Loading...
13-96R (2)-041��TIAL FIRST FLOOR —NEW CONSTRUCTION POWER �L� SCALE: 1/4" = i' -0" Z 0 r—i Q D H G 0 0� 0 W W Uj U0 LLJ W V) KEYNOTES O RECEPTACLES IN ELEVATOR PIT. COORDINATE 29 'FOf SkAKERY REFER T6 V�NDOR v 0 EXACT LOCATION WITH ELEVATOR SUPPLIER DRAWINGS FOR FINAL CONNECTION. PRIOR TO ROUGH —IN. 30 FOR LASER. SEE KEY NOTE 31 FOR O PROVIDE CAMERA IN ELEVATOR CABINET. ADDITIONAL REQUIREMENTS. r COORDINATE WITH ELEVATOR SUPPLIER. 3t 3 POSITION SWITCH FOR LASER O COORDINATE EXACT LOCATION AND POWER CONTROL. REFER TO VARIAN REQUIREMENTS OF ABOVE CEILING WIFI DESIGNER'S DESK REFERENCE PAGE ROUTER WITH IT CONSULTANT. 4 -13 FOR ADDITIONAL INTERCONNECTION. O COORDINATE EXACT LOCATION OF CEILING 32 EMERGENCY POWER OFF. REFER TO 1, 2 VARIAN DESIGNER'S DESK REFERENCE MUSIC SYSTEM TO SHUT DOWN UPON PAGE 4 -13 FOR ADDITIONAL ACTIVATION OF FIRE ALARM SYSTEM. INTERCONNECTION. AND EDGE DDR O BATHROOM'S EXHAUST FAN TO BE CONNECTED DOCUMENTATION, PAGE 139 FOR AND CONTROLLED BY BATHROOM'S LIGHTS SWITCH SPECIFICVATIONS. BRANCH CIRCUIT AND LIGHT SWITCH. 33 FOR LASER AT CEILING. SEE KEY O GEF TO BE CONTROLLED BY GARAGE'S CO NOTE 31 FOR ADDITIONAL SENSOR. COORDINATE WITH MECHANICAL REQUIREMENTS. DRAWINGS. 34 INTRACRANIAL CAMERA. COORDINATE COORDINATE LAYOUT OF IT ROOM WITH IT POWER SUPPLY LOCATION AND CONSULTANT PRIOR TO ROUGH —IN OF INTERCONNECTIONS WITH VENDOR. RECEPTACLES. 35 PUSH BUTTON OPERATOR STATION. I� AHU PROVIDE WITH BUILT -IN DISCONNECT. COORDINATE WITH VERITAS COORDINATE WITH MECHANICAL CONTRACTOR. DOCUMENTATION FOR FINAL ...... . ...... CONNECTION. O PROVIDE 1/2 "C. WITH PULLSTRINGS FOR 36 INTERCOM. THERMOSTAT CONTROLS. COORDINATE WITH ��TIAL FIRST FLOOR —NEW CONSTRUCTION POWER �L� SCALE: 1/4" = i' -0" Z 0 r—i Q D H G 0 0� 0 W W Uj U0 LLJ W V) KEYNOTES O RECEPTACLES IN ELEVATOR PIT. COORDINATE 29 'FOf SkAKERY REFER T6 V�NDOR v 0 EXACT LOCATION WITH ELEVATOR SUPPLIER DRAWINGS FOR FINAL CONNECTION. PRIOR TO ROUGH —IN. 30 FOR LASER. SEE KEY NOTE 31 FOR O PROVIDE CAMERA IN ELEVATOR CABINET. ADDITIONAL REQUIREMENTS. r COORDINATE WITH ELEVATOR SUPPLIER. 3t 3 POSITION SWITCH FOR LASER O COORDINATE EXACT LOCATION AND POWER CONTROL. REFER TO VARIAN REQUIREMENTS OF ABOVE CEILING WIFI DESIGNER'S DESK REFERENCE PAGE ROUTER WITH IT CONSULTANT. 4 -13 FOR ADDITIONAL INTERCONNECTION. O COORDINATE EXACT LOCATION OF CEILING 32 EMERGENCY POWER OFF. REFER TO MOUNTED SPEAKER WITH AUDIO CONSULTANT. VARIAN DESIGNER'S DESK REFERENCE MUSIC SYSTEM TO SHUT DOWN UPON PAGE 4 -13 FOR ADDITIONAL ACTIVATION OF FIRE ALARM SYSTEM. INTERCONNECTION. AND EDGE DDR O BATHROOM'S EXHAUST FAN TO BE CONNECTED DOCUMENTATION, PAGE 139 FOR AND CONTROLLED BY BATHROOM'S LIGHTS SWITCH SPECIFICVATIONS. BRANCH CIRCUIT AND LIGHT SWITCH. 33 FOR LASER AT CEILING. SEE KEY O GEF TO BE CONTROLLED BY GARAGE'S CO NOTE 31 FOR ADDITIONAL SENSOR. COORDINATE WITH MECHANICAL REQUIREMENTS. DRAWINGS. 34 INTRACRANIAL CAMERA. COORDINATE COORDINATE LAYOUT OF IT ROOM WITH IT POWER SUPPLY LOCATION AND CONSULTANT PRIOR TO ROUGH —IN OF INTERCONNECTIONS WITH VENDOR. RECEPTACLES. 35 PUSH BUTTON OPERATOR STATION. I� AHU PROVIDE WITH BUILT -IN DISCONNECT. COORDINATE WITH VERITAS COORDINATE WITH MECHANICAL CONTRACTOR. DOCUMENTATION FOR FINAL CONNECTION. O PROVIDE 1/2 "C. WITH PULLSTRINGS FOR 36 INTERCOM. THERMOSTAT CONTROLS. COORDINATE WITH MECHANICAL CONTRACTOR AND LOCATION WITH 3i MOUNTED HI. REFER TO VENDOR ARCHITECTURAL ELEVATIONS. DRAWINGS FOR EXACT LOCATION. to PROVIDE 1/2 "C. WITH PULLSTRINGS FROM SECURITY CAMERA BACK TO HEAD END EQUIPMENT IN IT ROOM 128, JOORDINATE 1 WITH SECURITY VENDOR. 2 t t SERVICE ENTRANCE RATED ROTARY SWITCH WITH CAM LOCKS FOR PORTABLE GENERATOR CONNECTION. t2 VARIAN EQUIPMENT MAIN CIRCUIT BREAKERS. COORDINATE EXACT LOCATION WITH VARIAN PRIOR TO INSTALLATION AND LOCATION WITH RCHITECTURAL ELEVATIONS. IT LOOP SAW —CUT IN GROUND. PROVIDE 1/2" CONDUIT WITH PULLSTRINGS BACK TO GATE OPERATOR. COORDINATE EXACT LOCATION /REQUIREMENTS WITH GATE SUPPLIER. t4 VEHICLE LOOP DETECTOR. PROVIDE 1/2" CONDUIT WITH PULLSTRINGS BACK TO GATE OPERATOR. COORDINATE EXACT LOCATION /REQUIREMENTS WITH GATE SUPPLIER. is COORDINATE WITH MECHANICAL DRAWINGS AND CONTRACTOR FOR CONTROLS OF MOTORIZED DAMPER. 1s J —BOX FOR DATA MOUNTED IN CEILING SPACE FOR FUTURE USE. ROUTE 1" E.C. WITH PULLSTRINGS BACK TO IT 128. t� J —BOX FOR POWER MOUNTED IN CEILING SPACE FOR FUTURE USE. ROUTE 1" E.C. WITH PULLSTRINGS BACK TO ELEC. 122. to COORDINATE ALL CONDUIT PENETRATIONS OF VAULT AND BRACHY WITH VARIAN REPRESENTATIVE. 1s AHU PROVIDED WITH BUILT —IN DISCONNECT AND CONNECTED TO CU ON ROOF. COORDINATE WITH MECHANICAL DRAWINGS / CONTRACTOR. 20 IEC 60309, 30A, 250V POWER INLET POWERED BY ACCELERATOR CIRCUIT BREAKER PANEL. REFER TO VARIAN SITE DRAWINGS. COORDINATE 21 LOCATION WITH ARCHITECTURAL ELEVATIONS. MOUNT RECEPTACI WS AFF IN VAULT PER TRUEBEAM SITE INGS. 22 IN —USE AND X— USE WARNING LIGHTS (CONTRACTOR FURNISHED /VERITAS INSTALLED) TO RELAY JUNCTION BOX BY VARIAN. COORDINATE LOCATION WITH ARCHITECTURAL 23 ELEVATIONS. DOOR SAFETY INTERLOCKS (CONTRACTOR FURNISHED AND INSTALLED) TO RELAY 2 JUNCTION BOX BY VARIAN. COORDINATE LOCATION WITH ARCHITECTURAL ELEVATIONS. 24 RELAY J —BOX (VARIAN FURNISHED, 1 CONTRACTOR INSTALLED). REFER TO TRUEBEAM SITE DRAWINGS. COORDINATE LOCATION WITH ARCHITECTURAL ELEVATIONS. zs OBI SYSTEM EMERGENCY SHUT OFF — VERIFY 1 EXACT LOCATION WITH SUPPLIER. 2s PROVIDE OUTLET AND OUTLET COVER TO BE DARK BROWN IN COLOR. COORDINATE LOCATION WITH ARCHITECTURAL ELEVATIONS. 27 REMOTE GATE CONTROL - CONNECT TO GATE 1 i-YC 0,ki,- m-AI rl9AA1-s1- A WARNING LIGHTS. COORDINATE FINAL) /11 CONNECTION WITH VENDOR. �f__ AREA OF W KEY PLAN G 5 & Y CR) Design Services For The BuiIl Environment 0 Atlanta Bir €-gingham Cincinnati Col Limb us Dallas Fort Lauderdale K n o x v i I I e Jackson. ...lackSonviIIe Louisville Memphis N a s h v i I I e Richrnor€d Tampa 0 G R E S H A M SMITH AND P A R T N E R S 6030 Hollywood Blvd, Suite 210 Hollywood, Florida 33024 954.981.9100 FIRM'S FLORIDA CERT. Nth. AAP000034/CA3305 IB26000797/LC2600038 1 Ao�DELTA G CONSULTING ENGINEERS, INC. 707 N.E. 3rd AVE., SU1TE 200 FORT LAUDERDALE, FL. 33304 (954) 527 -1112 cA#00009181 PJT. MGR: MICHAEL H00 PROJECT #: 120717 _ ! m LJ .,.... 0 r U W U D m U) d- N N ®119aI�191g,y� ' /110 to ,r .� rC, JJ o! ST Tra OF 0 d1 CE' T{9E48100 yea vA N ►1 N CD Q REVISION 1 N 10/04/13 I.T. Revisions PARTIAL FIRST FLOOR NEW CONSTRUCTION POWER PLAN E3.1a FILE: PROJECT: 29080.00 DATE: 1 1/29/201 2 No, - Date - Revision 0 1 02/01/13 ;Addendum #1 Q03/15/13 City Comments Response U ' Q 03/29/13 City Comments Response r 1 N 10/04/13 I.T. Revisions PARTIAL FIRST FLOOR NEW CONSTRUCTION POWER PLAN E3.1a FILE: PROJECT: 29080.00 DATE: 1 1/29/201 2