10-323-018J z 0 V) w w 0 a z c� V) w w 0 IM FIXTURE CONNECTION SCHEDULE ITEM WASTE & SOIL UNIT DESIGNATION WATER F.U. COLD HOT WATER CLOSET 3" 4 1/2" - - LAVATORY 1-1/2- 1 1/2" 1/2 KITCHEN SINK 1 -1/2" 2 1/2" 1/2" REFRIGERATOR _ _ N/A 1/2" - - FLOOR DRAIN 3 2 TRAP SEAL - - w 0 w z w cn w U ry w Cn 0 cn ,z w V) z 1%__ cn ¢ J z 0 V) cn w I O ry z CD V) w 0 w M xg ti I I I Ica 0 I cI.> I rs �. �' 13+ f•�' ' ,> I 0 -� 4-il III-100, �c af I ~ .4. LIJ AFRO •� I (S�GGf<) � z I WdA�R C) I � I c� w aa S* z yLAC>5� 0 z f cie ME U ° INSTANT WATER HEATER (ELECTRIC) \c, CHRONOMITE MODEL SR -15L 4150 WATT Z 277 VOLT 0 ° 1 U US REFER TO "GENERAL CONDITIONS FOR RENOVATION" w (• #) FINAL LINE DIM. BASE ON WC SELECTION BY OWNER ME z c> 0 ° ry w 0 ° z cn w 0 z ° z a� a a �J w L� r� � z U w J V) 5 (r; An CHRONONTE ELECT WATER HTR'INSTANTANEOUS) UNIT DESIGNATION FIXTURE UNIT TABULATION TANKLESS WATER HEATER MODEL HOT SR -15L DIMENSIONS 1/2" 6.25" x 9 -5/8" x 2 -3/4" WEIGHT 5 POUNDS PIPE FITTING 1/4" NPT STANDARD PIPE THREAD PRESSURE REQUIREMENTS 25 PSI MIN /150 PSI MAX VOLTAGE 277 V KW RATING 4,150 W MAXIMUM OPERATING TEMPERATURE 140 F FLOW SWITCH ACTIVATION 0.4 GPM FLOW SWITCH DE— ACTIVATION 0.35 GPM * GENERAL CONDITIONS FOR RENOVATIONS 1 -THE PLUMBING CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO BID AND VERIFY ALL CONDITIONS, LOCATION, DIMENSIONS, MATERIALS, ELEVATIONS AND COUNTS AS SHOWN AND /OR NOTED ON THE DRAWINGS AND INCLUDE IN THE BID ANY AND ALL FABRICATION REQUIRED PRIOR TO INSTALLATION.THE CONTRACTOR SHALL VERIFY SIZE, ELEVATION AND PRESENT STATE OF ALL EXISTING UTILITIES, AND SHALL NOTIFY ENGINEER IF PIPE SIZE CHANGES ARE REQUIRED BECAUSE OF EXISTING CONDITIONS. 2 -THE PLUMBING CONTRACTOR SHALL DETERMINE THE EXTENT TO WHICH EXISTING PIPING WILL HAVE TO BE REROUTED, RELOCATED, OR RECONNECTED, AND THE AMOUNT OF ADDITIONAL WORK WHICH MAY BE REQUIRED DUE TO THE PHYSICAL CONDITIONS OF THE PIPING SHALL BE PERFORMED UNDER THIS CONTRACT WITHOUT ADDITIONAL CHARGES TO THE OWNER. 3 -THE CONTRACTOR SHALL COORDINATE HIS WORK WITH THE ACTUAL DIMENSIONS AND ROUGH -IN LOCATIONS FOR THE EQUIPMENT BEING REUSED. 4- PLUMBING EQUIPMENT THAT IS TO REMAIN IN AREAS WHERE THE INSTALLATION WILL INTERFERE WITH THE INSTALLATION OF NEW EQUIPMENT OR NEW ARCHITECTURAL CHANGES , SHALL BE REMOVED, RELOCATED, OR RE- ROUTED TO PERMIT COMPLETION OF SUCH WORK. 5— SALVAGED MATERIALS, EQUIPMENT, AND PLUMBIN FIXTURES SHALL BE DELIVERED TO THE OWNER AT HIS PROPERTY AND STOREDNITHIN THE BUILDING WHERE DIRECTED. ANY REMOVED MATERIALS OR EQUIPMENTVHICH THE OWNER DOES NOT WISH TO KEEP SHALL BE DISPOSED OF BY THE CONTACTOR, WITHOUT ADDITIONAL COST TO THE OWNER. 6 —ALL PRESENT PIPING IN EXISTING AREAS TO BE AIERED, WHICH WILL HAVE NO USE UPON COMPLETION OF THE ALTERATIONS SHALL E REMOVED. PIPING WHICH IS OR WILL BECOME EXPOSED TO VIEW, OR WILL INTERFEE WITH THE INSTALLATION AND COMPLETION OF THE WORK REQUIRED, SHALL BRELOCATED. PIPING SHALL NOT BE RUN EXPOSED THROUGH EXISTING OR NEW FIISH SPACE UNLESS WRITTEN PERMISSION IS GRANTED BY THE OWNER. 7- INTERRUPTION OF EXISTING FACULTIES OR SERVICS SHALL BE KEPT TO A MINIMUM AND THE CONTRACTOR SHALL FURNISH AL MATERIALS AND LABOR REQUIRED WHENEVER TEMPORARY CONDITIONS ARE NECESSARY TO MAINTAIN CONTINUITY OF SERVICE . INTERRUPTION OF SERVICS , THE INSTALLATION OF TEMPORARY FACILITIES, AND THE WORK OF MAKING 4NAL CONNECTIONS TO NEW WORK SHALL BE DONE ONLY AT SUCH TIMES AS PERAITTED AND SCHEDULED BY THE OWNER WITHOUT ADDITIONAL COST. THE PLUMBING CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE THE SERVICE INTERRUPTIONS WITH THE OWNER AND GENERAL CONTRACTOR. �• PLUMBING NOTES AND DETAILS Scale: NTS .. i i i i i i PROJECT NOTES -ALL DISCONNECTED PLUMBING LINES FOR EXISTING FIXTURES SHALL BE CAPPED.NO LINES SHALL REMAIN OPEN TO THE ATMOSPHERE - INSTALL A WATER HAMMER ARRESTER FOR EACH PLUMBING FIXTURE SUPPLY BRANCH USING TABLE (2/12-2) - INSTALL A SHUTOFF VALVE ON THE FIXTURE SUPPLY TO EACH PLUMBING FIXTURE. -THE INSTALLATION OF ANY PART OF PLUMBING SYSTEM SHALL BE ACCORDING TO FBC -P SECTION 307 -ANY PLUMBING LINES WHICH REQUIRE REMOVAL AND /OR ALTERATION, G.C. SHALL CAP AND FILL SLAB WITH SAME FIRE RATED INTEGRITY. - PROVIDE METAL SLEEVE AT ALL WALL AND SLAB PENETRATIONS. -ALL HORIZONTAL DRAIN PIPE 2 "N OR SMALLER SHALL BE SLOPED AT 1 /4 " /FT -ALL HORIZONTAL DRAIN PIPE FROM 3" TO 6" SHALL BE SLOPED AT 1 /8 " /FT MIN. -ALL HORIZONTAL DRAIN PIPE 8" OR LARGER SHALL BE SLOPED AT 1/16 " /FT MIN - PROVIDE AUTOMATIC TRAP RESEAL FOR ALL FLOOR DRAINS $CONNECT NEW LINES TO EXISTING, VERIFY EXACT LOCATION,SIZE & CAPACITY IN FIELD PRIOR TO BID THE PROJECT. NOTIFY ARCHITECT & ENGINEER OF ANY DISCREPANCIES. CONTRACTOR IS STRONGLY ENCOURAGE TO PERFORM A VISIT TO VERIFY ALL CONDITIONS THAT MAY AFFECT THE SCOPE OF WORK.CONTRACTOR NOT PERFORMING A SITE VISIT ARE ACKNOWLEDGING AND ACCEPTING ALL SITE CONDITIONS AS THEY EXIST. VERIFY: POINTS OF CONNECTIONS; EXISTING LINES ( SIZE, CAPACITY,MATERIALS, ....) -ALL PLUMBING WORK PERFORMED UNDER THIS CONTRACT SHALL COMPLY WITH LOCAL CODES AND ORDINANCES AND ALL STANDARDS OF CONSTRUCTION ESTABLISHED BY THE LANDLORD. SUBMIT SHOP DRAWINGS FOR ACCEPTANCE BY THE ARCHITECT AND /OR ENGINEER BEFORE PROCEEDING WITH THE PURCHASE OR INSTALLATION OF THE EQUIPMENT AND MATERIALS. NO FACSIMILES OR FACSIMILE COPIES SHALL BE ACCEPTED. -IF ANY CONFLICT IS ENCOUNTERED WITHIN THE DESIGN DOCUMENTS, REGARDLESS OF TRADE OR RESPONSIBILITY, THE GREATER SCOPE OF WORK SHALL PREVAIL. THESE PLANS ARE FOR BUILDING DEPARTMENT REVIEW ONLY. THEY ARE NOT TO CONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENT APPROVALS ARE OBTAINED. - CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS BEFORE PROCEEDING WITH WORK.IF ANY DISCREPANCIES,ERRORS OR OMISSIONS ARE ENCOUNTERED ON PLANS, CONTRACTOR SHALL NOTIFY ARCHITECT /'! ENGINEER BEFORE ANY PART OF THE WORK IS STARTED SO THAT PROPER CORRECTIONS BE MADE. IF ARCHITECTS /ENGINEER IS NOT NOTIFIED PRIOR TO COMMENCING OF THE WORK, THE CONTRACTOR SHALL! BEAR FULL RESPONSIBILITY FOR ANY DISCREPANCIES , ERROR OR OMISSIONS. INSTALL PER PDI STANDARDS AND MANUFACTURER'S INSTRUCTIONS. PROVIDE A WHA AT ALL QUICK CLOSING VALVES. SINGLE/DOUBLE FIXTURE HOT OR COLD WATER SUPPLY IF HORIZONTAL BRANCH IS LESS THAN 20' LONG, PROVIDE ONE WHA AT THE END OF LINE IF BRANCH IS GREATER THAN 20' LONG, PROVIDE ANOTHER WHA IN MIDDLE, EACH SIZED FOR HALF THE FIXTURE UNITS. I I b b I b b b b b MULTIPLE FIXTURE HIDROTROL PDI SIZE PIPE SIZE FIXTURE UNIT LOAD FIXTURE UNIT TABULATION FIXTURE COLD HOT 5005 A 1/2" 1 -11 VALVE WATER CLOSET 10 - 5010 B 3/4" 12 -32 TANK WATER CLOSET 5 - 5020 C in 33-60 URINAL 5 - 5030 D 1-1/4" 61 -113 LAVATORY /SINK 1.5 1.5 5040 E 1 -1/2' 114 -154 JANITOR'S SINK 3 3 5050 F 1 2" 155 -330 SHOWER/BATHTUB 2 2 FOR BATTERIES OF FIXTURES , PROVIDE WATER HAMMER ARRESTERS BY SIOUX CHIEF, PRECISION PLUMBING PRODUCTS, WATTS OR APPROVED EQUIVALENT WITH PISTON AND O-RING CONSTRUCTION , HAVING PDI # WH -2001, ASSE # 1010 AND ANSI # A112.26.1M CERTIFICATION , INSTALL IN HORIZONTAL OR VERTICAL POSITION , BUT NEVER UPSIDE DOWN. THE DRAWING AND /OR PER THE TABLES SHOVE ABOVE. PROVIDE ACCESSIBILITY TO "WHA" WHERE REQUIRED BY LOCAL CODE WATER HAMMER ARRESTERS N.T.S. 1/2- 5' INSTALL REINFORCING WIRE TO INSERT IN 3/4" 5' NEW CONCRETE CONSTRUCTION. HANG PIPE LARGER THAN 4" FROM TOP STEEL DECK CONCRETE SLAB OF JOISTS ONLY AT PANEL POINT 7' 1 8' 1 -1/2" SERVED BY ONE TRAP PRIMER NOT DOWNSTREAM. 2" VALVE. LOCATE TRAP PRIMER WHERE AN ; '� DRILLED —IN THREADED INSERT FOR EXISTING 10' if C— CLAMP, CONNECT TO TOP 11' ALL— THREAD ROD 12' .: CONCRETE SLAB OR CAST IN PLACE FOR NEW OF BEAM OR STEEL BAR JOIST TYPE "K" SOFT COPPER TUBING. LOCATION. INSTALL PRIMER ;. w CONCRETE CONSTRUCTION. DO NOT USE SHOT -IN MINIMUM 6" ABOVE FLOOD RIM OF SLOPE CONTINUOUSLY TOWARDS FIXTURE BEING SERVED. ;. INSERTS. ADJUSTABLE BAND HANGER FOR PIPE 3 -1/2" PROVIDE FLOOR DRAIN BODY OR PROVIDE COPPER CONCRETE FLOOR , AND SMALLER AND CAST IRON PIPE 2" AND COATED HANGERS IF PIPE IS BELOW FLOOR SLAB FITTINGS AND ADAPTERS AS ° ' SMALLER REQUIRED TO MAKE WATER -TIGHT WHERE HANGERS CONNECTION TO DRAIN. CLEVIS HANGER FOR PIPE 4" AND LARGER FLOOR SLAB. CONTACT BARE LOCAL AUTHORITIES. PIPING ARRANGEMENT SHOWN IS AND CAST IRON PIPE 3" AND LARGER z z COPPER PIPE Q a� � w a (n W W J w w o a w a PROVIDE GALVANIZED STEEL SHEILD FOR ALL INSULATED PIPE VERIFY a V= m= INSULATION THICKNESS WHEN SIZING HANGERS AND SHIELDS. 1/2- 5' 7' 3/4" 5' 7' in 6' 7' 1 -1/4" 7' 1 8' 1 -1/2" SERVED BY ONE TRAP PRIMER NOT DOWNSTREAM. 2" VALVE. LOCATE TRAP PRIMER WHERE AN 2-1/2-1 10' if 3" 11' 12' 4" 12' 14' PROVIDE UPPER ATTACHMENT AS REQUIRED FOR CASES NOT SHOWN HERE DO NOT INSTALL HANGER INSIDE INSULATION OR OTHERWISE PENETRATE VAPOR BARRIER. DO NOT HANG ONE PIPE FROM ANOTHER EXCEPT IN CHASES. SLOPEALL WATER PIPING SLIGHTLY TOWARD DRAINABLE LOCATIONS. HANGER SPACING FOR PIPE SIZE: AS INDICATED ON TABLE. CAST IRON: 10' AND WITHIN 1' -0" OF ALL JOINTS. ROD SIZES FOR PIPE SIZE: 2" AND SMALLER =3/8 ", 2 1/2" TO 3 " =1/2 ", 4 " =5f 8 ", 6 " =3/4 ", 8" AND LARGER =7/8 ". LOCATE HANGERS WITHIN 1' -0 OF VALVES AND FITTINGS. PROVIDE SUPPLEMENTARY STEEL STRUTS BETWEEN JOISTS IF REQUIRED. LOCATE HANGERS WITHIN 1' -0" OF EQUIPMENT CONNECTIONS. ANCHOR WATER PIPE AGAINST SWAYING DUE TO CHANGES IN WATER VELOCITY. CHAINS AND PERFORATED STRAP IRON AND STEEL ARE NOT ACCEPTABLE. DO NOT SUSPEND PIPE FROM JOIST BRACING MEMBERS. REFER TO CODES AND SPECS FOR FURTHER INFORMATION. PROVIDE SEISMIC BRACING IF /AS REQUIRED BY LOCAL AUTHORITIES. TRAPEZE HANGERS MAY BE USED FOR MULTIPLE PARRALLEL PIPES, SEE "TRAPEZE PIPE HANGER DETAIL" 3 PIPE HANGERS N.T.S. FAUCET FLOW CONTROL I HOT WATER OUTLET HOT WATER HEATER ELECTRICAL SUPPLY "HOT" VALVE .-- "COLD" VALVE COPPER TUBING SINK MAIN PIPE COLD WATER INLET - SOV LAVATORY WATER AND ALL DRAINING PIPING SHALL BE INSULATED OR PROTECTED FROM CONTACT. THE INSTANT HOT WATER HEATER SHALL NOT HAVE ANY SHARP EDGE OR ABRASIVE SURFACES , HOT WATER HEATER SHALL BE PROTECTED FROM CONTACT. O INSTANT ELECT WATER HTR. N.T.S �r-`1-' 1 FLOOR CLEANOUT (F.C.O.) C.O. NOT TO BE LOCATED IN CARPETED AREA Q MAY EXTEND AS A WASTE OR VENT. REFER TO PLANS. 2O CHROME WALLCOVER & SCREW. WALL 4O PLUGGED TEE W /CLEANOUT. O FLOOR LINE 6O 1/8" C.I. BEND BALANCE OF PIPING SAME AS CLEANOUT TO GRADE. O CLEANOUT & ACCESS COVER TO BE FLUSH W/TOP OF FLOOR. 9� BALANCE OF PIPING SAME AS CLEANOUT TO GRADE. 10 BRASS CLEANOUT PLUG W /COUNTER SUNK HEAD. 11 FINISH GRADE 12 16" SQUARE CONC. PAD TROWEL. SMOOTH AND EDGE 13 C.I. WASTE LINE LENGTH TO SUITE. 14 WASTE UNE 15 1/8 BEND IF CLEANOUT OCCURS AT END OF LINE �} CLEANOUT DETAILS N.T.S. MAKE 1/2" BRANCH TO TRAP AUTOMATIC TRAP PRIMER VALVE PRIMER OFF TOP OF DOMESTIC WITH INTEGRAL AIR GAP. COLD WATER BRANCH PIPE TO PROVIDE DISTRIBUTION UNIT(S) FIXTURE(S). INSULATE PIPE r1h WHERE MORE THAN ONE TRAP IS UPSTREAM OF TRAP PRIMER, BUT SERVED BY ONE TRAP PRIMER NOT DOWNSTREAM. VALVE. LOCATE TRAP PRIMER WHERE AN INSTALL TRAP PRIMER UNES ACCESS DOOR (REFER TO DOWNSTREAM OF TRAP PRIMER SPECIFICATIONS) CAN BE PLACED OR DISTRIBUTION UNIT USING 1/2" IN FRONT OF IT IN AN ACCESSIBLE TYPE "K" SOFT COPPER TUBING. LOCATION. INSTALL PRIMER INSTALL WITHOUT KINKS, AND MINIMUM 6" ABOVE FLOOD RIM OF SLOPE CONTINUOUSLY TOWARDS FIXTURE BEING SERVED. FLOOR DRAIN. PROVIDE FLOOR DRAIN BODY OR CONCRETE FLOOR P -TRAP WITH THREADED TRAP PRIMER CONNECTION. PROVIDE , 4: IF PIPE IS BELOW FLOOR SLAB FITTINGS AND ADAPTERS AS ° ' ON GRADE, PROVIDE 1/2" REQUIRED TO MAKE WATER -TIGHT ELASTOMERIC INSULATION FROM CONNECTION TO DRAIN. PRIMER CONNECTION TO 1" ABOVE FLOOR SLAB. PROVIDE TRAP PRIMERS WHERE SHOWN ON FLOOR PLANS, AND WHERE REQUIRED BY LOCAL AUTHORITIES. PIPING ARRANGEMENT SHOWN IS SCHEMATIC: ADJUST TO SUITE AUTHORITIES AND FIELD CONDITIONS. TRAP PRIMER IN WET WALL N.T.S. wa /i Atoll, �/� 'AiTELTU DESIGN (s�,` 151 Si�VlL.A AVENUc SIiITc 200 CORAL GABLES, FL 33134 OFFICE: (305) 442 -1188 FAX: (305) 445 -1509 VVWW. ADCINTERNATIONAL.NET STATE OF FLORIDA AR- 0010536 RAYMUNDO FEITO, R.A. AA- CO01315 Architect • Sea[/Signature Construction Documents for: SUM PHN at: ONE 7000 PLACE SUITE: PHN 7th FLOOR 7000 SW 62nd AVENUE SOUTH MIAMI, FL 33143 Issue Date & Issue Description Drawn By Checked By 01 12, 0 4 09 AC AR PERMIT ISSUE 02 01 X13/10 AC AR PRICING SUBMITTAL Z_ Z a W a 0 W 0 O R W F- Date & Delta Description Drawn By Checked By f Z Qz a 0 UJ v W H Q Client Information HEALTHCARE REALTY 2601 SW 37th AVENUE SUITE 805 MIAMI, FL 33133 OFFICE: (305) 446 -3666 Project Number 09148 CAD File Name ONE 7000 PLACE - SUITE PHN DescnMPIN NOTES AND DETAILS on Scale AS NOTED Consultant • Seal/Signature ENG EERTNG DA�,Ti Z «' 0 RP. ., 21 SW 102G:M'i 1 0 0ffice:, ).8 92a �Q z Fax: (305) 22 -5196 co pgengineerdesignftellsouth.net 2 Z) P=2o ,J STATE OF FLORIDA M ERGUIN CAPOTE P.E. No. 62487 LUIS O. PEREZ, PE P.E. No. 62586 i