13-96R (2)-0334" FIRE RISER W/ SUPERVISED CONT
VALVE, FLOW SWITCH AND DRAIN LIN
ROUTE 4" FIRE •LINE ABOVE FLOOR
TO RISER. COORDINATE RISER
EXACT LOCATION WITH MECHANICAL
DUCTS TO AVOID CONFLICTS.
4" FIRE LINE UP TO ABOVE
GRADE AND THEN PENETRATE
BUILDING WALL.
4" FIRE LINE TO DDCV
& FDC. REFER TO CIVIL
ENGINEER DRAWINGS
FOR CONTINUATION.�,J
------------------------------------------- i
_r.
w
_________ �.� _ . - ..
-
ua
LF p�3 � - - -- - - - - -'- - -' -- -- - - -- - ----, .. ..... .... ------ - --
i
I li I i li i i ii ii
ry 1 1 1 1 1 1
WS
I �l�r' Il'rf r;;il� f f i Ih , . I1 • � , � , . � � „ , , , , � , f -I � � E
KEY NOTES
O 4" STANDPIPE AND 2" DRAIN RISER UP.
�2 SUPERVISED FLOOR CONTROL VALVE, SEE DETAIL ON SHEET FP1.1,
U3 2 -1/2" HOSE CONNECTION.
CONNECT NEW 2" DRAIN LINE TO STORM DRAIN LINE. PROVIDE S.O.V.
AND CHECK VALVE. SEE SHEET P2.2 FOR CONTINUATION.
O 4" STANDPIPE UP.
O SIDEWALL SPRINKLER AT ELEVATOR HOISTWAY NOT MORE THAN 2 FT
ABOVE THE FLOOR OF THE PIT.
O 1 -1/2" FIRE SPRINKLER LINE TO LANDSCAPE EQUIPMENT ROOM. PROVIDE
FIRE SPRINKLERS AS REQUIRED PER NFPA 13 (ORDINARY HAZARD).
PROVIDE SPRINKLER GUARDS.
Q FIRE SPRINKLER LINE ABOVE CEILING (TYPICAL)
Q GALVANIZED EXPOSED FIRE SPRINKLER LINE (TYPICAL).
FIRST FLOOR PLAN - NEW CONSTRUCTION FIRE SPRINKLER
SCALE: 1/$" = V -0"
2" DRAIN
0
COJ
m
Q
T
N
00
O
PLC s
10 RECESSED PENDENT SPRINKLERS INSTALLED ON RETURN BENDS (TYPICAL)PER
NFPA 13 SECT. 7.3.2.5(3).
>> PREACTON SYSTEM BRANCH LINES SHALL BE PITCHED AT LEAST 1/2" PER 10
FT. AND MAINS SHALL BE PITCHED AT LEAST 1/4" PER 10 FT. TO DRAIN PER
NFPA 13 SECT. 8.16.2.3.2.
12 DOUBLE INTERLOCK PREACTION SYSTEM VALVE CABINET VICTAULIC SERIES 745
FIRELOCK FIRE —PAC PART #SP0207457AB1B11 WITH PNEUMATIC /ELECTRICAL
RELEASE. SIZE: 2 ". ELECTRICAL CONTRACTOR SHALL CONNECT TAMPER & FLOW
SWITCHES TO FIRE ALARM PANEL AND SMOKE /HEAT DETECTORS TO PREACTION
SYSTEM CABINET ELECTRIC RELEASE PANEL.
13 DRAIN LINE TO DISCHARGE OVER FUNNEL TYPE FLOOR DRAIN. PROVIDE 2" AIR
GAP. REFER TO PLUMBING DRAWINGS FOR MORE INFORMATION.
14 PREACTION SYSTEM SHALL BE PROVIDED WITH INTERNALLY GALVANIZED STEEL
PIPE. NONGALVANIZED FITTINGS SHALL BE PERMITTED.
15 CONTRACTOR SHALL COORDINATE THE EXACT LOCATION OF THE RADIATION
SHIELDING PENETRATION WITH THE EQUIPMENT VENDOR /ARCHITECT PRIOR TO
INSTALLATION.
1s SECTIONAL VALVE ABOVE CEILING.
C
0
U
V
1
N
Design Services
For The B u i I t
Environment
0
Atlanta Birmingham
C i nc €nnati
CoIumbus D a I I a s
Fort Lauderdale
KnOXV'ille Jackson
Jacksonville Louisvilsw
Memphis Nashvil
Hic,hmQnd Tampa
0
R E S H A. M
M 1 T H A N D
PA R,T N E R S
6030 Hollywood Blvd.
Suite 210
Hollywood, Florida 33024
954„981.9100
FIRM'S FLORIDA
CERT. NO.
AAP000034/CA3806
IB26000797/LC 00'00381
707 N.E. 3rd AVE., SUM 200
FORT LAUDERDALE, FL. 33304
954) 527 -1112
CA #00009181
PJT. MGR: MICHAEL. H00
PROJECT #: 120717
Lij
0.
� w
0
LO
LIJ a
��1�g39339i�Ldv�
FiOR 3AN7UAN,- F' E. .
RIDA UC.&NB �#46t00
°ATE `A L 4 /L4,
FIRST FLOOR PLAN
NEW CONSTRUCTION
FIRE SPRINKLER PLAN
FP2ml
FILE:
PROJECT: 29080.00
DATE: 1 1/2912012
REVISION
No. -
Date - Revision
02/01/13 ;Addendum #1
. ..............
2
........... ........................
................... i--................................
............. ....... ___________________ __.._.
03/15/13 i City Comments Response
......- ..---------- .......................................................
.........................................................
FIRST FLOOR PLAN
NEW CONSTRUCTION
FIRE SPRINKLER PLAN
FP2ml
FILE:
PROJECT: 29080.00
DATE: 1 1/2912012