13-96 (3)-050/6 /6\ 9 �I PLUMBING GENERAL NOTES Pl.l 1. ALL WORKMANSHIP AND MATERIAL SHALL BE IN STRICT ACCORDANCE WITH APPLICABLE LOCAL CODES, RULES AND ORDINANCES (FBC- 2010). 2. CONTRACTOR SHALL VISIT THE JOB SITE AND THOROUGHLY FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS. 3. ALL MATERIAL SHALL BE NEW. 4. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIVE. 5. ALL EXCAVATION AND BACKFILL AS REQUIRED FOR THIS PHASE OF CONSTRUCTION SHALL BE A PART OF THIS CONTRACT. 6. REQUIRED INSURANCE SHALL BE PROVIDED BY THE CONTRACTOR FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF WORK. 7. CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, INSPECTION AND TESTS. & DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE FOR THE EXACT LOCATION OF FIXTURES, PIPING, EQUIPMENT, ETC. 9. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. REPORT ANY DISCREPANCY TO ENGINEER /ARCHITECT PRIOR TO BEGINING CONSTRUCTION. 10. WATER PIPING SHALL BE TYPE "L" COPPER FOR 2" AND UNDER AND TYPE "K" COPPER FOR 2 -1/2" AND ABOVE. ALL UNDERGROUND WATER PIPING SHALL BE TYPE "K" COPPER. TYPE "M" IN CONCEALED SPACES IS ACCEPTABLE. 11. SOIL, WASTE AND VENT PIPING SHALL BE CAST IRON NO HUB 301 -72 ABOVE GRADE. BELOW GRADE USE SCHEDULE 40 PVC D.W.V. CONDENSATE DRAIN LINE USE SCHEDULE 40 PVC D.W.V. PVC SHALL NOT BE USED IN ANY MECHANICAL ROOMS OR IN ANY RETURN AIR PLENUMS . USE COPPER PIPE. 12. INSULATE ALL HOT WATER, HOT WATER RETURN, CONDENSATE LINES, EXHAUST LINES ABOVE GRADE AND FIRST 8' -0" OF COLD WATER LINE FROM WATER HEATER /BOILER AS FOLLOWS: HW SUPPLY AND RETURN - 1" THICK PREFORMED FIBERGLASS PIPE INSULATION W/ FACTORY JACKET. CONDENSATE PIPING - %- ARMAFLEX PREFORMED. EXHAUST PIPE - 3" THICK CALCIUM SILICATE BLOCK INSULATION W/1200 F. STEVENS CLASS CLOTH WRAP. 13. ISOLATE COPPER PIPE FROM HANGER OR SUPPORTS WITH ISOLATOR PAD (HAIR FELT LINING). 14. DIELECTRIC COUPLINGS ARE REQUIRED BETWEEN ALL DISSIMILAR METAL IN PIPING AND EQUIPMENT CONNECTIONS. 15. ALL FIRE RATED FLOOR AND WALL PENETRATIONS SHALL BE PROPERLY PROTECTED FROM FIRE, SMOKE AND WATER PENETRATION BY FILLING VOIDS BETWEEN PIPE AND WALL /FLOOR SLEEVES WITH FIRE RATED FOAM, CHASE TECHNOLOGY CORP.- CTC PR -855 OR 3M, CP -25 CAULKING OR 303 PUTTY, TO ACHIEVE SAME RATING AS WALLS OR FLOORS. 16. PROVIDE ACCESS PANELS FOR ALL CONCEALED VALVES. ACCESS PANELS IN RATED WALLS MUST MAINTAIN THE SAME RATING AND MUST MATCH THE FINISH OF THE WALL IN WHICH IT IS INSTALLED. PROVIDE STAINLESS STEEL COMBINATION COVER PLATE AND CL.EANOUT PLUG OR ACCESS PANEL FOR ALL WALL CLEANOUTS. 17. FURNISH AND INSTALL APPROVED P.D.I. SHOCK ARRESTORS ON MAIN LINES. REFER TO SCHEDULE IN THIS SHEET. 111 ALL AUTOMATIC ELECTRIC WATER HEATERS SHALL MEET THE STANDARDS OF THE LATEST ENERGY EFFICIENCY CODE. 19. ALL INSTALLATIONS SHALL MEET THE STANDARDS OF THE LOCAL AUTHORITY AND HEALTH DEPARTMENT. 20. OFF SET VENT PIPES 10' -0" AWAY FROM ANY FRESH AIR INTAKE OR DOOR OPENING 21. PROVIDE 1/2' TRAP PRIMER LINE FOR ALL FLOOR DRAINS FROM THE NEAREST PLUMBING FIXTURE OR USE AUTOMATIC TRAP PRIMER AS PPP P1 -500 WITH INTEGRAL BACKFLOW PREVENTER AND VACUUM BREAKER. 2 P1.1 PLUMBING SYMBOL LEGEND MARK SYMBOL DESCRIPTION COLD WATER SANITARY LINE - - - - - VENT LINE -- 1- --aw- SAFEWASTE LINE - COLD WATER LINE -- ------ HOT WATER LINE - - - HWR HOT WATER RETURN SD STORM DRAIN LINE CD CONDENSATE LINE SEAT & COVER ULTRA LOW CONSUMPTION FORCE MAIN LINE -- - DN PIPE DOWN -- --o UP PIPE UP ---Do-- GATE VALVE SEE PLANS FLOOR PENETRATION ADA WATER CLOSET FLUSH VALVE WATER HAMMER ARRESTOR RD ROOF DRAIN �} OD OVERFLOW ROOF DRAIN GD GARAGE DRAIN ® AD AREA DRAIN CO CLEAN OUT AIL VTR VENT THRU ROOF RWL RAIN WATER LEADER DO FD FLOOR DRAIN HB HOSE BIBB W/ SHUT -OFF VALVE AND VACUUM BREAKER SK ZURN 1343 OR EQUAL 1 1/2 WALL HYDRANT W SHUT -OFF 1/2 » VALVE AND VACU M BREAKER KOHLER ELECTRONIC FAUCET MODEL K -13474 ZURN MODEL Z1350 (ENCASED) COUNTER TOP SINK OR EQUAL WL XX RAIN WATER LEADER RISER CW XX COLD WATER RISER NO NORMALLY OPEN NC NORMALLY CLOSED U/G UNDER GROUND 7 P1.1 FIXTURE CONNECTION SCHEDULE MARK DESCRIPTION WASTE COLD WATER HOT WATER MANUFACTURE AND MODEL ACCESSORIES W WATER CLOSET TANK TYPE (FLOOR MOUNTED) 4" 1/2- __ MIRABELLE GALATIA COL. ONE -PIECE TOILET MODEL #MIRGA241 WH, WASHDOWN BOWL W/ INCLUDES POLISHED CROME FLUSH ACTUATOR. PROVIDE TRAP PRIMER RD ROOF DRAIN SEE ROOF PLAN - - -- SEAT & COVER ULTRA LOW CONSUMPTION GD GARAGE DRAIN SEE PLANS - - -- ZURN MODEL Z505 OR EQUAL. P2.3 SECOND FLOOR PLAN NEW CONSTRUCTION PLUMBING PLAN. DUAL FLUSH (0.8/1.2 GP SEE PLANS W ®1 ADA WATER CLOSET FLUSH VALVE 4 » 1 ___ TOTO MODEL CT705ELN(G), ELONGATED SLOAN "ROYAL OPTIMA" MODEL 111- 1.28HWS FLUSHOM. TRENCH DRAIN (FLOOR MOUNTED) - - -- ABT POLYDRAIN TRENCH DRAIN 8 FRONT BOWL (1.28 GPF) VALVE W/ EL -451 TRANSF., TOILET SEAT MODEL #SC534 L -1 ABOVE COUNTER LAVATORY (AT TOILET ROOMS) 1 1/4- 1/2- 1/2" TEAL CLEAR TEMPERED GLASS VESSEL BATH. SINK MODEL #420523 -L7 (0.5 GPM) KOHLER ELECTRONIC FAUCET MODEL # K -13474 SK ADA COUNTER TOP SINK (EXAM ROOM) 1 1/2 1/2 » 1/2 » KOHLER "VOX" ABOVE COUNTER BATH. SINK MODEL #K -2660 (0.5 GPM) KOHLER ELECTRONIC FAUCET MODEL K -13474 SK -1 COUNTER TOP SINK 1 1/2" 1/2" 1/2" KOHLER "UNDERTONE' SINGLE BOWL KOHLER "ELATE" KITCHEN SINK FAUCET LOUNGE ROOM & HOT LAB TO HEATER. ELECTRIC WATER HEATER 7IC DELETE IF PROVIDED S. STEEL SINK MODEL #K- 3335 -NA MODEL K- 13963 -CP (MAX. 1.8 GPM SK -2 COUNTER T& 1 1/2* 1/2* 1 /2" RMOUNTLAVATORY SINK PRO AIR GAP FITTING 3 ROOM BRACHY) HEATER SURFACE UNDE DE GUARDIAN G 848 EYEWASH (EEW)13474. J.SK JANITOR SINK 1 1/2 1/2- 1/2" ADVANCE TABCO MODEL #9 -OP -40 T &S FAUCET MODEL B- 0665 -BSTR D/W DISHWASHER 1 "I.W - -- 1/2- FIXTURE AS SPECIFIED BY ARCH / OWNER * DELETE IF PROVIDED EWC ADA ELECTRIC WATER COOLER 1 1/4- 1/2- - -- OASIS MODEL M8CREE 1/2- SUPPLY PIPES, MCGIURE ANGLE STOPS AND ADJUSTABLE "P" TRAP ". WM WASHING MACHINE 2" 1/2 1/2 SELECTED BY OWNER SELECTED BY OWNER BRACKETS REQ'D.) I I FOR AIR COMPLY MOUNT HEATER 1" SAFETY PAN DRAIN LINE NOTES: 1. ALL FIXTURE AND FAUCETS SHALL COMPLY WITH MIAMI WATER CONSERVATION REGULATIONS SECTION 8 -31, TABLE 604.4 2. ALL WALL HUNG PLUMBING FIXTURES SHALL COMPLY WITH F.B.0 -2010 SECTION 2318.1.15 & 2517.5.1.1 3. INSULATE PER A.D.A. ALL EXPOSED HANDICAP LAVATORIES DRAIN PIPING AND HOT & COLD STOP AND SUPPLIES. COVERS SHALL BE SOFT, REMOVABLE AND UPC APPROVED. MANUFACTURE: PLUMBEREX HANDY- SHIELD OR PRO- SERIES. 8 MIXING VALVE DETAIL P1.1 NO SCALE I TEMPERED WATER LINE (TEMP NOT TO EXCEED 1101 �-- MIXING VALVE LEONARD MODEL TM -30 OR EQUAL 3/41NLET/3/4 "OUTLET COLD WATER SUPPLY UNE HOT WATER SUPPLY LINE 3 Pl.l DRAIN SCHEDULE No DESCRIPTION DRAIN CW REMARKS FD FLOOR DRAIN 3" 1/2" ZURN MODEL Z415B OR EQUAL 3to6 (TOILET ROOMS) 1/8 B PROVIDE TRAP PRIMER RD ROOF DRAIN SEE ROOF PLAN - - -- ZURN MODEL Z100 OR EQUAL. GD GARAGE DRAIN SEE PLANS - - -- ZURN MODEL Z505 OR EQUAL. P2.3 SECOND FLOOR PLAN NEW CONSTRUCTION PLUMBING PLAN. TRENCH DRAIN SEE PLANS - - -- ABT TRENCH FORMER SYSTEM TD FIRST FLOOR (2.1 GALLONS) HEAT TRAP MODEL TFX -12 OR EQUAL TRENCH DRAIN SEE PLANS - - -- ABT POLYDRAIN TRENCH DRAIN 8 P2.6 FOURTH FLOOR PLAN NEW CONSTRUCTION SANITARY PLAN. THIRD FLOOR WATTS SERIES PLT -5 SYSTEM MODEL 2512F OR EQUAL AD AREA DRAIN 3" - - -- ZURN MODEL FD- 2322 -ST P3.1 DOMESTIC WATER PIPING ISOMETRIC HOT WATER TO - HEAT TRAP* 'I` OR EQUAL APPROVED. PD PLANTER DRAIN 3" - -- ZURN MODEL Z415B OR EQUAL P3.3 STORM DRAINAGE PIPING ISOMETRIC WATER SUPPLY P & T RELIEF VALVE (ONLY POTTED PLANTS TO BE TO HEATER. ELECTRIC WATER HEATER 7IC DELETE IF PROVIDED 1 USED AT PLANTER.) 4 P1.1 SLOPE OF HORIZ. DRAINAGE PIPE Q SIZE (inches) P.D.I. DESIGNATION MINIMUM SLOPE (inch per foot) FIXTURE UNITS 2-1/2 or less CONNECTION 1/4 SIOUX CHIEF 652 -A 3to6 1/8 B 8 or larger 12 -32 1/16 TABLE 704.1 OF THE FLORIDA PLUMBING CODE 2010 5 P1.1 WATER HAMMER ARRESTOR SCHEDULE Q P.D.I. DESIGNATION MANUF. & MODEL FIXTURE UNITS WATER SUPPLY CONNECTION A SIOUX CHIEF 652 -A 1 -11 1/2" B SIOUX CHIEF 653 -B 12 -32 FULL FLOW BALL VALVES AND 3/4" C SIOUX CHIEF 654 -C 33 -60 1" SIOUX CHIEF SHOCK ARRESTORS APPROVED FOR INSTALLATION WITH NO ACCESS DOOR REQUIRED. CONFORMS TO ANSI /ASSE 1010 STANDARDS. 6 TYPICAL CONDENSATE DRAIN TRAP P1 .1 SCALE: N.T.S. PITCH TOWAR CLEAN PERFORATED 18' Mil 2" MIN DRAIN PAN BE AT LEAST THE NIPPLE ON THE PLUMBING INDEX TYPICAL ELECTRICAL WATER HEATER DETAIL DRAWING Q NO SCALE 1 P1.1 PLUMBING INDEX, NOTES, SCHEDULES AND DETAILS WATER SUPPLY VACUUM RELIEF VALVE SHUT -OFF VALVE 2 P1.2 PLUMBING DETAILS PROVIDE WITH QUARTER TURN 1 1 A "TACO" MODEL # 11OB. 120V, 3 P2.1 FIRST FLOOR PLAN NEW CONSTRUCTION DOMESTIC WATER FULL FLOW BALL VALVES AND 60Hz. 10, 1/12 HP. 4 P2.2 FIRST FLOOR PLAN NEW CONSTRUCTION SANITARY PLAN. 5 P2.3 SECOND FLOOR PLAN NEW CONSTRUCTION PLUMBING PLAN. 7T/, WATTS SERIES PLT -5 6 P2.4 THIRD FLOOR PLAN NEW CONSTRUCTION PLUMBING PLAN. (2.1 GALLONS) HEAT TRAP 7 P2.5 FOURTH FLOOR PLAN NEW. CONSTRUCTION DOMESTIC WATER CHECK VALVE HOT WATER 8 P2.6 FOURTH FLOOR PLAN NEW CONSTRUCTION SANITARY PLAN. WATTS SERIES PLT -5 9 P2.7 ROOF LEVEL PLAN NEW CONSTRUCTION PLUMBING PLAN (2.1 GALLONS) BALL VALVE (TYP.) 10 P3.1 DOMESTIC WATER PIPING ISOMETRIC HOT WATER TO - HEAT TRAP* 'I` 11 P3.2 SANITARY PIPING ISOMETRIC SYSTEM. .--- 12 P3.3 STORM DRAINAGE PIPING ISOMETRIC WATER SUPPLY P & T RELIEF VALVE SHUT -OFF VALVE TO HEATER. ELECTRIC WATER HEATER 7IC DELETE IF PROVIDED P & T RELIEF VALVE. 3/4* P & T RELIEF LINE FULL SIZE 3/4!' RELIEF DRAIN UNE WITH THE WATER HEATER SHOP DRAWING REQUIREMENTS 1. SHOP DRAWINGS, SHALL BE SUBMITTED COMPLETE, TOGETHER AT ONE TIME AND MUST COME THROUGH THE ARCHITECT. ALL SUBMITTALS SHALL BE MADE WITHIN 30 DAYS OF NOTICE TO PROCEED. 2. ALL SUBMITTALS MUST CLEARLY INDICATE EXACTLY WHICH ITEMS ARE BEING PROPOSED FOR USE. IF NOT, THE SUBMITTAL SHALL BE REJECTED. 3. SUBSTITUTIONS SHALL BE LIMITED TO ONE OF THE ALTERNATES LISTED IN THE CONSTRUCTION DOCUMENTS. PRODUCTS CONSIDERED TO BE EQUAL SHALL BE REVIEWED AND ACCEPTED BY THE ENGINEER, ARCHITECT AND OWNER (10) DAYS PRIOR TO BID DATE. 4. THE CONTRACTOR ASSUMES ALL DESIGN RESPONSIBILITY AND ALL FINANCIAL RISKS FOR PROCEEDING PRIOR TO SHOP DRAWINGS PROCESSING, AND ON ANY ITEM OR WORK THAT IS AT VARIANCE TO THE CONSTRUCTION DOCUMENTS. 5. SHOP DRAWINGS AND SUBMITTALS FOR EACH ITEM SHALL BE REVIEWED NO MORE THAN TWICE. A THIRD SUBMITTAL ON AN ITEM MUST BE ACCOMPANIED BY A PURCHASE ORDER FROM THE CONTRACTOR OR IT SHALL BE REJECTED. 6. CIRCUMSTANCES NECESSITATING A REVISION TO THE PERMITTED DOCUMENTS NOT PROCESSED PRIOR TO INSTALLATION MAY NOT BE ACCEPTED. IF ACCEPTED IT MUST BE LEGIBLE, ACCURATE AND ACCOMPANIED BY A PURCHASE ORDER ORDER FROM THE CONTRACTOR. THE REVISION SHALL BE CHARGED TO' THE CONTRACTOR AND DELIVERED TO HIM ON A C.O.D. BASIS. 7. SUBSTITUTIONS FROM THE BASE DESIGN OR VARIATIONS TO THE PERMITTED CONTRACT DOCUMENTS, WHETHER RESULTING FROM PROCESSED SHOP DRAWINGS OR NOT, THAT RESULT IN REQUIREMENTS IN LETTERS OF AUTHORIZATION AND /OR PERMIT CONTRACT DOCUMENT CHANGES MANDATED BY THE AUTHORITY HAVING JURISDICTION WILL NOT BE MADE BY THIS OFFICE UNLESS ACCOMPANIED BY A PURCHASE ORDER FROM THE CONTRACTOR, AND RELEASED ON A C.O.D. BASIS. 8. CONTRACTOR SHALL SUBMIT 5 COPIES OF SHOP DRAWINGS. 9 TYPICAL ELECTRICAL WATER HEATER DETAIL P1.1 NO SCALE COLD WATER SUPPLY VACUUM RELIEF VALVE SHUT -OFF VALVE INUNE CIRCULATING PUMP TO BE 3/4 �� HW WATTS MODEL 36 -Mt PROVIDE WITH QUARTER TURN 1 1 A "TACO" MODEL # 11OB. 120V, 3/4" CW FINISHED CEILING FULL FLOW BALL VALVES AND 60Hz. 10, 1/12 HP. UNIONS (TYPICAL) THERMAL EXPANSION TANK 7T/, WATTS SERIES PLT -5 CHECK VALVE 1 (2.1 GALLONS) HEAT TRAP 1 THERMAL EXPANSION TANK O 3/4" HW CHECK VALVE HOT WATER WATTS SERIES PLT -5 SHUT -OFF VALVE (2.1 GALLONS) BALL VALVE (TYP.) LINE I HOT WATER TO - HEAT TRAP* 'I` HEAT HEAT TRAP (TYP.) - - UNION SYSTEM. .--- WATER SUPPLY P & T RELIEF VALVE SHUT -OFF VALVE TO HEATER. ELECTRIC WATER HEATER 7IC DELETE IF PROVIDED P & T RELIEF VALVE. 3/4* P & T RELIEF LINE FULL SIZE 3/4!' RELIEF DRAIN UNE WITH THE WATER HEATER TERMINATE OVER SERVICE SINK ELECTRIC WATER AIR GAP FITTING 3 DRAIN VALVE BY MAN UFACT. HEATER PROVIDE A HARD COPPER RELIEF VALVE, SET HEATER WITHIN 24" X 24" X 4" DRAIN VALVE DISCHARGE AT EXTERIOR BUILDING DEEP GALVANIZED SHEET METAL DRAIN i 6 "MIN. A.F.F PAN (24 GAGE MINIMUM) * DELETE IF PROVIDED 3/4" PLYWOOD BELOW I WITH THE WATER HEATER WATER HEATER DRAIN , I FLOOR WATER HEATER THERMOSTAT PAN AS PLATFORM SHALL BE SET AT 11O'F I 2 » x 2 x 1L8 " ANGLE IRON SIZE I I PROVIDE A 3 _/4"HARD COPPER RELIEF VALVE. IN. 2-M MOP SINK BRACKETS REQ'D.) I I FOR AIR COMPLY MOUNT HEATER 1" SAFETY PAN DRAIN LINE 53" A.F.F. TERMINATE OVER SERVICE SINK 1 *DRAIN LINE TERMINATED I 2 "MIN. ABOVE MOP SINK 2 1/2- ANCHOR BOLT OR I FOR AIR GAP COMPLY EXPANSION BOLT (2 PER BRACKET) WATER HEATER SCHEDULE WATER HEATER SCHEDULE I.D. MANUFACTURER MODEL GALS. VOLTAGE KW PHASE EFF REMARKS I.D. MANUFACTURER MODEL GALS VOLTAGE KW PHASE EFF REMARKS EYIH -1 LOCF#NVAR ETT05OKK 50 208 4.5 1 0.92 FIRST FLOOR EWH -2 LOCHINVAR ESM30KK 30 208 4.5 1 0.93 FOURTH FLOOR C 0 .N U M r ai Design Services For The Built. Environment ■ Atlanta l3irmingham Cinciin 'nat Cofer. bus Dallas Fort Lauderdale Jacksonville Louisville Memphis Nashville Richmond Tampa ■ R E S H A M SMITH AND P A. R T N E R. S 603.6 Hollywood Bled. Site 210 Hollywood, Florida 3302 954.981. 100 FIRM'S FI..ORID.A CERT. NCB', AAP000034TCA3006 IB26000797/LC26000351 Ao�DELTA G CONSULTING ENGINEERS, INC. 707 N.E. 3rd AVE.. SUITE 200 FORT LAUDERDALE, FL. 33304 (964) 627 -1112 cA #00009181 PJT. MGR: IQCHAEL H00 PROJECT #: 120717 LL,. L 0 JAS U �. S1v'f 1C�C 1�a >m OF 012 %1'31'1ov Igo. Date 02/01/13 4 03/15/13 A 03/29/13 Revisioln Addendum #1 City Comments Response City Comments Response I 10/04/13 i VE Revisions PLUMBING INDEX, NOTES, SCHEDULE AND DETAILS. P101 FILE: PROJECT: 29080.00 DATE: 1 1 /29/201 2