAL DRAIN PIPE 2 "N OR SMALLER SHALL BE SLOPED AT 1 /4 " /FT
-ALL HORIZONTAL DRAIN PIPE FROM 3" TO 6" SHALL BE SLOPED AT 1 /8 " /FT MIN.
-ALL HORIZONTAL DRAIN PIPE 8" OR LARGER SHALL BE SLOPED AT 1/16 " /FT MIN
- PROVIDE AUTOMATIC TRAP RESEAL FOR ALL FLOOR DRAINS
$CONNECT NEW LINES TO EXISTING, VERIFY EXACT LOCATION,SIZE & CAPACITY IN FIELD PRIOR TO BID THE
PROJECT. NOTIFY ARCHITECT & ENGINEER OF ANY DISCREPANCIES.
CONTRACTOR IS STRONGLY ENCOURAGE TO PERFORM A VISIT TO VERIFY ALL CONDITIONS THAT MAY AFFECT THE
SCOPE OF WORK.CONTRACTOR NOT PERFORMING A SITE VISIT ARE ACKNOWLEDGING AND ACCEPTING ALL SITE
CONDITIONS AS THEY EXIST. VERIFY: POINTS OF CONNECTIONS; EXISTING LINES ( SIZE, CAPACITY,MATERIALS, ....)
-ALL PLUMBING WORK PERFORMED UNDER THIS CONTRACT SHALL COMPLY WITH LOCAL CODES AND ORDINANCES
AND ALL STANDARDS OF CONSTRUCTION ESTABLISHED BY THE LANDLORD.
SUBMIT SHOP DRAWINGS FOR ACCEPTANCE BY THE ARCHITECT AND /OR ENGINEER BEFORE PROCEEDING WITH
THE PURCHASE OR INSTALLATION OF THE EQUIPMENT AND MATERIALS. NO FACSIMILES OR FACSIMILE COPIES
SHALL BE ACCEPTED.
-IF ANY CONFLICT IS ENCOUNTERED WITHIN THE DESIGN DOCUMENTS, REGARDLESS OF TRADE OR RESPONSIBILITY,
THE GREATER SCOPE OF WORK SHALL PREVAIL.
THESE PLANS ARE FOR BUILDING DEPARTMENT REVIEW ONLY. THEY ARE NOT TO CONSTRUED AS
CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENT APPROVALS ARE OBTAINED.
- CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS BEFORE PROCEEDING WITH WORK.IF ANY
DISCREPANCIES,ERRORS OR OMISSIONS ARE ENCOUNTERED ON PLANS, CONTRACTOR SHALL NOTIFY ARCHITECT /'!
ENGINEER BEFORE ANY PART OF THE WORK IS STARTED SO THAT PROPER CORRECTIONS BE MADE. IF
ARCHITECTS /ENGINEER IS NOT NOTIFIED PRIOR TO COMMENCING OF THE WORK, THE CONTRACTOR SHALL!
BEAR FULL RESPONSIBILITY FOR ANY DISCREPANCIES , ERROR OR OMISSIONS.
INSTALL PER PDI STANDARDS AND
MANUFACTURER'S INSTRUCTIONS.
PROVIDE A WHA AT ALL QUICK
CLOSING VALVES.
SINGLE/DOUBLE FIXTURE
HOT OR COLD WATER SUPPLY
IF HORIZONTAL BRANCH IS LESS THAN 20' LONG,
PROVIDE ONE WHA AT THE END OF LINE
IF BRANCH IS GREATER THAN 20' LONG, PROVIDE
ANOTHER WHA IN MIDDLE, EACH SIZED FOR HALF THE
FIXTURE UNITS.
I I b b I b b b b b
MULTIPLE FIXTURE
HIDROTROL
PDI
SIZE
PIPE
SIZE
FIXTURE
UNIT LOAD
FIXTURE UNIT TABULATION
FIXTURE
COLD
HOT
5005
A
1/2"
1 -11
VALVE WATER CLOSET
10
-
5010
B
3/4"
12 -32
TANK WATER CLOSET
5
-
5020
C
in
33-60
URINAL
5
-
5030
D
1-1/4"
61 -113
LAVATORY /SINK
1.5
1.5
5040
E
1 -1/2'
114 -154
JANITOR'S SINK
3
3
5050
F
1 2"
155 -330
SHOWER/BATHTUB
2
2
FOR BATTERIES OF FIXTURES , PROVIDE WATER HAMMER ARRESTERS BY SIOUX CHIEF, PRECISION PLUMBING
PRODUCTS, WATTS OR APPROVED EQUIVALENT WITH PISTON AND O-RING CONSTRUCTION , HAVING PDI # WH -2001,
ASSE # 1010 AND ANSI # A112.26.1M CERTIFICATION , INSTALL IN HORIZONTAL OR VERTICAL POSITION , BUT
NEVER UPSIDE DOWN. THE DRAWING AND /OR PER THE TABLES SHOVE ABOVE. PROVIDE ACCESSIBILITY TO "WHA"
WHERE REQUIRED BY LOCAL CODE
WATER HAMMER ARRESTERS
N.T.S.
1/2-
5'
INSTALL REINFORCING WIRE TO INSERT IN
3/4"
5'
NEW CONCRETE CONSTRUCTION.
HANG PIPE LARGER THAN 4" FROM TOP
STEEL DECK
CONCRETE SLAB
OF JOISTS ONLY AT PANEL POINT
7' 1
8'
1 -1/2"
SERVED BY ONE TRAP PRIMER
NOT DOWNSTREAM.
2"
VALVE.
LOCATE TRAP PRIMER WHERE AN
; '� DRILLED —IN THREADED INSERT FOR EXISTING
10'
if
C— CLAMP, CONNECT TO TOP
11'
ALL— THREAD
ROD
12'
.:
CONCRETE SLAB OR CAST IN PLACE FOR NEW
OF BEAM OR STEEL BAR JOIST
TYPE "K" SOFT COPPER TUBING.
LOCATION. INSTALL PRIMER
;. w CONCRETE CONSTRUCTION. DO NOT USE SHOT -IN
MINIMUM 6" ABOVE FLOOD RIM OF
SLOPE CONTINUOUSLY TOWARDS
FIXTURE BEING SERVED.
;. INSERTS.
ADJUSTABLE BAND HANGER FOR PIPE 3 -1/2"
PROVIDE FLOOR DRAIN BODY OR
PROVIDE COPPER
CONCRETE FLOOR
,
AND SMALLER AND CAST IRON PIPE 2" AND
COATED HANGERS
IF PIPE IS BELOW FLOOR SLAB
FITTINGS AND ADAPTERS AS ° '
SMALLER
REQUIRED TO MAKE WATER -TIGHT
WHERE HANGERS
CONNECTION TO DRAIN.
CLEVIS HANGER FOR PIPE 4" AND LARGER
FLOOR SLAB.
CONTACT BARE
LOCAL AUTHORITIES. PIPING ARRANGEMENT SHOWN IS
AND CAST IRON PIPE 3" AND LARGER
z z
COPPER PIPE
Q
a� �
w a
(n W W J w
w o a w a PROVIDE GALVANIZED STEEL SHEILD FOR ALL INSULATED PIPE VERIFY
a V= m= INSULATION THICKNESS WHEN SIZING HANGERS AND SHIELDS.
1/2-
5'
7'
3/4"
5'
7'
in
6'
7'
1 -1/4"
7' 1
8'
1 -1/2"
SERVED BY ONE TRAP PRIMER
NOT DOWNSTREAM.
2"
VALVE.
LOCATE TRAP PRIMER WHERE AN
2-1/2-1
10'
if
3"
11'
12'
4"
12'
14'
PROVIDE UPPER ATTACHMENT AS REQUIRED FOR CASES NOT SHOWN
HERE DO NOT INSTALL HANGER INSIDE INSULATION OR OTHERWISE
PENETRATE VAPOR BARRIER. DO NOT HANG ONE PIPE FROM ANOTHER
EXCEPT IN CHASES. SLOPEALL WATER PIPING SLIGHTLY TOWARD
DRAINABLE LOCATIONS. HANGER SPACING FOR PIPE SIZE: AS
INDICATED ON TABLE. CAST IRON: 10' AND WITHIN 1' -0" OF ALL JOINTS.
ROD SIZES FOR PIPE SIZE: 2" AND SMALLER =3/8 ", 2 1/2" TO 3 " =1/2 ",
4 " =5f 8 ", 6 " =3/4 ", 8" AND LARGER =7/8 ". LOCATE HANGERS WITHIN
1' -0 OF VALVES AND FITTINGS. PROVIDE SUPPLEMENTARY STEEL
STRUTS BETWEEN JOISTS IF REQUIRED. LOCATE HANGERS WITHIN 1' -0"
OF EQUIPMENT CONNECTIONS. ANCHOR WATER PIPE AGAINST SWAYING
DUE TO CHANGES IN WATER VELOCITY. CHAINS AND PERFORATED STRAP
IRON AND STEEL ARE NOT ACCEPTABLE. DO NOT SUSPEND PIPE FROM
JOIST BRACING MEMBERS. REFER TO CODES AND SPECS FOR FURTHER
INFORMATION. PROVIDE SEISMIC BRACING IF /AS REQUIRED BY LOCAL
AUTHORITIES. TRAPEZE HANGERS MAY BE USED FOR MULTIPLE PARRALLEL
PIPES, SEE "TRAPEZE PIPE HANGER DETAIL"
3 PIPE HANGERS
N.T.S.
FAUCET FLOW CONTROL
I HOT WATER OUTLET
HOT WATER
HEATER
ELECTRICAL
SUPPLY
"HOT" VALVE
.-- "COLD" VALVE
COPPER
TUBING
SINK
MAIN PIPE
COLD WATER INLET
- SOV
LAVATORY WATER AND ALL DRAINING PIPING
SHALL BE INSULATED OR PROTECTED FROM
CONTACT. THE INSTANT HOT WATER HEATER
SHALL NOT HAVE ANY SHARP EDGE OR
ABRASIVE SURFACES , HOT WATER HEATER
SHALL BE PROTECTED FROM CONTACT.
O INSTANT ELECT WATER HTR.
N.T.S
�r-`1-' 1
FLOOR CLEANOUT (F.C.O.)
C.O. NOT TO BE LOCATED IN
CARPETED AREA
Q MAY EXTEND AS A WASTE
OR VENT. REFER TO PLANS.
2O CHROME WALLCOVER & SCREW.
WALL
4O PLUGGED TEE W /CLEANOUT.
O FLOOR LINE
6O 1/8" C.I. BEND
BALANCE OF PIPING SAME AS CLEANOUT TO GRADE.
O CLEANOUT & ACCESS COVER TO BE
FLUSH W/TOP OF FLOOR.
9� BALANCE OF PIPING SAME AS CLEANOUT TO GRADE.
10 BRASS CLEANOUT PLUG W /COUNTER SUNK HEAD.
11 FINISH GRADE
12 16" SQUARE CONC. PAD TROWEL. SMOOTH AND EDGE
13 C.I. WASTE LINE LENGTH TO SUITE.
14 WASTE UNE
15 1/8 BEND IF CLEANOUT OCCURS AT END OF LINE
�} CLEANOUT DETAILS
N.T.S.
MAKE 1/2" BRANCH TO TRAP
AUTOMATIC TRAP PRIMER VALVE
PRIMER OFF TOP OF DOMESTIC
WITH INTEGRAL AIR GAP.
COLD WATER BRANCH PIPE TO
PROVIDE DISTRIBUTION UNIT(S)
FIXTURE(S). INSULATE PIPE
r1h
WHERE MORE THAN ONE TRAP IS
UPSTREAM OF TRAP PRIMER, BUT
SERVED BY ONE TRAP PRIMER
NOT DOWNSTREAM.
VALVE.
LOCATE TRAP PRIMER WHERE AN
INSTALL TRAP PRIMER UNES
ACCESS DOOR (REFER TO
DOWNSTREAM OF TRAP PRIMER
SPECIFICATIONS) CAN BE PLACED
OR DISTRIBUTION UNIT USING 1/2"
IN FRONT OF IT IN AN ACCESSIBLE
TYPE "K" SOFT COPPER TUBING.
LOCATION. INSTALL PRIMER
INSTALL WITHOUT KINKS, AND
MINIMUM 6" ABOVE FLOOD RIM OF
SLOPE CONTINUOUSLY TOWARDS
FIXTURE BEING SERVED.
FLOOR DRAIN.
PROVIDE FLOOR DRAIN BODY OR
CONCRETE FLOOR
P -TRAP WITH THREADED TRAP
PRIMER CONNECTION. PROVIDE , 4:
IF PIPE IS BELOW FLOOR SLAB
FITTINGS AND ADAPTERS AS ° '
ON GRADE, PROVIDE 1/2"
REQUIRED TO MAKE WATER -TIGHT
ELASTOMERIC INSULATION FROM
CONNECTION TO DRAIN.
PRIMER CONNECTION TO 1" ABOVE
FLOOR SLAB.
PROVIDE TRAP PRIMERS WHERE SHOWN ON FLOOR PLANS, AND WHERE REQUIRED BY
LOCAL AUTHORITIES. PIPING ARRANGEMENT SHOWN IS
SCHEMATIC: ADJUST TO SUITE
AUTHORITIES AND FIELD CONDITIONS.
TRAP PRIMER IN WET WALL
N.T.S.
wa
/i Atoll,
�/�
'AiTELTU DESIGN (s�,`
151 Si�VlL.A AVENUc SIiITc 200
CORAL GABLES, FL 33134
OFFICE: (305) 442 -1188
FAX: (305) 445 -1509
VVWW. ADCINTERNATIONAL.NET
STATE OF FLORIDA AR- 0010536
RAYMUNDO FEITO, R.A. AA- CO01315
Architect • Sea[/Signature
Construction Documents for:
SUM PHN
at:
ONE 7000 PLACE
SUITE: PHN
7th FLOOR
7000 SW 62nd AVENUE
SOUTH MIAMI, FL 33143
Issue Date & Issue Description Drawn By Checked By
01 12, 0 4 09 AC AR
PERMIT ISSUE
02 01 X13/10 AC AR
PRICING SUBMITTAL
Z_
Z
a
W
a
0
W
0
O
R
W
F-
Date & Delta Description Drawn By Checked By
f
Z
Qz
a
0
UJ
v
W
H
Q
Client Information
HEALTHCARE REALTY
2601 SW 37th AVENUE
SUITE 805
MIAMI, FL 33133
OFFICE: (305) 446 -3666
Project Number
09148
CAD File Name
ONE 7000 PLACE - SUITE PHN
DescnMPIN NOTES AND DETAILS on
Scale
AS NOTED
Consultant • Seal/Signature
ENG EERTNG
DA�,Ti Z «' 0 RP.
.,
21 SW 102G:M'i 1
0 0ffice:, ).8 92a �Q
z Fax: (305) 22 -5196
co pgengineerdesignftellsouth.net
2
Z) P=2o
,J STATE OF FLORIDA M
ERGUIN CAPOTE P.E. No. 62487
LUIS O. PEREZ, PE P.E. No. 62586
i