13-96-250!� %HA%HA HA NMVLn > mi mi ME :2 :2 Uj zzzzz J J J J J J HA (A 1.4 HA Ki HA H» } I_ Uj Q w w HA HA HA cA HA HA - Q U D 1Z Uj V In zl- NZO�c�LL LL wW1, car- wrroQwwwww Qz <A w <A of t - HA'%W t__ W J HPr EA HA L.�OF- �QJLiJ z -J_a - Ummm i� iA (A fA EA ei iA HA -(f} IZ W G/) {f} GENERAL 1. THE DRAWINGS ARE INTENDED TO SHOW THE GENERAL ARRANGEMENT, DESIGN AND EXTENT OF THE WORK AND ARE PARTIALLY DIAGRAMMATIC. THEY ARE NOT INTENDED TO BE SCALED FOR ROUGH -IN MEASUREMENTS, OR TO SERVE AS SHOP DRAWINGS OR PORTIONS THEREOF. 2 ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED M BE TYPICAL AND SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT, EXCEPT WHERE A DIFFERENT DETAIL OR SECTION IS SHOWN. 5 PRIOR TO START OF CONSTRUCTION. THE CONTRACTOR AND ALL THE SUB- CONTRACTORS SHALL VERIFY ALL GRADES. LINES LEVELS, DIMENSIONS AND COORDINATE EXISTING CONDITIONS AT THE JOB SITE WITH THE PLANS AND SPECIFICATIONS. THEY SHALL REPORT ANY INCONSISTENCIES OR ERRORS IN THE ABOVE M THE ARCHITECT /ENGINEER BEFORE COMMENCING WORK. THE CONTRACTOR AND HIS SUBCONTRACTORS SHALL LAY OUT THEIR WORK FROM ESTABLISHED REFERENCE POINTS AND BE RESPONSIBLE FOR ALL LINES EEVATIONS AND MEASUREMENTS IN CONNECTION WITH THEIR WORK. 4. IF ANY ERRORS OR OMISSIONS APPEAR IN THE DRAWINGS GENERAL NOTES OR OTHER DOCUMENTS THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/1:NNEER IN WRITING OF SUCH OMISSION OR ERROR PRIOR TO PROCEEDING WITH ANY WORK WHICH APPEARS IN QUESTION. IN THE EVENT OF THE CONTRACTOR'S FAILING TO GIVE SUCH AN ADVANCED NOTICE, HE SHALL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY SUCH ERRORS OR OMISSIONS AND THE COST OF RECTIFYING THE SAME. 5. THE CONTRACTOR SHALL USE THE STRUCTURAL DRAWINGS AND SPECIFICATIONS TOGETHER WITH THE ARCHITECTURAL, MECHANICAL, ELECTRICAL AND OTHER TRADE DRAWINGS AND SHOP DRAWINGS, TO LOCATE DEPRESSED SLABS SLOPES, DRAINS OUTLETS RECESSES, OPENINGS BOLT SETTING SLEEVES DIMENSKINS ETC. NOTIFY MRCITECT/IENNETR IN WRITING OF ANY POTENTIAL CONFLICTS BEFORE PROCEEDING WITH THE WORK. & THIS PROJECT INCLUDES SEVERAL STRUCTURAL ELEMENTS TO BE DESIGNED BY THE CONTRACTOR'S OR SUPPLIER'S DELEGATED STRUCTURAL ENGINEER. NOTE THAT ANY INFORMATION (SUCH AS SIZE, DIMENSIONS, REINFORCEMENT. INTERNAL AND EXTERNAL CONNECTIONS, ETC.) PROVIDED IN THESE DRAWINGS ARE ONLY FOR GUIDANCE AND CLOSER COST ESTINATING (UNLESS INDICATED TO BE USED AS MINIMUM REQUIREMENTS). THE DELEGATED ENGINEER(S) SHALL DETERMINE THE FINAL STRUCTURAL REQUIREMENTS, BASED ON HIS/HER CALCULATIONS INFORM A/E OF ANY CHANGES. SO THEY CAN BE INCORPORATED IN THE A/E'S RECORD PLANS AND DETAILS (AND BE RESUBWTTED FOR BUILDING DEPARTMENT REVIEW, IF SO REQUIRED)L THE CONTRACTOR AND HIS SUBS SHALL CONSTRUCT THE ELEMENTS BASED ONLY ON THE FULL DESIGN PLANS AND DETAILS (SHOP DRAWINGS) ISSUED BY THE DELEGATED ENNEER(S), RENEWED BY THE A/E OF RECORD AND APPROVED BY THE REGULATING BUILDING DEPARTMENT. ANY PRICING OF THE DELEGATED ENGINEERED ELEMENTS OFF ANY OTHER PLANS SHALL BE CONSIDERED PRELIMINARY OR FOR GENERAL BUDGET PRICING ONLY. SHOP DRAWINGS RENEW: 1. ALL SHOP DRAWINGS SHALL BE SUBMITTED FOR ENGINEER'S REVIEW ONLY AFTER THEY HAVE BEEN THOROUGHLY REVIEWED BY THE CONTRACTOR FOR CONSTRUCTION METHODS DIMENSIONS FIELD CONDITIONS, 'AS- CONSTRUCTED' DIMENSIONS AND OTHER TRADE REQUIREMENTS AND STAMPED WITH THE CONTRACTOR'S APPROVAL STAMP. 2 THE SHOP DRAWING REiAEW BY THE A/E OF RECORD IS ONLY FOR GENERAL CONFORMANCE WIiHI THE DESIGN CONCEPT AND INFORMATION GIVEN IN THE CONSTRUCTION DOCUMENTS CORRECTIONS OR COMMENTS MADE ON THE SHOP DRAWINGS DURING THE AA REVIEW DO NOT RELIEVE THE CONTRACTOR FROM COMPUANCE WITH THE REQUIREMENTS OF THE PLANS AND SPECIFICATIONS REVIEW OF A SPECIFIC ITEM SHALL NOT INCLUDE REVIEW OF AN ASSEMBLY OF WHICH THE ITEM IS A COMPONENT. THE CONTRACTOR IS RESPONSIBLE FOR DIMENSIONS TO BE CONFIRMED AND CORRELATED AT THE JOBSTE: INFORMATION THAT PERTAINS SOLELY TO THE FABRICATION PROCESSES OR TO THE MEANS METHODS TECHNIQUES SEQUENCES AND PROCEDURES OF CONSTRUCTIM COORDINATION OF THE WORK WITH THAT OF ALL OTHER TRADES AND PERFORMING ALL WORK IN A SAFE AND SATISFACTORY MANNER. 5 THE ENGINEER ASSUMES NO RESPONSIBILITY FOR DIMENSIONS QUANTITIES, ENGINEERING DESIGN PREPARED BY DELEGATED ENGINEERS ERRORS OR OMISSIONS AS A RESULT OF REVIEWING ANY SHOP DRAWINGS ANY ERRORS OR OMISSIONS MUST BE MADE GOOD BY THE CONTRACTOR. IRRESPECTIVE OF RECEIPT, CHECKING OR REVIEW OF DRAWINGS BY THE ENGINEER AND EVEN THOUGH WORK IS DONE IN ACCORDANCE WITH SUCH DRAWINGS 4. BEFORE STRUCTURAL INSPECTIONS CAN BE MADE ON A PORTION OF THE STRUCTURE, ALL RELATED STROP DRAWINGS DELEGATED ENGINEERING. PRODUCT APPROVAL. MANUFACTURER'S DATA AND OTHER RELATED INFORMATION, MUST BE REVIEWED AND ACCEPTED BY THE ENGINEER -OF- RECORD AND APPROVED BY THE BUILDING DEPARTMENT. 5. ALL SHOP DRAWINGS SHALL CONTAIN THE MINIMUM INFORMATION, OUTLINED IN THE LOCAL BUILDING CODE L UNLESS OTHERWISE AGREED UPON, ALL SHOP DRAWINGS SHALL BE SUBMITTED THRU THE ARCHITECT. THE ENGINEER WILL RETURN REVIEWED SHOP DRAWINGS TO THE ARCHTECT. 7. ANY COMMENTS, QUESTIONS AND MODIFICATIONS MADE BY THE SHOP DRAWING DETAIER, TO THE A/E'S DESIGN AND /OR DETAILING, SHALL BE CLEARLY MARKED (CLOUDED OR FLAGGED)L B. CONTRACTOR AND HIS DETAILER SHALL MAKE SURE THAT ALL THE FLAGGED ITEMS ON THE SHOP DRAWINGS HAVE BEEN RESPONDED TO BY THE A/E ITEMS THAT INADVERTENTLY HAVE NOT BEEN RESPONDED TO BY THE A/E SHALL NJ BE CONSIDERED AS A YES OR NO ANSWER THE CONTRACTOR OR HIS DETAILER SHALL COMMUNICATE DIRECTLY WITH THE A/E TO DISCUSS ALL THE UNANSWERED OR STILL QUESTIONABLE ITEMS 9. IF THE CONTRACTOR OR HIS DETAILER ARE NOT IN AGREEMENT OR SATISFIED WITH THE A/E RESPOND TO THEIR QUESTIONS ON THE SHOP DRAWINGS THEY ARE ENCOURAGED TO CALL THE A/E TO DISCUSS THE ISSUES AND CLARIFY THEM FURTHER 10. NO FABRICATION OR CONSTRUCTION SHALL BEGIN UNTIL ALL THE OUTSTANDING ITEMS ON THE SHOP DRAWINGS HAVE BEEN CLARIFIED AND AGREED UPON. 10. DELEGATED ENGINEERED SHOP DRAWINGS IN THE STATE OF FLORIDA, SEE SECTIONS OF - DELEGATED ENGINEERING RESPONSIBUTY' AND DEFINITIONS FOR SPECIFIC STRUCTURAL ELEMENTS / ODMPONENTS DESIGNS IN COMPLIANCE WITH CHAPTER 61G15. OF THE FLORIDA ADMINISTRATIVE CODE CONSTRUCTION MEANS AND METHODS 1. SHORES BRACING AND RESHORES AS REQUIRED BY PROJECT CONDITIONS AND THE LOCAL BUILDING CODE OR THE LOCAL BUILDING DEPARTMENT. CONTRACTOR TO PROVIDE SHOP DRAWINGS (INCLUDING ENGINEERING CALCULATIONS) FOR ALL SHCRES, VERTICAL AND LATERAL BRACING AND RESHORES (AND REMOVAL OF SAME) TO BE USED FOR THIS CONSTRUCTION. THE ABOVE SHALL BE DESIGNED, SIGNED AND SEALED BY A PROFESSIONAL STRUCTURAL ENGINEER (FLORIDA REGISTERED) ENGAGED BY THE CONTRACTOR, AS A DELEGATED ENGINEER FOR THE ABOVE ELEMENTSL THE ENGINEER-OF-RECORD WILL NOT DESIGN FORMWORK AND BRACING, NOR ASSUME RESPONSIBILITY FOR THE SHORES BRACING AND STABILITY DURING CONSTRUCTION. CONTRACTOR TO SUBMIT THE SIGNED AND SEALED SHOP DRAWINGS TO THE ENGINEER OF RECORD, AS REQUIRED. TO BE REVIEWED FOR GENERAL COMPLIANCE WITH THE STRUCTURAL DESIGN INTEND. IF SO REQUIRED. CONTRACTOR TO SUBMIT A COPY OF THESE SIGNED AND SEALED DOCUMENTS, REVIEWED BY THE ENGINEER -OF- RECORD, TO THE LOCAL BUILDING DEPARTMENT. 2 THE CONTRACTOR IS RESPONSIBLE AND SHALL COMPLY WITH THE SAFETY REQUIREMENTS OF LOCAL BUILDING CODE AND ALL OTHER APPLICABLE LOCAL, STATE AND FEDERAL LAWS. 5 PROVIDE AND MAINTAIN GUARD LIGHTS AT ALL BARRICADES, RAILINGS ABSTRACTIONS IN THE STREETS, ROADS OR SIDEWALKS AND ALL TRENCHES OR PITS ADJACENT TO PUBLIC WALKS OR ROADS 4. AT AIR TIMES, PROVIDE PROTECTION AGAINST WEATHER (RAIN, WIND, STORMS OR THE SUN), SO AS TO MAINTAIN ALL WORK, MATERIALS APPARATUS AND FIXTURES FREE FROM INJURY OR DAMAGE PROVIDE ADEQUATE BRACING TO THE ELEMENTS ALREADY IN PLACE (ESPECIALLY MASONRY WALLS) AGAINST WIND FORCES CAPABLE OF DAMAGING THIS WORK. & AT THE END OF THE DAYS WORK, COVER ALL WORK LIKELY TO BE DAMAGED. ANY WORK DAMAGED BY FAILURE TO PROVIDE PROTECTION SHALL BE REMOVED AND REPLACED WITH NEW WORK AT THE CONTRACTOR'S EXPENSE & THE CONTRACTOR SHALL PAY FOR ALL DAMAGES TO ADJACENT STRUCTURES SIDEWALKS AND TO SiREETS OR OTHER PUBLIC PROPERTY OR PUBLIC UTILITIES 7. 'OSHA- SAFETY INSPECTIONS ARE HU A PART OF OUR SERVICES OUR PRESENCE ON STE (FOR OBSERVATIONS INSPECTIONS OF THE WORK IN PROGRESS OR MEETINGS) SHALL HU CONSTRUED AS OUR ACTING AS -OSHA' INSPECTORS. CONFORMING WITH ALL APPLICABLE 'OSHA' SAFETY REGULATIONS IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. STRUCTURAL INSIECEONS CMAL TH JOLD INSPECTOR ri 1. BASED ON THE REQUIREMENTS OF THE FEC AND THE LOCAL CODE ENFORCEMENT DEPARTMENT. THIS PROJECT REQUIRES THRESHOLD INSPECTIONS TO BE MADE DURING THE CONSTRUCTION OF ALL THE STRUCTURAL ELEMENTS (AS USTED HERON OR ELSEWHERE IN THESE DOCUMEITS� 2 IN ORDER TO COMPLY WITH THE ABOVE REQUIREMENTS THE OWNER SHALL RETAIN THE SERVICES OF A LICENSED STRUCTURAL ENGINEER FOR THE PURPOSE OF PERFORMING THE REQUIRED INSPECTION SERVICES 3. THE ASSIGNED STRUCTURAL INSPECTOR SHALL BE NOTIFIED BY THE CONTRACTOR, AT LEAST 24 HOURS PRIOR TO ANY CONCRETE PLACING OR OTHER OPERATIONS THAT WILL CONCEAL STRUCTURAL OEM IS. 4. THE INSPECTIONS MADE BY THE 'SPECIAL THRESHOLD INSPECTOR' ENGINEER (ENGAGED BY THE OWNER) ARE IN ADDITION TO THE INSPECTIONS MADE BY THE LOCAL BUILDING DEPARTMENT. THE CONTRACTOR SHALL COORDINATE THE INSPECTION REQUIREMENTS WITH THE LOCAL BUILDING DEPARTMENT. THE CONTRACTOR SHALL NOTIFY THE BUILDING DEPARTMENT ANY TIME THE ENGINEER HAD BEEN SCHEDULED FOR A STE MST. CONTRACTOR SHALL TiME SCHEDULE THE STE MST OF THE ENGINEER BEFORE THE BUILDING DEPARTMENT INSPECTOR. 5. A 'STATEMENT OF INSPECTION". 'INSPECTION LOG- AND ANY OTHER DOCUMENTS REQUIRED BY THE PERMIT. WILL BE ISSUED AT A TIMELY SCHEDULE OR AT THE COMPLETION OF THE STRUCTURAL WORK, FOR THE ELEMENTS THAT HAVE BEGIN INSPECTED DURING THE COURSE OF THE CONSTRUCTION (AS REQUESTED BY THE CONTRACTOR OR AS REQUIRED BY THE BUILDING DEPARTMENT OR PERMIT DOCUMENTS). 6. WHEN G.D. KLIEGER, INC. (THE ENGINEER -OF- RECORD) WAS NOT ENGAGED TO PROVIDE REQUIRED JOB -STE INSPECTION SERVICES 0.D.K. WILL NOT BE HELD RESPONSIBLE AND LIABLE FOR ANY OF THE CONTRACTOR'S WORK. G.D.K. SHALL ALSO NOT BE HELD RESPONSIBLE FOR ANY WORK APPROVED BY THE INSPECTING ENGINEER (OTHER THAN THE ENGINEER -OF- RECORD) WHCH MODIFIES OR CHANGES THE STRUCTURAL PERU RECORD DOCUMENTS WITHOUT PRIOR REVIEW AND ACCEPTANCE (IN WRITING) BY THE ENVIER -OF- RECORD. SPECIAL THRESHOLD INSPECTION PLAN: 1. SOIL COMPACTION (INSPECTION BY A FOUNDATION ENGINEER) 2 REINFORCED CONCRETE FOOTINGS REINFORCING AND CONCRETE PLACEMENT. 5 REINFORCED CONCRETE SLABS' REINFORCING AND CONCRETE PLACEMENT 4. FORMWORK, SHORES AND RESHO2ES: INSPECT FORMWORK, SHORING AND BRACING (AS PER SHORING PLAN SHOP DRAWINGS)L 5. CONCRETE COLUMNS- REINFORCING AND CONCRETE PLACING. & MASONRY AND REINFORCED MASONRY: BLOCK HORIZONTAL AND VERTICAL REINFORCING. CET. GROUTING. 7. CONCRETE BEAMS & WALLS: REINFORCING AND CONCRETE CASTING. & MISC. CONCRETE ELEMENTS (STAIRS ETC.} REINFORCING AND CONCRETE CASTING. 9. INCIDENTAL CONCRETE, STEEL OR ALUMINUM STRUCTURAL ELEMENTS AS INDICATED ON THE PLANS OR SHOP DRAWINGS 10. EXTERIOR DOORS, WINDOWS & STOREFRONT: INSTALLATION AND ATTACHMENT TO THE SURROUNDING STRUCTURE 11. PRECAST UNITS (JOISTS AND BEAM SOFFITS}. RENFORCING, TENSION CABLES AND CASTING OF CONCRETE (AT THE CASTING YARD) AND INSTALLATION AT THE PROJECT STE STRUCTURAL INSPECTIONS - CONT.: 'SPECIAL INSPECTION' EQUI EMENTS (MIAMI -DADE AND BROWARD COUNTY ONLY - FBC 2010) IF THE LOCAL BUILDING DEPARTMENT REQUIRES 'SPECIAL INSPECTIONS' ON ADDITION TO THE LISTED AS 'THRESHOLD INSPECTIONS'). THEY WILL INCLUDE THE ITEMS LISTED BELOW: A. PRECAST UNITS (FOR QUALITY CONTROL AT CASTING YARD) - (•) B. PRECAST UNITS AND ATTACHMENTS TO MAIN STRUCTURE (AFTER ERECTION BUT BEFORE CONCEALMENT) - (•) C. REINFORCED MASONRY - (•) D. STEEL CONNECTIONS (BOLTED & WELDED) - (*) E SOIL COMPACTION - (a) (*) ITEM INSPECTED BY A FLORIDA REGISTERED ARCHITECT OR PROFFSSICNAL ENGINEER. (p) INSPECTION TO BE PERFORMED BY A GEOTECHNICAL ENGINEER. SEE THE SPECIFIC COUNTY OR CITY FOR THEIR FORM FOR - SPECIAL INSPECTOR' SERVICES,, TO BE PART OF THE PERMIT PLANS. RF iRm DELEGATED ENNEERED CALCULATIONS AND SHOP DRAWINGS: THIS PROJECT REQUIRE THE FOLLOWING DELEGATED ENGINEERED CALCULATIONS AND SHOP DRAWINGS BASED ON THE 'FLORIDA ADMINISTRATIVE CODE', SECTIONS 61G15 -30 AND 6IG15 -31 (ONLY THE ITEMS MARKED [X) APPLY. [ ] WOOD TRUSSES GIRDER TRUSSES AND PREFABRICATED WOOD COMPONENTS (6105- 31.003) ISTEEL BAR - JOISTS AND STEEL GIRDER - TRUSSES (81615- 31.006) i COLD -FORM STUD TRUSSES, JOISTS AND /OR WALLS (61G15- 31.009) STRUCTURAL STEEL SYSTEM (61G15- 31.009) [ ] PRE- ENGINEERED METAL BUILDINGS (61G15- 31.007) [XI PRE - ENGINEERED CONCRETE FLOOR/ROOF SYSTEM. INCLUDING CONCRETE GIRDERS. PRECAST ELEMENTS COMPOSITE O.EMENTS, ETC. (61G15- 31.005, 31.007 & 31.009) DELEGATED ENGINEERED SERVICES, REQUIRED FOR THIS PROJECT: (BASED ON CHAPTER SIG15 OF THE 'FLORIDA ADMINISTRATIVE CODE-) NOTE THAT THE LANGUAGE USED BELOW IS NOT ALWAYS A DIRECT COPY FROM THE ADMINISTRATIVE CODE THE DELEGATED ENGINEER SHALL BE FAMILIAR WITH THE CODE AS PUBUSHED IN THE STATE OF FLORIDA. 'EOR' - DENOTES 'ENGINEER-OF- RECORD' 'DE' - DENOTES 'DELEGATED ENGINEER* BiG15- 30.005: REQUEST FOR & REVIEW OF DELEGATED ENGINEERING DOCUMENTS 1. PORTIONS OF THIS STRUCTURAL DESIGN AND DETAILING ARE BEING DELEGATED TO A 'DE'. THE ENGINEERING DESIGN REQUIRIE10M HAVE BEEN INCLUDED IN THESE DOCUMENTS (PLANS DETAILS SECTIONS AND NOTES). 2 ALL DELEGATED ENGINEERING DOCUMENTS PREPARED BY THE 'DE' SHALL BE SUBMITTED M THE 'EOM TO BE REVIEWED FOR COMPLIANCE WITH THE PROJECT DESIGN REQUIREMENTS AND TO CONFORM WITH THE FOLLOWING: 21 THAT THE DELEGATED ENGINEERING DOCUMENTS HAVE BEEN PREPARED BY A 'PROFESSIONAL ENGINEER- (LICENSED IN THE STATE OF FLORIDA). (-) 22 THAT THE DELEGATED ENGINEERING DOCUMENTS PREPARED BY THE 'DE- CONFIRM WITH THE DESIGN INTENT OF THE 'EOR' AND MEET THE WRITTEN REQUIREMENTS 23 THAT THE EFFECT OF THE 'DE' WORK ON THE OVERALL PROJECT. GENERALLY CONFORMS WITH THE INTENT OF THE -EOR'. ( -) THE -EOR' ASSUMES THAT THE 'DE' PROFESSIONAL LICENSE IS A=i IT IS THE SOLE RESPONSIBILITY OF THE 'DE' (AND NOT OF THE 'EOR') TO ASSURE AND DEMONSTRATE OF REQUIRED) THAT HIS/HER LICENSE IS ACTIVE IN THE STATE OF FLORIDA. 61G15- 30.006: DELEGATED ENGINEER'S RESPONSIBILITY: 1. THE W SHALL REVIEW THE 'EOR' WRITTEN ENGINEERING REQUIREMENTS TO DETERMINE THE APPROPRIATE SCOPE OF THE DELEGATED ENGINEERING WORK. 2 THE DELEGATED ENGINEERING DOCUMENTS SHALL COMPLY WITH THE DESIGN DOCUMENTS PREPARED BY THE 'EOR'. THEY SHALL INCLUDE THE PROJECT IDENTIFICATION AND THE DESIGN CRITERIA USED IN ITS PREPARATION. IF THE 'DE' DETERMINES THERE ARE DETAILS FEATURES OR UNANTICIPATED PROJECT LIMITS CONNECTING WITH THE TOR- PLANS. THE *W SHALL TIMELY CONTACT THE 'EOR' FOR RESOLUTIONS OF CONFLICTS (-) 5 THE 'DE' SHALL FORWARD THE DELEGATED ENGINEERING DOCUMENT TO THE 'EOR' FOR REVIEWL ALL FINAL DELEGATED ENGINEERING DOCUMENTS REQUIRE THE IMPS SEAL AND SIGNATURE OF THE 'DE' AND INCLUDE 51 DRAWINGS INTRODUCING ENGINEERING INPUT SUCH AS DEFINING THE CONFIGURATION OR STRUCTURAL CAPACITY OF STRUCTURAL COMPONENTS AND /OR THEIR ASSEMBLY INTO STRUCTURAL SYSTEMS. 52 CALCULATIONS 53 COMPUTER PRINTOUTS (COMPLEMENTING OR INSTEAD OF MANUAL CALCULATIONS) ACCOMPANIED BY SUFFICIENT DESIGN ASSUMPTIONS AND IDENTIFIED INPUT /OUTPUT INFORMATION TO PERMIT THEIR PROPER EVALUATION. 54 SUCH INFORMATION SHALL BEAR THE IMPRESSED SEAL AND SIGNATURE OF THE 'DE' AS AN INDICATOR THAT SAID ENGINEER HAS ACCEPTED RESPONSIBILITY FOR THE RESULTS () COMMUNICATE COA THESEE QUESTIONS OR ADDITIONAL INFORMATION REQUIREMENTS. ON A TIMELY MANNER TO THE -EOR- (WITH COPIES TO THE CONTRACTOR). RM BASED ON SECTION SIG15- 31.002 (DEFINTIONS). ITEM (6k STRUCTURAL SUBMITTALS WHICH DO NOT REQUIRE THE SEAL OF A PROFESSIONAL ENGINEER, INCLUDE: (a) DRAWING PREPARED SOLELY TO SERVE AS A GUIDE FOR FABRICATION AND INSTALLATION AND REQUIRE NO ENGINEERING INPUT SUCH AS REINFORCING STEEL SHOP DRAWINGS STRUCTURAL STEEL. AND STEEL JOIST AND GIRDER ERECTION DRAWINGS. 61G15- 31.005: DESIGN OF STRUCTURES UTUJ71NG PRECAST AND PRESTRESSED CONCRETE ISt 1. STRUCTURAL ENGINEERING DOCUMENTS INDICATE THE CONFIGURATION OF PRECAST AND PRESTRESSED COMPONENTS 2 THE RESPONSIBILITY FOR THE DESIGN OF PRECAST OR PRESTRESSED CONCRETE COMPONENTS OR SYSTEMS UTILIZING THOSE COMPONENTS ARE BEING DELEGATED TO A 'DE'. THE 'DE' SHALL PROVIDE TO THE 'EOR' ALL ENGINEERING DOCUMENTS FOR THE DESIGN AND DETAILING OF THE ABOVE, FOR 'EOR' REVIEW AS AN INDICATION THAT THE INTENT OF THE *EOR' HAS BEEN UNDERSTOOD AND THAT THE SPECIFIED CRITERIA HAVE BEEN USED. STRUCTURAL *DIE' DOCUMENTS SHALL BEAR THE IMPRESSED SEAL AND SIGNATURE OF THE DELEGATED ENGINEER. 5 STRUCTURAL *W DOCUMENTS SHALL INCLUDE COMPONENT DETAILS, CALCULATIONS FABRICATION AND ERECTION DRAWINGS ALL SUCH SUBMITTALS SHALL IDENTIFY THE SPECIFIC PROJECT. THE EFFECTS OF THE PRECAST AND PRESTRESSED CONCRETE MEMBERS ON OTHER PARTS OF THE BUILDING IS THE RESPONSIBILITY OF THE 'EOR' FOR THE STRUCTURE. 4. THE 'DE' SHALL CLEARLY INDICATE ALL THE LOADS REACTIONS ATTACHMENT REQUIREMENTS (TO THE STRUCTURE DESIGN BY THE -EOR -) AND ALL INFORMATION DERIVED FROM THE PRECAST AND PRESTRESSED DESIGN, AFFECTING THE STRUCTURE DESIGNED BY THE 'EOR'. B1G15- 31.006(110DIFlED� DESIGN OF ALUMINUM OR STEEL AWNINGS. CANOPIES, OVERHANGS AND FACADE: 1. THE ARCHITECTURAL/STRUCTURAL DRAWINGS OF- RECORD INDICATE THE ELEMENTS LOCATION, CONFIGURATION. DIMENSIONS GENERAL APPEARANCE AND ELEMENTS OF THE ABOVE TITLES ELEMENTS POSTS, HANGERS BRACKETS SUPPORTING WAITS AND BEAMS ALL DESIGN LOADS ARE ALSO INCLUDED. 2 THE SYSTEM MANUFACTURER 'S/SUPPLIER'S 'DE' SHALL DESIGN THE ENTIRE SYSTEM INCLUDING ALL THE BEAM/JOIST/RAFTER ELEMENTS DECIDING /GRATING /COVERS AND ALL INTERNAL AND EXTERNAL CONNECTIONS (INCLUDING TO THE STRUCTURE) IN ACCORDANCE WITH THE SPECIFICATIONS LOAD TABLES AND COMPUTER DATA TO SUPPORT THE LOADS PER THE 'EOR' SPECIFICATIONS THE 'EOR' REQUESTS THE SUBMISSION OF THE ENTIRE SYSTEM DESIGN CALCULATIONS (FOR EACH COMPONENT AND CONNECTIONS) AS AN INDICATION OF COMPLIANCE THE SYSTEM MANUFACTURER 'S /SUPPLIER'S 'DE' SHALL SUBMIT A COVER LETTER ALONG WITH THE CALCULATIONS. THE COVER LETTER SHALL BEAR THE SEAL AND SIGNATURE OF A FLORIDA PROFESSIONAL ENGINEER RESPONSIBLE FOR THE DESIGN OF THE SYSTEM. FOUNDAiONS (SPREAD FOOTINGS) THESE RECOMMENDATIONS ARE BASED ON SOIL EXPLORATION AND FOUNDATION RECOMMENDATIONS, MADE BY. *AUL STATE ENGINEERING & TESTING CONSULTANTS INC.' (REPORT DATED 1G-8- 2012). IN THE EVENT OF A DISCREPANCY BETWEEN THESE REQUIREMENTS AND THE REQUIREMENTS IN THE GEOTECHNICAL REPORT, THE MORE STRINGENT SHALL BE USED. 1. FOUNDATIONS ARE DESIGNED TO BEAR ON WELL COMPACTED GRADE OR CLEAN FILL PREPARED TO ACHIEVE A MINIMUM ALLOWABLE BEARING CAPACITY OF 2500 PSF A CERTIFIED TESTING LABORATORY SHALL BE ENGAGED BY THE OWNER M VERIFY THAT THE REQUIRED BEARING CAPACITY WAS OBTAINED. SAID SOIL CAPACITY SHALL BE CERTIFIED AND TESTED BY A REGISTERED FOUNDATION ENGINEER. PRIOR TO CASTING OF CONCRETE IN THE FOOTINGS 2 NATURAL GRADE (OR FUR) BELOW FOOTINGS SHALL BE COMPACTED TO A MINIMUM OF 98% MODIFIED PROCTOR (ASTM D- 1557). 5 TOP OF WALL FOOTINGS TO BE AT THE SAME ELEVATION AS TOP OF COLUMN PAD FOOTINGS STEP WALL FOOTING FROM HIGHER COLUMN FOOTING M THE LOWER ONE (AS DETAILED ON THE PLANS). 4. TOP OF ALL FOOTINGS TO BE A MINIMUM 1' -4' BELOW THE TOP OF CONCRETE SLAB ON GRADE (UNLESS OTHERWISE NOTED TO BE AT LOWER ELEVATION OR CAST MONOLITHIC WITH SLAB) OR MINIMUM 1' -0' BELOW FINISHED GRADE, WHICHEVER IS LOWER. IN THE EVENT THAT THE SLAB STEPS ON EACH SIDE OF THE FOOTING, THE FOOTING SHALL BE 1' -4' BELOW TOP OF THE LOWER SLAB. TO ACCOMMODATE A CONTINUOUS WALL FOOTING, A STEPPED FOOTING MAY BE REQUIRED (SEE DETAIL ON PLAN). 5. REINFORCING IN THE CONTINUOUS WALL FOOTINGS (MONOLITHIC AND /OR NON - MONOLITHIC) SHALL BE SPUCED 38 BAR DIAMETERS MINIMUM AND SHALL EXTEND CONTINUOUSLY THRU ALL FOOTING PADS 6. ALL LONGITUDINAL REBARS IN THE CONTINUOUS WALL FOOTINGS SHALL BE CONTINUED AT BENTS AND CORNERS BY BENDING THE REBARS 48 BAR DIAMETERS AROUND THE CORNERS OR ADDING MATCHING CORNER BARS EXTENDING 48 BAR- DIAMETERS INTO FOOTING EACH SIDE OF CORNER OR BENT. 7. ALL FOOTINGS (MONOLITHIC OR NOT) SHALL BE It MINIMUM THICK. CONCRETE NON -STRI IC7URAL 4 ARS ON GRADE - 1. ALL NON- STRUCTURAL CONCRETE SLABS AND WALKWAYS ON GRADE. AS SHOWN ON THE STRUCTURAL AND /OR ARCHITECTURAL PLANS. SHALL BE AS FOLLOWS: INgffi4RSLAB$ 4- THICK, REINF. W/ 64- 1`1.401.4 GALVANIZED WELDED WIRE FABRIC (UNLESS OTHERWISE NOTED). EXTERIOR SLABS AND WALKS 4- THICK, RONF. W/ 8x8- WIAXW1.4 GALVAIZED WELDED WIRE FABRIC (UNLESS OTHERWISE NOTED). INTERIOR DRIVEWAY (C-AR LANE) SL AR-_- 8- THICK, ROW. W/ 8x8- W2.%W29 GALVANIZED WELDED WIRE FABRIC (UNLESS OTHERWISE NOTED). 2 ALL SLABS ON GRADE TO BE CONSTRUCTED IN ACCORDANCE WITH LATEST A0.1 - 'GUIDE FOR CONCRETE FLOOR AND SLAB CONSTRUCTION' (A.CI. - 302.1R). 5 JOINTS SHALL BE PROVIDED IN ALL INTERIOR SLABS ON GRADE AT ALL COLUMN CENTERLINES DIVIDING THE SLAB INTO SQUARE PANELS NOT TO EXCEED 18 X 18 FL IN SIZE (U.O.N.). CAST SLAB IN LONG ALTERNATE STRIPS. PROVIDE A CONTRACTION JOINT BETWEEN EACH STRIP. SEE PLAN FOR SAW -CUT. CONTRACTION AND ISOLATION JOINT DETAILS. 4. PROVIDE SAW -CUT JOINTS AT ALL SIDEWALKS AT A MAXIMUM SPACING OF FIVE FEET ON CENTERS AND ISOLATION JOINTS AT 20 FEET O.C. (U.O.N.)L 5. FILL MATERIAL SHALL BE PLACED IN LIFTS NOT EXCEEDING If AND 6. COMPACTED TO MINIMUM 95XG MODIFIED PROCTOR (ASTM D -1557) WITHIN A DISTANCE OF 3 FEET BEYOND ALL FOOTING EDGES COORDINATE THESE REQUIREMENTS WITH THE GEOTECHNICAL REPORT AND RECOMMENDATIONS TAKE AT LEAST ONE DENSITY TEST FOR EACH 2,500 SOFT. OF AREA AND 12' BELOW SURFACE SEND RESULTS OF THE TEST TO OWNER. ARCHITECT AND ENGINEER 1. CONCRETE DESIGN AND REINFORCEMENT IN ACCORDANCE WITH 'BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE' (A.CI 318) AND WITH 'DETAILS AND DETAILING OF CONCRETE REINFORCEMENT--(A.C.I 315 - LATEST EDITION 2 ALL CONCRETE WORK IN ACCORDANCE WITH 'SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDING- (A.CI. 301). PRODUCTION OF CONCRETE, DELIVERY, PLACING AND CURING TO BE IN ACCORDANCE WITH 'HOT WEATHER CONCRETING' (A.C.L 305R)L 5 ALL REINFORCING TO BE NEW BILLET STEEL CONFORMING TO THE LATEST A.&T.M. A -615 GRADE 60, FABRICATED IN ACCORDANCE WITH C.R.S.L MANUAL OF STANDARD PRACTICE AND PLACED W ACCORDANCE WITH A.C.I. 315 AND C.R.S.L MANUAL OF STANDARD PRACTICE. 4. ALL REINFORCING SHALL BE DEFORMED BARS, CLEAN OF OIL. SCALE AND RUST. 5 • DOWELS TO BE SAME SIZE AND NUMBER AS VERTICAL REBARS ABOVE LAP 36 BAR DIAMETER OR MINIMUM OF 18 INCHES U.O.N. PROVIDE RIGID TEMPLATES FOR COLUMN DOWEL LOCATION. PROVIDE STANDARD HOOKS AT TOP OF ALL VERTICAL REINFORCEMENT AT NON - CONTINUOUS COLUMNS (U.O.N.). 5.1 ADD 2 SETS OF TIES (SPACED AT 3' O.C. MAX) BELOW THE 'OFFSET -BENT- IN THE VERTICAL ROARS AT THE LAP LOCATION WITH THE CAGE ABOVE. TIE - COLUMNS (CONSTRUCTED WITH NO 'OFFSET -BENT' DO NOT REQUIRED ADDED TES). 5.2 UNLESS OTHERWISE INDICATED ALL COLUMNS SHALL BE EXTENDED TO THE TOP OF THE ROOF PARAPET. 5.3 ALL DOWELS FOR COLUMNS SHALL BE SECURED IN POSITION PRIOR TO CONCRETING. PUSHING THE DOWELS INTO POSITION IN WET CONCRETE IS NOT PERMITTED. 6, REAM REINFORCEMENT: LAPPED 36 BAR DIAMETER OR MINIMUM 18 INCHES (SEE BEAM DIAGRAM ON PLAN). BOTTOM BARS SPUCED ONLY AT SUPPORTS TOP BARS SPUCED ONLY AT MID -SPAN. ALL TOP BARS HOOKED AT NON - CONTINUOUS EDGES (U.O.N.). ALL HOOKS TO BE STANDARD 90 OR 180 DEGREE HOOKS AS REQUIRED (U.O.N.). TIES OR STIRRUPS SHALL BE SPACED AS INDICATED ON THE BEAM SCHEDULE, MEASURED FROM SUPPORT TO SUPPORT (U.OA)L EXAMPLE 406' MG E.E BAL Olt 0.G, MEANS 4 TIES AT 6' O.C. AT EACH END OF EACH SPAN, WITH TES AT 12' O.C. IN THE MIDDLE (BETWEEN THE TWO END SUPPORTS). CONTACT ENGINEER IF THIS REQUIRE FURTHER CLARIFICATIONS. 7. ADDED REINFORCEMENT: PROVIDE ADDITIONAL CORNER BARS BENT 38 INCHES MINIMUM EACH WAY AT V AND 'T' CORNERS IN OUTER FACES OF ALL BEAMS TO MATCH ALL HORIZONTAL BAR (TOP, BOTTOM AND INTERMEDIATE REBARS). & UNLESS OTHERWISE SPECIFICALLY INDICATED ON THE PLANS OR DETAILS, ALL REM END HOOKS SHOWN OR REQUIRED AT ALL TYPES OF REINFORCED CONCRETE ELEMENTS SHALL BE THE ACI STANDARD LENGTH FOR 90 OR 180 DEGREES HOOKS SLAB TEMPERATURE REINFORCING ALL SLABS SHALL HAVE TEMPERATURE REINFORCING PERPENDICULAR TO THE DIRECTION OF THE MAIN REBARS (U.ON. ON PLANS). TEMPERATURE REINFORCING TO BE AT MINIMUM 04 AT 12. O.C. IN SLABS UP TO 8' THICK. 9. CONCRETE TIE BEAM: A MINIMUM CONCRETE TE BEAM (AS SPECIFIED HEREIN) SHALL BE PROVIDED AT EACH FLOOR OR ROOF LEVEL. IF A BEAM WAS NOT CALLED FOR ON THE PLANS THE TIE BEAM SHALL BE A MINIMUM OF 8' X 12', REINFORCED WITH (2) -05 TOP AND BOTTOM AND 03 TIES, (4) AT It O.C. EACH END, BALANCE AT 48' 0.C.. DROP BOTTOM OF THE BEAM OVER OPENINGS ADD (2)-#5 BOTTOM AND 03 TIES AT 6' O.C. THRUOUT. THESE BEAMS ARE NOT IN ADDITION TO BEAMS ALREADY INDICATED AND SCHEDULED ON THE PLANS FOR THE SAME LOCATION. 10. CURING & PROTECTION: ALL STRUCTURAL SLABS AND SLABS -ON -GRADE SHALL BE CURED WITH MOIST BURLAP COVER (KEPT MOIST FOR 7 DAYS). SPRAY ON CURING COMPOUNDS (INCLUDING CURING/SEALERS/HARDENERS) MAY BE CONSIDERED. CONTRACTOR TO SUBMIT TO ARCHITECT/ENGINEER MATERIAL SPECIFICATIONS AND DATA, FOR REVIEW AND ACCEPTANCE PRIOR TO APPLICATION. NO SLAB CONCRETE SHALL BE LET TO DRY WITHOUT ANY CURING. 11. CONCRETE COVER (UNLESS OTHERWISE DETAILED ON DRAWINGS} ELEMENT' CONCRETE COVER: TOP BOTTOM SIDES Y WALL & COLUMN PAD FOOTING Y q NON- STRUCT. SLAB -ON -GRADE Q lj n; LD (6) - 07 ELEVATED SLABS INTERIOR 1 1 - T � T m ELEVATED SLABS EXTERIOR m NO. 6 AND LARGER BARS 5' -8' TO 6' -10' BU8 743 m 7u a) a) > OL 3 U PARAPET WALL o a) CL L L CL CD U Q !� %HA%HA HA NMVLn > mi mi ME :2 :2 Uj zzzzz J J J J J J HA (A 1.4 HA Ki HA H» } I_ Uj Q w w HA HA HA cA HA HA - Q U D 1Z Uj V In zl- NZO�c�LL LL wW1, car- wrroQwwwww Qz <A w <A of t - HA'%W t__ W J HPr EA HA L.�OF- �QJLiJ z -J_a - Ummm i� iA (A fA EA ei iA HA -(f} IZ W G/) {f} GENERAL 1. THE DRAWINGS ARE INTENDED TO SHOW THE GENERAL ARRANGEMENT, DESIGN AND EXTENT OF THE WORK AND ARE PARTIALLY DIAGRAMMATIC. THEY ARE NOT INTENDED TO BE SCALED FOR ROUGH -IN MEASUREMENTS, OR TO SERVE AS SHOP DRAWINGS OR PORTIONS THEREOF. 2 ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED M BE TYPICAL AND SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT, EXCEPT WHERE A DIFFERENT DETAIL OR SECTION IS SHOWN. 5 PRIOR TO START OF CONSTRUCTION. THE CONTRACTOR AND ALL THE SUB- CONTRACTORS SHALL VERIFY ALL GRADES. LINES LEVELS, DIMENSIONS AND COORDINATE EXISTING CONDITIONS AT THE JOB SITE WITH THE PLANS AND SPECIFICATIONS. THEY SHALL REPORT ANY INCONSISTENCIES OR ERRORS IN THE ABOVE M THE ARCHITECT /ENGINEER BEFORE COMMENCING WORK. THE CONTRACTOR AND HIS SUBCONTRACTORS SHALL LAY OUT THEIR WORK FROM ESTABLISHED REFERENCE POINTS AND BE RESPONSIBLE FOR ALL LINES EEVATIONS AND MEASUREMENTS IN CONNECTION WITH THEIR WORK. 4. IF ANY ERRORS OR OMISSIONS APPEAR IN THE DRAWINGS GENERAL NOTES OR OTHER DOCUMENTS THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/1:NNEER IN WRITING OF SUCH OMISSION OR ERROR PRIOR TO PROCEEDING WITH ANY WORK WHICH APPEARS IN QUESTION. IN THE EVENT OF THE CONTRACTOR'S FAILING TO GIVE SUCH AN ADVANCED NOTICE, HE SHALL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY SUCH ERRORS OR OMISSIONS AND THE COST OF RECTIFYING THE SAME. 5. THE CONTRACTOR SHALL USE THE STRUCTURAL DRAWINGS AND SPECIFICATIONS TOGETHER WITH THE ARCHITECTURAL, MECHANICAL, ELECTRICAL AND OTHER TRADE DRAWINGS AND SHOP DRAWINGS, TO LOCATE DEPRESSED SLABS SLOPES, DRAINS OUTLETS RECESSES, OPENINGS BOLT SETTING SLEEVES DIMENSKINS ETC. NOTIFY MRCITECT/IENNETR IN WRITING OF ANY POTENTIAL CONFLICTS BEFORE PROCEEDING WITH THE WORK. & THIS PROJECT INCLUDES SEVERAL STRUCTURAL ELEMENTS TO BE DESIGNED BY THE CONTRACTOR'S OR SUPPLIER'S DELEGATED STRUCTURAL ENGINEER. NOTE THAT ANY INFORMATION (SUCH AS SIZE, DIMENSIONS, REINFORCEMENT. INTERNAL AND EXTERNAL CONNECTIONS, ETC.) PROVIDED IN THESE DRAWINGS ARE ONLY FOR GUIDANCE AND CLOSER COST ESTINATING (UNLESS INDICATED TO BE USED AS MINIMUM REQUIREMENTS). THE DELEGATED ENGINEER(S) SHALL DETERMINE THE FINAL STRUCTURAL REQUIREMENTS, BASED ON HIS/HER CALCULATIONS INFORM A/E OF ANY CHANGES. SO THEY CAN BE INCORPORATED IN THE A/E'S RECORD PLANS AND DETAILS (AND BE RESUBWTTED FOR BUILDING DEPARTMENT REVIEW, IF SO REQUIRED)L THE CONTRACTOR AND HIS SUBS SHALL CONSTRUCT THE ELEMENTS BASED ONLY ON THE FULL DESIGN PLANS AND DETAILS (SHOP DRAWINGS) ISSUED BY THE DELEGATED ENNEER(S), RENEWED BY THE A/E OF RECORD AND APPROVED BY THE REGULATING BUILDING DEPARTMENT. ANY PRICING OF THE DELEGATED ENGINEERED ELEMENTS OFF ANY OTHER PLANS SHALL BE CONSIDERED PRELIMINARY OR FOR GENERAL BUDGET PRICING ONLY. SHOP DRAWINGS RENEW: 1. ALL SHOP DRAWINGS SHALL BE SUBMITTED FOR ENGINEER'S REVIEW ONLY AFTER THEY HAVE BEEN THOROUGHLY REVIEWED BY THE CONTRACTOR FOR CONSTRUCTION METHODS DIMENSIONS FIELD CONDITIONS, 'AS- CONSTRUCTED' DIMENSIONS AND OTHER TRADE REQUIREMENTS AND STAMPED WITH THE CONTRACTOR'S APPROVAL STAMP. 2 THE SHOP DRAWING REiAEW BY THE A/E OF RECORD IS ONLY FOR GENERAL CONFORMANCE WIiHI THE DESIGN CONCEPT AND INFORMATION GIVEN IN THE CONSTRUCTION DOCUMENTS CORRECTIONS OR COMMENTS MADE ON THE SHOP DRAWINGS DURING THE AA REVIEW DO NOT RELIEVE THE CONTRACTOR FROM COMPUANCE WITH THE REQUIREMENTS OF THE PLANS AND SPECIFICATIONS REVIEW OF A SPECIFIC ITEM SHALL NOT INCLUDE REVIEW OF AN ASSEMBLY OF WHICH THE ITEM IS A COMPONENT. THE CONTRACTOR IS RESPONSIBLE FOR DIMENSIONS TO BE CONFIRMED AND CORRELATED AT THE JOBSTE: INFORMATION THAT PERTAINS SOLELY TO THE FABRICATION PROCESSES OR TO THE MEANS METHODS TECHNIQUES SEQUENCES AND PROCEDURES OF CONSTRUCTIM COORDINATION OF THE WORK WITH THAT OF ALL OTHER TRADES AND PERFORMING ALL WORK IN A SAFE AND SATISFACTORY MANNER. 5 THE ENGINEER ASSUMES NO RESPONSIBILITY FOR DIMENSIONS QUANTITIES, ENGINEERING DESIGN PREPARED BY DELEGATED ENGINEERS ERRORS OR OMISSIONS AS A RESULT OF REVIEWING ANY SHOP DRAWINGS ANY ERRORS OR OMISSIONS MUST BE MADE GOOD BY THE CONTRACTOR. IRRESPECTIVE OF RECEIPT, CHECKING OR REVIEW OF DRAWINGS BY THE ENGINEER AND EVEN THOUGH WORK IS DONE IN ACCORDANCE WITH SUCH DRAWINGS 4. BEFORE STRUCTURAL INSPECTIONS CAN BE MADE ON A PORTION OF THE STRUCTURE, ALL RELATED STROP DRAWINGS DELEGATED ENGINEERING. PRODUCT APPROVAL. MANUFACTURER'S DATA AND OTHER RELATED INFORMATION, MUST BE REVIEWED AND ACCEPTED BY THE ENGINEER -OF- RECORD AND APPROVED BY THE BUILDING DEPARTMENT. 5. ALL SHOP DRAWINGS SHALL CONTAIN THE MINIMUM INFORMATION, OUTLINED IN THE LOCAL BUILDING CODE L UNLESS OTHERWISE AGREED UPON, ALL SHOP DRAWINGS SHALL BE SUBMITTED THRU THE ARCHITECT. THE ENGINEER WILL RETURN REVIEWED SHOP DRAWINGS TO THE ARCHTECT. 7. ANY COMMENTS, QUESTIONS AND MODIFICATIONS MADE BY THE SHOP DRAWING DETAIER, TO THE A/E'S DESIGN AND /OR DETAILING, SHALL BE CLEARLY MARKED (CLOUDED OR FLAGGED)L B. CONTRACTOR AND HIS DETAILER SHALL MAKE SURE THAT ALL THE FLAGGED ITEMS ON THE SHOP DRAWINGS HAVE BEEN RESPONDED TO BY THE A/E ITEMS THAT INADVERTENTLY HAVE NOT BEEN RESPONDED TO BY THE A/E SHALL NJ BE CONSIDERED AS A YES OR NO ANSWER THE CONTRACTOR OR HIS DETAILER SHALL COMMUNICATE DIRECTLY WITH THE A/E TO DISCUSS ALL THE UNANSWERED OR STILL QUESTIONABLE ITEMS 9. IF THE CONTRACTOR OR HIS DETAILER ARE NOT IN AGREEMENT OR SATISFIED WITH THE A/E RESPOND TO THEIR QUESTIONS ON THE SHOP DRAWINGS THEY ARE ENCOURAGED TO CALL THE A/E TO DISCUSS THE ISSUES AND CLARIFY THEM FURTHER 10. NO FABRICATION OR CONSTRUCTION SHALL BEGIN UNTIL ALL THE OUTSTANDING ITEMS ON THE SHOP DRAWINGS HAVE BEEN CLARIFIED AND AGREED UPON. 10. DELEGATED ENGINEERED SHOP DRAWINGS IN THE STATE OF FLORIDA, SEE SECTIONS OF - DELEGATED ENGINEERING RESPONSIBUTY' AND DEFINITIONS FOR SPECIFIC STRUCTURAL ELEMENTS / ODMPONENTS DESIGNS IN COMPLIANCE WITH CHAPTER 61G15. OF THE FLORIDA ADMINISTRATIVE CODE CONSTRUCTION MEANS AND METHODS 1. SHORES BRACING AND RESHORES AS REQUIRED BY PROJECT CONDITIONS AND THE LOCAL BUILDING CODE OR THE LOCAL BUILDING DEPARTMENT. CONTRACTOR TO PROVIDE SHOP DRAWINGS (INCLUDING ENGINEERING CALCULATIONS) FOR ALL SHCRES, VERTICAL AND LATERAL BRACING AND RESHORES (AND REMOVAL OF SAME) TO BE USED FOR THIS CONSTRUCTION. THE ABOVE SHALL BE DESIGNED, SIGNED AND SEALED BY A PROFESSIONAL STRUCTURAL ENGINEER (FLORIDA REGISTERED) ENGAGED BY THE CONTRACTOR, AS A DELEGATED ENGINEER FOR THE ABOVE ELEMENTSL THE ENGINEER-OF-RECORD WILL NOT DESIGN FORMWORK AND BRACING, NOR ASSUME RESPONSIBILITY FOR THE SHORES BRACING AND STABILITY DURING CONSTRUCTION. CONTRACTOR TO SUBMIT THE SIGNED AND SEALED SHOP DRAWINGS TO THE ENGINEER OF RECORD, AS REQUIRED. TO BE REVIEWED FOR GENERAL COMPLIANCE WITH THE STRUCTURAL DESIGN INTEND. IF SO REQUIRED. CONTRACTOR TO SUBMIT A COPY OF THESE SIGNED AND SEALED DOCUMENTS, REVIEWED BY THE ENGINEER -OF- RECORD, TO THE LOCAL BUILDING DEPARTMENT. 2 THE CONTRACTOR IS RESPONSIBLE AND SHALL COMPLY WITH THE SAFETY REQUIREMENTS OF LOCAL BUILDING CODE AND ALL OTHER APPLICABLE LOCAL, STATE AND FEDERAL LAWS. 5 PROVIDE AND MAINTAIN GUARD LIGHTS AT ALL BARRICADES, RAILINGS ABSTRACTIONS IN THE STREETS, ROADS OR SIDEWALKS AND ALL TRENCHES OR PITS ADJACENT TO PUBLIC WALKS OR ROADS 4. AT AIR TIMES, PROVIDE PROTECTION AGAINST WEATHER (RAIN, WIND, STORMS OR THE SUN), SO AS TO MAINTAIN ALL WORK, MATERIALS APPARATUS AND FIXTURES FREE FROM INJURY OR DAMAGE PROVIDE ADEQUATE BRACING TO THE ELEMENTS ALREADY IN PLACE (ESPECIALLY MASONRY WALLS) AGAINST WIND FORCES CAPABLE OF DAMAGING THIS WORK. & AT THE END OF THE DAYS WORK, COVER ALL WORK LIKELY TO BE DAMAGED. ANY WORK DAMAGED BY FAILURE TO PROVIDE PROTECTION SHALL BE REMOVED AND REPLACED WITH NEW WORK AT THE CONTRACTOR'S EXPENSE & THE CONTRACTOR SHALL PAY FOR ALL DAMAGES TO ADJACENT STRUCTURES SIDEWALKS AND TO SiREETS OR OTHER PUBLIC PROPERTY OR PUBLIC UTILITIES 7. 'OSHA- SAFETY INSPECTIONS ARE HU A PART OF OUR SERVICES OUR PRESENCE ON STE (FOR OBSERVATIONS INSPECTIONS OF THE WORK IN PROGRESS OR MEETINGS) SHALL HU CONSTRUED AS OUR ACTING AS -OSHA' INSPECTORS. CONFORMING WITH ALL APPLICABLE 'OSHA' SAFETY REGULATIONS IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. STRUCTURAL INSIECEONS CMAL TH JOLD INSPECTOR ri 1. BASED ON THE REQUIREMENTS OF THE FEC AND THE LOCAL CODE ENFORCEMENT DEPARTMENT. THIS PROJECT REQUIRES THRESHOLD INSPECTIONS TO BE MADE DURING THE CONSTRUCTION OF ALL THE STRUCTURAL ELEMENTS (AS USTED HERON OR ELSEWHERE IN THESE DOCUMEITS� 2 IN ORDER TO COMPLY WITH THE ABOVE REQUIREMENTS THE OWNER SHALL RETAIN THE SERVICES OF A LICENSED STRUCTURAL ENGINEER FOR THE PURPOSE OF PERFORMING THE REQUIRED INSPECTION SERVICES 3. THE ASSIGNED STRUCTURAL INSPECTOR SHALL BE NOTIFIED BY THE CONTRACTOR, AT LEAST 24 HOURS PRIOR TO ANY CONCRETE PLACING OR OTHER OPERATIONS THAT WILL CONCEAL STRUCTURAL OEM IS. 4. THE INSPECTIONS MADE BY THE 'SPECIAL THRESHOLD INSPECTOR' ENGINEER (ENGAGED BY THE OWNER) ARE IN ADDITION TO THE INSPECTIONS MADE BY THE LOCAL BUILDING DEPARTMENT. THE CONTRACTOR SHALL COORDINATE THE INSPECTION REQUIREMENTS WITH THE LOCAL BUILDING DEPARTMENT. THE CONTRACTOR SHALL NOTIFY THE BUILDING DEPARTMENT ANY TIME THE ENGINEER HAD BEEN SCHEDULED FOR A STE MST. CONTRACTOR SHALL TiME SCHEDULE THE STE MST OF THE ENGINEER BEFORE THE BUILDING DEPARTMENT INSPECTOR. 5. A 'STATEMENT OF INSPECTION". 'INSPECTION LOG- AND ANY OTHER DOCUMENTS REQUIRED BY THE PERMIT. WILL BE ISSUED AT A TIMELY SCHEDULE OR AT THE COMPLETION OF THE STRUCTURAL WORK, FOR THE ELEMENTS THAT HAVE BEGIN INSPECTED DURING THE COURSE OF THE CONSTRUCTION (AS REQUESTED BY THE CONTRACTOR OR AS REQUIRED BY THE BUILDING DEPARTMENT OR PERMIT DOCUMENTS). 6. WHEN G.D. KLIEGER, INC. (THE ENGINEER -OF- RECORD) WAS NOT ENGAGED TO PROVIDE REQUIRED JOB -STE INSPECTION SERVICES 0.D.K. WILL NOT BE HELD RESPONSIBLE AND LIABLE FOR ANY OF THE CONTRACTOR'S WORK. G.D.K. SHALL ALSO NOT BE HELD RESPONSIBLE FOR ANY WORK APPROVED BY THE INSPECTING ENGINEER (OTHER THAN THE ENGINEER -OF- RECORD) WHCH MODIFIES OR CHANGES THE STRUCTURAL PERU RECORD DOCUMENTS WITHOUT PRIOR REVIEW AND ACCEPTANCE (IN WRITING) BY THE ENVIER -OF- RECORD. SPECIAL THRESHOLD INSPECTION PLAN: 1. SOIL COMPACTION (INSPECTION BY A FOUNDATION ENGINEER) 2 REINFORCED CONCRETE FOOTINGS REINFORCING AND CONCRETE PLACEMENT. 5 REINFORCED CONCRETE SLABS' REINFORCING AND CONCRETE PLACEMENT 4. FORMWORK, SHORES AND RESHO2ES: INSPECT FORMWORK, SHORING AND BRACING (AS PER SHORING PLAN SHOP DRAWINGS)L 5. CONCRETE COLUMNS- REINFORCING AND CONCRETE PLACING. & MASONRY AND REINFORCED MASONRY: BLOCK HORIZONTAL AND VERTICAL REINFORCING. CET. GROUTING. 7. CONCRETE BEAMS & WALLS: REINFORCING AND CONCRETE CASTING. & MISC. CONCRETE ELEMENTS (STAIRS ETC.} REINFORCING AND CONCRETE CASTING. 9. INCIDENTAL CONCRETE, STEEL OR ALUMINUM STRUCTURAL ELEMENTS AS INDICATED ON THE PLANS OR SHOP DRAWINGS 10. EXTERIOR DOORS, WINDOWS & STOREFRONT: INSTALLATION AND ATTACHMENT TO THE SURROUNDING STRUCTURE 11. PRECAST UNITS (JOISTS AND BEAM SOFFITS}. RENFORCING, TENSION CABLES AND CASTING OF CONCRETE (AT THE CASTING YARD) AND INSTALLATION AT THE PROJECT STE STRUCTURAL INSPECTIONS - CONT.: 'SPECIAL INSPECTION' EQUI EMENTS (MIAMI -DADE AND BROWARD COUNTY ONLY - FBC 2010) IF THE LOCAL BUILDING DEPARTMENT REQUIRES 'SPECIAL INSPECTIONS' ON ADDITION TO THE LISTED AS 'THRESHOLD INSPECTIONS'). THEY WILL INCLUDE THE ITEMS LISTED BELOW: A. PRECAST UNITS (FOR QUALITY CONTROL AT CASTING YARD) - (•) B. PRECAST UNITS AND ATTACHMENTS TO MAIN STRUCTURE (AFTER ERECTION BUT BEFORE CONCEALMENT) - (•) C. REINFORCED MASONRY - (•) D. STEEL CONNECTIONS (BOLTED & WELDED) - (*) E SOIL COMPACTION - (a) (*) ITEM INSPECTED BY A FLORIDA REGISTERED ARCHITECT OR PROFFSSICNAL ENGINEER. (p) INSPECTION TO BE PERFORMED BY A GEOTECHNICAL ENGINEER. SEE THE SPECIFIC COUNTY OR CITY FOR THEIR FORM FOR - SPECIAL INSPECTOR' SERVICES,, TO BE PART OF THE PERMIT PLANS. RF iRm DELEGATED ENNEERED CALCULATIONS AND SHOP DRAWINGS: THIS PROJECT REQUIRE THE FOLLOWING DELEGATED ENGINEERED CALCULATIONS AND SHOP DRAWINGS BASED ON THE 'FLORIDA ADMINISTRATIVE CODE', SECTIONS 61G15 -30 AND 6IG15 -31 (ONLY THE ITEMS MARKED [X) APPLY. [ ] WOOD TRUSSES GIRDER TRUSSES AND PREFABRICATED WOOD COMPONENTS (6105- 31.003) ISTEEL BAR - JOISTS AND STEEL GIRDER - TRUSSES (81615- 31.006) i COLD -FORM STUD TRUSSES, JOISTS AND /OR WALLS (61G15- 31.009) STRUCTURAL STEEL SYSTEM (61G15- 31.009) [ ] PRE- ENGINEERED METAL BUILDINGS (61G15- 31.007) [XI PRE - ENGINEERED CONCRETE FLOOR/ROOF SYSTEM. INCLUDING CONCRETE GIRDERS. PRECAST ELEMENTS COMPOSITE O.EMENTS, ETC. (61G15- 31.005, 31.007 & 31.009) DELEGATED ENGINEERED SERVICES, REQUIRED FOR THIS PROJECT: (BASED ON CHAPTER SIG15 OF THE 'FLORIDA ADMINISTRATIVE CODE-) NOTE THAT THE LANGUAGE USED BELOW IS NOT ALWAYS A DIRECT COPY FROM THE ADMINISTRATIVE CODE THE DELEGATED ENGINEER SHALL BE FAMILIAR WITH THE CODE AS PUBUSHED IN THE STATE OF FLORIDA. 'EOR' - DENOTES 'ENGINEER-OF- RECORD' 'DE' - DENOTES 'DELEGATED ENGINEER* BiG15- 30.005: REQUEST FOR & REVIEW OF DELEGATED ENGINEERING DOCUMENTS 1. PORTIONS OF THIS STRUCTURAL DESIGN AND DETAILING ARE BEING DELEGATED TO A 'DE'. THE ENGINEERING DESIGN REQUIRIE10M HAVE BEEN INCLUDED IN THESE DOCUMENTS (PLANS DETAILS SECTIONS AND NOTES). 2 ALL DELEGATED ENGINEERING DOCUMENTS PREPARED BY THE 'DE' SHALL BE SUBMITTED M THE 'EOM TO BE REVIEWED FOR COMPLIANCE WITH THE PROJECT DESIGN REQUIREMENTS AND TO CONFORM WITH THE FOLLOWING: 21 THAT THE DELEGATED ENGINEERING DOCUMENTS HAVE BEEN PREPARED BY A 'PROFESSIONAL ENGINEER- (LICENSED IN THE STATE OF FLORIDA). (-) 22 THAT THE DELEGATED ENGINEERING DOCUMENTS PREPARED BY THE 'DE- CONFIRM WITH THE DESIGN INTENT OF THE 'EOR' AND MEET THE WRITTEN REQUIREMENTS 23 THAT THE EFFECT OF THE 'DE' WORK ON THE OVERALL PROJECT. GENERALLY CONFORMS WITH THE INTENT OF THE -EOR'. ( -) THE -EOR' ASSUMES THAT THE 'DE' PROFESSIONAL LICENSE IS A=i IT IS THE SOLE RESPONSIBILITY OF THE 'DE' (AND NOT OF THE 'EOR') TO ASSURE AND DEMONSTRATE OF REQUIRED) THAT HIS/HER LICENSE IS ACTIVE IN THE STATE OF FLORIDA. 61G15- 30.006: DELEGATED ENGINEER'S RESPONSIBILITY: 1. THE W SHALL REVIEW THE 'EOR' WRITTEN ENGINEERING REQUIREMENTS TO DETERMINE THE APPROPRIATE SCOPE OF THE DELEGATED ENGINEERING WORK. 2 THE DELEGATED ENGINEERING DOCUMENTS SHALL COMPLY WITH THE DESIGN DOCUMENTS PREPARED BY THE 'EOR'. THEY SHALL INCLUDE THE PROJECT IDENTIFICATION AND THE DESIGN CRITERIA USED IN ITS PREPARATION. IF THE 'DE' DETERMINES THERE ARE DETAILS FEATURES OR UNANTICIPATED PROJECT LIMITS CONNECTING WITH THE TOR- PLANS. THE *W SHALL TIMELY CONTACT THE 'EOR' FOR RESOLUTIONS OF CONFLICTS (-) 5 THE 'DE' SHALL FORWARD THE DELEGATED ENGINEERING DOCUMENT TO THE 'EOR' FOR REVIEWL ALL FINAL DELEGATED ENGINEERING DOCUMENTS REQUIRE THE IMPS SEAL AND SIGNATURE OF THE 'DE' AND INCLUDE 51 DRAWINGS INTRODUCING ENGINEERING INPUT SUCH AS DEFINING THE CONFIGURATION OR STRUCTURAL CAPACITY OF STRUCTURAL COMPONENTS AND /OR THEIR ASSEMBLY INTO STRUCTURAL SYSTEMS. 52 CALCULATIONS 53 COMPUTER PRINTOUTS (COMPLEMENTING OR INSTEAD OF MANUAL CALCULATIONS) ACCOMPANIED BY SUFFICIENT DESIGN ASSUMPTIONS AND IDENTIFIED INPUT /OUTPUT INFORMATION TO PERMIT THEIR PROPER EVALUATION. 54 SUCH INFORMATION SHALL BEAR THE IMPRESSED SEAL AND SIGNATURE OF THE 'DE' AS AN INDICATOR THAT SAID ENGINEER HAS ACCEPTED RESPONSIBILITY FOR THE RESULTS () COMMUNICATE COA THESEE QUESTIONS OR ADDITIONAL INFORMATION REQUIREMENTS. ON A TIMELY MANNER TO THE -EOR- (WITH COPIES TO THE CONTRACTOR). RM BASED ON SECTION SIG15- 31.002 (DEFINTIONS). ITEM (6k STRUCTURAL SUBMITTALS WHICH DO NOT REQUIRE THE SEAL OF A PROFESSIONAL ENGINEER, INCLUDE: (a) DRAWING PREPARED SOLELY TO SERVE AS A GUIDE FOR FABRICATION AND INSTALLATION AND REQUIRE NO ENGINEERING INPUT SUCH AS REINFORCING STEEL SHOP DRAWINGS STRUCTURAL STEEL. AND STEEL JOIST AND GIRDER ERECTION DRAWINGS. 61G15- 31.005: DESIGN OF STRUCTURES UTUJ71NG PRECAST AND PRESTRESSED CONCRETE ISt 1. STRUCTURAL ENGINEERING DOCUMENTS INDICATE THE CONFIGURATION OF PRECAST AND PRESTRESSED COMPONENTS 2 THE RESPONSIBILITY FOR THE DESIGN OF PRECAST OR PRESTRESSED CONCRETE COMPONENTS OR SYSTEMS UTILIZING THOSE COMPONENTS ARE BEING DELEGATED TO A 'DE'. THE 'DE' SHALL PROVIDE TO THE 'EOR' ALL ENGINEERING DOCUMENTS FOR THE DESIGN AND DETAILING OF THE ABOVE, FOR 'EOR' REVIEW AS AN INDICATION THAT THE INTENT OF THE *EOR' HAS BEEN UNDERSTOOD AND THAT THE SPECIFIED CRITERIA HAVE BEEN USED. STRUCTURAL *DIE' DOCUMENTS SHALL BEAR THE IMPRESSED SEAL AND SIGNATURE OF THE DELEGATED ENGINEER. 5 STRUCTURAL *W DOCUMENTS SHALL INCLUDE COMPONENT DETAILS, CALCULATIONS FABRICATION AND ERECTION DRAWINGS ALL SUCH SUBMITTALS SHALL IDENTIFY THE SPECIFIC PROJECT. THE EFFECTS OF THE PRECAST AND PRESTRESSED CONCRETE MEMBERS ON OTHER PARTS OF THE BUILDING IS THE RESPONSIBILITY OF THE 'EOR' FOR THE STRUCTURE. 4. THE 'DE' SHALL CLEARLY INDICATE ALL THE LOADS REACTIONS ATTACHMENT REQUIREMENTS (TO THE STRUCTURE DESIGN BY THE -EOR -) AND ALL INFORMATION DERIVED FROM THE PRECAST AND PRESTRESSED DESIGN, AFFECTING THE STRUCTURE DESIGNED BY THE 'EOR'. B1G15- 31.006(110DIFlED� DESIGN OF ALUMINUM OR STEEL AWNINGS. CANOPIES, OVERHANGS AND FACADE: 1. THE ARCHITECTURAL/STRUCTURAL DRAWINGS OF- RECORD INDICATE THE ELEMENTS LOCATION, CONFIGURATION. DIMENSIONS GENERAL APPEARANCE AND ELEMENTS OF THE ABOVE TITLES ELEMENTS POSTS, HANGERS BRACKETS SUPPORTING WAITS AND BEAMS ALL DESIGN LOADS ARE ALSO INCLUDED. 2 THE SYSTEM MANUFACTURER 'S/SUPPLIER'S 'DE' SHALL DESIGN THE ENTIRE SYSTEM INCLUDING ALL THE BEAM/JOIST/RAFTER ELEMENTS DECIDING /GRATING /COVERS AND ALL INTERNAL AND EXTERNAL CONNECTIONS (INCLUDING TO THE STRUCTURE) IN ACCORDANCE WITH THE SPECIFICATIONS LOAD TABLES AND COMPUTER DATA TO SUPPORT THE LOADS PER THE 'EOR' SPECIFICATIONS THE 'EOR' REQUESTS THE SUBMISSION OF THE ENTIRE SYSTEM DESIGN CALCULATIONS (FOR EACH COMPONENT AND CONNECTIONS) AS AN INDICATION OF COMPLIANCE THE SYSTEM MANUFACTURER 'S /SUPPLIER'S 'DE' SHALL SUBMIT A COVER LETTER ALONG WITH THE CALCULATIONS. THE COVER LETTER SHALL BEAR THE SEAL AND SIGNATURE OF A FLORIDA PROFESSIONAL ENGINEER RESPONSIBLE FOR THE DESIGN OF THE SYSTEM. FOUNDAiONS (SPREAD FOOTINGS) THESE RECOMMENDATIONS ARE BASED ON SOIL EXPLORATION AND FOUNDATION RECOMMENDATIONS, MADE BY. *AUL STATE ENGINEERING & TESTING CONSULTANTS INC.' (REPORT DATED 1G-8- 2012). IN THE EVENT OF A DISCREPANCY BETWEEN THESE REQUIREMENTS AND THE REQUIREMENTS IN THE GEOTECHNICAL REPORT, THE MORE STRINGENT SHALL BE USED. 1. FOUNDATIONS ARE DESIGNED TO BEAR ON WELL COMPACTED GRADE OR CLEAN FILL PREPARED TO ACHIEVE A MINIMUM ALLOWABLE BEARING CAPACITY OF 2500 PSF A CERTIFIED TESTING LABORATORY SHALL BE ENGAGED BY THE OWNER M VERIFY THAT THE REQUIRED BEARING CAPACITY WAS OBTAINED. SAID SOIL CAPACITY SHALL BE CERTIFIED AND TESTED BY A REGISTERED FOUNDATION ENGINEER. PRIOR TO CASTING OF CONCRETE IN THE FOOTINGS 2 NATURAL GRADE (OR FUR) BELOW FOOTINGS SHALL BE COMPACTED TO A MINIMUM OF 98% MODIFIED PROCTOR (ASTM D- 1557). 5 TOP OF WALL FOOTINGS TO BE AT THE SAME ELEVATION AS TOP OF COLUMN PAD FOOTINGS STEP WALL FOOTING FROM HIGHER COLUMN FOOTING M THE LOWER ONE (AS DETAILED ON THE PLANS). 4. TOP OF ALL FOOTINGS TO BE A MINIMUM 1' -4' BELOW THE TOP OF CONCRETE SLAB ON GRADE (UNLESS OTHERWISE NOTED TO BE AT LOWER ELEVATION OR CAST MONOLITHIC WITH SLAB) OR MINIMUM 1' -0' BELOW FINISHED GRADE, WHICHEVER IS LOWER. IN THE EVENT THAT THE SLAB STEPS ON EACH SIDE OF THE FOOTING, THE FOOTING SHALL BE 1' -4' BELOW TOP OF THE LOWER SLAB. TO ACCOMMODATE A CONTINUOUS WALL FOOTING, A STEPPED FOOTING MAY BE REQUIRED (SEE DETAIL ON PLAN). 5. REINFORCING IN THE CONTINUOUS WALL FOOTINGS (MONOLITHIC AND /OR NON - MONOLITHIC) SHALL BE SPUCED 38 BAR DIAMETERS MINIMUM AND SHALL EXTEND CONTINUOUSLY THRU ALL FOOTING PADS 6. ALL LONGITUDINAL REBARS IN THE CONTINUOUS WALL FOOTINGS SHALL BE CONTINUED AT BENTS AND CORNERS BY BENDING THE REBARS 48 BAR DIAMETERS AROUND THE CORNERS OR ADDING MATCHING CORNER BARS EXTENDING 48 BAR- DIAMETERS INTO FOOTING EACH SIDE OF CORNER OR BENT. 7. ALL FOOTINGS (MONOLITHIC OR NOT) SHALL BE It MINIMUM THICK. CONCRETE NON -STRI IC7URAL 4 ARS ON GRADE - 1. ALL NON- STRUCTURAL CONCRETE SLABS AND WALKWAYS ON GRADE. AS SHOWN ON THE STRUCTURAL AND /OR ARCHITECTURAL PLANS. SHALL BE AS FOLLOWS: INgffi4RSLAB$ 4- THICK, REINF. W/ 64- 1`1.401.4 GALVANIZED WELDED WIRE FABRIC (UNLESS OTHERWISE NOTED). EXTERIOR SLABS AND WALKS 4- THICK, RONF. W/ 8x8- WIAXW1.4 GALVAIZED WELDED WIRE FABRIC (UNLESS OTHERWISE NOTED). INTERIOR DRIVEWAY (C-AR LANE) SL AR-_- 8- THICK, ROW. W/ 8x8- W2.%W29 GALVANIZED WELDED WIRE FABRIC (UNLESS OTHERWISE NOTED). 2 ALL SLABS ON GRADE TO BE CONSTRUCTED IN ACCORDANCE WITH LATEST A0.1 - 'GUIDE FOR CONCRETE FLOOR AND SLAB CONSTRUCTION' (A.CI. - 302.1R). 5 JOINTS SHALL BE PROVIDED IN ALL INTERIOR SLABS ON GRADE AT ALL COLUMN CENTERLINES DIVIDING THE SLAB INTO SQUARE PANELS NOT TO EXCEED 18 X 18 FL IN SIZE (U.O.N.). CAST SLAB IN LONG ALTERNATE STRIPS. PROVIDE A CONTRACTION JOINT BETWEEN EACH STRIP. SEE PLAN FOR SAW -CUT. CONTRACTION AND ISOLATION JOINT DETAILS. 4. PROVIDE SAW -CUT JOINTS AT ALL SIDEWALKS AT A MAXIMUM SPACING OF FIVE FEET ON CENTERS AND ISOLATION JOINTS AT 20 FEET O.C. (U.O.N.)L 5. FILL MATERIAL SHALL BE PLACED IN LIFTS NOT EXCEEDING If AND 6. COMPACTED TO MINIMUM 95XG MODIFIED PROCTOR (ASTM D -1557) WITHIN A DISTANCE OF 3 FEET BEYOND ALL FOOTING EDGES COORDINATE THESE REQUIREMENTS WITH THE GEOTECHNICAL REPORT AND RECOMMENDATIONS TAKE AT LEAST ONE DENSITY TEST FOR EACH 2,500 SOFT. OF AREA AND 12' BELOW SURFACE SEND RESULTS OF THE TEST TO OWNER. ARCHITECT AND ENGINEER 1. CONCRETE DESIGN AND REINFORCEMENT IN ACCORDANCE WITH 'BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE' (A.CI 318) AND WITH 'DETAILS AND DETAILING OF CONCRETE REINFORCEMENT--(A.C.I 315 - LATEST EDITION 2 ALL CONCRETE WORK IN ACCORDANCE WITH 'SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDING- (A.CI. 301). PRODUCTION OF CONCRETE, DELIVERY, PLACING AND CURING TO BE IN ACCORDANCE WITH 'HOT WEATHER CONCRETING' (A.C.L 305R)L 5 ALL REINFORCING TO BE NEW BILLET STEEL CONFORMING TO THE LATEST A.&T.M. A -615 GRADE 60, FABRICATED IN ACCORDANCE WITH C.R.S.L MANUAL OF STANDARD PRACTICE AND PLACED W ACCORDANCE WITH A.C.I. 315 AND C.R.S.L MANUAL OF STANDARD PRACTICE. 4. ALL REINFORCING SHALL BE DEFORMED BARS, CLEAN OF OIL. SCALE AND RUST. 5 • DOWELS TO BE SAME SIZE AND NUMBER AS VERTICAL REBARS ABOVE LAP 36 BAR DIAMETER OR MINIMUM OF 18 INCHES U.O.N. PROVIDE RIGID TEMPLATES FOR COLUMN DOWEL LOCATION. PROVIDE STANDARD HOOKS AT TOP OF ALL VERTICAL REINFORCEMENT AT NON - CONTINUOUS COLUMNS (U.O.N.). 5.1 ADD 2 SETS OF TIES (SPACED AT 3' O.C. MAX) BELOW THE 'OFFSET -BENT- IN THE VERTICAL ROARS AT THE LAP LOCATION WITH THE CAGE ABOVE. TIE - COLUMNS (CONSTRUCTED WITH NO 'OFFSET -BENT' DO NOT REQUIRED ADDED TES). 5.2 UNLESS OTHERWISE INDICATED ALL COLUMNS SHALL BE EXTENDED TO THE TOP OF THE ROOF PARAPET. 5.3 ALL DOWELS FOR COLUMNS SHALL BE SECURED IN POSITION PRIOR TO CONCRETING. PUSHING THE DOWELS INTO POSITION IN WET CONCRETE IS NOT PERMITTED. 6, REAM REINFORCEMENT: LAPPED 36 BAR DIAMETER OR MINIMUM 18 INCHES (SEE BEAM DIAGRAM ON PLAN). BOTTOM BARS SPUCED ONLY AT SUPPORTS TOP BARS SPUCED ONLY AT MID -SPAN. ALL TOP BARS HOOKED AT NON - CONTINUOUS EDGES (U.O.N.). ALL HOOKS TO BE STANDARD 90 OR 180 DEGREE HOOKS AS REQUIRED (U.O.N.). TIES OR STIRRUPS SHALL BE SPACED AS INDICATED ON THE BEAM SCHEDULE, MEASURED FROM SUPPORT TO SUPPORT (U.OA)L EXAMPLE 406' MG E.E BAL Olt 0.G, MEANS 4 TIES AT 6' O.C. AT EACH END OF EACH SPAN, WITH TES AT 12' O.C. IN THE MIDDLE (BETWEEN THE TWO END SUPPORTS). CONTACT ENGINEER IF THIS REQUIRE FURTHER CLARIFICATIONS. 7. ADDED REINFORCEMENT: PROVIDE ADDITIONAL CORNER BARS BENT 38 INCHES MINIMUM EACH WAY AT V AND 'T' CORNERS IN OUTER FACES OF ALL BEAMS TO MATCH ALL HORIZONTAL BAR (TOP, BOTTOM AND INTERMEDIATE REBARS). & UNLESS OTHERWISE SPECIFICALLY INDICATED ON THE PLANS OR DETAILS, ALL REM END HOOKS SHOWN OR REQUIRED AT ALL TYPES OF REINFORCED CONCRETE ELEMENTS SHALL BE THE ACI STANDARD LENGTH FOR 90 OR 180 DEGREES HOOKS SLAB TEMPERATURE REINFORCING ALL SLABS SHALL HAVE TEMPERATURE REINFORCING PERPENDICULAR TO THE DIRECTION OF THE MAIN REBARS (U.ON. ON PLANS). TEMPERATURE REINFORCING TO BE AT MINIMUM 04 AT 12. O.C. IN SLABS UP TO 8' THICK. 9. CONCRETE TIE BEAM: A MINIMUM CONCRETE TE BEAM (AS SPECIFIED HEREIN) SHALL BE PROVIDED AT EACH FLOOR OR ROOF LEVEL. IF A BEAM WAS NOT CALLED FOR ON THE PLANS THE TIE BEAM SHALL BE A MINIMUM OF 8' X 12', REINFORCED WITH (2) -05 TOP AND BOTTOM AND 03 TIES, (4) AT It O.C. EACH END, BALANCE AT 48' 0.C.. DROP BOTTOM OF THE BEAM OVER OPENINGS ADD (2)-#5 BOTTOM AND 03 TIES AT 6' O.C. THRUOUT. THESE BEAMS ARE NOT IN ADDITION TO BEAMS ALREADY INDICATED AND SCHEDULED ON THE PLANS FOR THE SAME LOCATION. 10. CURING & PROTECTION: ALL STRUCTURAL SLABS AND SLABS -ON -GRADE SHALL BE CURED WITH MOIST BURLAP COVER (KEPT MOIST FOR 7 DAYS). SPRAY ON CURING COMPOUNDS (INCLUDING CURING/SEALERS/HARDENERS) MAY BE CONSIDERED. CONTRACTOR TO SUBMIT TO ARCHITECT/ENGINEER MATERIAL SPECIFICATIONS AND DATA, FOR REVIEW AND ACCEPTANCE PRIOR TO APPLICATION. NO SLAB CONCRETE SHALL BE LET TO DRY WITHOUT ANY CURING. 11. CONCRETE COVER (UNLESS OTHERWISE DETAILED ON DRAWINGS} ELEMENT' CONCRETE COVER: TOP BOTTOM SIDES REMARKS- WALL & COLUMN PAD FOOTING 2 3 4 NON- STRUCT. SLAB -ON -GRADE MID -DEPTH 5 BEAMS/COLUMNS TO TIES 1 -1 2 ALL AROUND (6) - 07 ELEVATED SLABS INTERIOR 1 1 - 1 15 ELEVATED SLABS EXTERIOR 0-1/2- 11-I g2 UP TO N0. 5 BARS ELEVATED SLABS EXTERIOR 2 2 NO. 6 AND LARGER BARS 12 ALL CONCRETE TO BE REGULAR WEIGHT WITH A DESIGN STRENGTH AS FOLLOWS: ELEMENT: AT 28 DAYS STRENGTH: MAX SLUMP: ALL CONC. BEAUS & SLABS 4,000 PSI 4 FOOTINGS 4,000 PSI 5 CONCRETE COLUMNS SEE COLUMN SCHEDULE RFQUREIMEINTS FOR SPECIAL EXPOSURE CONDITIONS (ACI -318. SECTION 4.2 TABLE 4.2.2k A TESTING LABORATORY SHALL BE ENGAGED TO TAKE SOIL SAMPLES TEST AND REPORT THE CALCIUM AND SULFATE CONTENTS IN THE SOIL TO BE IN CONTACT WITH THE NEW CONCRETE IF FOUND EXCEEDING ACI-318 MINIMUM ALLOWED, ALL CONCRETE PLACED IN CONTACT WITH THE GROUND EXPOSED TO SALT WATER, SEAWATER OR SPRAY FROM THESE SOURCES SHALL HAVE A MAXIMUM WATER /CEMENT RATIO OF 0.40, IN ADDITION TO STRENGTH AND SLUMP REQUIREMENTS INDICATED ABOVE NOTE: THE PIES SHALL BE DRIVEN INTO GROUND FIRST, BEFORE ANY COMPACTICN WORK AND EXCAVATION FOR THE SHALLOW SPREAD FOOTING. COORDINATE WORK AND SEQUENCE WITH THE GEOTECHNICAL ENCINNER. ill 1.1 FURNISH ALL LABOR, MATERIALS, EQUIPMENT, INCIDENTALS, TRANSPORTATION, ERECTION/INSTALLATION AND SUPERVISION NECESSARY TO COMPLETE ALL PILING AND RELATED WORK CALLED FOR ON THE PLANS OR HERON OR REASONABLY INFERABLE FROM OTHER OR BOTH, INCLUDING BUT NOT LIMITED TO THE FOLLOWING (A) AUGERED-CAST GROUTED PILES. (8) ACCURATE LAYOUT AND INSTALLATION OF ALL PILES. (C) RECORDS 1.2 FOUNDATION CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH THE NATURE OF THE PROJECT. EXISTING ON -SITE AND ADJACENT UTILITIES AND POTENTIAL HAZARDS AND TAKE WHATEVER PRECAUTIONS NECESSARY TO PROTECT THE OWNER FROM ANY DAMAGE OR LIABILITY. F REQUESTED BY THE OWNER, A VISUAL INSPECTION OF ANY NEARBY STRUCTURES SHALL BE PERFORMED BY A REGISTERED STRUCTURAL ENGINEER PRIOR TO FOUNDATION CONSTRUCTION. ALL DUSTING CRACKS DAMAGES OR POTENTIALLY HAZARDOUS CONDITIONS SHALL BE NOTED, DOCUMENTED AND REPORTED PRIOR TO PILE INSTALLATION. 2 TYPE OF PILES THE PILES SHALL BE AUGER -CAST TYPE PUB, AS LISTED BELOW. ALL PIES SHALL BE DRIVEN TO A PROPOSED DEPTH OF 45 FT. AS INDICATED IN THE SOIL REPORT AND AS RECCOMENDED BY THE GEOTECHNICAL ENGINEER. TO DEVELOP THE SPECIFIED PILE CAPACITY NOMINAL DIAMETER INCHES GROUT STRENGTH AT 28 DAYS GRAVITY LOAD CAPACITY -1 BUS ,59 ON SON FULL LENGTH OF PILE COMP. TONS TENSION TONS 18 4,000 PS (6) - 07 1 (1) - j9 I 'm 1 15 5 VERTICAL REINFORCING AND TIES- FOR VERTICAL REINFORCING - SEE TABLE ABOVE. TIES SHALL BE ROUND 03 TIES SPACED AT 12' O.C. THR UOUT THE ENTIRE LENGTH OF THE REINFORCING CAGE COMPRESSION REINFORCING CAGE TO EXTEND A MINIMUM OF 25 FT. INTP PIES AND PROJECT 20' INTO THE PILE -CAP. TENSION REBAR TO BE CENTERED WITH PILE, FULL LENGTH OF PILE AND HOOKED INTO GRADE- BEAM/PILE -CAP, AS DETAILED. 4. EDPEBIENL2 ; SUBMIT EVIDENCE THAT THE AUGERED GROUT PILE CONTRACTOR HAS BEEN ENGAGED IN THE SUCCESSFUL INSTALLATION OF AUGERED GROUT INJECTED PILES FOR AT LEAST 5 YEARS AND THAT HIS CRANE OPERATORS OR KEYMAN WHO GIVE DIRECTIONS TO THE CRANE OPERATORS, HAVE AT LEAST 2 YEARS OF EXPERIENCE IN THE SUCCESSFUL INSTALLATION OF SAID PILE SYSTEM. 5. PILES NOT INSTALLED IN ACCORDANCE WITH ACCEPTED PROCEDURES SHALL BE REJECTED AND ADDITIONAL PILES SHALL BE INSTALLED AS DIRECTED BY FOUNDATION ENGINEER. 6. LOCATION OF PUJ S PILES SHALL BE LOCATED AS SHOWN ON PLANS OR AS DIRECTED BY ENGINEER. PIE CENTERS SHALL BE MARKED ON STE TO AN ACCURACY OF ( + / -) ONE INCH. 7. TOLERAN PILES SHALL BE INSTALLED WITHIN 3 INCHES OF PLAN POSITION. & INSPECTIONS THE OWNER WILL RETAIN THE SERVICES OF A STATE REGISTERED ENGINEER QUALIFIED AS A SOIL AND FOUNDATION ENGINEER TO CONDUCT FULL TIME OBSERVATIONS (- SPECIAL INSPECTIONS-) DURING THE INSTALLATION OF THE PILES. THE INSPECTOR ENGINEER WILL BE EMPLOYED TO REPRESENT THE INTERESTS OF THE OWNER AND AID THE CONTRACTOR WHEN NECESSARY. THE ENGINEER SHALL MAINTAIN A SEPARATE LOG OF EACH PILE AND ISSUE A PILE- STATEMENT AT THE COMPLETION OF THE PILE DRIVING WORK, AS TO THE PIES COMPLIANCE WITH SZE. LENGTH, REINFORCING AND REQUIRED LOAD CAPACITY. CONCRETE TESTIN 1. CONCRETE SHALL BE TESTED FOR STRENGTH. MINIMUM OF 4 CYLINDERS SHALL BE MADE FOR EACH 50 CUNDS. OF CONCRETE (OR AT LEAST ONE PER DAY, IF LESS THAT 50 CU.YDS.). TEST IN ACCORDANCE WITH ASTM C -39. SUBMIT ALL TEST RESULTS IN A TIMELY MANNER, TO THE A/E FOR REVIEW. 1.1 TESTING AGENCY WILL BE SELECTED AND PAID FOR BY THE OWNER TESTS AND INSPECTIONS UNDER DIRECT CONTROL OF THE OWNER. RESULTS OF ALL TESTS SHALL BE SENT TO THE OWNER, OWNER'S REPRESENTATIVES AND THE CONTRACTOR. CONTRACTOR SHALL NOTIFY LABORATORY AT LEAST TWENTY FOUR (24) HOURS BffORE EACH SCHEDULED CONCRETE PLACING. 11 MAKE ONE SET OF FOUR (4) CYLINDERS AND ONE (1) SLUMP TEST FOR THE FOLLOWING 12A. EACH CLASS OF CONCRETE PLACED EACH DAY, NOT LESS THAN ONCE A DAY. 1.2.B. NOT LESS THAN ONCE FOR EACH 50 CUBIC YARDS OF CONCRETE OR PORTIONS THEREOF. 1.2C. NOT LESS THAN ONCE FOR EACH 5,000 SQUARE FEET OF SURFACE AREA FOR SLABS 1.3 SAMPLES FOR THE TESTS SHALL BE OBTAINED FROM A DIFFERENT BATCH OF CONCRETE SELECTED ON A RANDOM BASIS TAKEN AT 1/4 AND 3/4 POINTS OF THE LOAD IN MIXER. 1.4 TEST ONE (1) CYLINDER AT SEVER (7) DAYS AND TWO (2) AT TWENTY EIGHT (28) DAYS. HOLD ONE (1) CYLINDER FOR TESTING AT FORTY -FIVE (45) DAYS IF THE 28 DAYS TESTS FAIL TO MEET SPECIFIED STRENGTH. ADDITIONAL CYLINDER TESTS THAT MAY BE REQUIRED BY THE CONTRACTOR (FOR FORMS AND SHORING REMOVAL) SHALL BE ORDERED AND PAID FOR BY THE CONTRACTOR. 2 EVALUATION AND ACCEPTANCE OF CONCRETE 21 IN THE EVENT THAT THE CONCRETE SLUMP AND /OR CONCRETE HAD EXCEEDED THE SPECIFIED DEPOSIT TIME. THE ON -SITE TESTING LAB TECHNICIAN SHALL IMMEDIATELY NOTIFY THE CONTRACTOR'S ON -SITE REPRESENTATIVE WHO SHALL REJECT THE NON - COMPLYING CONCRETE 2.2 IF CONCRETE TESTS ARE INSUFFICIENT OR INADEQUATE, IN PLACE CONCRETE SHALL BE TESTED AND EVALUATED BY CORE TESTS USE OF ONLY THE 'SWISS- HAAMAMOr OR 'WINDSOR PROBE' ARE NOT ACCEPTABLE WITHOUT THE ADDED CORE TESTING FOR COMPARATIVE RESULTS FAILURE OF ANY CONCRETE TO MEET SPECIFIED REQUIREMENTS SHALL BE DEEMED NON - COMPLYING AND COSTS OF ADDITIONAL TESTS TO DETERMINE ADEQUACY OR INADEQUACY SHALL BE BORNE BY THE CONTRACTOR 23 CONCRETE REJECTED FOR ANY REASON SHALL BE REMOVED AND REPLACED. LABOR, NEW FORMS AND REINFORCING REQUIRED TO MEET SPECIFICATIONS SHALL BE PROVIDED BY THE CONTRACTOR, AT NO ADDITIONAL COST TO OWNER AND AT NO TIME EXTENSION TO THE PROJECT. PRECAST CONCRETE UNITS - GENERAL REQUIREMENTS- 1. ALL PRECAST UNITS (INDIVIDUAL UNITS OR SYSTEMS) SHALL BE DESIGNED BY THE CONTRACTOR'S OR THE PRECAST MANUFACTURER'S DELEGATED STRUCTURAL ENGINEER THE DELEGATED ENGINEER SHALL BE A FLORIDA LICENSED ENGINEiIR. HAVING A MINIMUM OF THREE (3) YEARS OF EXPERIENCE IN THE DESIGN OF THE PARTICULAR ELEMENT(S). 2 SUBMIT SHOP DRAWINGS ALL CALCULATIONS AND COMPUTER PRINTOUTS PREPARED BY AND SIGNED AND SEALED BY THE DELEGATED STRUCTURAL ENGINEER. COMPUTATIONS SHALL BE MADE FOR EACH MEMBER AND FOR THE SYSTEM (AS APPLICABLE). ENCLOSE A LEGEND OR A DESCRIPTION OF ALL ABBREVIATIONS AND NOMENCLATURES, USED IN THE CALCULATIONS AND COMPUTER INPUT /OUTPUT. 3. PRESTRESSED UNITS SHALL BE DESIGNED AND MANUFACTURED IN ACCORDANCE WITH THE REQUIREMENTS OF THE BUILDING CODE, P.C.. MANUAL AND A.C.I. CODE MEMBERS SHALL BE DESIGNED TO CARRY OWN WEIGHT AND ALL SUPERIMPOSED DEAD LOADS PLUS LIVE LOADS. ALL MEMBERS SHALL ALSO BE DESIGNED M CARRY ALL EXPECTED CONSTRUCTION PHASE LOADS 4. SHOP DRAWINGS SHALL SHOW AND SPECIFY CONCRETE TYPE AND STRENGTH, REINFORCING (REBARS AND CABLES), ANCHORAGE, STEEL INSERTS, CONCRETE COVERS CABLE DEPRESSIONS BEARING DIMENSIONS PLAN LAYOUT AND LOCATION OF EACH PRECAST MEMBER, CONNECTION TO OTHER STRUCTURES AND SUPPORTS, ALL PENETRATIONS (AS REQUIRED BY OTHER TRADES) LOAD TRANSFERRING COMPONENTS DESIGN .DADS AND OTHER RELATED INFORMATION ALSO SHOW ON THE STRUCTURAL PLANS 5. ALL LOADS AND REACTIONS APPUED BY THE PRECAST ELEMENTS ONTO THE SUPPORTING STRUCTURE SHALL BE CLEARLY INDICATED ON THE SHOP DRAWINGS. IF REQUIRED, THE ENGINEER -OF- RECORD SHALL ADJUST THE MAIN STRUCTURE TO SUPPORT SAID LOADS. S. DELEGATED ENGINEER SHALL ALSO DESIGN AND INDICATE ON THE SHOP DRAWINGS. ALL TEMPORARY SHORING, TEMPORARY ATTACHMENTS, FORMWORK, BRACING AND RESHORES (INCLUDING 71ME FOR REMOVAL AND /OR THE SYSTEM. S REQUIRED FOR SAFE ERECTION OF THE PR 7. NO FABRICATION OF PRECAST COMPONENTS SHALL BEGIN, UNTiL ALL SHOP DRAWINGS AND CALCULATIONS HAVE BEEN REVIEWED BY THE ENGINEER-OF-RECORD AND THE ARCHITECT. & ALL METAL CONNECTIONS SHALL BE RUST -PROOF PAINTED. ALL FIELD WELDS SHALL BE WIRE - BRUSHED CLEAN AND RUST -PROOF PAINTED. TOUCH UP WITH RUST -PROOF PAINT ALL COATED STEEL WITH PAINT DAMAGED DURING TRANSPORTATION, ERECTION OR ADJACENT WELDING OPERATIONS ALL WED SHALL BE INSPECTED BY A CERTIFIED WELDING INSPECTOR 9. PRECAST UNITS PLACED IN STRUCTURES LOCATED IN CORROSIVE ATMOSPHERES (SUCH AS EASTWARD OF THE COASTAL BUILDING CONSTRUCTION LINE) SHALL HAVE COATED REINFORCING OR SPECIALLY DESIGNED CONCRETE MIX 10. ALL PRECAST COMPONENTS, SHALL BE INSPECTED FOR QUALITY CONTROL. BY THE DELEGATED ENGINEER, PRIOR TO CASTING OF CONCRETE AT THE CASTING YARD. A COMPLETE RECORD SET OF MATERIAL, STRESSING AND CONCRETE TESTING SHALL BE PROVIDED M THE DELEGATED ENGINEER AND THE ENNEEER- OF- RECDRD. THESE TESTS SHALL BE AVAILABLE TO THE BUILDING OFFICIAL DURING HIS INSPECTIONS AND FOR 7 YEARS AFTER COMPLETION OF THE PROJECT. 11. CONTRACTOR TO NOTE THAT ALL PRECAST- PRESTRESSES BEAU OR JOIST E EM IS WILL HAVE A CAMBER. THE EXTENT OF SUCH CAMBER MAY BE CONTROLLED BY THE ELEMENT DESIGNER (TO A CERTAIN DEGREE) BUT CANNOT BE ASSURED. WHERE DIFFERENT BUILDING ITEMS ARE TO BE CONNECTED TO SUCH PRECAST ELEMENTS AND MAY BE AFFECTED BY THE DEGREE OF THE CAMBER, THE CONTRACTOR SHALL COORDINATE THE CAMBERS WITH THE PC DESIGNER/MANUFACTURER TO MINIMIZE POTENTIAL UNEXPECTED CAMBERS AND ALLOW FOR ADDITIONAL SHIMS SPACERS. BUCKS ETC. (INCLUDING LABOR) TO ACCOMMODATE CAMBERS WHEN IT BECOMES NECESSARY. 12 PRECAST CONCRETE SLAB UNITS SHALL HAVE MINIMAL CAMBER DIFFERENCES BETWEEN ADJACENT UNITS AND BETWEEN A P.C. UNIT AND A CAST -IN-PLACE BEAM. 15 FIRE RATING COMPLY WITH FIRE RATING REQUIREMENTS AS INDICATED HEREIN OR ON THE ARCHITECTURAL PLANS IF FIRE RATING INFORMATION HAS NOT BEEN INCLUDED, CONTACT ARCHITECT/ENGINEER FOR INFORMATION, BEFORE PROCEEDING WITH ENGINEERING AND SHOP DRAWING PREPARATION. 14. 'SPECIAL INSPECTION SERVICES ARE REQUIRED FOR THIS TYPE OF STRUCTURE IN MIAMI -DADE AND BROWARD COUNTIES IN ADDITION TO THE INSPECTIONS PROVIDED BY THE LOCAL BUILDING DEPARTMENT. SEE 'SPECIAL INSPECTION REQUIREMENTS- SECTION IN THESE GENERAL NOTES. CONTACT A/E FOR ANY REQUIRED INFORMATION AND /OR QUESTIONS COMPOSITE PRESTRESSED PRECAST JOISTS AND CAST -IN -PLACE SLAB:. 1. PRESTRESSED PRECAST JOISTS DEPTH AS INDICATED ON THE PLANS (U.O.N INDICATED ON THE SHOP DRAWINGS). SPACED AS INDICATED ON THE PLANS OR AS REQUIRED BY CALCULATIONS CAST -IN -PLACE COMPOSITE SLAB SHALL BE A MINIMUM OF 4-3/4' THICI(, REINFORCED WITH 04'S AT 12 INCHES ON CENTER EACH WAY (CENTERED WITH THE SLAB SEE PLANS FOR ADDITIONAL REBARS OVER BEMIS AND AT CORNERS 2 COPE TOP OF JOISTS AT SUPPORTS TO PROVIDE CLEARANCE FOR BEAMS' TOP REINFORCEMENT AS REQUIRED. PROVIDE OTHER APPLICABLE PC JOISTS CONNECTORS AS MAY BE NECESSARY TO CLEAR CONGESTED REINFORCING OR OTHER CONDITIONS 3. IN THE EVENT THAT THE BOTTOM OF THE JOIST IS AT A DISTANCE OF 4' OR LESS FROM THE BOTTOM OF THE SUPPORTING BEAM. THE JOISTS DESIGNER SHALL PROVIDE A BOTTOM NOTCH AT EACH SUCH JOIST. (BOTTOM NOTCHED JOISTS MAY ALSO BE REQUIRED ELSEWHERE ON THE PLANS - SEE SECTIONS AND ENGINEERED SHOP DRAWINGS). 4. MINIMUM CONCRETE STRENGTH OF THE PRECAST JOISTS IS F'c - 5,000 PSI AND THE CAST -IN-PLACE SLAB rc - 5,000 P.SI. 5. MINIMUM BEARING OF THE JOIST ONTO THE SUPPORTING BEAMS IS 4'. 8. THE PROJECT REQUIRE 16' OR 24' WIDE COMPOSITE PC BEAM SOFFITS WITH CAST -IN- PLACE CONCRETE ON TOP - SEE BEAM SCHEDULE FOR CALCULATED ULTIMATE MOMENTS AND SHEAR (TO BE USED BY THE COMPOSITE PC BEAN DESGNER)L 7. PC COMPOSITE BEAM DESIGNER SHALL DESIGN THE PC SOFFIT FOR THE PROVIDED MOMENTS AND DESIGN THE STIRRUPS (OR TIES) FOR A COMBINED SHEAR AND TORSION (AS APPLICABLE). B. SEE STRUCTURAL PLANS OR SCHEDULE FOR 'SHEAR- FRICTION' REINFORCING. UNLESS OTHERWISE SPECIFIED, MINIMUM SHEAR - FRICTION REINFORCING SHALL BE NO LESS THAN (5 )-06'S (10' LONG STRAIGHT BARS OR 6' LONG W/HOOK AT END COLUMNS). O. REQUIRED SYSTEM FIRE RATING IS ONE (1) OR TWO (2) HOURS MINIMUM (UNLESS OTHERWISE NOTED) - SEE ARCHITECTURAL DOCUMENTS FOR ALL FIRE RATING NON - REINFORCED LOAD BEARING MASONRY WALLS 1. HOLLOW LOAD- BEARING MASONRY UNITS SHALL CONFORM TO ASTM C -90. TYPE I, REGULAR WEIGHT, WITH A MINIMUM DESIGN COMPRESSIVE STRENGTH ON NET OF F'm =1,900 PS. ALL BLOCKS SHALL BE 2 HOUR MINIMUM FIRE RATED BLOCK CONSTRUCTION SHALL BE IN ACCORDANCE WITH LATEST ACI-530 SPECIFICATIONS 2 MORTAR SHALL CONFORM TO ASTM C-270, TYPE 'MP OR V. 5 LAY ALL MASONRY WITH FULL FACE HEAD JOINTS AND WITH FACE SHELL MORTAR BEDDING. 4. CONCRETE IN TIE COLUMNS AND TIE BEAMS SHALL BE PLACED AGAINST IN -PLACE MASONRY. 5. HORIZONTAL REINFORCING PROVIDE GALVANIZED 09 GAGE WIRE, TRUSS TYPE, HORIZONTAL JOINT REINFORCING EVERY 2ND BLOCK COURSE (1' -4' O.C. VERTICALLY) LAPPED 7 -1/Y AND EXTENDED r INTO CONCRETE COLUMNS PROVIDE SPECIAL HORIZONTAL REINFORCING AT 'T' AND 'L' INTERSECTION. PROVIDE 'DOVE -TAIL' ANCHORS AT 16' O.C. VERTICALLY FOR ALL MASONRY PLACED ADJACENT TO ALREADY IN PLACE COLUMNS & CONCRETE TIE COLUMNS ARE REQUIRED AT i6 FT. ON CENTERS MAXIMUM (SMALLER SPACING MAY BE REQUIRED TO LIMIT THE MASONRY PANEL AREA TO 240 SQ.FT.) OR AS REQUIRED BY DESIGN), AT EVERY CORNER OR CHANCE OF WALL DIRECTION, ON EACH SEE OF OPENINGS LARGER THAN 8 FT., ADJACENT TO ANY CORNER OPENING LARGER THAN 4 FT„ AT GABLE AND SHED END CORNERS AND AT FREE STANDING OF WALLS EXCEEDING 2 FT- ALL TIE COLUMNS AND COLUMNS SHALL BE EXTENDED TO THE TOP OF THE ROOF PARAPET WALL (UNLESS OTHERWISE INDICATED ON THE PLANS OR DETAILS). 7. IN THE EVENT OF DISCREPANCY BETWEEN THESE REQUIREMENTS AND THE COLUMNS INDICATED ON THE PLANS THE MORE STRINGENT REQUIREMENT OR CONDITION SHALL BE USED. & ANY MASONRY OPENINGS BETWEEN 3 AND 8 FT. IN WIDTH SHALL HAVE ONE 05 VERTICAL REBAR ON EACH SIDE, PLACED IN BLOCK CELL FILLED WITH CONCRETE THESE REBARS SHALL BE HOOKED AT THE FOUNDATION AND AT THE TIE BEAM AND LAPPED 30' MINIMUM. 9. SEE SECTION 'CONCRETE AND RONFOROW FOR MINIMUM TIE BEAMS WHERE OTHER BEAMS ARE NOT OTHERWISE INDICATED ON PLANS 10. IN COMPLIANCE WITH 'OSHA' REQUIREMENTS (29 CM 1926.706(b)) WALLS HIGHER THAN 8 FT. SHALL BE LATERALLY BRACED DURING CONSTRUCTION. BRACING SHALL REMAIN IN PLACE TILL THE ROOF AND /OR FLOOR STRUCTURES HAVE BEEN SECURED TO PROVIDE THE REQUIRED PERMANENT BRACING. CONTRACTOR SHALL PROVIDE LATERAL BRACING SHOP DRAWINGS OR DATA SHEETS, DESIGNED, SIGNED AND SEALED BY A FLORIDA REGISTERED STRUCTURAL ENGINEER. 1NTELS OVER MASONRY WALL OPENINGS I. THE CONTRACTOR SHALL PROVIDE PRECAST CONCRETE OR CAST-IN-PLACE LINTELS AT THE HEADS OF ALL OPENINGS IN MASONRY WALLS NOT EXCEEDING SEVEN (7) FEET IN MOTH MERE BEAMS/LINTELS HAVE NOT BEEN OTHERWISE SPECIFIED ON PLANS/DETAILS OR SCHEDULED. L THE LINTEL GUIDE SPECIFIED HERE IS FOR LINTELS SUBJECTED TO DOWNWARD ;GRAVITY) ROOF AND FLOOR LOADS, EVENLY DISTRIBUTED OVER THE ENTIRE SPAN OF THE .INTEL SPECIAL LOADING CONDITIONS, SUCH AS WIND NET UPLIFT OR CONCENTRATED .DADS. AND LINTEL SPANS EXCEEDING THE INDICATED ABOVE, ARE NOT COVERED BY THESE VOTES (SEE PLANS AND SCHEDULES FOR SPECIFIC BEAMS AT THESE LOCATIONS). 1 CONTRACTOR SHALL NOTIFY THE A/E OF HIS CHOICE OF CAST IN PLACE LINTELS„ ?RECAST LINTELS OR A COMBINATION THEREOF, TO BE USED BY HIM IN THIS PROJECT. 4. LINTELS BERING ONTO CAST -IN -PLACE CONCRETE COLUMNS (ON ONE OR BOTH ENDS SHALL BE CAST -IN -PLACE TYPE (NOT PRECAST). S. ALL LINTELS SHALL BE BEARING AT LEAST 8' ONTO THE SUPPORTS ON EACIH SIDE OF THE OPENING. S. LINTEL OPTION 61: LINTEL CAST TOGETHER WITH THE BEAM OR TIE BEAM. UNTEL MAY BE CAST INTEGRAL WITH THE STRUCTURAL OR TIE BEAM WHEN HEAD OF THE DPENING IS 24 INCHES OR LESS BELOW. CONTINUE BEAN'S TYPICAL TOP AND BOTTOM REBARS THROUGH AND ADD 2 -#5 BOTTOM BARS AT DROPS AND 3-03 STIRRUPS AT 6' D.C. EACH END OVER OPENING. SHOULD THE CONTRACTOR WISH i0 CAST DEEPER BEAM DROPS (USED FOR LINTELS) HE SHOULD CONSULT WITH THE A/E REGARDING ADDITIONAL (OR DIFFERENT) VERTICAL AND HORIZONTAL REINFORCEMENT. 7. LINTEL OPTION JM CAST -IN -PLACE UNTES (SEPARATED FROM TIE BEAMS ABOVE). CAST-114-PLACE UNTELS SHALL BE A MINIMUM OF 8-X12' CONCRETE REINFORCED WITH 2 -05 TOP AND BOTTOM, AND 3-03 STIRRUPS AT 4 O.C. EACH END, BALANCE AT It O.C.. SEE "CONCRETE! SECTION FOR ARCKED BOTTOM CAST -IN-PLACE CONCRETE LINTEL NOTES & LINTEL OPTION /3: PRECAST U - UNTELS LINTEL INFORMATION PROVIDED HERE IS BASED ON THE LINTELS PRODUCED BY 'CASTCRETr AND ON THEIR ALLOWABLE LOADING TABLE. CONTRACTOR TO SUBMIT LINTEL SPECIFICATIONS AND LOADING DATA IF HE IS USING LINTELS MANUFACTURED BY OTHER THAN 'CASTCRETE'. ALL LINTEL BOTTOMS SHALL BE 8- PRECAST U' SHAPED. FILLED SOLD WITH CONCRETE. LINTELS THAT REQUIRE REINFORCING WITH A HORIZONTAL #5 REBAR ARE SPECIALLY MARKED. 9. I iHM %HMUI Fe (BASED ON 'CAST - CRETE' DATA - NOA 003- 065M05) CLEAR SPAN -CASTCRETE- DESIGNATION GRAVITY LOAD CAPACITY -1 BUS ,59 ZONE - BF8-08 1,969 T30 BFB-1B 189 4' -0' TO 5'-6' Me 1,082 8F8-OB 1,105 O 8FB-1B I 1,451 5' -8' TO 6' -10' BU8 743 122 8FB-08 I 1,011 8F8-1B 1 011 STRUCTURAL (SHOP DRAWINGS REQUIRED) 1. ALL STRUCTURAL STEEL TO BE DOMESTIC A.ST.M. A -36 (Fy-36 KS..) AND DESIGNED IN ACCORDANCE WITH AI.SC. 'SPECIFICATION FOR THE DESIGN. FABRICATION AND ERECTION OF STRUCTURAL STEEL. FOR BUILDINGS' AND THE A.LS.Q CODE OF STANDARD PRACTICE 2 STEEL TUBES TO BE DOMESTIC STEEL CONFORMING TO A.S.M. A -500 GRADE B (FY-46 K.SI.). 5 SEE ARCIITECTURAL DOCUMENTS FOR FURS RATING REQUIREMENTS. 4. ALL COLUMN BASE AND CAP PLATES SHALL BE 3/4' THICK (UNLESS OTHERWISE NOTED). WIDTH AND LENGTH AS REQUIRED FOR PROPER BOLTING AND AS INDICATED ON THE PLANS AND DETAILS. 5. ALL STEEL SHALL BE SHOP PAINTED WITH AN APPROVED PRUDE COAT. STEEL EXPOSED TO THE ELEMENTS OR ANY STEEL IN STRUCTURES CLOSE TO THE OCEAN, SHALL BE EPDXY PAINTED. SEE ARCHITECTURAL DRAWINGS FOR FINISH PAINT INFORMATION. ALL DAMAGES TO THE PAINT ON SITE OR DURING DELIVERY (INCLUDING DRILLING AND WELDING OPERATIONS) SHALL BE FIELD TOUCIHFD -UP WITH THE SAME SPECIFIED RUSTPROOFlNG PAINT. & ALL WIELDING TO BE IN ACCORDANCE WITH AM.& 'STRUCTURAL WELDING CODE - STEEL•. ALL VELDERS TO BE A.W.S. CERTIFIED (CERTIFICATION TO BE AVAILABLE ON -STE DURING WELDING INSPECTION). ALL WELDS TO BE FILLET OR PENETRATION WEDS (THICKNESS TO BE IN ACCORDANCE WITH BASE METAL THICKNESS USE MINIMUM E70XX ELECTRODES. CLEAN AND RUSTPROOF ALL FIELD WELDS WITH HEAVY DUTY RUSTPROOFING PAINT. 7. ALL CONNECTIONS TO BE SHOP WELDED AND /OR FIELD WELDED. UNLESS OTHERWISE SPECIFICALLY INDICATED ON PLANS AND DETAILS, ALL WEDS SHALL BE CONSIDERED FULL WEDS (ALONG THE CONTACT LENGTHS OF THE CONNECTING STEEL ELEMENTS). BOLTED CONNECTIONS MAY BE USED AS DIRECTED. WHERE SPECIFIED ON PLANS AND DETAILS, BOLTS SHALL BE A325 STEEL (U.O.N.� & ALL ANCHOR J -BOLTS (WHERE SPECIFIED FOR COLUMN AND BEAM CONNECTIONS INTO CONCRETE) SHALL BE GALVANIZED AND HAVE A 4- MINIMUM HOOKED END (U.O.N.). 9. UNLESS OTHERWISE DETAILED IN THESE DRAWINGS, SPUCE TYPES AND LOCATIONS SHALL BE INDICATED ON THE SHOP DRAWINGS TO BE REVIEWED BY THE ARCHITECT/ ENGINEER. 10. STEEL BEARING ON STEEL TO BE WELDED THERETO. 11. STET SHOP DRAWINGS SHALL DETAIL ALL STEEL ELEMENTS AND CONNECTIONS AS SPECIFIED ON THE RECORD- DRAWINGS SHOULD THE STET SUPPLIER DECIDE TO ALTER ANY MEMBER SUED AND /OR CONNECTIONS. SUCH ALTERATION SHALL REQUIRE THE DESIGN AND SEAL OF THE STEEL SUPPLIER'S DELEGATED ENGINEER (WHO SHALL PROVIDE SIGNED AND SEALED SHOP DRAWINGS AND CALCULATIONS FOR THE MODIFIED MS ONLY )L 12 "SPECIAL INSPECTION SERVICES ARE REQUIRED FOR iNS TYPE OF STRUCTURE IN MIAMI -DADS AND BROWARD COUNTIES IN ADDITION TO THE INSPECTIONS PROVIDED BY THE LOCAL. BUILDING DEPARTMENT. SEE "SPECIAL INSPECTION REQUIREMENTS' SECTION IN THESE GENERAL NOTES CONTACT A/E FOR ANY REQUIRED INFORMATION AND/OR QUESTIONS STRUCTURAL DESIGN CRITERIA: 1. THE DESIGN COMPLIES WITH THE REQUIREMENTS OF THE FOLLOWING COOE(S} MIAMI -DADE AND BROWARD COUNTIES ONLY V H } 2010 FLORIDA BUILDING CODE - BUILDING FLORIDA BUILDING CODE - CURRENT SUPPLEMENTS AND AMENDMENTS ARE INCLUDED WITH ALL THE ABOVE ALL CODES SPECIFICATIONS AND OTHER APPLICABLE REF MCE% SHALL BE OF THE EDITION INDICATED IN THE ABOVE REFERENCE) CODE 2 DESIGN GRAVITY LOADS U S L. SUPERIMPOSED LOADS ZONE 2 ZONE 3 DEAD ROOF ZONE - 25 OFFICE FLOOR T30 20 ARKIN = 0- =_ STAIRS EGRESS, MECHMUCAL EQUIP. 88.8 STRUCTURAL DESIGN CRITERIA - WAND: 1. WIND DESIGN CRITERIA: WIND DESIGN CODE ASCE -700) BUILDING CATEGORY: 2 WIND VELOCITY: 175 MPH (LRFD) EN9.45@ BUILDING: EXPOSURE CATEGOR`F. 'C' KG;CPi a Q85) IMPORTANCE FACTOR: 1.00 MEAN ROOF HEIGHT: 50 FT. MAX (FLAT ROOF) CORNER DISTANCE 'a - 5.00 FT. 2 WIND FORGE SUMMARY: (A.SD - 0.50 X LRFD) 2A MAIN WIND FORCE RESISTING SYSTEM: ZONE & -56.5 PSF ZONE 4: -41.5 PSF ZONE 5: -34.0 PSF WALL (TABLE 27.6 -1): WINDWARD + LEEWARD: 401.7 PSF LEEWARD: -17.4 PSF WINDWARD: -322 PSF WIND ON PARAPET MLVA=U 78.4 PSF 28. COMPONENTS k CLADDING (CHAPTER 30 - PART 2) BUILDING ELEMENT ZONE 1 ZONE 2 ZONE 3 ZONE + ZONE - ZONE - FLAT ROOF 47.3 58.0 56.1+43.1 3 = 0- - CAI ROOFING (FLAT) 51.8 88.8 -68. O OVERHANG W 74.4 122 Cn WALL - 47.0 54.6 PARAPET WALL 1322 GLASS WINDOWS 10 EXT. METAL CLADDING PANELS 47.2 -51.2 83.0 (SEE NOTE j4) 3. THE WIND LOADS INDICATED IN THE TABLE ABOVE HAVE BEEN CALCULATED BASED ON THE 'MAIN-FRAME' DESIGN FACTORS OF THE 'ASCE -7'. STRUCTURAL ELEMENTS EXPOSED TO WIND HAVE BEEN DESIGNED BASED ON 'COMPONENTS & CLADDING' FACTORS OF THE CODE 4. WIND LOAD CALCULATIONS ON DOORS4MNDOWS 4.1 IN THE ABSENCE OF SPECIFIC INFORMATION REGARDING THE WINDOWS/DOORS (AT THE TIME OF PREPARATION OF THESE PLANS), WIND LOADS HAVE BEEN CALCULATED BASED ON THE TRIBUTARY AREA USED FOR EACH TYPE AS INDICATED, PRODUCING THE MAXIMUM POSSIBLE CALCULATED WIND PRESSUE/SUCTION (UNLESS OTHERWISE PERMITTED - SEE CONDITION '87. 4.2 THE ABOVE LISTED WIND PRESSURE/SUCTION ASSUME THAT THE SPECIFIC DOOR/ WINDOW PRODUCT APPROVAL DOCUMENTS INDICATE THAT THE TESTED WIND PRESSURE/ SUCTION CAPACITIES HAVE NOT BEEN INCREASED BY A FACTOR OF 1.33 THE CALCULATED PRESSURE/SUCTION VALUES ASSUME Kd - 0.85 CONDITION 'A': IN THE EVENT THAT THE SPECIFIC DOOR/WINDOW PRODUCT APPROVAL DOCUMENTS INDICATE THAT THE TESTED WIND PRESSURE/SUCTION CAPACITIES HAVE BEEN INCREASED. BY A FACTOR OF 1.33, THE CALCULATED PRESSURE/SUCVON VALUES SHOWN IN THE TABLE ABOVE SHALL BE MULTIPLIED BY 1.176 (TO ACCOUNT FOR Kd -1.00) CONDITION 'B': IN THE EVENT THAT THE OWNER/CONTRACTOR/MANUF. CAN SUBMIT DATA IDENTIFYING THE TRIBUTARY AREA OF THE ELEMENT THAT CONTROLLED THE TESTED CAPACITY OF THE DOOR/WINDOW. THE ENGINEER -OF- RECORD MAY ADJUST THE ABOVE LOADS DESIGNED USING SAID TRIBUTARY AREA. WIND ZONES FOR ROOF AND WALLS' 'a - 5'-0' (CORNER DISTANCE) Z 3NE (PERIMETER) TER) 3 2 ZONE 1 2 *� � (FIELD) .-I ^ -.- 3 2 3 I.Q. TYP. . GDK J0Bj:K12,059 G.D. Klieger, Inc. Consulting Structural Engineers 0 1909 Harrison St., Suite 204 EO Hollywood, Florida 33020 -5017 Phone: (954) 923 -2111 EB 0004621 EMAIL gkliegerOatt.net .. ■ .. .. I. F G S & P Design Services For The Built Environment ■ Atlanta Birmingham Cincinnati Columbus Dallas Fort Lauderdale Knoxville Jackson Jacksonville Louisville Memphis Nashville Richmond Tampa ■ G R E S H A M SMITH AND P A R T N E R S 6030 Hollywood Blvd. Suite 210 Hollywood, Florida 33024 954.981.9100 FIRM'S FLORIDA CERT. NO. AAP000034 /CA3806 1826000797/LC26000381 G.D. Klieger, Inc. Consulting Structural Engineers 1909 Harrison St., Suite 204 Hollywood, Florida 33020 -5017 Phone: (954) 923 -2111 EMAIL: gklieger ®att.net 4) aim V* 9-4 u a� 'a LLJ Q a V14 • CC o •S ;R 0 *� � O .-I ^ -.- = 0- - CAI ch Q b cc Im O W 0 Cn i KLIEGER, PE ' ' ` ' #3610 .. - . ,^' 1, ;s . (,) G Pt I r. MAR 2 9 2013 REVISION No. - Date - Revision 02 3/15/2013 BD COMMENTS RESP GENERAL NOTES S IIIIIIIII1111 I FILE: K- 12059 -S -1 1.dwg PROJECT: 29080.00 - DATE: 12/14/2012