13-96-251"I u T C_ y_ T - ;, _i NT G c� � 1,7 - = » > >S J i' ,� E 3 (;l :f) V) C. :° "L) to V o w co (o fn c> J co _ _ - F. in 0 - r co co GENERAL• 1. THE DRAWINGS ARE INTENDED M SHOW THE GENERAL ARRANGEMENT. DESIGN AND EXTENT OF THE WORK AND ARE PARTIALLY DIAGRAMMATIC. THEY ARE NOT INTENDED TO BE SCALED FOR ROUGH-IN MEASUREMENTS, OR M SERVE AS 940P DRAWINGS OR POR70a THEREOF. 2. ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED M BE TYPICAL AND SHALL BE CONSTRUED M APPLY TO ANY SMILAR SITUATION ELSEWHERE ON THE PROJECT, EXCEPT WHERE A DIFFERENT DETAIL OR SECTION IS SHOWN. 3. PRIOR TO START OF CONSTRUCTION. THE CONTRACTOR AND ALL THE SUB- CONTRACTORS SHALL VERIFY ALL GRADES, LINES, LEVI -% DWENSIONS AND COORDINATE EXISTING CONDITIONS AT THE JOB STE WITH THE PLANS AND SPECIFICATIONS THEY SHALL REPORT ANY INCONSISTENCIES OR ERRORS N THE ABOVE TO THE ARCHTECT/ENOM BEFORE COMMENCING WWORK. THE CONTRACTOR AND HIS SUBCONTRACTORS SHALL LAY OUT THEIR WORK FROM ESTABLISHED REFERENCE PONDS AND BE RESPONSIBLE FOR ALL LINES, ELEVATIONS AND MEASUREMENTS N CONNECTION WITH THEIR WORK. 4. F ANY ERRORS OR OMIS %ONS APPEAR N THE DRAWINGS, GENERA. NOTES OR OTHER DOCUMENTS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER IN WRITING OF SUCH OMISSION OR ERROR PRIOR TO PROCEEDING WITH ANY WORK WHICH APPEARS IN QUESTION. IN THE EVENT OF THE CONTRACTOR'S FAILING M GIVE SUCH AN ADVANCED NOTICE, HE SHALL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY SUCH ERRORS OR OMISSIONS AND THE COST OF RECTIFYING THE SAME 5. THE CONTRACTOR SHALL USE THE STRUCTURAL DRAWINGS AND SPECFlCA71ONS TOGETHER WITH THE ARCHITECTURAL, MECHANICAL, ELECTRICAL AND OTHER TRADE DRAWINGS AND SHOP DRAWINGS, TO LOCATE DEPRESSED SLABS. SLOPES, DRAMS, OUTLETS, RECESSES. OPENINGS, BOLT SETTING. SLEEVES, DIMENSIONS, ETC. NOTIFY ARCHTECT/ENGINEER. IN WRITING, OF ANY POTENTIAL CONFUC13 BEFORE PROCEEDING WITH THE WORK. 5. THIS PROJECT INCLUDES SEVERAL STRUCTURAL ELEMENTS M BE DESIGNED BY THE CONTRACTOR'S OR SUPPLIER'S DELEGATED STRUCTURAL ENGINEER. NOTE THAT ANY INFORMATION (SUCH AS SIZE, DIMENSIONS, REINFORCEMENT, INTERNAL AND EXTERNAL CONNECTIONS, ETC.) PROVIDED N THESE DRAWINGS ARE ONLY FOR GUIDANCE AND CLOSER COST ESTIMATING (UNLESS INDICATED M BE USED AS MINIMUM REQUIREMENTS). THE DELEGATED ENGINEER(S) SHALL DETERMINE THE FINAL STRUCTURAL REQUIREMENTS, BASED ON HIS/HER CALCULATIONS. INFORM A/E OF ANY CHANGES, SO THEY CAN BE INCORPORATED IN THE A/E'S RECORD PLANS AND DETAILS (AD BE RESUBMITTED FOR BUILDING DEPARTMENT REVIEW. IF SO REQUIRED). THE CONTRACTOR AND HIS SIBS SHALL CONSTRUCT THE ELEMENTS BASED ONLY ON THE FULL DESIGN PLANS AND DETAILS (SHOP DRAWINGS) ISSIIED BY THE DELEGATED ENGNEER'S), REVIEWED BY THE A/E OF RECORD AND APPROVED BY THE REGULATING BUILDING DEPARTMENT. ANY PRICING OF THE DELEGATED ENGINEERED ELEMENTS OFF ANY OTHER PLANS, SHALL BE CONSIDERED PRELIMINARY OR FOR GENERAL BUDGET PRICING ONLY. SHOP DRAWINGS REVIEW: 1. ALL SHOP DRAWINGS SHALL BE SUBMITTED FOR ENGINEER'S REVIEW ONLY AFTER THEY HAVE BEEN THOROUGHLY REVIEWED BY THE CONTRACTOR FOR CONSTRUCTION METHODS, DIMENSIONS, FIELD CONDITIONS, -AS- CONSTRUCTED' DIMENSIONS AND OTHER TRADE REQUIREMENTS, AND STAMPED WITH THE CONTRACTOR'S APPROVAL STAMP. 1 THE SHOP DRAWING REVIEW BY THE A/E OF RECORD IS ONLY FOR GENERAL CONFORMANCE WITH THE DESIGN CONCEPT AND INFORMATION GIVEN IN THE CONSTRUCTION DOCUMENTS. CORRECTIONS OR COMMENTS MADE ON THE SHOP DRAWINGS DURING THE A/E REVIEW DO NOT RELIEVE THE CONTRACTOR FROM COMPLIANCE WITH THE REQUIREMENTS OF THE PLANS AND SPECFICATOM REVIEW OF A SPECIFIC ITEM SHALL NOT INCLUDE REVIEW OF AN ASSEMBLY OF WHICH THE ITEM IS A COMPONENT. THE CONTRACTOR IS RESPONSIBLE FOR DIMENSIONS TO BE CONFIRMED AND CORRELATED AT THE J OBSTE; INFORMATION THAT PERTAINS SOLELY TO THE FABRICATION PROCESSES OR TO THE MEANS, METHODS TECHNIQUES. SEQUENCES AND PROCEDURES OF CONSTRUCTION; COORDINATION OF THE WORK WITH THAT OF ALL OTHER TRADES AND PERFORMING ALL WORK IN A SAFE AND SATISFACTORY MANNER & THE ENGINEER ASSUMES NO RESPONSIBILITY FOR DIMENSIONS, QUANTITIES, ENGINEERING DESIGN PREPARED BY DELEGATED ENGINEERS. ERRORS OR OMISSIONS AS A RESULT OF REVIEWING ANY SHOP DRAWINGS ANY ERRORS OR OMISSIONS MUST BE MADE GOOD BY THE CONTRACTOR, RRESPECTIVE OF RECEIPT. CHECKING OR REVIEW OF DRAWINGS; BY THE ENGINEER AND EVEN THOUGH WORK IS DONE N ACCORDANCE WITH SUCH DRAWINGS 4. BEFORE STRUCTURAL INSPECTIONS CAN BE MADE ON A PORTION OF THE STRUCTURE, ALL RELATED SHOP DRAWINGS. DELEGATED ENGINEERING, PRODUCT APPROVAL, MANUFACTURER'S DATA AND OTHER RELATED INFORMATION, MUST BE REVIEWED AND ACCEPTED BY THE ENGINEER -OF- RECORD AND APPROVED BY THE BUILDING DEPARTMENT. 5. ALL SHOP DRAWINGS SHALL CONTAIN THE MINIMUM INFORMATION, OUTLINED IN THE LOCAL BUILDING CODE 6. UNLESS OTHERWISE AGREED UPON. ALL SHOP DRAWINGS SHALL BE SUBMITTED THRU THE ARCHITECT. THE ENGINEER WILL RETURN REVIEWED SHOP DRAWINGS TO THE ARCHITECT. 7. ANY COMMENTS, QUESTIONS AND MODIFICATIONS MADE BY THE SHOP DRAWING DETAILER, TO THE A/E'S DESIGN AND /OR DETAILING, SHALL BE CLEARLY MARKED (CLOUDED OR FLAGGED). 8. CONTRACTOR AND HIS DETAILER SHALL MAKE SURE THAT ALL THE FOGGED ITEMS ON THE %HOP DRAWINGS HAVE BEEN RESPONDED M BY THE A/E. ITEMS THAT INADVERTENTLY HAVE NOT BEEN RESPONDED M BY THE A/E SHALL NHU BE CONSDERED AS A YES OR NO ANSWER. THE CONTRACTOR OR HIS DETAILEIR SHALL COMMUNICATE DIRECTLY WITH THE A/E TO DISCUSS ALL THE UNANSWERED OR STILL OUESTIONABLE ITEMS 9. IF THE CONTRACTOR OR HIS DETAILER ARE NOT IN AGREEMENT OR SATISFIED WITH THE A/E RESPOND TO THEIR QUESTIONS ON THE SHOP DRAWINGS, THEY ARE ENCOURAGED TO CALL THE A/E TO DISCUSS THE ISSUES AND CLARIFY THEM FURTHER 10. NO FABRICATION OR CONSTRUCTION SHALL BEGIN UNTIL ALL THE OUTSTANDING ITEMS ON THE SHOP DRAWINGS HAVE BEEN CLARIFIED AND AGREED UPON. 10. DELEGATED ENGINEERED SHOP DRAWINGS N THE STATE OF FLORIDA, SEE SECTIONS OF 'DELEGATED ENGINEERING RESPONSIBUTY AND DEFINITIONS FOR SPECIFIC STRUCTURAL ELEMENTS /COMPONENTS DESIGNS, IN COMPLIANCE WITH CHAPTER 61G15. OF THE FLORIDA ADMINISTRATIVE CODE CONSTRUCTION MEANS AND METHODS 1. SHORFC BRACING AND RESHORFt AS REQUIRED BY PROJECT CONDITIONS AND THE LOCH. BUILDING CODE OR THE LOCAL BUILDING DEPARTMENT, CONTRACTOR TO PROVIDE SHOP DRAWINGS (INCLUDING ENGINEERING CALCULATIONS) FOR ALL SHORES, VERTICAL AND LATERAL BRACING AND RESHORES (AND REMOVAL OF SAME) TO BE USED FOR THIS CONSTRUCTION. THE ABOVE SHALL BE DESIGNED. SIGHED AND SEALED BY A PROFESSIONAL STRUCTURAL ENGINEER (FLORIDA REGISTERED) ENGAGED BY THE CONTRACTOR, AS A DELEGATED ENGINEER FOR THE ABOVE ELEMENTS. THE ENO; M -OF- RECORD WALL NOT DESIGN FORMWORK AND BRACING, NOR ASSUME RE%NMBIUTY FOR THE SHORES, BRACING AND STABILITY DURING CONSTRUCTION. CONTRACTOR TO SUBMIT THE SIGNED AND SEALED SHOP DRAWINGS M THE ENGINEER OF RECORD. AS REWIRED. M BE REVIEWED FOR GENERAL COMPLIANCE WITH THE STRUCTURAL DESIGN INTEND. F SO REQUIRED, CONTRACTOR TO SUBMIT A COPY OF THESE SIGNED AND SEALED DOCUMENTS, RENEWED BY THE ENGINEERR -OF- RECORD, TO THE LOCAL BUILDING DEPARTMENT. 1 THE CONTRACTOR IS RESPONSIBLE AND STALL COMPLY WITH THE SAFETY REOUIREMDO OF LOCAL BUILDING CODE AND ALL OTHER APPLICABLE LOCAL, STATE AND FEDERAL LAWS. 3. PROVIDE AND MAINTAIN CHARD LIGHTS AT ALL BARRICADES. RAILINGS, ABSTRACTIONS N THE STREETS, ROADS OR SIDEWALKS AND ALL TRENCHES OR PITS ADJACENT M PUBLIC WALKS OR ROADS. 4. AT ALL TIMES, PROVIDE PROTECTION AGAINST WEATHER (RAN, WIND, STORMS OR THE SUN). SO AS TO MAINTAIN ALL WORK, MATERIALS. APPARATUS AND FIXTURES FREE FROM INJURY OR DAMAGE PROVIDE ADEQUATE BRACING M THE ELEMENTS ALREADY IN PLACE (ESPECIALLY MASONRY WALLS) AGAINST WIND FORCES CAPABLE OF DAMAGING THIS WORK 5. AT THE END OF THE DAYS WORK, COVER ALL WORK LIKELY M BE DAMAGED. ANY WORK DAMAGED BY FAILURE M PROVIDE PROTECTION SHALL BE REMOVED AND REPLACED WITH NEW WORK AT THE CONTRACT'OR'S EXPENSE 6. THE CONTRACTOR SHALL PAY FOR ALL DAMAGES M ADJACENT STRUCTURES, SIDEWALKS AND TO STREETS OR OTHER PUBLIC PROPERTY OR PUBLIC UTILITIES. 7. -OSHA- SAFETY INSPECTIONS ARE W1 A PART OF OUR SERVICES. OUR PRESENCE ON SITE (FOR OBSERVATIONS, INSPECTIONS OF THE WORK IN PROGRESS OR MEETINGS) SMALL 01 CONSTRUED AS OUR ACTING AS 'OSHA' INSPECTORS. CONFORMING WITH ALL APPLICABLE 'OSHA' SAFETY REGULATIONS IS THE SOLE RESIOMMUTY ON THE CONTRACTOR. STRUCTURAL AL INSPECTIONS ('SPECIAL THRESHOLD INSPECTOR'1: 1. BASED ON THE REQUIREMENTS OF THE FBC AND THE LOCAL CODE ENFORCEMENT DEPAR" WENT, THIS PROJECT REQUIRES THRESHOLD NSPECTIONS TO BE MADE DURING THE CONSTRUCTION OF ALL THE STRUCTURAL ELEMENTS (AS LISTED HEREIN OR ELSEWHERE IN THESE DOCUMENTS). 1 IN ORDER TO COMPLY WITH THE ABOVE REQUIREMENTS THE OWNER SHALL RETAIN THE SERVICES OF A LICENSED STRUCTURAL ENGINEER FOR THE PURPOSE OF PERFORMING THE REQUIRED INSPECTION SERVICES. 3. THE ASSIGNED STRUCTURAL INSPECTOR SHALL BE NOTIFIED BY THE CONTRACTOR, AT LEAST 24 HOURS PRIOR TO ANY CONCRETE PLACING OR OTHER OPERATIONS THAT WILL CONCEAL STRUCTURAL ELEMENTS. 4. THE INSPECTIONS MADE BY THE 'SPECIAL THRESHOLD INSPECTOR- ENGINEER (ENGAGED BY THE OWNER) ARE IN ADDITION M THE INSPECTIONS MADE BY THE LOCH. BUILDING DEPARTMENT. THE CONTRACTOR SHALL COORDINATE THE INSPECTION REQUIREMENTS WITH THE LOCAL BUILDING DEPARTMENT. THE CONTRACTOR SHALL NOTIFY THE BUILDING DEPARTMENT ANY TIME THE ENGINEER HAD BEEN SCHEDULED FOR A SITE VISIT. CONTRACTOR SHALL TIME SCHEDULE THE STE MST OF THE ENGINEER BEFORE THE BUILDING DEPARTMENT INSPECTOR 5. A 'STATEMENT OF INSPECTION". 'INSPECTION LOG' AND ANY OTHER DOCUMENTS REQUIRED BY THE PERMIT. WILL BE ISSUED AT A TIMELY SCHEDULE OR AT THE COMPLETION OF THE STRUCTURAL WORK. FOR THE ELEMENTS THAT HAVE BEEN INSPECTED DURING THE COURSE OF THE CONSTRUCTION (AS REQUESTED BY THE CONTRACTOR OR AS REQUIRED BY THE BUILDING DEPARTMENT OR PERMIT DOCUMENTS). 6. WHEN G.D. KLEGER, INC. (THE ENGINEER -O°- RECORD) WAS NOT ENGAGED TO PROVIDE REQUIRED JOB -STE INSPECTION SERVICES, G.D.K. WILL NOT BE HELD RESPONSIBLE AND LIABLE FOR ANY OF THE CONTRACTOYS WORK. G.D.K. SHALL ALSO NOT BE HELD RESPONSIBLE FOR ANY WORK APPROVED BY THE INSPECTING ENGINEER (OTHER THAN THE ENGINEER -CF- RECORD) WHICH MODIFIES OR CHANGES THE STRUCTURAL PERMIT RECORD DOCUMENRS. WITHOUT PRIOR REVIEW AND ACCEPTANCE (IN WRITING) BY THE ENGINEER -O'- RECORD. SPECIAL THRESHOLD INSPECTION PLAN 1. SOIL COMPACTION (INSPECTION BY A FOUNDATION ENGINEER) 1 REINFORCED CONCRETE FOOTINGS: REINFORCING AND CONCRETE PLACEMENT. 3. REINFORCED CONCRETE SLABS: REINFORCING AND CONCRETE PLACEMENT 4. FORMWORK, SHORES AND RESROtES: INSPECT FORMWORK, SHORING AND BRACING (AS PER SHORING PLAN SHOP DRAWINGS). 5. CONCRETE COLUMNS- REINFORCING AND CONCRETE PLACING 6. MASONRY AND REINFORCED MASONRY: BLOCK HORIZONTAL AND VERTICAL REINFORCING. CELL GROUTING 7. CONCRETE BEAMS & WALLS: REINFORCING AND CONCRETE CASTING & MISC. CONCRETE ELEMENTS (STARS, ETC.} REINFORCING AND CONCRETE CASTING 9. INCIDENTAL CONCRETE. STEEL OR ALUMINUM STRUCTURAL ELEMENTS AS INDICATED ON THE PLANS OR SHOP DRAVVVNGS. 10. EXTERIOR DOORS, WINDOWS & STOREFRONT: INSTALLATION AND ATTACHMENT TO THE SURROUNDING STRUCTURE 11. PRECAST UNITS (JOISTS AND BEAM SOFFITS): REINFORCING, TENSION CABLES AND CASTING OF CONCRETE (AT THE CASTING YARD) AND INSTALLATION AT THE PROJECT SITE STRUCTURAL INSPECTIONS - CONT.: 'SPECIAL INSPECTION' REOUIREMUM (MIAMI -DARE AND BROWARD COUNTY ONLY - FBC 2010) IF THE LOCAL BUILDING DEPARTMENT REQUIRES - SPECIAL INSPECTIONS' (N ADDITION M THE LISTED AS 'THRESHOLD INSPECTIONS-). THEY WILL INCLUDE THE REIMS LISTED BELOW. A. PRECAST UNITS (FOR QUALITY CONTROL AT CASTING YARD) - (s) B. PRECAST UNITS AND ATTACHMENTS M MAIN STRUCTURE (AFTER ERECTION BUT BEFORE CONCEALMENT) - (') C. REINFORCED MASONRY - (0) D. STEEL CONNECTIONS (BOLTED & WELDED) - (*) E SOIL COMPACTION - (-) (4) ITEM INSPECTED BY A FLORIDA REGISTERED ARCHITECT OR PROFESSIONAL ENGINEER (-) INSPECTION M BE PERFORMED BY A GEOTECHNICAL ENGINEER SEE THE SPECIFIC COUNTY OR CITY FOR THEIR FORM FOR 'SPECIAL INSPECTOR- SERVICES. M BE PART OF THE PERMIT PLANS REQUIRED DELEGATED ENGINEERED CALCIA •TIONS AND SHOP DRAWINGS- THIS PROJECT REQUIRE THE FOLLOWING DELEGATED ENGINEERED CALCULATIONS AND SHOP DRAWINGS, BASED ON THE 'FLORIDA ADMINISTRATIVE CODE', SECTIONS 61G15 -30 AND SIG15 -31 (ONLY THE ITEMS MARKED [X] APPLY} [ ] WOOD TRUSSES, GIRDER TRUSSES AND PREFABRICATED WOOD COMPONENTS (61G15- 31.003) STEEL BAR-JOISTS AND STEED. GIRDER- TRUSSES (61G15- 31.006) COLD -FORM STUD TRUSSES. JOISTS AND /OR WALLS (61G15- 31.009) [ STRUCTURAL STEEL SYSTEM (61G15- 31.009) ] PRE-ENGINEMED METAL BUILDINGS 1X] PRE - ENGINEERED CONCRETE FLOOR (/ROOF SnTEM. INCLUDING CONCRETE GIRDERS, PRECAST ELEMENTS, COMPOSITE ELEMENTS, ETC. (61G15 -- 31.005, 31.007 & 31.009) OR F -ATED ENGINFERED CERVICES. REOIITRm FOR THIS PROJECT- (BASED ON CHAPTER 61615 OF THE - FLORIDA ADMINISTRATIVE CODE-) NOTE THAT THE LANGUAGE USED BELOW IS NOT ALWAYS A DIRECT COPY FROM THE ADMINISTRATIVE CODE. THE DELEGATED ENGINEER SHALL BE FAMILIAR WITH THE CODE AS PUBLISHED IN THE STATE OF FLORIDA. 'EOR' - DENOTES 'ENGINEER -O"- RECORD' 'DE- - DENOTES 'DELEGATED ENGINEER' 81615- 30.005: REOLIFCT FOR & REVIEW OF DELGATM ENGINEERING DOCUMENTS 1. PORTIONS OF THIS STRUCTURAL DESIGN AND DETAILING ARE BEING DELEGATED TO A 'DE'. THE ENGINEERING DESIGN REQUIREMENTS HAVE BEEN INCLUDED IN THESE DOCUMENTS (PLANS. DETAILS, SECTIONS AND NOTES). 1 ALL DELEGATED ENGINEERING DOCUMENTS. PREPARED BY THE 'DE' SHALL BE SUBMITTED TO THE 'EON' M BE REVIEWED FOR COMPLIANCE WITH THE PROJECT DESIGN REQUIREMENTS AND TO CONFORM WITH THE FOLLOWING: 11 THAT THE DELEGATED ENGINEERING DOCUMENTS HAVE BEEN PREPARED BY A 'PROFESSIONAL ENGINEER- (LICENSED N THE STATE OF FLORIDA). (*-) 12 THAT THE DELEGATED ENGINEERING DOCUMENTS PREPARED BY THE 'W CONFIRM WITH THE DESIGN INTENT OF THE 'EOR' AND MEET THE WRITTEN REQUIREMENTS. 13 THAT THE EFFECT OF THE 'DE- WORK ON THE OVERALL PROJECT, GENERALLY CONFORMS WITH THE INTENT OF THE 'EOR -. SOLE RESPONSIBILI� THE 'DE (AND NOT OR-) M ASSURE EAAND DEMONSTRATE (F REQUIRED) THAT HIS/HER LICENSE IS ACTIVE N THE STATE OF FLORIDA. 61G15 -30. 008: DELEGATED ENGINEER'S RESPONSIBIUTY 1. THE 'DE' SHALL REVIEW THE 'EOR' WRITTEN ENGINEERING REQUIREMENTS M DETERMINE THE APPROPRIATE SCOPE OF THE DELEGATED ENGINEERING WORK. 1 THE DELEGATED ENGINEERING DOCUMENTS SHALL COMPLY WITH THE DESIGN DOCUMENTS PREPARED BY THE 'EOR'. THEY SHALL INCLUDE THE PROJECT IDENTIFICATION AND THE DESIGN CRITERIA USED IN ITS PREPARATION. F THE DETERMINES THERE ARE DETAILS. FEATURES OR UNANTICIPATED PROJECT LIMITS CONFLICTING WITH THE 'EOR' PLANS. THE 'DE' SHALL TIMELY CONTACT THE TOR- FOR RESOLUTIONS OF CONFLICTS. (-) 3. THE 'DE• SHALL FORWARD THE DELEGATED ENGINEERING DOCUMENT M THE TOR' FOR REVIEW. ALL FINAL DELEGATED ENGINEERING DOCUMENTS REQUIRE THE IMPRESSED SEAL AND SIGNATURE OF THE -DE' AND INCLUDE &I DRAWINGS INTRODUCING ENGINEERING INPUT SUCH AS DEFINING THE CONFIGURATION OR STRUCTURAL CAPACITY OF STRUCTURAL COMPONENTS AND /OR THEIR ASSEMBLY INTO STRUCTURAL SYSTEMS 12 CALCULATIONS. 3.3 COMPUTER PRINTOUTS (COMPLEMENTING OR INSTEAD OF MANUAL CALCULATIONS) ACCOMPANIED BY SUFFICIENT DESIGN ASSUMPTIONS AND IDENTIFIED INPUT /OUTPUT INFORMATION TO PERMIT THEIR PROPER EVALUATION. 3.4 SUCH INFORMATION SHALL BEAR THE IMPRESSED SEAL AND SIGNATURE OF THE 'DE' AS AN INDICATOR THAT SAD ENGINEER HAS ACCEPTED RESPONSIBILITY FOR THE RESULTS (COIIAUN� TH��QUES OWS OR ADDITIONAL INFORMATION REWIREMENTS, ON A TIMELY MANNER TO THE -EOR- (MATH COPIES TO THE CONTRACTOR). WjE; BASED ON SECTION 61G15- 31.002 (DEFINITIONS). ITEM (6} STRUCTURAL SUBMITTALS WHICH DO NOT REQUIRE THE SEAL OF A PROFESSIONAL ENGINEER, INCLUDE (a) DRAINING PREPARED SOLELY TO SERVE AS A GLADE FOR FABRICATION AND INSTALLATION AND REQUIRE NO ENG 03MG INPUT SUCH AS REINFORCING STEEL SHOP DRAWINGS, STRUCTURAL STEEL AND STEEL JOIST AND ORDER ERECTION DRAWINGS SIG15- 31.00S DESION OF STRUCTURES UTIH71NO PRECAST AND PRESTRESSED CONCRETE COMPONENTS- 1. STRUCTURAL ENGINEERING DOCUMENTS INDICATE THE CONFIGURATION OF PRECAST AND PRESTRESSED COMPONENTS 1 THE RESPONSIBILITY FOR THE DESIGN OF PRECAST OR PRESTRESSED CONCRETE COMPONENTS OR SYSTEMS UTLMNG THOSE COMPONENTS, ARE BEING DELEGATED TO A 'DE'. THE SHALL PROVIDE TO THE 'EOR' ALL ENGINEERING DOCUMENTS FOR THE DESIGN AND DETAILING OF THE ABOVE, FOR 'EOR' REVIEW AS AN INDICATION THAT THE INTENT OF THE 'EOR' HAS BEEN UNDERSTOOD AND THAT THE SPECIFIED CRITERIA HAVE BEEN USED. STRUCTURAL 'DE' DOCUMENTS SHALL BEAR THE IMPRESSED SEAL AND SIGNATURE OF THE DELEGATED ENGINEER 3. STRUCTURAL 'W DOCUMENTS SHALL INCLUDE COMPONENT DETAILS, CALCULATIONS, FABRICATION AND ERECTION DRAWINGS ALL SUCH SUBMITTALS SHALL IDENTIFY THE SPECIFIC PROJECT. THE EFFECTS OF THE PRECAST AND PRESTRESSED CONCRETE MEMBERS ON OTHER PARTS OF THE BUILDING IS THE RESPONSIBILITY OF THE 'EOR' FOR THE STRUCTURE 4. THE 'DE' SHALL CLEARLY INDICATE ALL THE LOADS, REACTIONS. ATTACHMENT REQUIREMENTS (TO THE STRUCTURE DESIGN BY THE -EOR-) AND ALL INFORMATION DERIVED FROM THE PRECAST AND PRESTRESSED DESIGN, AFFECTING THE STRUCTURE DESGNED BY THE 'ECR'. 61G15- 31.006 ODIFED} DESGN OF ALUMINUM OR STEEL AWNINGS CANOPIES OVERHANGS AND FACADE: 1. THE ARCHITECTURAL/STRUCTURAL DRAWINGS OF- RECORD INDICATE THE ELEMENTS LOCATION. CONFIOJRATION. DIMENSIONS. GENERAL APPEARANCE AND ELEMENTS OF THE ABOVE TITHES ELE1tE M POSTS, HANGERS, BRA00% SUPPORTING WALLS AND BEAMS ALL DESIGN LOADS ARE ALSO INCLUDED. 1 THE SYSTEM MANUFACTURER'S/SUPPLER'S -DE' SHALL DESIGN THE ENTIRE SYSTEM INCLUDING ALL THE BEAM/JOIST/RAFLER ELEMENTS, DECKING /GRATING /COVERS AND ALL INTERNAL AND EXTERNAL CONNECTIONS (INCLUDING M THE STRUCTURE) IN ACCORDANCE WITH THE SPECIFICATIONS, LOAD TABLES AND COMPUTER DATA M SUPPORT THE LOADS PER THE 'EOR' SPECIFICATIONS. THE 'EOR' REQUESTS THE SUBMISSION OF THE ENTRE SYSTEM DESIGN CALCULATIONS (FOR EACH COMPONENT AND CONNECTIONS) AS AN INDICATION OF COMPLIANCE THE SYSTEM MMUFACTURER'SPPUER'S 'DE' SHALL SUBMIT A COVER LETTER ALONG WITH THE CALCULATIONS. THE COVER LETTER SHALL BEAR THE SEAL AND SIGNATURE OF A FLORIDA PROFESSIONAL ENGINEER RESPONSIBLE FOR THE DESIGN OF THE SYSTEM. FOUNDATIONS: (SPREAD FOOTINGS) THESE RECOMMENDATIONS ARE BASED ON SOIL EXPLORATION AND FOUNDATION RECOMMENDATIONS, MADE BY: *ALL STATE ENGINEERING & TESTING CONSULTANTS INC.' (REPORT DATED: 10- 8- 2012). N THE EVENT OF A DISCREPANCY BETWEEN THESE REQUIREMENTS AND THE REQUIREMENTS N THE GEOTECHNICAL REPORT, THE MORE STRINGENT SHALL BE USED. 1. FOUNDATIONS ARE DESKINM M BEAR ON WELL COMPACTED GRADE OR CLEAN FILL PREPARED M ACHIEVE A MINIMUM ALLOWABLE BEARING CAPACITY OF 2,500 A CERTIFIED TESTING LABORATORY SHALL BE ENGAGED BY THE OWNER TO VERIFY THAT THE REQUIRED BEARING CAPACITY WAS OBTAINED. SAID SOIL CAPACITY SHALL BE CERTIFIED AND TESTED BY A REGISTERED FOUNDATION ENGINEER, PRIOR TO CASTING OF CONCRETE N THE FOOTINGS 1 NATURAL GRADE (OR FILL) BELOW FOOTINGS SHALL BE COMPACTED TO A MINIMUM OF 98% MODIFIED PROCTOR (ASTM D- 1557). 3. TOP OF WALL FOOTINGS TO BE AT THE SAME ELEVATION AS TOP OF COLUMN PAD FOOTINGS STEP WALL FOOTING FROM HIGHER COLUMN FOOTING TO THE LOWER ONE (AS DETAILED ON THE PLANS). 4. TOP OF ALL FOOTNM TO BE A MINIMUM 1' -e BELOW THE TOP OF CONCRETE SLAB ON GRADE (UNLESS OTHERWISE NOTED TO BE AT LOWER ELEVATION OR CAST MONOLITHIC WITH SLAB) OR MINIMUM V -0' BELOW FINISHED GRADE. WHICHEVER IS LOWER. IN THE EVENT THAT THE SLAB _STEPS ON EACH SDE OF THE FOOTING THE FOOTING SHALL BE V -4' BELOW TOP OF THE LOWER SLAB. TO ACCOMMODATE A CONTINUOUS WALL FOOTING, A STEPPED FOOTING MAY BE REQUIRED (SEE DETAIL ON PLAN). 5. REINFORCING IN THE CONTINUOUS WALL FOOTINGS (MONOLITHIC AND /OR NON- MONOLITHIC) SHALL BE SPUCED 36 BAR DIAMETERS MINIMUM AND SHALL EXTEND CONTINUOUSLY THRU ALL FOOTING PADS 6. ALL LONGITUDINAL REBARS IN THE CONTINUOUS WALL FOOTINGS, SHALL BE CONTINUED AT BENTS AND CORNERS BY BENDING THE REHABS 48 BAR DIAMETERS AROUND THE CORNERS OR ADDING MATCHING CORNER BARS, EXTENDING 48 BAR - DIAMETERS INTO FOOTING EACH SIDE OF CORNER OR BENT. 7. ALL FOOTINGS (MONOLITHIC OR NOT) SHALL BE 12' MINIMUM THICK. CONCRETE NONI-STRUCTURAL SLABS ON AIDE 1. ALL NON - STRUCTURAL CONCRETE SLABS AND WALKWAYS ON GRADE, AS SHOWN ON THE STRUCTURAL AND /OR ARCHITECTURAL PLANS, SHALL BE AS FOLLOWS: INTERIOR S 4- THICK, RENT. W/ 6x6- WI.4xWI.4 GALVANIZED WELDED WIRE FABRIC (UNLESS OTHERWISE NOTED). EXTERIOR SLABS AND WALKS 4- THICK, REINF. W/ 6x6- WI.4xWI.4 GALVANIZED WELDED WIRE FABRIC (UNLESS OTHERWISE NOTED). INTERIOR DRIVEWAY (CAR LAW . 6- THICK, REINF. W/ 6x6- W29xW29 GA.VANrM WELDED WIRE FABRIC (UNLESS OTHERWISE NOTED). 2 ALL SLABS ON GRADE M BE CONSTRUCTED N ACCORDANCE WITH LATEST A.C.1 - 'GUIDE FOR CONCRETE FLOOR AND SLAB CONSTRUCTION' (A.w. - 3011R). 3. JOINTS SHALL BE PROVIDED IN ALL INTERIOR SLABS ON GRADE AT ALL COLUMN CENTQBJNES DIVIDING THE STAB INTO SQUARE PANELS NOT M EXCEED 18 X 18 FT. N SIZE (U.O.N.). CAST SLAB IN LONG ALTERNATE STRIPS PROVIDE A CONTRACTION JOINT BETWEEN EACH STRIP. SEE PLAN FOR SAW -CUT, CONTRACTION AND ISOLATION JOINT DETAILS 4. PROVIDE SAW -CUT JOINTS AT ALL SIDEWALKS AT A MAXIMUM SPACING OF FIVE FEET ON CENTERS AND ISOLATION JOINTS AT 20 FEET O.C. (U.O.N.). 5. FILL MATERIAL SHALL BE PLACED IN LIFTS NOT EXCEEDING 12' AND 8. COMPACTED M MINIMUM 95XT MODIFIED PROCTOR (ASTM D -1557) WITHIN A DISTANCE OF 3 FEET BEYOND ALL FOOTING EDGES COORDINATE THESE REQUIREMENTS WITH THE GEOTECHNICAL REPORT AND RECOMMENDATIONS. TAKE AT LEAST ONE DENSITY TEST FOR EACH 2,500 SQ.FT. OF AREA AND 1r BELOW SURFACE SEND RESULTS OF THE TEST TO OWNER, ARCHITECT AND ENGINEER CONCRETE AND REMFORCING 1. CONCRETE DESIGN AND REINFORCEMENT IN ACCORDANCE WRHH 'BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE• (A.C.I. 318) AND WITH 'DETAILS AND DETALNG OF CONCRETE REINFORCEMENT'- (A.C.1 315 - LATEST EDITION). 1 ALL CONCRETE WORK IN ACCORDANCE WITH 'SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDING! (A.C.I. 301). PRODUCTION OF CONCRETE, DELIVERY, PLACING AND CURING TO BE IN ACCORDANCE WITH 'HOT WEATHER CONCRETING' (A.C.I. 305R). 3. ALL REINFORCING M BE NEW BILLET STEEL CONFORMING TO THE LATEST A.ST.M. A -615 GRADE 60. FABRICATED IN ACCORDANCE WITH C.R.&L MANUAL OF STANDARD PRACTICE AND PLACED N ACCORDANCE WITH A.C.I. 315 AND C.RSL MANUAL OF STANDARD PRACTICE 4. ALL REINFORCING SHALL BE DEFORMED BARS, CLEAN OF 011. SCALE AND RUST. 5 • DOWELS TO BE SAME SIZE AND NUMBER AS VERTICAL REBARS ABOVE LAP 36 BAR DIAMETER OR MINIMUM OF 18 INCHES. U.O.N. PROVIDE RIGID TEMPLATES FOR COLUMN DOWEL LOCATION. PROVIDE STANDARD HOOKS AT TOP OF ALL VERTICAL. REINFORCEMENT AT NON-CONTINUOUS COLUMNS (U.0.N.). 5.1 ADD 2 SETS OF TIES (SPACED AT r O.C. MAX) BEACH THE 'OFFSET -BENT' N THE VERTICAL REBARS. AT THE LAP LOCATION WITH THE CAGE ABOVE. TIE- COLUMNS (CONSTRUCTED WITH NO -OFFSET -BENT' DO NOT REQUIRED ADDED TIES). 5.2 UNLESS OTHERWISE INDICATED ALL COLUMNS SHALL BE EXTENDED TO THE TOP OF THE ROOF PARAPET. 5.3 ALL DOWELS FOR COLUMNS SHALL BE SECURED IN P097ION PRIOR TO CONCRETING PUSHING THE DOWELS INTO POSITION N WET CONCRETE IS NOT PERMITTED. & BEAM REINFORCEMENT: LAPPED 36 BAR DIAMETER OR MINIMUM 18 INCHES (SEE BEAM DIAGRAM ON PLAN). BOTTOM BARS SPLICED ONLY AT SUPPORTS, TOP BARS SPLICED ONLY AT MID -SPAN. ALL TOP BARS HOOKED AT NON- CONTINUOUS EDGES (U.0.N.). ALL HOOKS TO BE STANDARD 90 OR 180 DEGREE HOOKS AS REQUIRED (=K). TIES OR STIRRUPS SHALL BE SPACED AS INDICATED ON THE BEAM SCHEDULE, MEASURED FROM SUPPORT TO SUPPORT (U.0.N.). EXAMPLE 406' O.C. EE BAL 012' D.C. MEANS 4 TIES AT 6' O.C. AT EACH END OF EACH SPAN, WITH TIES AT 1r O.C. IN THE MIDDLE (BETWEEN THE TWO END SUPPORTS1 CONTACT ENGINEER IF THIS REQURE FURTHER CARIFICATION& 7. ADDED REINFORCEMENT: PROVIDE ADDITIONAL CORNER BARS BENT 36 INCHES MINIMUM EACH WAY AT -L' AND i CORNERS N OUTER FACES OF ALL BEAMS TO MATCH ALL HORIZONTAL BAR (TOP, BOTTOM AND INTERMEDIATE REBARS). & UNLESS OTHERWISE SPECIFICALLY INDICATED ON THE PLANS OR DETAILS, ALL REBAR END HOOKS SHOWN OR REQUIRED AT ALL TYPES OF REINFORCED CONCRETE ELEMENTS SHALL BE THE ACI STANDARD LENGTH FOR 90 OR 180 DEGREES HOOKS SLAB TEMPERATURE REINFORCING: ALL S LABS SHALL HAVE TEMPERATURE REINFORCING PERPENDICULAR M THE DIRECTION OF THE MAN R03M (U.O.N. ON PLANS TEMPERATURE REINFORCING M BE AT MINIMUM /4 AT 12' O.C. IN SLABS UP 70 8' THICK. 9. CONCRETE IF BEAM: A MINIMUM CONCRETE TIE BEAM (AS SPECIFIED HEREIN) SHAT BE PROVIDED AT EACH FLOOR OR ROOF LEVEL, IF A BEAM WAS NOT CALLED FOR ON THE PLANS. THE TIE BEAM SHALL BE A MINIMUM OF 8' X 1r, REINFORCED WITH (2)-05 TOP AND BOTTOM AND 13 TIES, (4) AT 12' O.C. EACH END, BALANCE AT 48' O.G. DROP BOTTOM OF THE BEAM OVER OPENINGS, ADD (2)-05 BOTTOM AND j3 TES AT 6. D.C. THRUO UL THESE BEAUS ARE NOT N ADDITION TO BEAMS ALREADY INDICATED AND SCHEDULED ON THE PUNS FOR THE SAME LOCATION. 10. CURING & PROTECTION: ALL STRUCTURAL SUBS AND SLABS -ON -GRADE SHALL BE CURED WITH MOIST BURLAP COVER (KEPT MOIST FOR 7 DAYS). SPRAY ON CURING COMPOUNDS (INCLUDING CURING/SEALERS/HARDENERS) MAY BE CONSIDERED. CONTRACTOR M SUBMIT M ARCHITECT/ENGINEER MATERIAL SPECIFICATIONS AND DATA, FOR REVIEW AND ACCEPTANCE PRIOR M APPLICATION. NO SLAB CONCRETE SHALL BE LET TO DRY WITHOUT ANY CURING 11. CONCRETE COVER (UNLESS OTHERWISE DETAILED ON DRAWINGSZ ELEMENT: CONCRETE COVER TOP BOTTOM SDES REMARKS WALL & COLUMN PAD FOOTING 2 2 TO ACCOMMODATE CAMBERS WHEN IT BECOMES NECESSARY. NON- STRUCT. SLAB -ON -GRADE MID -DEPTH AT 28 DAYS BEAMS COLUMNS TO TIES 1 -1 ALL AROUND 18 ELEVATED SLABS INTERIOR ,r 1 STRENGTH: ELEVATED SLABS EXTERIOR 1-1/f 1 -1 2 LP M NO. 5 BARS ELEVATED SLABS 1 r r NO. 6 AND LARGER BARS CONCRETE TMN 1. CONCRETE SHALL BE TESTED FOR STRENGTH. MINIMUM OF 4 CYLINDERS SHALL BE MADE FOR EACH 50 CU.YDS. OF CONCRETE (OR AT LEAST ONE PER DAY, F LESS THAT 50 CUNDS.). TEST IN ACCORDANCE WITH ASTM C-39. SUBMIT ALL TEST RESULTS N A TIMELY MANNER, M THE A/E FOR REVIEW. 1.1 TESTING AGENCY WILL BE SELECTED AND PAD FOR BY THE OWNER. TESTS AND INSPECTIONS UNDER DIRECT CONTROL OF THE OMMER. RESULTS OF ALL TESTS SHALL BE SENT M THE OWNER, OWNER'S REPRESENTATIVES AND THE CONTRACTOR CONTRACTOR SHALL NOTIFY LABORATORY AT LEAST TWENTY FOUR (24) HOURS BEFORE EACH SCHEDULED CONCRETE PLACING. 1.2 MAID= ONE SET OF FOUR (4) CYLINDERS AND ONE (1) SUMP TEST FOR THE FOLLOWING: 1.2.A. EACH CLASS OF CONCRETE PLACED EACH DAY, NOT LESS THAN ONCE A DAY. 1.18. NOT LESS THAN ONCE FOR EACH 50 CUBIC YARDS OF CONCRETE OR PORTIONS THEREOF. 1.1C. NOT LESS THAN ONCE FOR EACH 5,000 SQUARE FEET OF SURFACE AREA FOR SLABS 1.3 SAMPLES FOR THE TESTS SHALL BE OBTAINED FROM A DIFFERENT BATCH OF CONCRETE SELECTED ON A RANDOM BASS, TAKEN AT 1/4 AND 3/4 POINTS OF THE LOAD N MIXER 1.4 TEST ONE (1) CYUNDER AT SEVEN (7) DAYS AND TWO (2) AT TWENTY EIGHT (28) DAYS. HOLD ONE (1) CYLINDER FOR TESTING AT FORTY -FIVE (45) DAYS IF THE 28 DAYS TESTS FAIL TO MEET SPECIFIED STRENGTH. ADDITIONAL CYLINDER TESTS THAT MAY BE REQUIRED BY THE CONTRACTOR (FOR FORMS AND SHORING REMOVAL) SHALL BE ORDERED AND PAD FOR BY THE CONTRACTOR. 1 EVAWA71ON AND ACCEPTANCE OF CONCRETE 11 N THE EVENT THAT THE CONCRETE SLUMP AND/OR CONCRETE HAD EXCEEDED THE SPECIFIED DEPOSIT TIME. THE ON-97E TESTING LAB TECHNICIAN SHALL IMMEDIATELY NOTIFY THE CONTRACTOR'S ON-SITE RE TMMTA71VE WINO SHALL REJECT THE NON- COMPLYING CONCRETE. 12 F CONCRETE TESTS ARE INSUFFICIENT OR INADEQUATF. IN PUCE CONCRETE SHALL BE TESTED AND EVALUATED BY QBE-IEST$ USE OF ONLY THE - SVASS- HAMMER' OR WINDSOR PROBE' ARE NOT ACCEPTABLE WITHOUT THE ADDED CORE TESTING FOR COMPARATIVE RESULTS. FAILURE OF ANY CONCRETE TO MEET SPECIFIED REQUIREMENTS SHALL BE DEEM NON- COMPLYING AND COSTS OF ADDITIONAL TESTS TO DETERMINE ADEQUACY OR INADEQUACY SHALL BE BORNE BY THE CONTRACTOR. 13 CONCRETE REJECTED FOR ANY REASON SHALL BE REMOVED AND REPLACED. LABOR, NEW FORMS AND REINFORCING REQUIRED TO MEET SPECIFICATIONS SHALL BE PROVIDED BY THE CONTRACTOR, AT NO ADDITIONAL COST M OWNER AND AT NO TIME EXTENSION TO THE PROJECT. PRECAST CONCRETE UNITS - GENERAL REQUIREMENTS 1. ALL PRECAST UNITS (INDIVIDUAL UN17S OR SYSTEMS) SHALL BE DESIGNED BY THE CONTRACTOR'S OR THE PRECAST MANUFACIURER'S DELEGATED STRUCTURAL ENGINEER. THE DELEGATED ENGINEER SHALL BE A FLORIDA LICENSED ENGINEER HAVING A MINIMUM OF THREE (3) YEARS OF EXPERIENCE IN THE DESIGN OF THE PARTICULAR ELEMENT(S). 1 SUBMIT SHOP DRAWINGS, ALL CALCULATIONS AND COMPUTER PRINTOUTS PREPARED BY AND SIGNED AND SEALED BY THE DELEGATED STRUCTURAL ENGINEER. COMPUTATIONS SHALL BE MADE FOR EACH MEMBER AND FOR THE SYSTEM (AS APPLICABLE ENCLOSE A LEGEND OR A DESCRIPTION OF ALL ABBREVIATIONS AND NOMENCLATURES, USED IN THE CALCULATIONS AND COMPUTER INPUT /OUTPUT. 3. PRESTRESSED UNITS STALL BE DESIGNED AND MANUFACTURED N ACCORDANCE WITH THE REQUIREMENTS OF THE BUILDING CODE, P.C.L MANUAL AND A.C.T. CODE MEMBERS SHALL BE DESIGNED TO CARRY OWN WEIGHT AND ALL SUPERIMPOSED DEAD LOADS PLUS LIVE LOADS ALL MEMBERS SHALL ALSO BE DESIGNED TO CARRY ALL EXPECTED CONSTRUCTION PHASE LOADS 4. SHOP DRAWINGS SHALL SHOW AND SPECIFY CONCRETE TYPE AND STRENGTH, REINFORCING (REHABS AND CABLES), ANCHORAGE, STEEL INSERTS, CONCRETE COVERS. CABLE DEPRESSIONS. BEARING DIMENSIONS, PLAN LAYOUT AND LOCATION OF EACH PRECAST MEMBER. CONNECTION M OTHER STRUCTURES AND SUPPORTS. ALL PENETRATIONS (AS REQUIRED BY OTHER TRADES) LOAD TRANSFERRING COMPONENTS, DESIGN LOADS AND OTHER RELATED INFORMATION ALSO SHOWN ON THE STRUCTURAL PLANS 5. ALL LOADS AND REACTIONS APPLIED BY THE PRECAST ELEMENTS ONTO THE SUPPORTING STRUCTURE, SHALL BE CLEARLY INDICATED ON THE SHOP DRAWINGS IF REQUIRED. THE ENGINEER -OF- RECORD SHALL ADJUST THE MAN STRUCTURE TO SUPPORT SAID LOADS & DELEGATED ENGINEER SHALL ALSO DESIGN AND WCATE ON THE SHOP DRAWINGS, ALL TEMPORARY SHORING. TEMPORARY ATTACHMENTS, FORMWORK, BRACING AND RE9HORES (INCLUDING TIME FOR REMOVAL THEREOF) AS REQUIRED FOR SAFE ERECTION OF THE PRECAST UNITS AND /OIL THE SYSTEM. 7. NO FABRICATION OF PRECAST COMPONENTS SHALL BEGIN. UNTIL ALL SHOP DRAWINGS AND CALCULATIONS HAVE BEEN REVIEWED BY THE ENGINEER -OF- RECORD AND THE ARCHITECT. & ALL METAL CONNECTIONS SHALL BE RUST -PROOF PANTED. ALL FIELD WELDS SHALL BE WIRE- BRUSED CLEAN AND RUST -PROOF PANTED. TOUCH UP WITH RUST -PROOF PANT ALL COATED STEEL WITH PANT DAMAGED DURING TRANSPORTATION. ERECTION OR ADJACENT WELDING OPERATIONS ALL WELD SHALL BE INSPECTED BY A CERTIFIED WELDING INSPECTOR 9. PRECAST UNITS PLACED IN STRUCTURES LOCATED N CORROSIVE ATMOSPHERES (SUCH AS EASTWARD OF THE COASTAL BUILDING CONSTRUCTION LINE) SHALL HAVE COATED REINFORCING OR SPECIALLY DESIGNED CONCRETE MIX 10. ALL PRECAST COMPONENTS, SHALL BE INSPECTED FOR QUALITY CONTROL. BY THE DELEGATED ENGINEER, PRIOR M CASTING OF CONCRETE AT THE CASTING YARD. A COMPLETE RECORD SET OF MATERIAL, STRESSING AND CONCRETE TESTNG SHALL BE PROVIDED M THE DELEGATED ENGINEER AND THE ENGINEER-OF-RECORD. TEES TESTS SHALL BE AVAILABLE M THE BUILDING OFFICIAL WRING HIS INSPECTIONS AND FOR 7 YEARS AFTER COMPLETION OF THE PROJECT. 11. CONTRACTOR TO NOTE THAT ALL PRECAST - PRESTO BEAM OR JOIST ELEMENTS WILL HAVE A CAMBER THE EXTENT OF SUCH CAMBER MAY BE CONTROLLED BY THE ELEMENT DESIGNER (TO A CERTAIN DEGREE) BUT CANNOT BE ASSURED. WHERE DIFFERENT BUILDING ITEMS ARE TO BE CONNECTED M SUCH PRECAST ELEMENTS AND MAY BE AFFECTED BY THE DEGREE OF THE CAMBER, THE CONTRACTOR SHALL COORDINATE THE 11 ALL CONCRETE TO BE REGULAR WEIGHT WITH A DESIGN STRENGTH AS FOLLOWS- CAMBERS WITH THE PC DESIGNER/UANUFACTURER TO MINIMIZE POTENTIAL UNEXPECTED CAMBERS AND ALLOW FOR ADDITIONAL SHIMS, SPACERS. BUCKS, ETC. (INCLUDING LABOR) REQUIREMENTS FOR SPECIAL EXPOSURE CONDITIONS (ACI-318. SECTION 4.2 TABLE 4.211: A TESTING LABORATORY SHALL BE ENGAGED TO TAKE SOIL CAl 4 FS. TEST AND REPORT THE CALCIUM AND SULFATE CONTENTS IN THE SOIL TO BE IN CONTACT WITH THE NEW CONCRETE F FOUND EXCEEDING ACI-318 MINIMUM ALLOWED, ALL CONCRETE PLACED IN CONTACT WITH THE GROUND EXPOSED TO SALT WATER, SEAWATER OR SPRAY FROM THESE SOURCES, SHALL HAVE A MAXIMUM WATER /CEMENT RATIO OF 0.40, IN ADDITION TO STRENGTH AND SLUMP REQUIREMENTS INDICATED ABOVE. NOTE: THE PILES SHALL BE DRIVEN INTO GROUND FIRST, BEFORE ANY COMPACTION WORK AND EXCAVATION FOR THE SHALLOW SPREAD FOOTING COORDINATE WORK AND SEQUENCE WITH THE GEOTECHNICAL ENGINEER. 1. SCOPE; 1.1 FURNISH ALL LABOR, MATERIALS, EQUIPMENT, INCIDENTALS, TRANSPORTATION, ERECTION/INSTALLATION AND SUPERVISION NECESSARY M COMPLETE ALL PILING AND RELATED WORK CALLED FOR ON THE PLANS OR HEREIN OR REASONABLY INFERABLE FROM EITHER OR 807H, INCLUDING BUT NOT LIMITED TO THE FOLLOWING: (A) AUG ERED-CAST GROUTED PILES. (B) ACCURATE LAYOUT AND INSTALLATION OF ALL PILES. (C) RECORDS. 1.2 FOUNDATION CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH THE NATURE OF THE PROJECT, DWTING ON-SITE AND ADJACENT UTILITIES AND POTENTIAL HAZARDS AND TAKE WHATEVER PRECAUTIONS NECESSARY TO PROTECT THE OWNER FROM ANY DAMAGE OR LIABILITY. F REQUESTED BY THE OWNER, A VISUAL INSPECTION OF ANY NEARBY STRUCTURES SHALL BE PERFORMED BY A REGISTERED STRUCTURAL ENGINEER PRIOR TO FOUNDATION CONSTRUCTION. ALL EXISTING CRACKS, DAMAGES OR POTENTIALLY HAZARDOUS CONDITIONS SHALL BE NOTED, DOCUMENTED AND REPORTED PRIOR M PILE INSTALLATION. 2. TYPE OF PILES THE PILES SHALL BE AUGER -CAST TYPE PLES, AS LISTED BELOW. ALL PILES SHALL BE DRIVEN TO A PROPOSED DEPTH OF 45 FT. AS INDICATED N THE SOIL REPORT AND AS RECCOMENDED BY THE GEOTECHNICAL ENGINEER. TO DEVELOP THE SPECIFIED PILE CAPACITY NOMINAL DIAMETER INCHES GROUT STRENGTH AT 28 DAYS VERTICAL Ra G: 8U8 1 TO ACCOMMODATE CAMBERS WHEN IT BECOMES NECESSARY. COMPRESSION WSRON FULL LENGTH OF PI AT 28 DAYS MAX BF8-1B Z 18 4,000 PSI ELEMENT: STRENGTH: SUMP. 15 11 PRECAST CONCRETE SLAB UNITS SHALL HAVE MINIMAL CAMBER DIFFERENCES BETWEEN ALL CONC. BEAMS & SLABS 4,000 PSI 4 5' -IB' TO 6' -10- B BUS 1 ADJACENT UNITS AND BETWEEN A P.C. UNIT AND A CAST -IN -PUCE BEAM. FOOTNM 4,000 PSI 5 BFB-18 1 O ON FIRE RATINQ COMPLY WITH FIRE RATING REQUIREMENTS AS INDICATED HEREIN DR THE ARCHTECIURAL PLANS. IF FIRE RATING INFORMATION HAS NOT BEEN INCLUDED CONCRETE COLUMNS SEE COLUMN SCHEDULE REQUIREMENTS FOR SPECIAL EXPOSURE CONDITIONS (ACI-318. SECTION 4.2 TABLE 4.211: A TESTING LABORATORY SHALL BE ENGAGED TO TAKE SOIL CAl 4 FS. TEST AND REPORT THE CALCIUM AND SULFATE CONTENTS IN THE SOIL TO BE IN CONTACT WITH THE NEW CONCRETE F FOUND EXCEEDING ACI-318 MINIMUM ALLOWED, ALL CONCRETE PLACED IN CONTACT WITH THE GROUND EXPOSED TO SALT WATER, SEAWATER OR SPRAY FROM THESE SOURCES, SHALL HAVE A MAXIMUM WATER /CEMENT RATIO OF 0.40, IN ADDITION TO STRENGTH AND SLUMP REQUIREMENTS INDICATED ABOVE. NOTE: THE PILES SHALL BE DRIVEN INTO GROUND FIRST, BEFORE ANY COMPACTION WORK AND EXCAVATION FOR THE SHALLOW SPREAD FOOTING COORDINATE WORK AND SEQUENCE WITH THE GEOTECHNICAL ENGINEER. 1. SCOPE; 1.1 FURNISH ALL LABOR, MATERIALS, EQUIPMENT, INCIDENTALS, TRANSPORTATION, ERECTION/INSTALLATION AND SUPERVISION NECESSARY M COMPLETE ALL PILING AND RELATED WORK CALLED FOR ON THE PLANS OR HEREIN OR REASONABLY INFERABLE FROM EITHER OR 807H, INCLUDING BUT NOT LIMITED TO THE FOLLOWING: (A) AUG ERED-CAST GROUTED PILES. (B) ACCURATE LAYOUT AND INSTALLATION OF ALL PILES. (C) RECORDS. 1.2 FOUNDATION CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH THE NATURE OF THE PROJECT, DWTING ON-SITE AND ADJACENT UTILITIES AND POTENTIAL HAZARDS AND TAKE WHATEVER PRECAUTIONS NECESSARY TO PROTECT THE OWNER FROM ANY DAMAGE OR LIABILITY. F REQUESTED BY THE OWNER, A VISUAL INSPECTION OF ANY NEARBY STRUCTURES SHALL BE PERFORMED BY A REGISTERED STRUCTURAL ENGINEER PRIOR TO FOUNDATION CONSTRUCTION. ALL EXISTING CRACKS, DAMAGES OR POTENTIALLY HAZARDOUS CONDITIONS SHALL BE NOTED, DOCUMENTED AND REPORTED PRIOR M PILE INSTALLATION. 2. TYPE OF PILES THE PILES SHALL BE AUGER -CAST TYPE PLES, AS LISTED BELOW. ALL PILES SHALL BE DRIVEN TO A PROPOSED DEPTH OF 45 FT. AS INDICATED N THE SOIL REPORT AND AS RECCOMENDED BY THE GEOTECHNICAL ENGINEER. TO DEVELOP THE SPECIFIED PILE CAPACITY 3. VERTICAL REINFORCING AND TES FOR VERTICAL REINFORCING - SEE TABLE ABOVE TIES SHALL BE ROUND 03 TES, SPACED AT 12' O.C. THRUOUT THE ENTIRE LENGTH OF THE REINFORCING CAGE COMPRESSION REINFORCING CAGE TO EXTEND A MINIMUM OF 25 FT. INTP PILES AND PROJECT 20- INTO THE PILE- CAP. TENSION REBAR M BE CENTERED WITH PILE. FULL LENGTH OF PILE AND HOOKED INTO GRADE- BEAM/PILE -CAP, AS DETAILED. 4. DRERENCE: SUBMIT EVIDENCE THAT THE AUG;E RED GROUT PILE CONTRACTOR HAS BEEN ENGAGED IN THE SUCCESSFUL INSTALLATION OF A1GERED GROUT INJECTED PILES FOR AT LEAST 5 YEARS AND THAT HIS CRANE OPERATORS OR KEYMAN WHO GIVE DIRECTIONS M THE CRANE OPERATORS, HAVE AT LEAST 2 YEARS OF EXPERIENCE IN THE SUCCESSFUL INSTALLATION OF SAID PILE SYSTEM. 5. PILES NOT INSTALLED IN ACCORDANCE WITH ACCEPTED PROCEDURES SHALL BE REJECTED AND ADDITIONAL PILES SHALL BE INSTALLED AS DIRECTED BY FOUNDATION ENGINEER S. LOCATION N OF PIL FS• PILES SHALL BE LOCATED AS SHOWN ON PLANS OR AS DIRECTED BY ENGINEER PILE CENTERS SHALL BE MARKED ON 97E M AN ACCURACY OF (+ / -) ONE INCH. 7. ICLEBA = PILES SHALL BE INSTALLED WITHIN 3 INCHES OF PLAN POSITION. & INSPECTIONS:- THE OWNER WILL RETAIN THE SERVICES OF A STATE REGSTERED ENGINEER QUALIFIED AS A SOIL AND FOUNDATION ENGINEER. M CONDUCT FULL TIME OBSERVATIONS ('SPECIAL NSPEC110NS-) DURI NG TIE INSTALLATION (F THE PILES THE INSPECTOR ENGINEER WILL BE EMPLOYED M REPRESENT THE NTERIM OF THE OWNER AND AD THE CONTRACTOR WHEN NECESSARY. THE ENGINEER SHALL MAINTAIN A SEPARATE LOG OF EACH PILE AND ISSUE A PILE- STATEMENT AT THE COMPLETION OF THE PILE DRIVING WORK. AS M THE PILES COMPLIANCE WITH SIZE, LENGTH. FORCING AND REQUIRED LOAD CAPACITY. CONTACT ARCHITECT/ENGINEER FOR INFORMATION. BEFORE PROCEEDING WITH ENGINEERING AND SHOP DRAWING PREPARATION. 14. 'SPECIAL INISPEMW SERVICES ARE REQUIRED FOR THIS TYPE OF STRUCTURE N MIAMI­-DADS AND BROWARD COUNTIES, IN ADDITION TO THE INSPECTIONS PROVIDED BY THE LOCAL BUILDING DEPARTMENT. SEE 'SPECIAL INSPECTION REQUREMENTS' SECTION IN THESE GENERAL NOTES. CONTACT A/E FOR ANY REQUIRED INFORMATION AND /OR QUESTIONS 1. PRESTRESSED PRECAST JOISTS DEPTH AS INDICATED ON THE PLANS (U.O.N INDICATED ON THE SHOP DRAWINGS). SPACED AS INDICATED ON THE PLANS OR AS REQUIRED BY CALCULATIONS CAST -N -PLACE COMPOSITE SLAB SHALL BE A MINIMUM OF 4-3/4' THICK. REINFORCED WITH j4'S AT 12 INCIES ON CENTER EACH WAY (CENTERED WITH THE SLAB). SEE PLANS FOR ADDITIONAL REBARS OVER BEAMS AND AT CORNERS 1 COPE TOP OF JOISTS AT SUPPORTS TO PROVIDE CLEARANCE FOR BEAMS' TOP REINFORCEMENT AS REQUIRED. PROVIDE OTHER APPLICABLE PC JOISTS CONNECTORS AS MAY BE NECESSARY TO CLEAR CONGESTED REINFORCING OR OTHER CONDITIONS & IN THE EVENT THAT THE BOTTOM OF THE JOIST IS AT A DISTANCE OF 4' OR LESS FROM THE BOTTOM OF THE SUPPORTING BEAM, THE JOISTS DESIGNER SHALL PROVIDE A BOTTOM NOTCH AT EACH SUCH JOIST. (BOTTOM NOTCHED JOISTS MAY ALSO BE REQUIRED ELSEWHERE ON THE PLANS - SEE SECTIONS AND ENGINEERED SHOP DRAWINGS). 4. MINIMUM CONCRETE STRENGTH OF THE PRECAST JOISTS IS F'c - 5.000 PS AND THE CAST -N -PLACE SLAB F'c - 5,000 P.SL 5. MINIMUM BEARING OF THE JOIST ONTO THE SUPPORTING BEAMS IS 4'. 6. THE PROJECT REQUIRE 16' OR 24- MADE COMPOSITE PC BEAM SOFFITS WITH CASTNN -PUCE CONCRETE ON TOP - SEE BEAM SCHEDULE FOR CALCULATED ULTIMATE MOMENTS AND SHEAR (TO BE USED BY THE COMPOSITE PC BEAM DESIGNER). 7. PC COMPOSITE BEAM DESIGNER SHALL DESIGN THE PC SOFFIT FOR THE PROVIDED MOMENTS AND DESIGN THE STIRRUPS (CR TES) FOR A COMBINED SEAR AND TORSION (AS APPLICABLE). & SEE STRUCTURAL PUNS OR SCHEDULE FOR 'SHEAR - FRICTION' REINFORCING UNLESS OTHERWISE SPECIFIED, MINIMUM SHEAR - FRICTION REINFORCING SHALL BE NO LESS THAN (5)-#6'S (10' LONG STRAIGHT BARS OR 6' LONG WMW AT END COLUMNS). 9. REQUIRED SYSTEM FIRE RATING IS ONE (1) OR TWO (2) HOURS MINIMUM (UNLESS OTHERWISE NOTED) - SEE ARCHITECTURAL DOCUMENTS FOR ALL FIRE RATING REQUIREMENM NON- REINFORCED LOAD BEARING MASONRY WALLS: 1. HOLLOW LOAD - BEARING MASONRY UNITS SHALL CONFORM TO ASTM C -90. TYPE 4 REGULAR WEIGHT, WITH A MINIMUM DESIGN COMPRESSIVE STRENGTH ON NET AREA OF F'm -1,900 PSL CONSTRUCTION SHALL BE IN ACCORDANCE WITH LATEST ACI-530 SPECIFICATIONS 1 MORTAR SHALL CONFORM TO ASTM C -270, TYPE 'M' OR -5-. 3. LAY ALL MASONRY WITH FULL FACE HEAD JOINTS AND WITH FACE SHELL MORTAR BEDDING 4. CONCRETE IN TIE COLUMNS AND TIE BEAMS SHALL BE PLACED AGAINST N -PUCE MASONRY. 5. HORIZONTAL R13NFOMN PROVIDE GALVANIZED P9 GAGE WIRE, TRUSS TYPE, HORIZONTAL JOINT REINFORCING EVERY 2ND BLOCK COURSE (1' -4' O.C. VERTICALLY) LAPPED 7 -1/2- AND EXTENDED 4' INTO CONCRETE COLUMNS. PROVIDE SPECIAL HORIZONTAL REINFORCING AT i AND -L- INTERSECTION. PROVIDE 'DOVE -TAIL' ANCHORS AT 16. O.C. VERTICALLY FOR ALL MASONRY PLACED ADJACENT TO ALREADY IN PUCE COLUMNS. 6. CONCRETE TIE COLUMNS ARE REQUIRED AT 16 FT. ON CENTERS MAXIMUM (SMALLER SPACING MAY BE REQUIRED M LIMIT THE MASONRY PANEL AREA TO 240 SQ.FT.) OR AS REQUIRED BY DESIGN), AT EVERY CORNER OR CHANGE OF WALL DIRECTION, ON EACH SIDE OF OPENINGS LARGER THAN 8 FT., ADJACENT M ANY CORNER OPENING URGER THAN 4 FT., AT GABLE AND SHED END CORNERS AND AT FREE STANDING OF WALLS EXCEEDING 2 FL. ALL TIE COLUMNS AND COLUMNS SHALL BE EXTENDED TO THE TOP OF THE ROOF PARAPET WALL (UNLESS OTHERWISE INDICATED ON THE PLANS OR DETAILS). 7. N THE EVENT OF DISCREPANCY BETWEEN THESE REQUIREMENTS AND THE COLUMNS INDICATED ON THE PAWS, THE MORE STRINGENT REQUIREMENT OR CONDITION SHALL BE USED. & ANY MASONRY OPENINGS BETWEEN 3 AND 8 FT. N WIDTH SHALL HAVE ONE j5 VERTICAL REBAR ON EACH SIDE, PLACED N BLOCK CELL FILLED WITH CONCRETE. THESE REBARS SHALL BE HOOKED AT THE FOUNDATION AND AT THE TIE BEAM AND LAPPED 30' MINIMUM. 9. SEE SECTION 'CONCRETE AND RENFORCING' FOR MINIMUM TIE BEAMS, WHERE OTHER BEAMS ARE NOT OTHERWISE INDICATED ON PUNS. 10. IN COMPLIANCE WITH 'OSHA' REQUIREMENTS (29 CFR 1925.706(b)) WALLS HIGHER THAN 8 FT. SHALL BE LATERALLY BRACED DURING CONSTRUCTION. BRACING SHALL REMAIN N PLACE TILL THE ROOF AND /OR FLOOR STRUCTURES HAVE BEEN SECURED TO PROVIDE THE REQUIRED PERMANENT BRACING CONTRACTOR SHALL PROVIDE LATERAL BRACING SHOP DRAWINGS OR DATA SHEETS. DESIGNED, SIGNED AND SEALED BY A FLORIDA REGSTERED STRUCTURAL ENGINEER LINTELS OVER MASONRY WALL OPENINGS 1. THE CONTRACTOR SHALL PROVIDE PRECAST CONCRETE OR CAST -IN -PLACE LINTELS AT THE HEADS OF ALL OPENINGS IN MASONRY WALLS NOT EXCEEDING SEVEN (7) FEET IN WIDTH WHERE BEAMS/IINTELS HAVE NOT BEEN OTHERWISE SPECIFIED ON PLANS/1*7AIS OR SCHEDULED. 2. THE LINTEL GUIDE SPECIFIED HERE IS FOR LINTELS SUBJECTED TO DOWNWARD (GRAVITY) ROOF AND FLOOR LOADS, EVENLY DISTRIBUTED OVER THE ENTIRE SPAN OF THE LINTEL SPECIAL LOADING CONDITIONS, SUCH AS WIND NET UPLIFT OR CONCENTRATED LOADS, AND LINTEL SPANS EXCEEDING THE INDICATED ABOVE, ARE NOT COVERED BY THESE NOTES (SEE PLANS AND SCHEDULES FOR SPECIFIC BEAMS AT THESE LOCATIONS). 3 CONTRACTOR SHALL NOTIF Y THE A/E OF HS WOKE OF CAST N PLACE LINTELS, PRECAST LINTELS OR A COMBINATION THEREOF, TO BE USED BY HM N THIS PROJECT. 4. LNTELS BEARING ONTO CAST -IN -PLACE CONCRETE COLUMNS (ON ONE OR BOTH ENDS, SHALL BE CAST-IN-PLACE TYPE (NOT PRECAST). 5. ALL LINTELS SHALL BE BEARING AT LEAST 8' ONTO THE SUPPORTS ON EACH SIDE OF THE OPENING. S. LINTEL OPTION MIT: LINTEL CAST TOGETHER WITH THE BEAM OR TIE BEAM. LINTEL MAY BE CAST INTEGRAL WITH THE STRUCTURAL. OR TIE BEAM WHEN HEAD OF THE OPENING IS 24 INCHES OR LESS BELOW. CONTINUE BEAM'S TYPICAL TOP AND BOTTOM REBARS THROUGH AND ADD 2 -05 BOTTOM BARS AT DROPS AND 3-P3 STIRRUPS AT 6- O.C. EACH END OVER OPENING:. SHOULD THE CONTRACTOR WISH M CAST DEEPER BEAM DROPS (USED FOR LINTELS) HE SHOULD CONSULT CHITIN THE A/E REGARDING ADDITIONAL (OR DIFFERENT) VERTICAL AND HORIZONTAL REINFORCEMENT. 7. LINTEL OPTION AM CAST -N -PLACE LINTELS (SEPARATED FROM TIE BE ABOVE). CAST -IN -PUCE LINTELS SHALL BE A MINIMUM GF 8'x12' CONCRETE REINFORCED WITH 2 -#5 TOP AND BOTTOM, AND 3-J3 STIRRUPS AT 4. O.C. EACH END, BALANCE AT 12. O.C.. SEE 'CONCRETE' SECTION FOR ARCHED BOTTOM CAST -IN -PUCE CONCRETE LINTEL NOTES. & LINTEL OPTION JU PRECAST U - LINTELS LINTEL INFORMATION PROVIDED HERE IS BASED ON THE LINTELS PRODUCED BY 'CASTCRETE' AND ON THEIR ALLOWABLE LOADING TABLE CONTRACTOR M SUBMIT LINTEL SPECIFICATIONS AND LOADING DATA F HE IS USING LINTELS MANUFACTURED BY OTHER THAN •CASTCREFE'. ALL LINTEL BOTTOMS SHALL BE r PRECAST 'U' SHAPED. FILLED SCUD WITH CONCRETE LINTELS THAT REQUIRE REINFORCING WITH A HORIZONTAL Fi REBAR ARE SPECIALLY MARKED. 9. L NTH! j=B n c• BASED ON - CAST - CRETE' DATA - NOA j03- OSM05) CLEAR T NOMINAL DIAMETER INCHES GROUT STRENGTH AT 28 DAYS VERTICAL Ra G: 8U8 1 APACITY: COMPRESSION WSRON FULL LENGTH OF PI COMP. TONS TENSION TONS BF8-1B Z 18 4,000 PSI (6) - P7 I (1) - 09 45 15 1,105 3. VERTICAL REINFORCING AND TES FOR VERTICAL REINFORCING - SEE TABLE ABOVE TIES SHALL BE ROUND 03 TES, SPACED AT 12' O.C. THRUOUT THE ENTIRE LENGTH OF THE REINFORCING CAGE COMPRESSION REINFORCING CAGE TO EXTEND A MINIMUM OF 25 FT. INTP PILES AND PROJECT 20- INTO THE PILE- CAP. TENSION REBAR M BE CENTERED WITH PILE. FULL LENGTH OF PILE AND HOOKED INTO GRADE- BEAM/PILE -CAP, AS DETAILED. 4. DRERENCE: SUBMIT EVIDENCE THAT THE AUG;E RED GROUT PILE CONTRACTOR HAS BEEN ENGAGED IN THE SUCCESSFUL INSTALLATION OF A1GERED GROUT INJECTED PILES FOR AT LEAST 5 YEARS AND THAT HIS CRANE OPERATORS OR KEYMAN WHO GIVE DIRECTIONS M THE CRANE OPERATORS, HAVE AT LEAST 2 YEARS OF EXPERIENCE IN THE SUCCESSFUL INSTALLATION OF SAID PILE SYSTEM. 5. PILES NOT INSTALLED IN ACCORDANCE WITH ACCEPTED PROCEDURES SHALL BE REJECTED AND ADDITIONAL PILES SHALL BE INSTALLED AS DIRECTED BY FOUNDATION ENGINEER S. LOCATION N OF PIL FS• PILES SHALL BE LOCATED AS SHOWN ON PLANS OR AS DIRECTED BY ENGINEER PILE CENTERS SHALL BE MARKED ON 97E M AN ACCURACY OF (+ / -) ONE INCH. 7. ICLEBA = PILES SHALL BE INSTALLED WITHIN 3 INCHES OF PLAN POSITION. & INSPECTIONS:- THE OWNER WILL RETAIN THE SERVICES OF A STATE REGSTERED ENGINEER QUALIFIED AS A SOIL AND FOUNDATION ENGINEER. M CONDUCT FULL TIME OBSERVATIONS ('SPECIAL NSPEC110NS-) DURI NG TIE INSTALLATION (F THE PILES THE INSPECTOR ENGINEER WILL BE EMPLOYED M REPRESENT THE NTERIM OF THE OWNER AND AD THE CONTRACTOR WHEN NECESSARY. THE ENGINEER SHALL MAINTAIN A SEPARATE LOG OF EACH PILE AND ISSUE A PILE- STATEMENT AT THE COMPLETION OF THE PILE DRIVING WORK. AS M THE PILES COMPLIANCE WITH SIZE, LENGTH. FORCING AND REQUIRED LOAD CAPACITY. CONTACT ARCHITECT/ENGINEER FOR INFORMATION. BEFORE PROCEEDING WITH ENGINEERING AND SHOP DRAWING PREPARATION. 14. 'SPECIAL INISPEMW SERVICES ARE REQUIRED FOR THIS TYPE OF STRUCTURE N MIAMI­-DADS AND BROWARD COUNTIES, IN ADDITION TO THE INSPECTIONS PROVIDED BY THE LOCAL BUILDING DEPARTMENT. SEE 'SPECIAL INSPECTION REQUREMENTS' SECTION IN THESE GENERAL NOTES. CONTACT A/E FOR ANY REQUIRED INFORMATION AND /OR QUESTIONS 1. PRESTRESSED PRECAST JOISTS DEPTH AS INDICATED ON THE PLANS (U.O.N INDICATED ON THE SHOP DRAWINGS). SPACED AS INDICATED ON THE PLANS OR AS REQUIRED BY CALCULATIONS CAST -N -PLACE COMPOSITE SLAB SHALL BE A MINIMUM OF 4-3/4' THICK. REINFORCED WITH j4'S AT 12 INCIES ON CENTER EACH WAY (CENTERED WITH THE SLAB). SEE PLANS FOR ADDITIONAL REBARS OVER BEAMS AND AT CORNERS 1 COPE TOP OF JOISTS AT SUPPORTS TO PROVIDE CLEARANCE FOR BEAMS' TOP REINFORCEMENT AS REQUIRED. PROVIDE OTHER APPLICABLE PC JOISTS CONNECTORS AS MAY BE NECESSARY TO CLEAR CONGESTED REINFORCING OR OTHER CONDITIONS & IN THE EVENT THAT THE BOTTOM OF THE JOIST IS AT A DISTANCE OF 4' OR LESS FROM THE BOTTOM OF THE SUPPORTING BEAM, THE JOISTS DESIGNER SHALL PROVIDE A BOTTOM NOTCH AT EACH SUCH JOIST. (BOTTOM NOTCHED JOISTS MAY ALSO BE REQUIRED ELSEWHERE ON THE PLANS - SEE SECTIONS AND ENGINEERED SHOP DRAWINGS). 4. MINIMUM CONCRETE STRENGTH OF THE PRECAST JOISTS IS F'c - 5.000 PS AND THE CAST -N -PLACE SLAB F'c - 5,000 P.SL 5. MINIMUM BEARING OF THE JOIST ONTO THE SUPPORTING BEAMS IS 4'. 6. THE PROJECT REQUIRE 16' OR 24- MADE COMPOSITE PC BEAM SOFFITS WITH CASTNN -PUCE CONCRETE ON TOP - SEE BEAM SCHEDULE FOR CALCULATED ULTIMATE MOMENTS AND SHEAR (TO BE USED BY THE COMPOSITE PC BEAM DESIGNER). 7. PC COMPOSITE BEAM DESIGNER SHALL DESIGN THE PC SOFFIT FOR THE PROVIDED MOMENTS AND DESIGN THE STIRRUPS (CR TES) FOR A COMBINED SEAR AND TORSION (AS APPLICABLE). & SEE STRUCTURAL PUNS OR SCHEDULE FOR 'SHEAR - FRICTION' REINFORCING UNLESS OTHERWISE SPECIFIED, MINIMUM SHEAR - FRICTION REINFORCING SHALL BE NO LESS THAN (5)-#6'S (10' LONG STRAIGHT BARS OR 6' LONG WMW AT END COLUMNS). 9. REQUIRED SYSTEM FIRE RATING IS ONE (1) OR TWO (2) HOURS MINIMUM (UNLESS OTHERWISE NOTED) - SEE ARCHITECTURAL DOCUMENTS FOR ALL FIRE RATING REQUIREMENM NON- REINFORCED LOAD BEARING MASONRY WALLS: 1. HOLLOW LOAD - BEARING MASONRY UNITS SHALL CONFORM TO ASTM C -90. TYPE 4 REGULAR WEIGHT, WITH A MINIMUM DESIGN COMPRESSIVE STRENGTH ON NET AREA OF F'm -1,900 PSL CONSTRUCTION SHALL BE IN ACCORDANCE WITH LATEST ACI-530 SPECIFICATIONS 1 MORTAR SHALL CONFORM TO ASTM C -270, TYPE 'M' OR -5-. 3. LAY ALL MASONRY WITH FULL FACE HEAD JOINTS AND WITH FACE SHELL MORTAR BEDDING 4. CONCRETE IN TIE COLUMNS AND TIE BEAMS SHALL BE PLACED AGAINST N -PUCE MASONRY. 5. HORIZONTAL R13NFOMN PROVIDE GALVANIZED P9 GAGE WIRE, TRUSS TYPE, HORIZONTAL JOINT REINFORCING EVERY 2ND BLOCK COURSE (1' -4' O.C. VERTICALLY) LAPPED 7 -1/2- AND EXTENDED 4' INTO CONCRETE COLUMNS. PROVIDE SPECIAL HORIZONTAL REINFORCING AT i AND -L- INTERSECTION. PROVIDE 'DOVE -TAIL' ANCHORS AT 16. O.C. VERTICALLY FOR ALL MASONRY PLACED ADJACENT TO ALREADY IN PUCE COLUMNS. 6. CONCRETE TIE COLUMNS ARE REQUIRED AT 16 FT. ON CENTERS MAXIMUM (SMALLER SPACING MAY BE REQUIRED M LIMIT THE MASONRY PANEL AREA TO 240 SQ.FT.) OR AS REQUIRED BY DESIGN), AT EVERY CORNER OR CHANGE OF WALL DIRECTION, ON EACH SIDE OF OPENINGS LARGER THAN 8 FT., ADJACENT M ANY CORNER OPENING URGER THAN 4 FT., AT GABLE AND SHED END CORNERS AND AT FREE STANDING OF WALLS EXCEEDING 2 FL. ALL TIE COLUMNS AND COLUMNS SHALL BE EXTENDED TO THE TOP OF THE ROOF PARAPET WALL (UNLESS OTHERWISE INDICATED ON THE PLANS OR DETAILS). 7. N THE EVENT OF DISCREPANCY BETWEEN THESE REQUIREMENTS AND THE COLUMNS INDICATED ON THE PAWS, THE MORE STRINGENT REQUIREMENT OR CONDITION SHALL BE USED. & ANY MASONRY OPENINGS BETWEEN 3 AND 8 FT. N WIDTH SHALL HAVE ONE j5 VERTICAL REBAR ON EACH SIDE, PLACED N BLOCK CELL FILLED WITH CONCRETE. THESE REBARS SHALL BE HOOKED AT THE FOUNDATION AND AT THE TIE BEAM AND LAPPED 30' MINIMUM. 9. SEE SECTION 'CONCRETE AND RENFORCING' FOR MINIMUM TIE BEAMS, WHERE OTHER BEAMS ARE NOT OTHERWISE INDICATED ON PUNS. 10. IN COMPLIANCE WITH 'OSHA' REQUIREMENTS (29 CFR 1925.706(b)) WALLS HIGHER THAN 8 FT. SHALL BE LATERALLY BRACED DURING CONSTRUCTION. BRACING SHALL REMAIN N PLACE TILL THE ROOF AND /OR FLOOR STRUCTURES HAVE BEEN SECURED TO PROVIDE THE REQUIRED PERMANENT BRACING CONTRACTOR SHALL PROVIDE LATERAL BRACING SHOP DRAWINGS OR DATA SHEETS. DESIGNED, SIGNED AND SEALED BY A FLORIDA REGSTERED STRUCTURAL ENGINEER LINTELS OVER MASONRY WALL OPENINGS 1. THE CONTRACTOR SHALL PROVIDE PRECAST CONCRETE OR CAST -IN -PLACE LINTELS AT THE HEADS OF ALL OPENINGS IN MASONRY WALLS NOT EXCEEDING SEVEN (7) FEET IN WIDTH WHERE BEAMS/IINTELS HAVE NOT BEEN OTHERWISE SPECIFIED ON PLANS/1*7AIS OR SCHEDULED. 2. THE LINTEL GUIDE SPECIFIED HERE IS FOR LINTELS SUBJECTED TO DOWNWARD (GRAVITY) ROOF AND FLOOR LOADS, EVENLY DISTRIBUTED OVER THE ENTIRE SPAN OF THE LINTEL SPECIAL LOADING CONDITIONS, SUCH AS WIND NET UPLIFT OR CONCENTRATED LOADS, AND LINTEL SPANS EXCEEDING THE INDICATED ABOVE, ARE NOT COVERED BY THESE NOTES (SEE PLANS AND SCHEDULES FOR SPECIFIC BEAMS AT THESE LOCATIONS). 3 CONTRACTOR SHALL NOTIF Y THE A/E OF HS WOKE OF CAST N PLACE LINTELS, PRECAST LINTELS OR A COMBINATION THEREOF, TO BE USED BY HM N THIS PROJECT. 4. LNTELS BEARING ONTO CAST -IN -PLACE CONCRETE COLUMNS (ON ONE OR BOTH ENDS, SHALL BE CAST-IN-PLACE TYPE (NOT PRECAST). 5. ALL LINTELS SHALL BE BEARING AT LEAST 8' ONTO THE SUPPORTS ON EACH SIDE OF THE OPENING. S. LINTEL OPTION MIT: LINTEL CAST TOGETHER WITH THE BEAM OR TIE BEAM. LINTEL MAY BE CAST INTEGRAL WITH THE STRUCTURAL. OR TIE BEAM WHEN HEAD OF THE OPENING IS 24 INCHES OR LESS BELOW. CONTINUE BEAM'S TYPICAL TOP AND BOTTOM REBARS THROUGH AND ADD 2 -05 BOTTOM BARS AT DROPS AND 3-P3 STIRRUPS AT 6- O.C. EACH END OVER OPENING:. SHOULD THE CONTRACTOR WISH M CAST DEEPER BEAM DROPS (USED FOR LINTELS) HE SHOULD CONSULT CHITIN THE A/E REGARDING ADDITIONAL (OR DIFFERENT) VERTICAL AND HORIZONTAL REINFORCEMENT. 7. LINTEL OPTION AM CAST -N -PLACE LINTELS (SEPARATED FROM TIE BE ABOVE). CAST -IN -PUCE LINTELS SHALL BE A MINIMUM GF 8'x12' CONCRETE REINFORCED WITH 2 -#5 TOP AND BOTTOM, AND 3-J3 STIRRUPS AT 4. O.C. EACH END, BALANCE AT 12. O.C.. SEE 'CONCRETE' SECTION FOR ARCHED BOTTOM CAST -IN -PUCE CONCRETE LINTEL NOTES. & LINTEL OPTION JU PRECAST U - LINTELS LINTEL INFORMATION PROVIDED HERE IS BASED ON THE LINTELS PRODUCED BY 'CASTCRETE' AND ON THEIR ALLOWABLE LOADING TABLE CONTRACTOR M SUBMIT LINTEL SPECIFICATIONS AND LOADING DATA F HE IS USING LINTELS MANUFACTURED BY OTHER THAN •CASTCREFE'. ALL LINTEL BOTTOMS SHALL BE r PRECAST 'U' SHAPED. FILLED SCUD WITH CONCRETE LINTELS THAT REQUIRE REINFORCING WITH A HORIZONTAL Fi REBAR ARE SPECIALLY MARKED. 9. L NTH! j=B n c• BASED ON - CAST - CRETE' DATA - NOA j03- OSM05) CLEAR T To G GRAVITY LOAD UP TO 3 -1 8 8U8 1 1,599 6F8-OB 1 1,969 BF8-1B Z Z189 4' -0' M 5' -6' 1 1,062 BFS-08 1 1,105 8F8-1B I I 1,451 5' -IB' TO 6' -10- B BUS 1 743 8F8-OB 1 1 7 BFB-18 1 1 011 STRUC7URAL_STEM (SHOP DRAWINGS REQUIRED) 1. ALL STRUCTURAL STEEL TO BE DOMESTIC A.&T.M. A -36 (Fy-36 K.SL) AND DESIGNED IN ACCORDANCE WITH A.LSC. - SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BULDNW AND THE A.LS.C. CODE OF STANDARD PRACTICE. 1 STEEL TUBES M BE DOMESTIC STEEL CONFORMING M A.S.T.M. A -500 GRADE B (Fy-46 K &L). 3. SEE ARCHITECTURAL DOCUMENTS FOR FIRE RATING REQUIREMENTS 4. ALL COLUMN BASE AND CAP PLATES SHALL BE 3/4' THICK (UNLESS OTHERWISE NOTED WIDTH AND LENGTH AS REQUIRED FOR PROPER BOLTING AND AS INDICATED ON THE PLANS AND DETAILS. 5. ALL STEEL SHALL BE SHOP PANTED WITH AN APPROVED PRIME COAT. STEEL EXPOSED TO THE ELEMENTS OR ANY STEEL N STRUCTURES CLOSE M THE OCEAN, SHALL BE EPDXY PANTED. SEE ARCHITECTURAL DRAWNM FOR FINISH PANT INFORMATION. ALL DAMAGES TO THE PANT ON STE OR WRING DELIVERY (INCLUDING DRILLING AND WILDING OPERATIONS) SHALL BE FIELD TOUCHED -UP WITH THE SAME SPECIFIED RUSTPROOFING PANT. & ALL WELDING TO BE N ACCORDANCE WITH A.W.S. 'STRUCTURAL WIELDING CODE - STEw. ALL WELDERS TO BE A.W.S CERTIFIED (CER11nCATION TO BE AVAILABLE ON -SITE DURING WELDING INSPECTION). ALL WELDS TO BE FILLET OR PENETRATION WELDS (THICKNESS M BE IN ACCORDANCE WITH BASE METAL THICKNESS). USE MINIMUM E70XX ELECTRODES. CLEAN AND RUSTPROOF ALL FELD WELDS WITH HEAVY DUTY RUSTPROOFNG PANT. 7. ALL CONNECTIONS TO BE SHOP WELDED AND /CR FIELD WELDED. UNLESS OTHERWISE SPECIFICALLY INDICATED ON PLANS AND DETAILS, ALL WELDS SHALL BE CONSIDERED FULL WEDS (ALONG THE CONTACT LENGTHS OF THE CONNECTING STEEL ELEMENTS). BOLTED CONNECTIONS MAY BE USED AS DIRECTED. WHERE SPECIFIED ON PLANS AND DETAILS, BOLTS SHALL BE A325 STEEL (U.O.N.). & ALL ANCHOR J -BOLTS (WHERE SPECIFIED FOR COLUMN AND BEAM CONNECTIONS INTO CONCRETE) SHALL BE GALVANIZED AND HAVE A 4- MINIMUM HOOKED END (U.O.N.). 9. UNLESS OTHERWISE DETAILED IN THESE DRAWINGS, SPLICE TYPES AND LOCATIONS SHALL BE INDICATED ON THE SHOP DRAWINGS M BE REVIEWED BY THE ARCHITECT/ ENGINEER. 10. STEEL BEARING ON STEEL M BE WELDED THERETO. 11. STEEL SHOP DRAWINGS SHALL DETAL ALL STEEL ELEMENTS AND CONNECTIONS. AS SPECIFIED ON THE RECORD- DRAWINGS SHOULD THE SIM SUPPLER DECIDE M ALTER ANY MEMBER SZED AND /OR CONNECTIONS. SUCH ALTERATION SHALL REQUIRE THE DESIGN AND SEAL OF THE STEEL SUPPLER -S DELEGATED ENGINEER (WHO SHALL PROVIDE SIGNED AND SEALED SHOP DRAWINGS AND CALCULATIONS FOR THE MODIFIED ITEMS ONLY). 11 *SPECIAL dMKC71ON SERVICES ARE REQUIRED FOR THIS TYPE OF STRUCTURE IN MIAMI -DADS AND BROWARD COUNTIES, N ADDITION M THE INSPECTIONS PROVIDED BY THE LOCAL BUILDING DEPARTMENT. SEE 'SPECIAL INSPECTION REQUIREMENTS' SECTION IN THESE GENERA. NOTES. CONTACT A/E FOR ANY REQUIRED INFORMATION AND/01? QUESTIONS. STRUCTURAL DESIGN CRITERIA: 1. THE DESIGN COMPILES WITH THE REQUIREMENTS OF THE FOLLOWING CODES} MIAMI -DADS AND BROWARD COUNTIES ONLY .V.H.7.1: 2010 FLORIDA BUILDING CODE - BUILDING FLORIDA BUILDING CODE - CURRENT SUPPLEMENTS AND AMENDMENTS ARE INCLUDED WITH ALL THE ABOVE. ALL CODES, SPECIFICATIONS AND OTHER APPUCABLE REFERENCES, SHALL BE OF THE EDITION INDICATED IN THE ABOVE REFERENCED CODE 1 DESIGN GRAVITY LOADS SUPERIMPOSED LOADS U S E LIVE DEAD ROOF 30 25 OFFICE FLOOR 50 20 PARKING 50 -- STARS, EGRESS, MECHANICAL EQUIP. 100 STRUCTURAL DESIGN CRITERIA - WIND 1. MIND DESIGN CRITERIA: WIND DESIGN CODE ASCE -7(10) BUILDING CATEGORY: 2 WIND VELOCITY: 175 MPH (LRFD) WOMM BUILDING: EXPOSURE CATEGORY: -C' (GCPI - ±008) IMPORTANCE FACTOR: 1.00 Kd - 0.85 MEAN ROOF HEIGHT: 50 FT. MAX (FLAT ROOF) CORNER DISTANCE 'a' - 5.00 FT. 2. WIND FORCE SUMMARY (A.SD - 0.60 x LRFD) 2A. MAIM WIND FORCE RESISTING SYSTEM ROOF (TABLE 27.6 -2F. ZONE 3: -58.5 PSF ZONE 4. -41.5 PSF ZONE 5: -34.0 PSF WALL GTABLE 27.8-11 WINDWARD + LEEWARD: 48.7 PSF LEEWARD: -17.4 PSF WINDWARD: -312 PSF WIND ON PARAPET (02X,§_-a- 78.4 PSF 28. COMPONENTS & CLADDING: (CHAPTER 30 - PART 2) BUILDING ZONE ZONE ZONE ZONE ZONE FLAT ROOF 47.3 56.0 ROOFING FU -51.6 86.6 OVERHANG 74.4 WALL +43.1 -47.0-54.6 PARAPET WALL I 1312 GLASS WINDOWS 10 SOFT) 47.2 -51.2 0 It EXT. METAL CLADDING PANELS (SEE NOTE j4) 3. THE WIND LOADS INDICATED N THE TABLE ABOVE HAVE BEEN CALCULATED BASED ON THE 'MAN - FRAME' DESIGN FACTORS OF THE 'ASCE -7'. STRUCTURAL ELEMONTS EXPOSED TO WIND HAVE BEEN DESIGNED BASED ON 'COMPONENTS & CLADDING' FACTORS OF THE CODE 4. WIND LOAD CALCULATIONS ON DOORS 4.1 N THE ABSENCE OF SPECIFIC INFORMATION REGARDING THE WINDOWS/DOORS (AT THE TIME OF PREPARATION OF THESE PLANS), WIND LOADS HAVE BEEN CALCULATED BASED ON THE TRIBUTARY AREA USED FOR EACH TYPE AS INDICATED, PRODUCING THE MAXIMUM POSSIBLE CALCULATED WIND PRESSUE/SUCTION (UNLESS OTHERWISE PERMITTED - SEE CONDITION 'B-). 4.2 THE ABOVE LISTED WIND PRESSURE/SUCTION ASSUME THAT THE SPECIFIC DOOR/ WINDOW PRODUCT APPROVAL DOCUMENTS INDICATE THAT THE TESTED WIND PRESSURE/ SUCTION CAPACITIES HAVE NOT BEEN INCREASED BY A FACTOR OF J. THE CALCULATED PRESSURE/SUCTION VALUES ASSUME Kd - 0.85 CONDITION 'A': IN THE EVENT THAT THE SPECIFIC DOOR/WINDOW PRODUCT APPROVAL DOCUMENTS INDICATE THAT THE TESTED WIND PRESSURE/SUCTION CAPACITIES HAVE BEEN INIREAM BY A FACTOR OF L11 THE CALCULATED PRESSURE/SUCTION VALES SHOWN N THE TABLE ABOVE SHALL BE MULTIPLIED BY 1.176 (TO ACCOUNT FOR Kd 1.001 CONDITION %'- THE EVENT THAT THE OWNER /CONTRACTOR/NA LIF. CAN SUBMIT DATA IDENTIFYING THE TRIBUTARY AREA OF THE ELEMENT THAT CONTROLLED THE TESTED CAPACITY OF THE DOOR/WIDOW. THE ENGINEER -OF- RECORD MAY ADJUST THE ABOVE LOADS DESIGNED USING SAID TRIBUTARY AREA. WIND ZONES FOR ROOF AND WALLS 'a- - 5' -0- (CORNER DISTANCE) ZONE (PERIMETER) 3 2 ZONE 2 (FIELD) 3 2 3 I... TYP. '�h.�J o j GDK JOB#:K dA= G.D. Klieger, Inc. Consulting Structural Engineers 0 1909 Harrison St., Suite 204 EO Hollywood, Florida 33020 -5017 Phone: (954) 923 -2111 EH 0004821 EMAIL- gkUegerOatt.net _XMW s7iLea - - I 1- I i E_ -- I i - I - V'0116 i ' I i' I I S P I I 1----.----,---,"--�11----,---,-"""""lI - - ----- _,"'i I 1 Design Services For The Built Environment ■ Atlanta Birmingham Cincinnati Columbus Dallas Fort Lauderdale Knoxville Jackson Jacksonville Louisville Memphis Nashville Richmond Tampa E G R E S H A M S M I T A N D P A R T N E R S 6030 Hollywood Blvd. Suite 210 Hollywood, Florida 33024 954.981.9100 FIRM'S FLORIDA CERT. No. AAP000034/CA3806 1826000797/LC26000381 G.D. Klieger, Inc. Consulting Structural Engineers 1909 Harrison St., Suite 204 Hollywood, Florida 33020 -5017 Phone: (954) 923 -2111 EMAIL: gklieger ®att.net 4) 14 � •_rrN w M �_ W Q .. ." 0 Lu � O lu � � t1 EL .� �d r� 4) � r- � � "� C1 111 F- w GERSHON KLIEGER, PE (FL. PE #36109) t , ,- . .1 r f' DEC 19 2012 REVISION No. - Date -- Revision I I I I 1 I ............. .... I — —........ ........................ .1......... i I ....... i ................._............ ...._.. ", I I i i ............................... ............................... .................................. ............................... I � I i GENERAL NOTES S=11 [00 F Ids E : K- 12059 -S -11 .dwg PdT®.:[`: y : 29080.00 -j E :: 12/14/2012 STRUCTURAL DESIGN CRITERIA - WIND 1. MIND DESIGN CRITERIA: WIND DESIGN CODE ASCE -7(10) BUILDING CATEGORY: 2 WIND VELOCITY: 175 MPH (LRFD) WOMM BUILDING: EXPOSURE CATEGORY: -C' (GCPI - ±008) IMPORTANCE FACTOR: 1.00 Kd - 0.85 MEAN ROOF HEIGHT: 50 FT. MAX (FLAT ROOF) CORNER DISTANCE 'a' - 5.00 FT. 2. WIND FORCE SUMMARY (A.SD - 0.60 x LRFD) 2A. MAIM WIND FORCE RESISTING SYSTEM ROOF (TABLE 27.6 -2F. ZONE 3: -58.5 PSF ZONE 4. -41.5 PSF ZONE 5: -34.0 PSF WALL GTABLE 27.8-11 WINDWARD + LEEWARD: 48.7 PSF LEEWARD: -17.4 PSF WINDWARD: -312 PSF WIND ON PARAPET (02X,§_-a- 78.4 PSF 28. COMPONENTS & CLADDING: (CHAPTER 30 - PART 2) BUILDING ZONE ZONE ZONE ZONE ZONE FLAT ROOF 47.3 56.0 ROOFING FU -51.6 86.6 OVERHANG 74.4 WALL +43.1 -47.0-54.6 PARAPET WALL I 1312 GLASS WINDOWS 10 SOFT) 47.2 -51.2 0 It EXT. METAL CLADDING PANELS (SEE NOTE j4) 3. THE WIND LOADS INDICATED N THE TABLE ABOVE HAVE BEEN CALCULATED BASED ON THE 'MAN - FRAME' DESIGN FACTORS OF THE 'ASCE -7'. STRUCTURAL ELEMONTS EXPOSED TO WIND HAVE BEEN DESIGNED BASED ON 'COMPONENTS & CLADDING' FACTORS OF THE CODE 4. WIND LOAD CALCULATIONS ON DOORS 4.1 N THE ABSENCE OF SPECIFIC INFORMATION REGARDING THE WINDOWS/DOORS (AT THE TIME OF PREPARATION OF THESE PLANS), WIND LOADS HAVE BEEN CALCULATED BASED ON THE TRIBUTARY AREA USED FOR EACH TYPE AS INDICATED, PRODUCING THE MAXIMUM POSSIBLE CALCULATED WIND PRESSUE/SUCTION (UNLESS OTHERWISE PERMITTED - SEE CONDITION 'B-). 4.2 THE ABOVE LISTED WIND PRESSURE/SUCTION ASSUME THAT THE SPECIFIC DOOR/ WINDOW PRODUCT APPROVAL DOCUMENTS INDICATE THAT THE TESTED WIND PRESSURE/ SUCTION CAPACITIES HAVE NOT BEEN INCREASED BY A FACTOR OF J. THE CALCULATED PRESSURE/SUCTION VALUES ASSUME Kd - 0.85 CONDITION 'A': IN THE EVENT THAT THE SPECIFIC DOOR/WINDOW PRODUCT APPROVAL DOCUMENTS INDICATE THAT THE TESTED WIND PRESSURE/SUCTION CAPACITIES HAVE BEEN INIREAM BY A FACTOR OF L11 THE CALCULATED PRESSURE/SUCTION VALES SHOWN N THE TABLE ABOVE SHALL BE MULTIPLIED BY 1.176 (TO ACCOUNT FOR Kd 1.001 CONDITION %'- THE EVENT THAT THE OWNER /CONTRACTOR/NA LIF. CAN SUBMIT DATA IDENTIFYING THE TRIBUTARY AREA OF THE ELEMENT THAT CONTROLLED THE TESTED CAPACITY OF THE DOOR/WIDOW. THE ENGINEER -OF- RECORD MAY ADJUST THE ABOVE LOADS DESIGNED USING SAID TRIBUTARY AREA. WIND ZONES FOR ROOF AND WALLS 'a- - 5' -0- (CORNER DISTANCE) ZONE (PERIMETER) 3 2 ZONE 2 (FIELD) 3 2 3 I... TYP. '�h.�J o j GDK JOB#:K dA= G.D. Klieger, Inc. Consulting Structural Engineers 0 1909 Harrison St., Suite 204 EO Hollywood, Florida 33020 -5017 Phone: (954) 923 -2111 EH 0004821 EMAIL- gkUegerOatt.net _XMW s7iLea - - I 1- I i E_ -- I i - I - V'0116 i ' I i' I I S P I I 1----.----,---,"--�11----,---,-"""""lI - - ----- _,"'i I 1 Design Services For The Built Environment ■ Atlanta Birmingham Cincinnati Columbus Dallas Fort Lauderdale Knoxville Jackson Jacksonville Louisville Memphis Nashville Richmond Tampa E G R E S H A M S M I T A N D P A R T N E R S 6030 Hollywood Blvd. Suite 210 Hollywood, Florida 33024 954.981.9100 FIRM'S FLORIDA CERT. No. AAP000034/CA3806 1826000797/LC26000381 G.D. Klieger, Inc. Consulting Structural Engineers 1909 Harrison St., Suite 204 Hollywood, Florida 33020 -5017 Phone: (954) 923 -2111 EMAIL: gklieger ®att.net 4) 14 � •_rrN w M �_ W Q .. ." 0 Lu � O lu � � t1 EL .� �d r� 4) � r- � � "� C1 111 F- w GERSHON KLIEGER, PE (FL. PE #36109) t , ,- . .1 r f' DEC 19 2012 REVISION No. - Date -- Revision I I I I 1 I ............. .... I — —........ ........................ .1......... i I ....... i ................._............ ...._.. ", I I i i ............................... ............................... .................................. ............................... I � I i GENERAL NOTES S=11 [00 F Ids E : K- 12059 -S -11 .dwg PdT®.:[`: y : 29080.00 -j E :: 12/14/2012 ROOF (TABLE 27.6 -2F. ZONE 3: -58.5 PSF ZONE 4. -41.5 PSF ZONE 5: -34.0 PSF WALL GTABLE 27.8-11 WINDWARD + LEEWARD: 48.7 PSF LEEWARD: -17.4 PSF WINDWARD: -312 PSF WIND ON PARAPET (02X,§_-a- 78.4 PSF 28. COMPONENTS & CLADDING: (CHAPTER 30 - PART 2) BUILDING ZONE ZONE ZONE ZONE ZONE FLAT ROOF 47.3 56.0 ROOFING FU -51.6 86.6 OVERHANG 74.4 WALL +43.1 -47.0-54.6 PARAPET WALL I 1312 GLASS WINDOWS 10 SOFT) 47.2 -51.2 0 It EXT. METAL CLADDING PANELS (SEE NOTE j4) 3. THE WIND LOADS INDICATED N THE TABLE ABOVE HAVE BEEN CALCULATED BASED ON THE 'MAN - FRAME' DESIGN FACTORS OF THE 'ASCE -7'. STRUCTURAL ELEMONTS EXPOSED TO WIND HAVE BEEN DESIGNED BASED ON 'COMPONENTS & CLADDING' FACTORS OF THE CODE 4. WIND LOAD CALCULATIONS ON DOORS 4.1 N THE ABSENCE OF SPECIFIC INFORMATION REGARDING THE WINDOWS/DOORS (AT THE TIME OF PREPARATION OF THESE PLANS), WIND LOADS HAVE BEEN CALCULATED BASED ON THE TRIBUTARY AREA USED FOR EACH TYPE AS INDICATED, PRODUCING THE MAXIMUM POSSIBLE CALCULATED WIND PRESSUE/SUCTION (UNLESS OTHERWISE PERMITTED - SEE CONDITION 'B-). 4.2 THE ABOVE LISTED WIND PRESSURE/SUCTION ASSUME THAT THE SPECIFIC DOOR/ WINDOW PRODUCT APPROVAL DOCUMENTS INDICATE THAT THE TESTED WIND PRESSURE/ SUCTION CAPACITIES HAVE NOT BEEN INCREASED BY A FACTOR OF J. THE CALCULATED PRESSURE/SUCTION VALUES ASSUME Kd - 0.85 CONDITION 'A': IN THE EVENT THAT THE SPECIFIC DOOR/WINDOW PRODUCT APPROVAL DOCUMENTS INDICATE THAT THE TESTED WIND PRESSURE/SUCTION CAPACITIES HAVE BEEN INIREAM BY A FACTOR OF L11 THE CALCULATED PRESSURE/SUCTION VALES SHOWN N THE TABLE ABOVE SHALL BE MULTIPLIED BY 1.176 (TO ACCOUNT FOR Kd 1.001 CONDITION %'- THE EVENT THAT THE OWNER /CONTRACTOR/NA LIF. CAN SUBMIT DATA IDENTIFYING THE TRIBUTARY AREA OF THE ELEMENT THAT CONTROLLED THE TESTED CAPACITY OF THE DOOR/WIDOW. THE ENGINEER -OF- RECORD MAY ADJUST THE ABOVE LOADS DESIGNED USING SAID TRIBUTARY AREA. WIND ZONES FOR ROOF AND WALLS 'a- - 5' -0- (CORNER DISTANCE) ZONE (PERIMETER) 3 2 ZONE 2 (FIELD) 3 2 3 I... TYP. '�h.�J o j GDK JOB#:K dA= G.D. Klieger, Inc. Consulting Structural Engineers 0 1909 Harrison St., Suite 204 EO Hollywood, Florida 33020 -5017 Phone: (954) 923 -2111 EH 0004821 EMAIL- gkUegerOatt.net _XMW s7iLea - - I 1- I i E_ -- I i - I - V'0116 i ' I i' I I S P I I 1----.----,---,"--�11----,---,-"""""lI - - ----- _,"'i I 1 Design Services For The Built Environment ■ Atlanta Birmingham Cincinnati Columbus Dallas Fort Lauderdale Knoxville Jackson Jacksonville Louisville Memphis Nashville Richmond Tampa E G R E S H A M S M I T A N D P A R T N E R S 6030 Hollywood Blvd. Suite 210 Hollywood, Florida 33024 954.981.9100 FIRM'S FLORIDA CERT. No. AAP000034/CA3806 1826000797/LC26000381 G.D. Klieger, Inc. Consulting Structural Engineers 1909 Harrison St., Suite 204 Hollywood, Florida 33020 -5017 Phone: (954) 923 -2111 EMAIL: gklieger ®att.net 4) 14 � •_rrN w M �_ W Q .. ." 0 Lu � O lu � � t1 EL .� �d r� 4) � r- � � "� C1 111 F- w GERSHON KLIEGER, PE (FL. PE #36109) t , ,- . .1 r f' DEC 19 2012 REVISION No. - Date -- Revision I I I I 1 I ............. .... I — —........ ........................ .1......... i I ....... i ................._............ ...._.. ", I I i i ............................... ............................... .................................. ............................... I � I i GENERAL NOTES S=11 [00 F Ids E : K- 12059 -S -11 .dwg PdT®.:[`: y : 29080.00 -j E :: 12/14/2012 (SEE NOTE j4) 3. THE WIND LOADS INDICATED N THE TABLE ABOVE HAVE BEEN CALCULATED BASED ON THE 'MAN - FRAME' DESIGN FACTORS OF THE 'ASCE -7'. STRUCTURAL ELEMONTS EXPOSED TO WIND HAVE BEEN DESIGNED BASED ON 'COMPONENTS & CLADDING' FACTORS OF THE CODE 4. WIND LOAD CALCULATIONS ON DOORS 4.1 N THE ABSENCE OF SPECIFIC INFORMATION REGARDING THE WINDOWS/DOORS (AT THE TIME OF PREPARATION OF THESE PLANS), WIND LOADS HAVE BEEN CALCULATED BASED ON THE TRIBUTARY AREA USED FOR EACH TYPE AS INDICATED, PRODUCING THE MAXIMUM POSSIBLE CALCULATED WIND PRESSUE/SUCTION (UNLESS OTHERWISE PERMITTED - SEE CONDITION 'B-). 4.2 THE ABOVE LISTED WIND PRESSURE/SUCTION ASSUME THAT THE SPECIFIC DOOR/ WINDOW PRODUCT APPROVAL DOCUMENTS INDICATE THAT THE TESTED WIND PRESSURE/ SUCTION CAPACITIES HAVE NOT BEEN INCREASED BY A FACTOR OF J. THE CALCULATED PRESSURE/SUCTION VALUES ASSUME Kd - 0.85 CONDITION 'A': IN THE EVENT THAT THE SPECIFIC DOOR/WINDOW PRODUCT APPROVAL DOCUMENTS INDICATE THAT THE TESTED WIND PRESSURE/SUCTION CAPACITIES HAVE BEEN INIREAM BY A FACTOR OF L11 THE CALCULATED PRESSURE/SUCTION VALES SHOWN N THE TABLE ABOVE SHALL BE MULTIPLIED BY 1.176 (TO ACCOUNT FOR Kd 1.001 CONDITION %'- THE EVENT THAT THE OWNER /CONTRACTOR/NA LIF. CAN SUBMIT DATA IDENTIFYING THE TRIBUTARY AREA OF THE ELEMENT THAT CONTROLLED THE TESTED CAPACITY OF THE DOOR/WIDOW. THE ENGINEER -OF- RECORD MAY ADJUST THE ABOVE LOADS DESIGNED USING SAID TRIBUTARY AREA. WIND ZONES FOR ROOF AND WALLS 'a- - 5' -0- (CORNER DISTANCE) ZONE (PERIMETER) 3 2 ZONE 2 (FIELD) 3 2 3 I... TYP. '�h.�J o j GDK JOB#:K dA= G.D. Klieger, Inc. Consulting Structural Engineers 0 1909 Harrison St., Suite 204 EO Hollywood, Florida 33020 -5017 Phone: (954) 923 -2111 EH 0004821 EMAIL- gkUegerOatt.net _XMW s7iLea - - I 1- I i E_ -- I i - I - V'0116 i ' I i' I I S P I I 1----.----,---,"--�11----,---,-"""""lI - - ----- _,"'i I 1 Design Services For The Built Environment ■ Atlanta Birmingham Cincinnati Columbus Dallas Fort Lauderdale Knoxville Jackson Jacksonville Louisville Memphis Nashville Richmond Tampa E G R E S H A M S M I T A N D P A R T N E R S 6030 Hollywood Blvd. Suite 210 Hollywood, Florida 33024 954.981.9100 FIRM'S FLORIDA CERT. No. AAP000034/CA3806 1826000797/LC26000381 G.D. Klieger, Inc. Consulting Structural Engineers 1909 Harrison St., Suite 204 Hollywood, Florida 33020 -5017 Phone: (954) 923 -2111 EMAIL: gklieger ®att.net 4) 14 � •_rrN w M �_ W Q .. ." 0 Lu � O lu � � t1 EL .� �d r� 4) � r- � � "� C1 111 F- w GERSHON KLIEGER, PE (FL. PE #36109) t , ,- . .1 r f' DEC 19 2012 REVISION No. - Date -- Revision I I I I 1 I ............. .... I — —........ ........................ .1......... i I ....... i ................._............ ...._.. ", I I i i ............................... ............................... .................................. ............................... I � I i GENERAL NOTES S=11 [00 F Ids E : K- 12059 -S -11 .dwg PdT®.:[`: y : 29080.00 -j E :: 12/14/2012 I... TYP. '�h.�J o j GDK JOB#:K dA= G.D. Klieger, Inc. Consulting Structural Engineers 0 1909 Harrison St., Suite 204 EO Hollywood, Florida 33020 -5017 Phone: (954) 923 -2111 EH 0004821 EMAIL- gkUegerOatt.net _XMW s7iLea - - I 1- I i E_ -- I i - I - V'0116 i ' I i' I I S P I I 1----.----,---,"--�11----,---,-"""""lI - - ----- _,"'i I 1 Design Services For The Built Environment ■ Atlanta Birmingham Cincinnati Columbus Dallas Fort Lauderdale Knoxville Jackson Jacksonville Louisville Memphis Nashville Richmond Tampa E G R E S H A M S M I T A N D P A R T N E R S 6030 Hollywood Blvd. Suite 210 Hollywood, Florida 33024 954.981.9100 FIRM'S FLORIDA CERT. No. AAP000034/CA3806 1826000797/LC26000381 G.D. Klieger, Inc. Consulting Structural Engineers 1909 Harrison St., Suite 204 Hollywood, Florida 33020 -5017 Phone: (954) 923 -2111 EMAIL: gklieger ®att.net 4) 14 � •_rrN w M �_ W Q .. ." 0 Lu � O lu � � t1 EL .� �d r� 4) � r- � � "� C1 111 F- w GERSHON KLIEGER, PE (FL. PE #36109) t , ,- . .1 r f' DEC 19 2012 REVISION No. - Date -- Revision I I I I 1 I ............. .... I — —........ ........................ .1......... i I ....... i ................._............ ...._.. ", I I i i ............................... ............................... .................................. ............................... I � I i GENERAL NOTES S=11 [00 F Ids E : K- 12059 -S -11 .dwg PdT®.:[`: y : 29080.00 -j E :: 12/14/2012