Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
13-96 (3)-052
F> ; STAIR �___A 1 C�J N PL 1] A i I TT r60 107 2-T, F T I -- rivAi_r_- I ;-------- - - - - -- --------- - - - - -i ch - lI _ 5 AjL�Ef G^O EIS ' �xAI B ]NG T- - -- - -- ---- ----- )4 SF) --I A1TIN0 3 "S'-\ 102 ❑ 2- WAY lLl� SF) 1 1/4- D CONTROL r i lull// EXAM -- ---- - - - - -- - -- - -- - - - -- - - - -- -- -- -- - - - - - -- -- ; - - -- ---- - - - - -- ! y_�O - -1]7 --- - - - - -- LAB 11� �I n 9 1� o "cn /o 4 nn CEA I 1 /4 "CD 4 %'AGI NG I 8 -EMALE CO NEB i AMN - .113 � TOILET/ ANG1NG 4-SD 675 SF) FIRST FLOOR PLAN - NEW CONSTRUCTION SANITARY PLAN SCALE: 1/8" = V -0" 2 WAY 4 /I\ --------------Q--- 0 DRAWING KEYED NOTES: O 4" SANITARY LINE BELOW GRADE. 24 "X24 "X24" ELEVATOR SUMP PIT. 11 ELECTRIC ELEVATOR, (NO HYDRAULIC 16 NOTE: PROVIDE IMPACT PROTECTION FOR REFER TO CIVIL ENGINEER SEE ARCHITECTURAL DWG's FOR DETAILS OIL IS IN USE). SEE ARCHITECTURAL VERTICAL PLUMBING PIPES. SEE ARCHIT. DRAWINGS FOR CONTINUATION. THIS PIT IS ONLY FOR ANY RAINWATER DWG'S FOR DETAILS DRAWINGS FOR DETAILS O2 10" STORM DRAIN LINE BELOW GRADE. LIQUID OR SIMILAR 12 2 "ELEVATOR DRAIN LINE TO DISCHARGE 17 8" OVERFLOW ROOF DRAIN PIPE. REFER TO CIVIL ENGINEER ® ELEVATOR SUMP PUMP LIBERTY PUMPS INDIRECTLY TO SANITARY SYSTEM. TERMINATE 6" ABOVE FINISHED FLOOR. DRAWINGS FOR CONTINUATION. MODEL #ELV250 AUTOMATIC SUMERSIBLE SUMP PUMP (30 GPM. 14FT. TDH., 1/3 6 1 g O 6" OVERFLOW ROOF DRAIN PIPE DOWN. O3 10 " STORM DRAIN LINE BELOW GRADE. HP, 3450 RPM, 115 V) 13 3 /4-CD LINE IN CEILING SPACE. FIELD TERMINATE 6" ABOVE FINISHED FLOOR. REFER TO CIVIL ENGINEER DRAWINGS FOR CONTINUATION. O9 " 3/4 WATER HEATER RELIEF LINE COORD. 1 g 0 2 "SAN. STUB OUT FOR SINK INSIDE VAULT. (BY VARIAN). REFER TO VENDOR DRAWINGS ® TO BUILDING EXTERIOR TERMINATED FACE DOWN 6 14 BACK WATER VALVE IN ACCESS BOX FOR EXACT LOCATION. REFER TO CIVIL ENGINEER 10 FORMER TRENCH FORMER SYSTEM 15 O 2" DRAIN LINE FROM FIRE SPRINKLER 0 © TERMINATE 2" ELEVATOR DRAIN LINE WITH Zi DRAWINGS FOR CONTINUATION. (MO (MODEL TFX -12) CONSISTING OF RISER (PIPE DN.). SEE SHEET FP2.1 GOOSENECK OVER 4" HUB DRAIN. PROVIDE Q 4 "SANITARY STACK FROM ABOVE. PRE — ENGINEERED EPS FOAM FORMERS. FOR CONI1NUAl10N a AIR GAP AS REQUIRED PER FBC —P. © 4 "VENT PIPE UP. HEAVY DUTY DUCTILE IRON GRATE (UNCOATED) WITH APPROPRIATE LOCKING DEVICES (# 1811A) OR EQUAL 0 CD a� o! U c� N ai US c............ & � P ......... ......... ............ ............ ....... O Design Services For The BLI%It. Environment. N Atlanta Birmingham Cincinnati CoI urn bus D a I I a s Fart Lauderdale Knoxville Jackson Jacksonville Louisville Memphis Nashville Ri.chrnond Tarnpa 0 G R E S H A M IS M I T A N D 6030 Hollyw6od Blvd, Suite 2' 10 Hollywood, Florida 33024 954.981.9100 FIRM'S FLORIDA CERT NO, AAP000034/GA3800 IB26000797/LC2 :6000381 DELTA G CONSULTING ENGINEERS, INC. 707 N.E. 3rd AVE., SUITE 200 FORT LAUDERDALE, FL. 33304 (964) 627 -1112 CA #00009181 PJT. MGR: 1QCHAEL H00 PROJECT #: 120717 t8 CK 0 p L 0.. 0 ���r1q��6�35�d1 Arai d } y� o 00 f 1' rr ORG SAN u* PIRA /0 Ii! REVISION No. _ Date Revision 02/01/13 /Addendum #1 Q 03/15/13 City Comments Response 05/17/13 City Comments Response - - -- '' -------------- s v- 10/04/13 E Revisions -------------- - - - - -- - - - -- FIRST FLOOR PLAN NEW CONSTRUCTION SANITARY PLAN P2.2 FILE: PROJECT: 29080.00 DATE: 11/29/2012