10-323-004GENERAL NOTES USE AND INTERPRETATION OF THIS DRAWING: 1. GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION, AIA DOCUMENT A201 ARE A PART OF A CONTRACT DOCUMENTS AS DESdRIBE USE AND INTENT OF THE DRAWINGS. THE CONTRACT DOCUMENTS INCLUDE NOT ONLY THE DRAWINGS, BUT ALSO THE OWNER- CONTRACTOR AGREEMENT, CONDITIONS OF THE ISSUEDAArTER EXECUTION SPECIFICATIONS, ADDENDA, DCONTRACT AND MODIFICATIONS DOCUMENTS ARE COMPLEMENTARY, AND WHAT IS REQUIRED BY ANY ONE SHALL BE BINDING AS IF REQUIRED BY ALL. WORK NOT COMPLETELY DELINEATED HEREON SHALL BE CONSTRUCTED OF THE SAME MATERIALS AND DETAILED SIMILARLY AS WORK SHOWN MORE COMPLETELY ELSEWHERE IN THE CONTRACT DOCUMENTS. 2. BY USE OF THE DRAWINGS FOR CONSTRUCTION OF THE PROJECT, THE OWNER REPRESENTS THAT HE HAS REVIEWED AND APPROVED THE DRAWINGS, AND THAT THE CONSTRUCTION DOCUMENT PHASE OF THE PROJECT IS COMPLETE. THE CONTRACTOR REPRESENTS THAT HE HAS VISITED THE SITE, FAMILIARIZED HIMSELF WITH THE LOCAL CONDITIONS, VERIFIED FIELD DIMENSIONS AND CORRELATED HIS OBSERVATIONS WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. 3. THE CONTRACT SUM AND THE CONTRACT TIME MAY BE CHANGED ONLY BY CHANGE ORDER TO THE CONTRACTOR SIGNED BY THE OWNER AND THE ARCHITECT. ANY WORK PERFORMED IN VARIANCE WITH THE CONTRACT DOCUMENTS AND NOT COVERED BY THE ARCHITECT'S WRITTEN ORDER FOR A MINOR CHANGE IN THE WORK OR A CHANGE ORDER, WILL NOT BE ACCEPTED. 4. AS INSTRUMENTS OF SERVICE, ALL DRAWINGS, SPECIFICATIONS AND COPIES THEREOF FURNISHED BY THE ARCHITECT ARE HIS PROPERTY. THEY ARE TO BE USED ONLY FOR THIS PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT. CHANGES TO THE DRAWINGS MAY ONLY BE MADE BY THE ARCHITECT. ANY SUBMISSION OR DISTRIBUTION WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ARCHITECT MAY BE CONSTRUED AS DEROGATION OF THE ARCHITECT'S COPYRIGHT OR OTHER RESERVED RIGHTS. A. D. A.: ALL WORK SHALL BE CONSTRUCTED IN ACCORDANCE WITH A.D.A. ACCESSIBILITY GUIDELINES AS SET FORTH IN THE AMERICANS WITH DISABILITIES ACT HANDBOOK. AS PUBLISHED BY THE EQUAL EMPLOYMENT OPPORTUNITY COMMISSION AND THE U.S. DEPARTMENT OF JUSTICE ON OCTOBER 1991. THE CONTRACTOR AND SUBCONTRACTORS SHALL BE RESPONSIBLE FOR THE IMPLEMENTATION OF SUCH. �. BASED ON THE FLORIDA BUILDING CODE 2007 ED. OCCUPANCY TYPE: OFFICE BUILDING. OCCUPANCY USE: GENERAL OFFICE (BUSINESS GROUP B) BUILDING HEIGHT: APPROX. 14 STORIES. BUILDING TYPE II - PROTECTED APPLICABLE CODES - FLORIDA BUILDING CODE, EXISTING BUILDING (FBC -EB) 2004 EDITION WITH 2005 AND 2006 SUPPLEMENTS. - FLORIDA BUILDING CODE, BUILDING (FBC -B) 2004 EDITION WITH 2005 AND 2006 SUPPLEMENTS. - FLORIDA BUILDING CODE, MECHANICAL (FBC -M) 2004 EDITION WITH 2005 AND 2006 SUPPLEMENTS. - FLORIDA BUILDING CODE, PLUMBING (FBC -P) 2004 EDITION WITH 2005 AND 2006 SUPPLEMENTS. - FLORIDA FIRE PREVENTION CODE (FFPC) 2004 EDITION. - NATIONAL ELECTRICAL CODE (NEC) 2005 EDITION. D 0 0 R S OEXISTING DOORS TO REMAIN. 1 PROPOSED INTERIOR DOOR. �J 3' -0" X 7' -0" X 1 -3/4" SOLID CORE WOOD DOOR. DOOR: BUILDING STANDARD. PREFINISHED, FINISH TO MATCH EXISTING. FRAME: HOLLOW MTL.(ALUMINUM) RELOCATED INTERIOR DOOR. 0PROPOSED INTERIOR DOOR HVAC LEGEND NEW A/C SUPPLY -AIR GRILLE. NEW A/C RETURN -AIR GRILLE. ONEW BLDG. STAND. THERMOSTAT, TYP. NOTE: SYMBOLS ARE FOR REFERENCE ONLY, REFER TO PARTICULAR BLDG. DISCIPLINE SHEETS FOR SPECIFIC FIXTURE TYPES, AND SPECIFICATIONS. DOOR HARDWARE NOTES NOTES: A.) ALL LOCKS MUST BE TO THE LANDLORDS MASTER KEY SYSTEM. B.) ALL RE- KEYING BY TENANT MUST BE COORDINATED THROUGH LANDLORD'S BUILDING MGNT. OFFICE. C.) PROVIDE WALL MOUNTED DOME STOPS 0 EACH DOOR. D.) HARDWARE SHALL COMPLY WITH ARTICLE 515.3 (F) 3AA OF F.B.C. E.) ALL HARDWARE TO BE US 26 FINISH (BRUSHED CHROME FINISH) F.) PROVIDE DOOR FRAMES PER BLDG. STANDARD. G.) CONTRACTOR SHALL PROVIDE HARDWARE PRODUCT INFO. FOR ARCHIT. REVIEW PRIOR TO PURCHASE OF HARDWARE. H.) ALL DOOR HARDWARE SHALL BE A.D.A. APPROVED LEVER HANDLE. 1.) EGRESS CONTROLLED DOORS SHALL COMPLY W/ N.F.P.A. 101,5 -2.1.5 J.) DOORS THAT LEAD TO TENANT SPACE TO HAVE ACCESS CONTROL HARDWARE AND SHALL COMPLY WITH THE PROVISIONS OF NFPA 101-4.2.1.6.2. DOOR A: SHALL BE CONTROLLED WITH THE USE OF A MAG -LOCK TYPE LOCKING DEVICE THAT SHALL PERMIT INGRESS WITH THE USE OF A CARD SWIPE AND SHALL PERMIT EGRESS BY MEANS OF A MOTION SENSOR AS YOU APPROACH THE DOORS, OR A RELEASE DEVICE THAT READS: "PUSH TO EXIT ". THIS SYSTEM SHALL ALSO RELEASE AND ALLOW EGRESS UPON ACTIVATION OF FIRE ALARM. SEE ENGINEERING DRAWINGS FOR MORE DETAILS. DOOR B: SHALL BE CONTROLLED BY THE USE OF AN ELECTRIC STRIKE TYPE LOCKING DEVICE THAT SHALL PERMIT INGRESS WITH THE USE OF A CARD SWIPE AND SHALL PERMIT EGRESS BY MEANS OF A MANUAL LEVER TYPE HANDLE. TYP. SEE`, ENGINEERING DRAWINGS FOR MORE DETAILS. K.) DOORS FROM THE STAIRS TO THE COMMON AREA CORRIDOR ARE EXISTING TO REMAIN AND INSTALLED UNDER PREVIOUS PERMIT. DOORS TO HAVE ACCESS CONTROL HARDWARE AND SHALL COMPLY WITH NFPA 101- 7.2.1.5.7.1. WALL LEGEND DENOTES EXISTING BUILDING STRUCTURE TO REMAIN DENOTES EXISTING INTERIOR` PARTITION TO REMAIN. r DENOTES NEW INTERIOR PARTITION REFER TO SECTION 1, ON SHEET A -8. __________________________ DENOTES DEMOLITION WALL LEGEND 1❑ ELECTRICAL LEGEND BLDG. STANDARD SCHLAGE COMBINATION TELEPHONE /DATA OUTLET. ("RATIVE DUPLEX ELECTRICAL RECEPTACLE, TYP. 0__ QUAD ELECTRICAL RECEPTACLE, TYP. GFI DUPLEX RECEPTACLE, G.F.I.,TYP. [ J 1 4 SQ. -IN. J -BOX. it NEW "E" EXISTING "R" REMOVE NOTE: SYMBOLS ARE FOR REFERENCE ONLY, REFER TO PARTICULAR BLDG. DISCIPLINE SHEETS FOR SPECIFIC FIXTURE TYPES, AND SPECIFICATIONS. DOOR HARDWARE NOTES NOTES: A.) ALL LOCKS MUST BE TO THE LANDLORDS MASTER KEY SYSTEM. B.) ALL RE- KEYING BY TENANT MUST BE COORDINATED THROUGH LANDLORD'S BUILDING MGNT. OFFICE. C.) PROVIDE WALL MOUNTED DOME STOPS 0 EACH DOOR. D.) HARDWARE SHALL COMPLY WITH ARTICLE 515.3 (F) 3AA OF F.B.C. E.) ALL HARDWARE TO BE US 26 FINISH (BRUSHED CHROME FINISH) F.) PROVIDE DOOR FRAMES PER BLDG. STANDARD. G.) CONTRACTOR SHALL PROVIDE HARDWARE PRODUCT INFO. FOR ARCHIT. REVIEW PRIOR TO PURCHASE OF HARDWARE. H.) ALL DOOR HARDWARE SHALL BE A.D.A. APPROVED LEVER HANDLE. 1.) EGRESS CONTROLLED DOORS SHALL COMPLY W/ N.F.P.A. 101,5 -2.1.5 J.) DOORS THAT LEAD TO TENANT SPACE TO HAVE ACCESS CONTROL HARDWARE AND SHALL COMPLY WITH THE PROVISIONS OF NFPA 101-4.2.1.6.2. DOOR A: SHALL BE CONTROLLED WITH THE USE OF A MAG -LOCK TYPE LOCKING DEVICE THAT SHALL PERMIT INGRESS WITH THE USE OF A CARD SWIPE AND SHALL PERMIT EGRESS BY MEANS OF A MOTION SENSOR AS YOU APPROACH THE DOORS, OR A RELEASE DEVICE THAT READS: "PUSH TO EXIT ". THIS SYSTEM SHALL ALSO RELEASE AND ALLOW EGRESS UPON ACTIVATION OF FIRE ALARM. SEE ENGINEERING DRAWINGS FOR MORE DETAILS. DOOR B: SHALL BE CONTROLLED BY THE USE OF AN ELECTRIC STRIKE TYPE LOCKING DEVICE THAT SHALL PERMIT INGRESS WITH THE USE OF A CARD SWIPE AND SHALL PERMIT EGRESS BY MEANS OF A MANUAL LEVER TYPE HANDLE. TYP. SEE`, ENGINEERING DRAWINGS FOR MORE DETAILS. K.) DOORS FROM THE STAIRS TO THE COMMON AREA CORRIDOR ARE EXISTING TO REMAIN AND INSTALLED UNDER PREVIOUS PERMIT. DOORS TO HAVE ACCESS CONTROL HARDWARE AND SHALL COMPLY WITH NFPA 101- 7.2.1.5.7.1. WALL LEGEND DENOTES EXISTING BUILDING STRUCTURE TO REMAIN DENOTES EXISTING INTERIOR` PARTITION TO REMAIN. r DENOTES NEW INTERIOR PARTITION REFER TO SECTION 1, ON SHEET A -8. __________________________ DENOTES DEMOLITION WALL LEGEND 1❑ TENANT ENTRY: BLDG. STANDARD SCHLAGE ARCHITECTURAL DESIGN ("RATIVE CYLINDER, ON DOOR ONLY, KEYED TO MATCH INTERIOR LOCK SET. aOFFICE BLDG. STANDARD SCHLAGE INTERIOR LOCK SET : LOCK WITH REMOVABLE CORE CYLINDERS. g•'�1 f TBS ❑OFFICE 3 WWW. ADCINTERNATIONAL.NET INTERIOR PASSAGE SET: INTERIOR MILLWORK NOT USED. LATCH SET- 5] ELECTRONIC BUZZER NOT USED. LATCH SET: STATE OF FLORIDA A 010536 SELF CLOSING NOT USED. a DOOR HINGE: [7] HINGES: BUTT HINGES, HAGER, FINISH: US26. a DOOR STOPS: HAGER -241 F FLOOR MOUNTED DOME STOPS @ ALL DOORS. 1-91 DOOR CLOSERS: BLDG. STANDARD (ENTRY DOORS ONLY) HSILENCERS: NOT USED O „N„ „E„ „R„ "RL" LIGHTING CEILING LEGEND PROPOSED BUILDING, STANDARD 2' X 2' ACOUSTICAL CEILING. PROPOSED BUILDING STANDARD 2' x 4' - 18 CELL PARABOLIC FLUORESCENT LIGHT FIXTURE. CONTRACTOR SHALL COORDINATE FOR FIXTURE TYPE. PROPOSED BUILDING STANDARD 2' x 2' - 9 CELL PARABOLIC FLUORESCENT LIGHT FIXTURE. CONTRACTOR SHALL COORDINATE FOR FIXTURE TYPE. PROPOSED HI —HAT TYPE LIGHT FIXTURE NEW EXISTING REMOVE N101D RELOCATED NOTE: SYMBOLS ARE FOR REFERENCE ONLY, REFER TO PARTICULAR BLDG. DISCIPLINE SHEETS FOR SPECIFIC FIXTURE TYPES, AND SPECIFICATIONS. surm FM at: ONE 7000 PLACE SUITE: PHN 7th FLOOR 7000 SW 62nd AVENUE SOUTH MIAMI, FL 33143 Issue Date & Issue Description Drawn By Checked By ? 01..r. 12/041­09 _.._.._._ -_ -___ 02..... 01 13 10 AC AR_..._ .../ 1 ......................... ... PRICING SUBMITTAL 03 01 21 10 AC AR Client Information HEALTHCARE REALTY 2601 SW 37th AVENUE SUITE 805 MIAMI, FL 33133 OFFICE: (305) 446 -3666 Project Number 09148 CAD File Name ONE 7000 PLACE - SUITE PHN Description GENERAL NOTES & LEGENDS Scale 1/4" =1'-0" Consultant Seal /Signature ' A=01 �r� m =' 2 OF 11 } ARCHITECTURAL DESIGN ("RATIVE r 151 SEVILLA AVENUE, SUITE 200 CORAL GABLES, FL 33134 OFFICE: (305) 442 -1188 FAX: (305) 445 -1509 g•'�1 f WWW. ADCINTERNATIONAL.NET STATE OF FLORIDA A 010536 RAYMUNDO FEITO, R.A. AA- CO01315 Architect • Seal /Signature Construction Documents for: surm FM at: ONE 7000 PLACE SUITE: PHN 7th FLOOR 7000 SW 62nd AVENUE SOUTH MIAMI, FL 33143 Issue Date & Issue Description Drawn By Checked By ? 01..r. 12/041­09 _.._.._._ -_ -___ 02..... 01 13 10 AC AR_..._ .../ 1 ......................... ... PRICING SUBMITTAL 03 01 21 10 AC AR Client Information HEALTHCARE REALTY 2601 SW 37th AVENUE SUITE 805 MIAMI, FL 33133 OFFICE: (305) 446 -3666 Project Number 09148 CAD File Name ONE 7000 PLACE - SUITE PHN Description GENERAL NOTES & LEGENDS Scale 1/4" =1'-0" Consultant Seal /Signature ' A=01 �r� m =' 2 OF 11