Loading...
13-96R-056O BS e � 0 CWPe-j 7 6' MIN #14GND TO CONTROL —� EQUIPMENT PULL BOX #6GND -e TO FACP —'S TO TBB #6GND 2 GRO4INDINQ DETAIL E41 N.T.S. NN(TE ALL GROUNDING INSTALLATIONG SHALL COMPLY WITH NEC ARTICLE 250. O 10 FT. LONG x V DIAMETER COPPER DRIVEN GROUND ELECTRODE. zO ADDITIONAL ELECTRODE AS REQUIRED BY NEC 250.56. O CONNECTION TO METALIC COLD WATER PIPE. O EXOTHERMIC CONNECTION (TYPICAL) O 3/0 EXOTHERMIC CONNECTION. ELECTRICALLY CONTINUOUS STEEL REINFORCING BAR IN BOTTOM OF BUILDING FOUNDATION IN DIRECT CONTACT WITH EARTH, O ATTACH GROUND BAR TO GROUNDING CONDUCTOR USING SOLID CABLE TO FLAT BAR CONNECTOR. O MAKE CONNECTION TO METALLIC COLD WATER ENTRANCE PIPE BEFORE FIRST VALVE WITH HEAVY DUTY BRONZE GROUND CLAMP. O PROVIDE (1) #4/0 BONDING JUMPER AROUND FIRST VALVE. O#3/0 GND IN 1"C. aCONNECTION TO NATURAL GAS PIPE. a NOT USED. e#1/0 GND IN 3/4 "C. qD #8 GND IN 1/2 "C. 6 14 CONNECTION TO CONCRETE- ENCASED ELCTRODE WITH DIRECT BURIAL LISTED CLAMP. is #4 GND IN 3/4 "C. e#14 GND IN 1/2 "C. PATIO MAIN F3 5 OF 6 1200A M.C.B. MAIN D SERVICE 6 OF 6 ENTRANCE RATED 400A M.C.B. TRYSTAR ROTARY SERVICE GENERATOR DOCKING ENTRANCE RATED STATION TRYSTAR ROTARY GENERATOR DOCKING STATION 0 4 ' 0 ■GROUND r; o� ELECTRICAL RISER NOTES 1. CONTRACTOR TO PROVIDE A PERMANENT PLAQUE FOR EACH NORMAL MAIN AND INDICATE LOCATION OF ALL OTHER MAINS AS PER NEC 225.37. 2. CONTRACTOR SHALL PROVIDE FLASH HAZARD MARKING AS PER NEC 110.16. 3. PROVIDE IDENTIFICATION OF DISCONNECTING MEANS PER NEC 110.22. FEEDER SCHEDULE F1 (3) SETS OF 4 "C. EACH WITH (4) #600KCMIL F2 4 "C. WITH 4 #500KCMIL F3 REFER TO ELECTRICAL RISER NOTES ABOVE. Fa 4 "C. WITH 4 #500KCMIL AND (1) #3GND F5 3" EMPTY CONDUIT WITH PULLSTRINGS Fs 1 1/4 "C. WITH (4) #3 AND (1) #8GND O 2 "C. WITH (4) #3 FS 2 "C. WITH (4) #1 AND (1) #6GND Fa 3 "C. WITH (4) #3/0 AND (1) #6GND 2 "C. WITH (4) #3 AND (1) #8GND 1 " EMPTY CONDUIT WITH PULLSTRINGS 19 2" EMPTY CONDUIT WITH PULLSTRINGS 3" EMPTY CONDUIT WITH PULLSTRINGS Q NOT USED. SEE PANEL SCHEDULE. 19 3 "C. WITH (4) #3/0 1 1/4" RGS 19 (3) SETS OF 4 "C. EACH WITH (4) #600KCMIL & (1) #3/0 GND 2 SETS OF 3"C. EACH WITH (4) #350KCMIL 2 "C. WITH (4) #1 AND (1) #1 GND #1/0 SECONDARY BONDING GND IN 2 "C. TO NEAREST BUILDING STEEL AND CWP. Q 3/4 "C. FOR EPO SHUNT TRIP WIRES. PROVIDE STEP —UP TRANSFORMER ON CONCRETE HOUSEKEEPING PAD. ' ARKING ROOF CHILLER EQUIP OIL r77N 77777mm, BACK EXTERIOR FUTURE VAULT AREA 3, 3R O O ® 33R 208V//480V 225KVA XFMR 20 o O ■ s ■ ■ s ■ r 000 AWs — —O -- — G PNL -s--e. 0 CT ROOM EP01 EP03 TO LIGHT, POLES PNL PNL 101 '41 A' •—F •er�•0 �'J O.erro. VAULT ROOM VAULT CONTROL ROOM IT 128 ELECTRICAL ROOM 122 G 48OV, 3P /90A MCB PANEL FURNISHED BY VARIAN O mm 00 CONTROL PNL EQUIP. 'IT' PULL BOX 3P /200A OUT sL 3P /90A POWER CONDITIONER 88LX -50K- 70OA /VS FURNISHED BY VARIAN PNL PNL PNL 'GE' ' 1 E' "I CE' v PNL 'SL' G G -- ELECTRICAL RISER DIAGRAM 60OW INVERTER PHILIPS CHLORIDE Z1600 -120 PANEL "EDP" 1200A MLO, 120/208V, s0, 4W -- G G SCALE: N.T.S. 10 PNL PNL '4E' '4E2' 4 #3/0, 1 #6G — IN EXISTING 3"C 2 C E4.1 MAIN 4 OF 6 34&3R ROOF 4TH FLOOR 3RD FLOOR — PARKING GARAGE 2ND FLOOR — PARKING GARAGE FAULT CURRENT CALCULATIONS AT MAINS #1, 2. AND #3 120/208V, 30 MODULAR 32,552 AMPS S.C. VOLTAGE: 120/208V, 30 CABINET PUL NUMBER OF CONDUCTORS PER PHASE C: 1 ELEC 75' CONDUCTOR C VALUE: BOX ( #CONDUCTORS PER PHASE x C = ) 0 .0 DUCT f -FACTOR 'PD' I VD1 1 1 M __ 0.407 = G 48OV, 3P /90A MCB PANEL FURNISHED BY VARIAN O mm 00 CONTROL PNL EQUIP. 'IT' PULL BOX 3P /200A OUT sL 3P /90A POWER CONDITIONER 88LX -50K- 70OA /VS FURNISHED BY VARIAN PNL PNL PNL 'GE' ' 1 E' "I CE' v PNL 'SL' G G -- ELECTRICAL RISER DIAGRAM 60OW INVERTER PHILIPS CHLORIDE Z1600 -120 PANEL "EDP" 1200A MLO, 120/208V, s0, 4W -- G G SCALE: N.T.S. 10 PNL PNL '4E' '4E2' 4 #3/0, 1 #6G — IN EXISTING 3"C 2 C E4.1 MAIN 4 OF 6 34&3R ROOF 4TH FLOOR 3RD FLOOR — PARKING GARAGE 2ND FLOOR — PARKING GARAGE FAULT CURRENT CALCULATIONS AT MAINS #1, 2. AND #3 120/208V, 30 TRANSFORMER LET - THROUGH SHORT- CIRCUIT CURRENT I ' 32,552 AMPS S.C. VOLTAGE: 120/208V, 30 WIRE SIZE: #310 KCMIL NUMBER OF CONDUCTORS PER PHASE C: 1 CONDUCTOR LENGTH L: 75' CONDUCTOR C VALUE: 13,923 ( #CONDUCTORS PER PHASE x C = ) 0 .0 M - MULTIPLIER f -FACTOR f = 1.73 x L x IS 1.73 x 75 x 32,552 = = 1,46 C x EL_L 13923 x 20$ 1 1 M __ 0.407 = 1 + f 1 + 1.46 Is.c.A° Is.C. x M = 32,552 x 0.407 = 13,232 A RMS RMS MINIMUM BREAKER RATING = 1$,000 A.I.C. AT MAIN #4 TRANSFORMER LET - THROUGH SHORT- CIRCUIT CURRENT I ' 32,552 AMPS S.C. VOLTAGE: 120/208V, 30 WIRE SIZE: #3 NUMBER OF CONDUCTORS PER PHASE C: 1 CONDUCTOR LENGTH L: 75' CONDUCTOR C VALUE: 4,811 ( #CONDUCTORS PER PHASE x C = ) M - MULTIPLIER f -FACTOR f = 1.73 x L x IS C, 1.73 x 75 x 32,552 = C x EL-L 4811 x 208 = 4.22 1 __ _ 1 M _ = 0.192 1 + f 1 + 4.22 Is.c.A° IS.C. x M = 32,552 x 0.192 = 6,236 A RMS RMS MINIMUM BREAKER A.I.C. RATING = 10,000 A.I.C. AT MAIN #5 TRANSFORMER LET - THROUGH SHORT- CIRCUIT CURRENT I ' 32,552 AMPS VOLTAGE: S.C. 120/208V, 30 WIRE SIZE: #600 KCMIL NUMBER OF CONDUCTORS PER PHASE C: 3 CONDUCTOR LENGTH L: 150' CONDUCTOR C VALUE: ( #CONDUCTORS PER PHASE C 84,099 x = ) M - MULTIPLIER f -FACTOR f= 1.73 x L x IS c- 1.73 x 150 x 32,552 C x EL-L 84,099 x 208 = 0.4$3 M = 1 = 1 = 0.674 1 + f 1 + 0.483 IS.c.A= Is.c. x M = 32,552 x 0.674 = 21,950 A RMS RMS MINIMUM BREAKER A.I.C. RATING = 22,000 A.I.C. AT MAIN #6 TRANSFORMER LET - THROUGH SHORT- CIRCUIT CURRENT I ' 32,552 AMPS S.C. VOLTAGE: 120/208V, 30 WIRE SIZE: #500 KCMIL NUMBER OF CONDUCTORS PER PHASE C: 1 CONDUCTOR LENGTH L: 150' CONDUCTOR C VALUE: ( #CONDUCTORS PER PHASE x C = ) M - MULTIPLIER f - FACTOR f =1.73xLxIS, 150x32,552 -1.73x = 1.52 C x EL-L 26,706 x 208 M = 0.397 1 + f 1 + 1.52 IS.C.A= 'S.C. x M = 32,552 x 0.397 = 12,917 A RMS RMS MINIMUM BREAKER A.I.C. RATING = 14,000 A.I.C. EXTERIOR WALL MAIN MAIN MAIN 3OF6 2OF6 1 OF 33R 3313 33R F3 BMETERG 100 AM 0 0 0 400A CT METER CAN n<z� 200A 200A 200A � METER METER METER 100A METER 0 N 12 3 O NEW FP&L No. - Date - Revision 120/208V, 30 02/01/13 TRANSFORMER o (j City Comments Response Q10104/13 0 VE Revisions a 0 .0 M JN r G S & Design Services For The Built Environment 0 Atlanta Birmingham Cincinnati CoIum <bus Dallas Fort Lauderdale Knoxville Jackson Jacksonville Louisville Memphis Nashville Richmond Tampa G R E S H A M S M I T A N D P A R T N E R S 6030 Hollywood Blvd. Suite 210 Hollywood, Florida 33024 954. 981.9100 FIRMS FLORIDA CERT. NO. AAP000034/CA3806 B 26000797/LC26000'381 DELTA G CONSULTING ' ENGINEERS, INC. 707 N.E. 3rd AVE., SUITE 200 as FORT LAUDERDALE, FL. 33304 a '; (954) 527 -1112 �xa aar�; CA,#00009181 MUMR ffik PJT. MGR: MICHAEL H00 PROJECT #: 120717 .wa" m t I-- cY3 Uj .., `S Uj V O Q) Q 20bcz Q L X 0 W o �rM 0J✓ br_ 2�a to -:, z N \ SAI�J�UAN, �- ,:E, FLO}�ID `LIC,�NSE,1 #6100 DATE: REVISION No. - Date - Revision 1 Q03/15/13 02/01/13 Addendum #1 City Comments Response Q04/22/13 (j City Comments Response Q10104/13 - VE Revisions ELECTRICAL RISER DIAGRAM E4n1 ILE: 'ROJECT: 29080.00 )ATE: 1 1 /29/201 2