Loading...
13-96R (2)-037EiE FI F NC 1. WI_ 2. WITH THIS NEW BUILDING'S FA SYSTEM. 3. ALL CONTROLS FOR ALARM SYSTEM SHALL BE AT MAIN PANEL. 0 KEY NOTES: o1 FLOW AND TAMPER DEVICES AS INDICATED ON 2 EXTEND 3/4" EMPTY CONDUIT FROM FIRE ALARM 3 #6 TO MAIN BUILDING GROUND. THE FIRE SPRINKLER SYSTEM DRAWINGS. O COMMUNICATOR TRANSMITTER TO MAIN TELEPHONE O BACKBOARD. F RE ALARM RISER DIAGRAM FIRE ALARM SY TEM NOTES 1. THE MAIN FIRE ALARM CONTROL PANEL SHALL BE A MICROPROCESSOR BASE SYSTEM WITH ADDRESSABLE, INTELLIGENT DETECTORS. ADDRESSABLE CONTROL RELAY AND MONITOR MODULES, VISIBLE AND AUDIBLE SYSTEM ANNUCIATORS AND OTHER SYSTEM CONTROLLED DEVICES AS REQUIRED. 2. PROVIDE REMOTE POWER SUPPLY AS INDICATED FOR EACH FLOOR FOR FUTURE TENANT BUILDOUT, THE FIRE THE FIRE ALARM SHALL BE CAPABLE OF FUTURE EXPANSION AS REQUIRED IN THE TENANT TENANT SPACES. 3. ALL WIRING AND CONDUIT TO CONFORM TO N.F.P.A. 72 AND N.E.C. ARTICLE 760. WIRING SHALL BE SOLID COPPER OR STRANDED COPPER WITH A MAX. OF 7 STRANDS FOR 16 GA AND 18 GA, STRANDED COPPER WITH A MAX. OF 19 STRANDS FOR SIZES 14 AND LARGER AS RQUIRED BY N.E.C. 760 AND N.F.P.A. 70. 4. ALL FIRE STOP PENETRATIONS SHALL BE MADE WITH APPROVED (NEC) METALLIC CONDUIT AND SHALL BE SEALED WITH A U.L. APPROVED FIRE STOP MATERIAL. (SEE FIRE STOP DETAIL) 5. ROUTING OF THE FIRE ALARM SYSTEM CONDUIT IS DIAGRAMMATIC ONLY, VERIFY EXACT LOCATIONS PRIOR TO STARTING WORK. 6. ALL FIRE ALARM VISUAL SIGNAL (STROBES) SHALL ACTIVATE UPON INITIATION OF THE GENERAL ALARM. 7. ALL FIRE ALARM VISUAL SIGNALS IN OPEN AREA SHALL HAVE A THREE PLUS TEMPORAL PATTERN. 8. ALL FIRE ALARM AUDIBLE SIGNALS SHALL HAVE A SOUND LEVEL OF AT LEAST 15 dba ABOVE THE AVERAGE ABMBIENT SOUND LEVEL. 9. MANUAL STATIONS SHALL BE INSTALLED AT 48" INCHES A.F.F. 10. MOUNT FIRE ALARM SYSTEM HORN /STROBES SUCH THAT THE ENTIRE LENS IS 80" A.F.F. OR 6" BELOW CEILING, WHICH EVER IS LOWER. 11. MOUNT FIRE ALARM SYSTEM STROBES SUCH THAT THE ENTIRE LENS IS 80" A.F.F. OR 6" BELOW CEILING, WHICH EVER IS LOWER. 12. SMOKE DETECTORS TO BE INSTALLED AS REQUIRED BY N.F.P.A. 72. 13. THE FIRE ALARM PANEL SHALL HAVE AN EARTH GROUND CONNECTION AS REQUIRED BY THE SYSTEM MANUFACTURER, AND N.E.C. ARTICLE 760. MINIMUM WIRE SIZE IS 8 AWG FOR GROUND CONNECTION. (NOTE PANEL NEUTRAL OR CONDUIT GROUND IS NOT ACCEPTABLE 14. A GENERAL ALARM SHALL BE ANNUNCIATED UPON ACTIVATION OF ANY PULL STATION, FLOW SWITCH OR DETECTION DEVICE. 15. A TROUBLE SIGNAL SHALL BE ANNUNCIATED UPON FAILURE OR REMOVAL OF ANY DETECTION OR MANUAL DEVICE. 16. A SUPERVISORY SIGNAL SHALL BE ANNUNCIATED UPON ACTIVATION OF ANY FIRE SPRINKLER SYSTEM TAMPER SWITCH. 17. HVAC DUCT SMOKE DETECTORS SHALL BE CONNECTED TO THE FIRE ALARM CONTROL PANEL AND SHALL INITIATE A SUPERVISORY SIGNAL ONLY. 18. FIRE ALARM SYSTEM SHALL BE U.L. CERTIFIED. 19. ALL FIRE ALARM INITIATING DEVICES SHALL BE ADDRESSABLE AND ALL FIRE ALARM CIRCUITS SHALL BE CLASS "B ", STYLE "4" SLC AND CLASS "B" STYLE "Y" NAC CIRCUITS. 20. PROVIDE CERTIFICATE OF COMPLETION AT THE FINAL INSPECTION OF THE FIRE ALARM SYSTEM. 21, PROVIDE THE OWNER WITH A COMPLETE FIRE ALARM SYSTEM AND INSTALLATION MANUAL COVERING MANUAL COVERING ALL SYSTEM EQUIPMENT INSTALLED FOR THIS PROJECT. KEEP AT THE MAIN FIRE ALARM CONTROL PANEL. 22. ALL PULL STATIONS TO HAVE UL LISTED COVERS. 23. ALL STROBE LIGHTS SHALL COMPLY WITH NFPA 72 24. MINIMUM RADIO SIGNAL STRENGTH AS REQ'D BY AHJ SHALL BE MAINTAINED PER FFPC NFPA 1 11.3.1.3. RADIO SIGNAL STRENGTH MUST BE THE SAME FOR INSIDE AND OUTSIDE OF THE BUILDING. PROVIDE AN AMPLIFIED SYSTEM TO MEET MINIMUM RADIO STRENGTH AS REQUIRED BY AHJ. FIRE ALARM RISER DIAGRAM, BATTERY CALCULATIONS, AND NOTES 0 Design Services For The B u i I t Environment ■ Atlanta Birrr)ingham Cincinnati Columbus Dallas Fort Lauderdale Knox ViIIe Jackson Jacksonvilie Louis ViIIe M e m p h i s N a s h v i I I e Richmond Tampa ■ G R, F S H A M M I T I~""I A N D P A R T N E R S 6030 Hollywood Blvd, Suite 210 Hollywood, Florida 33024 904.981.9100 FIRM'S FLORIDA CERT. NCB, AAP000034/CA3806 I€126000797i1_.C26000381 707 N.E. 3rd AVE., SUITE 200 FORT LAUDERDALE, FL. 33304 964) 527 -1112 Ek CA #00009181 PJT. MGR: WCHAEL H00 PROJECT #. 120717 w LLJ ,:` 1 .< r U_ O V) c� Z S , LD OnT_ LLJ 0 J 5 m U d- l� QI E ALARM f�A i�TROW C�AL"UL�A`T 0N 00 j%JIM1#1111 a --- -- --- --- - -...._._._-` ---- -- ----- --- -- 2 No. - pate - Revision 6 0p j °•. a :� 1 1 �� ITEM ------- --- DESCRIP11ON -- ^- --- .._.,_ ------- ._..._..- . -..., STANDBY -------- QTY - -- TOTAL - - ----- - - - - -- ALARM -_ -- QTY f TOTAL Q 03/29113 ;City Comments Response CURRENT STANDBY CURRENT j ALARM PER UNIT 10/04/13 VE Revisions CURRENT PER UNIT CURRENT 10/04/13 I.T. Revisions (AMPS) PER ITEM (AMPS) (AMPS) ------------ ---------- - - - - -- - ------- (AMPS) Elp - MANUAL PULL STATION ---- ---------------- - - -- - - - -- ------------ - - - -- .0 X 11 = , _ .0� 000230 X 11 = .00253 �Iwp ----- ---------- PHOTOELECTRIC SMOKE DETECTOR - - - -- - - - 000230 - -- X 8 = .00184 0065 X 8 _ 052 -OE ELEVATOR PHOTOELECTRIC SMOKE DETECTOR .000230 - - -- --- -- X 13 = - - - - -_ - - - -- 00299 _._ _ 0065 -- X - 13 = 0845 2 D0 - DUCT DETECTOR - - - -- .015 X 2 = .03 .012 X 2 = - .024 1 R/F HEAT DETECTOR 00015 - X 3 = 00045 A05 X 3 = 015 FACp FIRE ALARM CONTROL PANEL .1 X 1 = -- - -- 1 15 X 1 ___ -- i .15 --- _.____._ ------ ------------- ----- ----- RAP FIRE ALARM SYSTEM POINT ANNUNCIATOR .04 X 1 - j .04 .056 X 1 - .056 FAANS ALARM COMMUNICATIONS ANNUNCIATOR 1 -� - X 1 = - - - -- - - - -- 1 __._. _ 17 X 1 _ - - - - -- 1 .17 -- - -- - --- - - - - --- - -- Q 75 -------------------------------------- -- -- ----------- ----------- - ----------------------------- --------- STROBE (75 CANDELA) - - �- �� .0 T X 44 _ 0 .123 X 44 = -° °- 5.412 �0010 ` -------------- STROBE (110 CANDELA) --------------------------------------- ----------------- --------------------------------------------------- - - - - -- ----------- 0 ------- - - - - -- --- - - - - -' - ----------- ---------------------------- X - -- - 1 -------------- - - - - -- 0 .140 -------- _ X T 1 _ .140 - ------- TOTAL SYSTEM - - - - -- ---- - - - - -- -- ------------------------------- 0.3 - - - - -- TOTAL SYSTEM ;-------- ---- - - - - -- ! 6.1 STANDBY CURRENT (AMPS) ALARM CURRENT (AMPS) REQUIRED OPERATING TIME OF SECONDARY POWER SOURCE FROM NFPA 72 1- 5.2.5: STANDBY: 24 HOURS ALARM: 5 MINUTES X 1/60 = 0.0833 HOURS REQUIRED TOTAL SYSTEM REQUIRED REQUIRED TOTAL SYSTEM REQUIRED STANDBY STANDBY STANDBY ALARM ALARM ALARM TIME CURRENT CAPACITY TIME CURRENT CAPACITY (HOURS) (AMPS) (AMP - HOURS) (HOURS) (AMPS) (AMP- HOURS) 24 X L 0.3 = 7.2 (� 0.0833 X 6.1 0.5081 REQUIRED REQUIRED REQUIRED DERATING MINIMUM STANDBY ALARM AMPERE HOUR', FACTOR 0 AMP -HOUR CAPACITY CAPACITY BATTERY 1.2 BATTERY (AMP- HOURS) (AMP- HOURS) REQUIRED --------------------------------------- - - - - - - - - - - - -- 7.2 + 0.5081 - - - -- --------------- - - - - -- 7.7081 X - - - - - -- - -- 1.2 - - -- - = 9.2497 FIRE ALARM RISER DIAGRAM, BATTERY CALCULATIONS, AND NOTES 0 Design Services For The B u i I t Environment ■ Atlanta Birrr)ingham Cincinnati Columbus Dallas Fort Lauderdale Knox ViIIe Jackson Jacksonvilie Louis ViIIe M e m p h i s N a s h v i I I e Richmond Tampa ■ G R, F S H A M M I T I~""I A N D P A R T N E R S 6030 Hollywood Blvd, Suite 210 Hollywood, Florida 33024 904.981.9100 FIRM'S FLORIDA CERT. NCB, AAP000034/CA3806 I€126000797i1_.C26000381 707 N.E. 3rd AVE., SUITE 200 FORT LAUDERDALE, FL. 33304 964) 527 -1112 Ek CA #00009181 PJT. MGR: WCHAEL H00 PROJECT #. 120717 w LLJ ,:` 1 .< r U_ O V) c� Z S , LD OnT_ LLJ 0 J 5 m U d- c`� N REVISION 00 j%JIM1#1111 a 2 No. - pate - Revision 6 0p j °•. a :� 1 1 �� � aF �1 m• C? ry a• cam.. 3 C Idcmw 1U0 .......... ......:............................_................._._.... .........._.................... 2 03/15/13 City Comments Response U FIRE ALARM RISER DIAGRAM AND BATTERY CALCULATIONS FA3ml SCALE: N.T.S. F I L E: PROJECT: 253080.00 DATE: 1 1 /29/201 2 9Ig4101� "I REVISION N IT a 2 No. - pate - Revision o 02/01/13 Addendum #1 rY .......... ......:............................_................._._.... .........._.................... 2 03/15/13 City Comments Response U Q 03/29113 ;City Comments Response .......... = ------------------------------------------------------ a 04/22/13 City Comments Response 4 - -------------- - - -- - - -- - - ---- - - - --- -- - - - - -- - - - - --- j 5 ° 05/17/13 City Comments Response 10/04/13 VE Revisions aA 10/04/13 I.T. Revisions FIRE ALARM RISER DIAGRAM AND BATTERY CALCULATIONS FA3ml SCALE: N.T.S. F I L E: PROJECT: 253080.00 DATE: 1 1 /29/201 2