10-323-011A3
A SECTION
TYPICAL INTERIOR PARTITION
2.1'
A -f
0
s
EXISTING STRUCTURE
20 GA. CLIP W/ (2) 0.125 FAST
TRACK PINS INTO EXIST. SLAB
(2) #10 TEK SCREWS INTO BRACE
3/4" CASE HARDENED FASTRACK NAILS
@ 12" O.C.
2 1/2" 25 GA. BRACE @ 6' -0"
O.C. MAX
20 GA. CLIP W/ (2) #10 TEK
SCREWS EA. LEG
9' -0" A.F.F.
ACOUSTICAL CEILING
2 1/2- 25 GA. CONT. STUD ATTACHED
TO EACH VERT. STUD W (2)
#10 TEK SCREWS
WALL ANGLE
1/2" DRYWALL OVER 3 5/8 ", 25 GA.
MTL. STUDS @ 24" O.C.
NOTE:
INTERIOR PARTITION HEIGHT
6" ABOVE OF SUSPENDED
ACOUSTICAL CEILING SYSTEM,
TYPICAL.
1 TYPICAL INTERIOR PARTITION
ACHED TO SLAB WITH
FASTRACK PINS @ 24" O.C.
STUD TO TRACK W/ (1) #10
V EA. SIDE
BE SELECTED.
IISH TO BE SELECTED,
0' -0" _
FINISH FLOOR
SCALE: N.T.S.
Al q 91
0' -0"
FINISH FLOOR
EIS
P L U M B I N G N 0 T E S
C�D
1
WATER CLOSET: AMERICAN STANDARD, CADET ADA 16 -1/2 "H ELONGATED TOILET, MODEL 2998.012
0-
C:> RY
17" RIM HT. TOILET COMPLETE, HANDICAP ACCESIBLE, WHITE. SEE NOTE BELOW
®
2
HANDICAP ACCESIBLE LAVATORY: AMER. STANDARD 0355.012 WALL HUNG, WHT. WITH
GRAB BAR
c.T
LEVER OPERATED, POLISHED CHROME FAUCET NO. 5502.170 & GRID DRAIN. PROVIDE
UNDERCOUNTER H.C. KNEE SPACE PROTECTION BY TRUEBRO MODEL #102 OR EQUIVALENT
I�
3
TOILET PAPER DISPENSER: BOBRICK B -2740, SURFACE – MOUNT.
4
PAPER TOWEL DISPENSER W/ RECEPTACLE: BOBRICK, RECESSED,
NOTE:
# B -366 STAINLESS STEEL
GRAB BAR SHALL BE SECURED
5
MIRROR: BOBRICK B- 294 -1630 HANDICAP,TILT TYPE
®
6
N/A
7
GRAB BAR: 1 -1/2" DIA. x 42" LONG, STEEL, WALL MOUNTED, SEE DTL. 3 THIS SHT.
8
GRAB BAR: 1 -1/2" DIA. x 36" LONG, STEEL, WALL MOUNTED, SEE DTL. 3 THIS SHT.
9
FLOOR DRAIN: JOSAM 30000 -7A, ADJUST, NICKEL BRONZE STRAINER. PROVIDE TRAP
PRIMER CONNECTION FROM NEAREST LAVATORY P —TRAP TO JR. SMITH NO. 2698
O
10
SOAP DISPENSER: BOBRICK B -2111, SURFACE – MOUNT. ® HANDICAP HEIGHT.
/w
DETAIL
@ PICTURE WINDOW
F///,
8' -0" ELEV
BOTT. OF
D.W. CLG,
SECTION
@ HEADER
DRYWALL OVER MTL. STUD INTERIOR WALL.
MTL. FRAME, TO MATCH DOOR FRAME.
1/2" THICK CLEAR TEMPERED GLASS PANEL.
SCALE: N.T.S. I
,4,11' -0" A.F.F.
BUILDING STRUCTURE
EXISTING STRUCTURE ABOVE
SEALANT
-TRACK ATTACHED TO SLAB WITH
(2) .125 FASTRACK PINS @ 24" O.C.
-1/2" DRYWALL OVER 2 1/2", 25 GA.
MTL. STUDS @ 16" O.C. (NOTE: PROVIDE
DIAGONAL BRACING) @ 48" O.C. MAX.
a.8' -0" ELEV.
'rBOTT. OF ACOUSTICAL CLG. SYSTEM
,LBOTTOM OF HEADER
`'ELEV. +7' -6" A.F.F.
-PROPOSED DRYWALL HEADER
-WALL BEYOND
SCALE: N.T.S. I
SCALE: N.T.S.
a0
= 4 =
� � N
N
=I
i%
1±� V.I,F.
\,� EXISTING STRUCTURE
L20 GA. CLIP W/ (2) 0.125 FAST
TRACK PINS INTO EXIST. SLAB
(2) #10 TEK SCREWS INTO BRACE
3/4" CASE HARDENED FASTRACK NAILS
@ 12" O.C.
2 1/2" 25 GA. BRACE @ 6' -0"
O.C. MAX
20 GA. CLIP W/ (2) #10 TEK
SCREWS EA. LEEG
9' -0" A.F.F. _
ACOUSTICAL CEILING
2 1/2" 25 GA. CONT. STUD ATTACHED
TO EACH VERT. STUD W (2)
#10 TEK SCREWS
WALL ANGLE
1/2" DRYWALL OVER 2 1/2 ", 25 GA.
MTL. STUDS @ 24" O.C.
NOTE:
INTERIOR PARTITION HEIGHT
6" ABOVE OF SUSPENDED
ACOUSTICAL CEILING SYSTEM,
TYPICAL.
TRACK ATTACHED TO SLAB WITH
(2) .125 FASTRACK PINS @ 24" O.C.
ATTACH EA. STUD TO TRACK W/ (1) #10
TEK SCREW EA. SIDE
-BASE TO BE SELECTED.
FLOOR FINISH TO BE SELECTED.
0' -0"
FINISH FLOOR
1 SECTION
A — 8 TYPICAL INTERIOR PARTITION
iplam
DETAIL
@ RESTROOM LAVATORY
EXIST. STRUCTURE ABOVE. - Ar
ATTACHED W/ TRACKFAST CASE HARDENED
NAILS @ 16" O.C. MIN. 3/4" IMBEDMENT
2 1/2", 20 GG. MTL.
STUD FRAMING @16" O.C.
PROVIDE CROSS BRACING
2 1/2, 25GA. MTL. STUDS
@ 16" O.C. STAGGERED.
9' -0" A.F.F.
PROP. ACOUST. CLG.
8' -6" A.F.F. �h
BOT. OF TOP MULION,
ALIGN WITH DOOR
PROPOSED ALUMINUM & GLASS BUILDING
STANDARD INTERIOR STOREFRONT PARTITION
W/ 1/2" CATEGORY II SAFETY GLASS INSTALLED
PER MANUFACTURER'S RECOMENDATIONS TYP.
2 1 SECTION
SCALE: N.T.S. �-8 @ SIDELITE/INTERIOR STOREFRONT ALUMINUM SCALE: N.T.S.
A GLA SS PARTITION
Al-7/8" I.D. TO ACCOMMODATE
NEARLY ALL 1-1/4" AND 1 -1/2"
CAST BRASS, SEMI –CAST BRASS,
AND P.V.C. P –TRAPS (DOES NOT
FIT SCHEDULE 40 P,V.C.)
A2. 10" TAIL PIPE (TRIM AS NEEDED
TO COVER ENTIRE PIPE)
A310" WASTE ARM (TRIM AS NEEDED
TO COVER ENTIRE PIPE)
A TAIL PIECE & WASTE ARM COVERS
OVERLAP J -BEND TO PROVIDE A
CLEAN FINISHED APPEARANCE.
A5NUT STRUCTURE ENCLOSURES ON
ENDS OF J –BEND COVER ALLOW
ACCOMMODATION OF VARIOUS
J –BEND SIZES.
66. ELBOW ON INSULATION IS
ENLARGED TO ACCOMMODATE
FEMALE ELBOW ON WASTE LINE.
Q7. ALLOWANCE FOR CLEAN OUT
NUT DEPTH AND EASY ACCESS
TO CLEAN OUT BY REMOVING
J –BEND COVER.
A83" WATER LINE EXTENSION
FOR FULL COVERAGE OF
EXTENDED SUPPLY PIPES.
QWATER VALVE INSULATION
COMPLETELY COVERS KEYED
AND STANDARD ANGLE STOPS.
10. 10" SUPPLY LINE COVER.
AOFFSET P –TRAP COVER FITS
TRAP ON CERTAIN HANDICAP
LAVATORIES, (ORDER
SEPARATELY) PART 500HS.
SCALE: N.T.S.
SIGNAGE IDENTIFYING BATHROOM ACCESSIBILITY
@ 60" A.F.F. TO CENTERLINE OF SIGN
& CONFORMING TO SECTION 4.30 OF
THE FLORIDA ACCESSIBILITY CODE.
SIGN DETAIL
@ RESTROOM LAVATORY
P--- c�+J
O0
�-N
U:w
o
4 w
z
O J
co Ld
w
z
w
v
SCALE: N.T.S.
METAL STUD
GYPSUM WALL BOARD
CONCEALED ANCHOR PL. FOR
STUD WALL, W/ 256 SERIES
ANCHOR PL. W/ BOBRICK
GRAB BAR #10800 /BOB
DETAIL
@ GRAB BAR
cr-
a a
m m
M m
a
Of
2„
1 1/2"
0-
0
4; p^ I~
0-
C:> RY
GRAB BAR
c.T
L`
`` .
M
M
(p
r7
NOTE:
GRAB BAR SHALL BE SECURED
AS TO
WITHSTAND A LOAD OF
NOT LESS
THAN 250 LBS. APPLIED AT ANY
POINT AND IN ANY DIRECTION.
SCALE: N.T.S.
'HEALTHCARE REALTY
2601 SW 37th AVENUE
SUITE 805
MIAMI, FL 33133
OFFICE: (305) 446 -3666
_
..................... ......_....,.......................................... ........................_......
Project Number
09148
CAD File Name
ONE 7000 PLACE - SUITE PHN
Description
TYPICAL WALL SECTIONS & DETAILS
Scale
N.T.S.
...... ..... ..........................
Consultant . Seal /Signature
9OF11