GENERAL NOTES FOR DEMOLITION FLOOR PLANS
GENERAL NOTES FOR NEW CONSTRUCTION FLOOR PLANS
GENERAL NOTES FOR REFLECTED CEILING PLANS ----- ----- - = -; --
101. COMPLY WITH THE REQUIREMENTS OF THE FOLLOWING NOTES IN THIS SET OF DRAWINGS WHICH ALSO APPLY TO THE DEMOLITION FLOOR PLANS:
201. COMPLY WITH THE REQUIREMENTS OF THE FOLLOWING NOTES IN THIS SET OF DRAWINGS WHICH ALSO APPLY TO THE NEW CONSTRUCTION FLOOR PLANS:
501. COMPLY WITH THE FOLLOWING NOTES IN THIS SET OF DRAWINGS WHICH ALSO APPLY TO THE REFLECTED CEILING PLANS:
A. "GENERAL NOTES FOR NEW CONSTRUCTION FLOOR PLANS" ON THIS SHEET
A. "GENERAL NOTES FOR DEMOLITION FLOOR PLANS" ON THIS SHEET
A. "GENERAL NOTES FOR DEMOLITION FLOOR PLANS" ON THIS SHEET
B. "GENERAL NOTES FOR DIMENSION FLOOR PLANS" ON THIS SHEET
D. "GENERAL NOTES FOR DIMENSION FLOOR PLANS" ON THIS SHEET
B. "GENERAL NOTES FOR NEW CONSTRUCTION FLOOR PLANS" ON THIS SHEET _
C. "GENERAL NOTES FOR REFLECTED CEILING PLANS" ON THIS SHEET
C. "GENERAL NOTES FOR REFLECTED CEILING PLANS" ON THIS SHEET
C. "GENERAL NOTES FOR DIMENSION FLOOR PLANS" ON THIS SHEET
D. "GENERAL NOTES FOR EXTERIOR ELEVATIONS" ON THIS SHEET
D. "GENERAL NOTES FOR CABINETWORKICASEWORK" ON SHEET A5.1
D. "GENERAL NOTES FOR EXTERIOR ELEVATIONS" ON THIS SHEET
E. "GENERAL NOTES FOR ROOF PLAN" ON THIS SHEET
E. "GENERAL NOTES FOR EXTERIOR ELEVATIONS" ON THIS SHEET
E. "GENERAL NOTES FOR ROOF PLAN" ON THIS SHEET -
F. "GENERAL NOTES FOR ROOF PLAN" ON THIS SHEET
102. THE DEMOLITION DRAWINGS HAVE BEEN DEVELOPED FROM EXISTING DRAWINGS, WHICH WERE PROVIDED TO THE ARCHITECT /ENGINEER BY THE OWNER,
502. THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE REFLECTED CEILING PLANS WITH: ELECTRICAUS LIGHTING, iYSTEMS AND COMMUNICATIONS_
AND THEY MAY NOT REFLECT ACTUAL FIELD CONDITIONS. PRIOR TO PROCEEDING WITH ANY WORK, THE CONTRACTOR SHALL VERIFY THE ACCURACY OF THESE
202. SEE DIMENSION FLOOR PLANS, ENLARGED PLANS, INTERIOR ELEVATIONS, DETAILS, ETC., FOR DIMENSIONS AND KEYNOTES WHICH APPLY TO THE NEW
DRAWINGS; MECHANICAUS SUPPLY, RETURN AND EXHAUST DRAWINGS; AND FIRE PROTECTION'S DRAWINGS. THE CONTRACTOR SRALL T-HE Ii MME TELY
DRAWINGS IN COMPARISON TO EXISTING FIELD CONDITIONS AND THEN IMMEDIATELY NOTIFY THE ARCHITECT OF ANY INCONSISTENCIES BETWEEN THESE
CONSTRUCTION FLOOR PLANS.
NOTIFY THE ARCHITECT OF ANY ERROR, INCONSISTENCY OR OMISSION THAT IS DISCOVERED.
DRAWINGS AND ACTUAL CONDITIONS.
203. REFER TO ARCHITECTURAL SCHEDULES AND LEGENDS LOCATED AS FOLLOWS:
503. SEE ELECTRICAL, COMMUNICATION, SECURITY AND FIRE PROTECTION DRAWINGS FOR LOCATIONS OF CEILING MOUNTED SMOKE DETECTORS, COMMUNICATION
103. THE CONTRACTOR SHALL ALSO IMMEDIATELY NOTIFY THE ARCHITECT IF ANY DEMOLITION OR NEW CONSTRUCTION WORK (AS INDICATED IN THE
A. TOILET ACCESSORY SET SCHEDULE: SEE SPECIFICATION SECTION 10 2800 IN THE PROJECT MANUAL
DEVICES, FIRE ALARM DEVICES, SECURITY DEVICES, ETC.
CONSTRUCTION DOCUMENTS) CANNOT BE PERFORMED DUE TO EXISTING FIELD CONDITIONS.
B. DOOR, FRAME AND HARDWARE SCHEDULE, NOTES AND ABBREVIATIONS: SEE SHEET A9.1
C. DOOR, FRAME AND HARDWARE LEGENDS AND DETAILS: SEE SHEET A9.1
504. ONLY CEILING MOUNTED EXIT LIGHTS ARE SHOWN ON THE REFLECTED CEILING PLANS. SEE THE ELECTRICAL DRAWINGS FOR LOCATIONS OF WALL MOUNTED
104. SEE CIVIL, MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL, COMMUNICATIONS AND SECURITY SYSTEMS DRAWINGS FOR DEMOLITION OF UTILITIES.
D. INTERIOR WINDOW SCHEDULE, NOTES AND ABBREVIATIONS: SEE SHEET A9.1
EXIT LIGHTS. (NOTE: THE BOTTOM OF EXIT LIGHTS SHALL BE A MINIMUM OF T-O" CLEAR AFF.)
E. INTERIOR WINDOW LEGENDS AND DETAILS: SEE SHEET A9.1
105. DEMOLITION WORK SHALL BE EXECUTED IN CONFORMANCE WITH ALL CODES AND ORDINANCES AS SET FORTH BY ALL AUTHORITIES HAVING JURISDICTION
F. EXTERIOR WINDOW DESIGNATIONS AND LEGEND: SEE EXTERIOR ELEVATIONS FOR DESIGNATIONS AND SEE SHEETS A3.3 -A3.4 FOR EXTERIOR WINDOW
505. SPRINKLER HEADS:
[AHJ].
LEGEND
A. THE ONLY SPRINKLER HEADS SHOWN ON THE REFLECTED CEILING PLANS HAVE BEEN SHOWN FOR AESTHETIC PURPOSES.
G. CABINETWORK AND CASEWORK LEGEND: SEE SHEET A5.1
B. THE CONTRACTOR SHALL INSTALL SUFFICIENT HEADS IN ALL SPACES TO PROVIDE COMPLETE (100 %) AUTOMATIC SPRINKLER COVERAGE AS DEFINED IN
106. WHERE EXISTING CONSTRUCTION IS FOUND TO CONTAIN ANY HAZARDOUS MATERIAL, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER AND THE
NFPA STANDARD 13, SPECIFICATION DMSION 21 - FIRE SUPPRESSION AND AS SHOWN ON THE FIRE PROTECTION DRAWINGS.
ARCHITECT IN WRITING. NOTE: REMOVAL, DISPOSAL AND REPLACEMENT OF THE HAZARDOUS MATERIAL IS THE SOLE RESPONSIBILITY OF THE OWNER, AND
204. SEE REFLECTED CEILING PLANS ON SHEETS A6.1 -A6.4 FOR LOCATIONS OF GYPSUM BOARD OR CEMENT PLASTER FURR DOWNS AND SOFFITS (AS SHOWN IN
C. NEITHER SPRINKLER HEADS OR CONCEALED SPRINKLER HEAD COVERS ARE ALLOWED TO BE PAINTED. THE CONTRACTOR SHALL VERIFY THAT ANY
SHALL BE IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS.
DETAILS 12A & 12B/A8.1, 14A & 14B/A8.1, 16A & 16B/A8.1, 1/A8.2, 6A & 6B/A8.2, 7/A8.2 AND 8/A8.2).
SPRINKLER HEADS THAT ARE ACCIDENTALLY PAINTED ARE REMOVED FROM THE SITE AND REPLACED WITH NEW SPRINKLER HEADS.
205. REFER TO SHEETS A8.1 -A8.4, A8.15 -A8.16 AND A8.22 -A8.23 FOR TYPICAL DETAILS WHICH APPLY TO THE NEW CONSTRUCTION FLOOR PLANS, BUT WHICH MAY
506. ACCESS PANELS IN NON- ACCESSIBLE FINISH CEILINGS:
NOT BE SPECIFICALLY "KEYED -IN" ON THE FLOOR PLANS.
A. THE CONTRACTOR SHALL VERIFY THAT ACCESS PANELS (OF APPROPRIATE SIZE AND TYPE) ARE INSTALLED IN GYPSUM BOARD, CEMENT PLASTER, METAL
AND OTHER NON - ACCESSIBLE TYPE CEILINGS AND SOFFITS WHERE ACCESS, SERVICE OR ADJUSTMENT TO ITEMS (INCLUDING MECHANICAL, PLUMBING,
206. SEE INTERIOR DESIGN DRAWINGS FOR INTERIOR FINISHES AND FOR LOCATIONS OF ACCENT WALLS AND WALL PROTECTION.
ELECTRICAL, COMMUNICATIONS, SECURITY, ETC.) ABOVE THE CEILINGS MAY BE REQUIRED. COMPLY WITH THE SPECIFICATIONS AND WITH NEC RULE 314.29.
B. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WITH ALL SUB - CONTRACTORS AND WITH THE OWNER'S VENDORS TO VERIFY
207. SEE SHEETS A8.22 -A8.23 AND "GENERAL NOTES FOR DIMENSION FLOOR PLANS" ON THIS SHEET FOR CRITICAL ACCESSIBILITY CODE REQUIREMENTS REGARDING:
THAT THE MINIMUM NUMBER OF ACCESS PANELS ARE PROVIDED (BY THE SHARING OF ACCESS PANELS WHEREVER POSSIBLE).
ELEVATORS; MANEUVERING CLEARANCES AT DOORS; TOILET ROOMS; PLUMBING FIXTURES (WATER CLOSETS, SINKS, LAVATORIES, ELECTRIC WATER COOLERS,
C. LOCATIONS OF ALL ACCESS PANELS MUST BE APPROVED IN ADVANCE BY THE ARCHITECT IN ORDER TO ENSURE THAT THE "AESTHETIC DESIGN INTEGRITY"
ETC.); DRESSING ROOMS; MOUNTING OF TOILET ACCESSORIES; ETC.
OF CEILINGS AND SOFFITS IS MAINTAINED.
D. PRIOR TO THE INSTALLATION OF ANY ACCESS PANELS, THE CONTRACTOR SHALL SUBMIT COORDINATION DRAWINGS (SHOWING THE PROPOSED LAYOUT
208. AT ALL EXTERIOR WALLS CONSTRUCTED OF CONCRETE MASONRY UNITS [CMU], THE CMU SHALL BE EXTENDED UP TO THE STRUCTURE ABOVE AND BE SEALED
AND SIZE OF EACH ACCESS PANEL) TO THE ARCHITECT FOR APPROVAL.
"AIR - TIGHT" AND "SOUND- TIGHT'.
E. ACCESS PANELS SHALL BE THE FIRE RATED TYPE EQUAL TO THE RATING OF THE CEILING OR SOFFIT IN WHICH THEY OCCUR.
F. SEE "GENERAL NOTES FOR PROJECT" ON SHEET X1.1 REGARDING THE REQUIREMENTS FOR THE LOCKING OF ACCESS PANELS.
209. NOTE: ONLY SOME OF THE REQUIRED GRAB BARS ARE SHOWN ON THE FLOOR PLANS. SEE ENLARGED PLANS, INTERIOR ELEVATIONS, SPECIFICATION SECTION 10
2800; TOILET ACCESSORY SCHEDULE, ETC., FOR ADDITIONAL LOCATIONS WHERE GRAB BARS ARE ALSO REQUIRED.
507. THE CONTRACTOR SHALL ALSO PROVIDE ACCESS PANELS IN GYPSUM BOARD AND /OR OTHER HARD SURFACE CEILINGS AND SOFFITS SO THAT THE ARCHITECT
AND THE AUTHORITIES HAVING JURISDICTION CAN INSPECT RATED FIRE BARRIERS. THESE ACCESS PANELS SHALL BE LOCATED AT INTERVALS NOT TO EXCEED
210. REGARDING ACCESS PANELS:
30' -0" ON CENTER, WITH A MINIMUM OF ONE ACCESS PANEL PER SPACE, AND IN SUCH MULTIPLE LOCATIONS AS NECESSARY TO VIEW ALL PLANES AND SURFACES
A. THE CONTRACTOR SHALL VERIFY THAT ACCESS PANELS OF TYPE SPECIFIED ARE INSTALLED IN WALLS AND IN "NON - ACCESSIBLE TYPE" CEILINGS AND
OF THE RATED FIRE BARRIERS. (ALSO, COMPLY WITH NOTE 506.)
SOFFITS WHERE ACCESS, SERVICE OR ADJUSTMENT TO MECHANICAL, PLUMBING, FIRE PROTECTION, SECURITY, ELECTRICAL AND COMMUNICATION ITEMS
MAY BE REQUIRED.
508. THE CONTRACTOR SHALL ADVISE THE OWNER AND TENANTS THAT AN 18 INCH MINIMUM VERTICAL CLEARANCE SHALL BE MAINTAINED BETWEEN THE BOTTOM
B. ACCESS PANELS SHALL BE THE "FIRE RATED TYPE" EQUAL TO THE RATING OF THE WALL, BARRIER, PARTITION, SOFFIT OR CEILING IN WHICH THEY OCCUR.
OF THE EXTENDED (DROP DOWN) SPRINKLER HEADS AND THE TOP OF ANY FILES, SHELVING, EQUIPMENT, LOCKERS, ETC., (WHETHER CONTRACTOR OR OWNER
C. WALL MOUNTED ACCESS PANELS LOCATED IN RATED FIRE WALLS, RATED FIRE BARRIERS, RATED SMOKE BARRIERS AND /OR NON -RATED SMOKE
FURNISHED). THE CONTRACTOR SHALL ALSO ADVISE THE OWNER AND TENANTS THAT ITEMS SHALL NOT BE PLACED OR STORED ON TOP OF SHELVING SO THAT
PARTITIONS SHALL BE SELF - CLOSING AND "KEY LOCKED ".
THIS CODE REQUIRED 18 INCH MINIMUM VERTICAL CLEARANCE WILL BE MAINTAINED.
D. WALL MOUNTED ACCESS PANELS SHALL BE "KEY LOCKED" IN SPACES THAT ARE ACCESSIBLE TO THE PUBLIC, PATIENTS AND GENERAL STAFF.
509. IN A MEANS OF EGRESS (OTHER THAN AS INDICATED IN NOTE 512 BELOW), THE CEILING SHALL BE INSTALLED SO THAT THE MINIMUM CLEAR VERTICAL
211. SEE SPECIFICATION SECTION 09 2900 AND THESE DRAWINGS FOR REQUIRED LOCATIONS OF 5/8 INCH TYPE "X" GLASS MAT PAPERLESS INTERIOR GYPSUM
HEADROOM IS 7-10" CLEAR AFF, AND SO THAT PROJECTIONS FROM AND BELOW THE CEILING ARE A MINIMUM OF 6-8" CLEAR AFF. (COMPLY WITH NOTE 510.)
BOARD. (NOTE: THE USE OF WATER - RESISTANT GYPSUM BOARD [GREEN BOARD] IS NOT ACCEPTABLE IN WET LOCATIONS. INSTEAD, USE 5/8 INCH TYPE "X" GLASS
MAT PAPERLESS INTERIOR GYPSUM BOARD.)
510. REGARDING MINIMUM REQUIRED CEILING HEIGHTS, COMPLY WITH THE MOST STRINGENT OF THE FOLLOWING CODES: SECTION 1208 OF THE FBC.
212. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WITH THE OWNER'S EQUIPMENT VENDORS TO INSURE THAT THERE WILL BE NO OWNER
511. SEE THE INTERIOR DESIGN DRAWINGS FOR THE PAINT SPECIFICATIONS AND COLORS OF PAINTED CEILINGS AND INTERIOR SOFFITS.
FURNISHED ITEMS (WITH A SURFACE AREA GREATER THAN 16 SQUARE INCHES) RECESSED INTO A RATED FIRE BARRIER OR RATED SMOKE BARRIER. SEE DETAIL
5/A8.2 "RECESSED METAL WALL CABINETS" FOR DETAILS ON HOW TO PROVIDE FOR RECESSED ITEMS IN A RATED FIRE AND /OR SMOKE BARRIER. ITEMS RECESSED
512. SEE SPECIFICATION SECTION 09 9113 AND THE EXTERIOR ELEVATIONS FOR THE PAINT SPECIFICATIONS AND COLORS OF PAINTED EXTERIOR SOFFITS.
IN NON -RATED SMOKE PARTITIONS OR ALL OTHER FULL HEIGHT PARTITIONS SHALL BE SEALED "AIR- TIGHT' AT ALL PENETRATIONS.
513. SEE THE SECTIONS AND DETAILS THROUGH THE STAIRWAYS FOR THE FINISH MATERIALS ON THE EXPOSED UNDERSIDES OF THE STAIR LANDINGS AND STAIR
213. SEE 8/A8.22 FOR DETAIL OF A RECESSED ELECTRIC WATER COOLER [EWC] ALCOVE.
RUNS. SEE THE INTERIOR DESIGN DRAWINGS FOR THE PAINT SPECIFICATIONS AND COLORS OF PAINTED SURFACES.
214. THE ENCLOSURE WALLS /PARTITIONS /BARRIERS SHALL BE EXTENDED UP TO THE DECK ABOVE AND BE SEALED "AIR - TIGHT' IN SPACES WHERE SOUND
TRANSMISSION LIMITATIONS ARE EITHER REQUIRED BY THE CODE OR NECESSARY TO COMPLY WITH GOOD DESIGN PRACTICE. THESE SPACES INCLUDE, BUT ARE
NOT LIMITED TO, THE FOLLOWING: TOILET ROOMS; CONFERENCE ROOMS; STAFF LOUNGES; CONSULTATION ROOMS; EXAM ROOMS; TREATMENT ROOMS; AND
GENERAL NOTES FOR EXTERIOR ELEVATIONS
ROOMS WITHOUT FINISH CEILINGS.
601. PAINT EXPOSED ROOF MOUNTED EQUIPMENT, PIPING, SCREENS, ETC. IN A COLOR AS SELECTED BY THE ARCHITECT; EXCEPT THAT, ITEMS WHICH ARE
ALUMINUM OR STAINLESS STEEL SHALL NOT BE PAINTED.
GENERAL NOTES FOR DIMENSION FLOOR PLANS
602. THE EXTERIOR WALL FINISH MATERIAL SHALL BE PAINTED STUCCO. SEE FINISH LISTING ON SHEET DO.1 FOR PAINT COLOR.
301. COMPLY WITH THE REQUIREMENTS OF THE FOLLOWING NOTES IN THIS SET OF DRAWINGS AS THEY ALSO APPLY TO THE DIMENSION FLOOR PLANS:
603. THE COLOR OF THE FASCIA AT THE GRAVEL GUARD SHALL MATCH EXTERIOR PAINT COLOR.
A. "GENERAL NOTES FOR DEMOLITION FLOOR PLANS" ON THIS SHEET
B. "GENERAL NOTES FOR NEW CONSTRUCTION FLOOR PLANS" ON THIS SHEET
604. PAINT EXTERIOR METAL STAIRS, PIPE RAILS, HANDRAILS AND GUARDRAILS IN A COLOR AS SELECTED BY THE ARCHITECT (IF NOT OTHERWISE INDICATED).
C. "GENERAL NOTES FOR REFLECTED CEILING PLANS" ON THIS SHEET
D. "GENERAL NOTES FOR EXTERIOR ELEVATIONS" ON THIS SHEET
605. PROVIDE WALL MOUNTED BACK-LIT SIGNAGE ON THE EXTERIOR OF THE BUILDING. SEE GRAPHICS DRAWINGS FOR DETAILS.
E. "GENERAL NOTES FOR ROOF PLAN" ON THIS SHEET
A. AT GARAGE /RAMP ENTRANCES: PROVIDE ELECTRICAL CONNECTION.
B. AT MAIN ENTRANCE: PROVIDE ELECTRICAL CONNECTION.
302. SEE NEW CONSTRUCTION FLOOR PLANS FOR: WALLS /PARTITIONS /BARRIERS DESIGNATIONS; DOOR DESIGNATIONS; INTERIOR WINDOW DESIGNATIONS;
C. AT WEST WALL OF ELEVATOR SHAFT: PROVIDE ELECTRICAL CONNECTION.
ADDITIONAL DETAIL, SECTION AND ELEVATION MARKERS; AND ADDITIONAL NOTES WHICH ALSO APPLY TO THE DIMENSION FLOOR PLANS.
303. FOR ADDITIONAL DIMENSIONING, COMPLY WITH REQUIREMENTS ON ENLARGED PLANS, WALL SECTIONS, EXTERIOR ELEVATIONS, INTERIOR ELEVATIONS, PLAN
DETAILS AND SECTION DETAILS.
GENERAL NOTES FOR ROOF PLAN
304. THE CONTRACTOR SHALL NOT SCALE THE DRAWINGS. IF DIMENSIONS ARE IN QUESTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING
701. COMPLY WITH THE REQUIREMENTS OF THE FOLLOWING NOTES IN THIS SET OF DRAWINGS AS THEY ALSO APPLY TO THE ROOF PLAN:
CLARIFICATION FROM THE ARCHITECT PRIOR TO CONTINUING WITH CONSTRUCTION.
A. "GENERAL NOTES FOR DEMOLITION FLOOR PLANS" ON THIS SHEET
B. "GENERAL NOTES FOR NEW CONSTRUCTION FLOOR PLANS" ON THIS SHEET
305. DIMENSIONS SHOWN ON THE FLOOR PLANS ARE: TO CENTERLINE OF COLUMNS; TO OUTSIDE FACE OF GYPSUM BOARD AT METAL STUD
C. "GENERAL NOTES FOR DIMENSION FLOOR PLANS" ON THIS SHEET
WALLS /PARTITIONS /BARRIERS; TO OUTSIDE FACE OF CONCRETE /CMU /MASONRY WALLS/ PARTITIONS /BARRIERS; ETC. EXTREMELY CRITICAL MINIMUM DIMENSIONS
D. "GENERAL NOTES FOR EXTERIOR ELEVATIONS" ON THIS SHEET
MAY BE INDICATED AS "MINIMUM" OR "MINIMUM CLEAR ". COMPLY WITH NOTE 306 BELOW.
E. "GENERAL NOTES FOR REFLECTED CEILING PLANS" ON THIS SHEET
306. CRITICAL NOTE: THE CONTRACTOR SHALL TAKE INTO ACCOUNT THE THICKNESSES OF THE SCHEDULED FINISH MATERIALS SUCH AS CERAMIC TILE, SOLID
F. "GENERAL NOTES FOR ROOF PLAN" ON THIS SHEET
SURFACE MATERIAL, ETC., PRIOR TO "LAYING OUT' METAL STUD OR CMU WALLS /PARTITIONS /BARRIERS, SINCE THE TOTAL "OUT -TO -OUT' WALL THICKNESS MUST
702. REFER TO MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL AND LIGHTNING PROTECTION DRAWINGS FOR LOCATIONS OF ADDITIONAL ITEMS
BE CONSIDERED SO THAT THE REQUIRED "MINIMUM FACE -OF- FINISH" AND "MINIMUM CLEAR FACE -OF- FINISH" DIMENSIONS CAN BE MAINTAINED AFTER THE
WHICH HAVE NOT BEEN SHOWN ON THIS ROOF PLAN (INCLUDING PIPING, CURBS, VENTS, DUCTS, FANS, LIGHTNING PROTECTION, ETC.).
INSTALLATION OF THE FINISH MATERIALS.
703. PAINT EXPOSED ROOF MOUNTED EQUIPMENT, PIPING, ETC. IN A COLOR AS SELECTED BY ARCHITECT, EXCEPT THAT ITEMS WHICH ARE ALUMINUM OR
307. INTERIOR METAL STUD WALLS /PARTITIONS /BARRIERS SHALL BE CONSTRUCTED OF 3 5/8" (MINIMUM) METAL STUDS (OR AS SHOWN BELOW) UNLESS
STAINLESS STEEL SHALL NOT BE PAINTED.
DIMENSIONED, DETAILED OR NOTED OTHERWISE. THE CONTRACTOR SHALL ALSO COMPLY WITH U.L. DESIGN NO. U444 OR U458 AT RATED PLUMBING
WALLS /BARRIERS.
704. THE GENERAL CONTRACTOR SHALL VERIFY THAT THERE IS PROPER COORDINATION BETWEEN THE ROOFING CONTRACTOR AND THE PLUMBING
CONTRACTOR SO THAT ALL ROOF DRAINS ARE SET AT A "LOW POINT', AND SO THAT ALL AREAS OF ALL ROOFS SLOPE TO A ROOF DRAIN AT A MINIMUM
FLOOR - MOUNTED SINGLE WATER CLOSET: 8" OUTSIDE FACE OF 3 -5/8" (MINIMUM) STUD TO OUTSIDE FACE OF 3 -5/8" (MINIMUM) STUDS
SLOPE OF 1/4 INCH (VERTICAL) IN 1'-0" (HORIZONTAL). THE ROOF SLOPE MUST BE CONTINUOUS WITH A CONSTANT GRADIENT /DEGREE OF SLOPE FROM
FLOOR- MOUNTED BACK -TO -BACK WATER CLOSETS: 1' -0" OUTSIDE FACE OF 3 -5/8" (MINIMUM) STUD TO OUTSIDE FACE OF 3 -5/8" (MINIMUM) STUDS
"HIGH POINT' TO "LOW POINT'. CHANGE IN GRADIENT /DEGREE OF ROOF SLOPE IS NOT ALLOWED IN ANY SINGLE "RUN" OF THE ROOF. THE ABSOLUTE
FIRE EXTINGUISHER CABINET: 6" (MINIMUM) STUDS
MINIMUM ROOF SLOPE SHALL BE 1/4 INCH (VERTICAL) IN 1' -0" (HORIZONTAL); HOWEVER, THE ROOF SLOPE IN MANY AREAS MAY BE MUCH STEEPER THAN 1/4
WALL- MOUNTED JANITOR SINK: 6" STUDS
INCH (VERTICAL) IN 1' -0" (HORIZONTAL) IN ORDER TO PROVIDE THE REQUIRED CONSTANT GRADIENT /DEGREE OF SLOPE.
A. IN REGARDS TO ROOF DRAINAGE COMPLY WITH OF THE FLORIDA BUILDING CODE [FBC] SECTION 1503.4.
308. CABINETWORKICASEWORK DIMENSIONS SHALL BE FIELD VERIFIED PRIOR TO FABRICATION AND INSTALLATION. SEE THE "GENERAL NOTES FOR
CABINETWORK/CASEWORK" ON SHEET A5.1 FOR FURTHER REQUIREMENTS REGARDING CABINETWORK/CASEWORK DIMENSIONING.
705. ALL PENETRATIONS THROUGH RATED ROOF AND RATED ROOF /CEILING ASSEMBLIES SHALL BE PROTECTED WITH AN APPROVED TESTED
'THROUGH - PENETRATION FIRESTOP SYSTEM" AND /OR "FIRE- RESISTANT JOINT SYSTEM, IN ACCORDANCE WITH THE REQUIREMENTS OF FBC SECTIONS 712.4
309. SEE DETAILS 5, 6, 7, 8 & 9 ON SHEET A8.22 FOR DIMENSIONED ELEVATIONS OF TYPICAL ACCESSIBLE TOILET ROOMS, LAVATORIES, SINKS AND WATER CLOSETS.
& 713.
ALSO, COMPLY WITH NOTE 306 ABOVE.
310. ACCESSIBLE WATER CLOSETS SHALL BE MOUNTED SO THAT THERE IS EXACTLY V -6" BETWEEN THE "FINISH FACE" OF THE NEAREST ADJACENT SIDE WALL AND
THE CENTERLINE OF THE WATER CLOSET. SEE DETAILS 5, 6 & 9 ON SHEET A8.22. THE FLUSH VALVE HANDLE FOR EACH ACCESSIBLE WATER CLOSET SHALL BE
MOUNTED ON THE "OPEN- MOST" SIDE OF THE WATER CLOSET AT T -8" MAXIMUM AFF TO THE TOP OF THE HANDLE-. ALSO, COMPLY WITH NOTE 306 ABOVE.
311. SEE OWNER FURNISHED VENDOR DRAWINGS (INCLUDING LINEAR ACCELERATOR AND VAULT) FOR CRITICAL DIMENSIONS IN SPACES 114 AND 118.
312. SEE PLANS AND THE EXTERIOR ELEVATION SHEETS FOR EXTERIOR WINDOW DESIGNATIONS AND THE EXTERIOR WINDOW LEGEND.
313. THE CONTRACTOR SHALL VERIFY ALL "EDGE OF SLAB" DIMENSIONS BY REFERENCING THE ARCHITECTS SECTIONS AND DETAILS.
314. SEE PROJECT INFORMATION SHEET X1.1 AND THE SHEET SPECIFIC KEYNOTES ON EACH NEW CONSTRUCTION FLOOR PLAN FOR LOCATIONS OF REQUIRED SOUND
TRANSMISSION CLASS [STC] RATINGS, SOUND ATTENUATION BLANKETS, ETC.
Design Services
For The Built
Environment
E
Atlanta Birmingham
Cincinnati
Columbus Dallas
Fort Lauderdale
Knoxville Jackson
Jacksonville Louisville
Memphis Nashville
Richmond Tampa
N
G R E S H A M
S M I T A N D
P A R T N E R S
6030 Hollywood Blvd.
Suite 210
Hollywood, Florida 33024
954.981.9100
FIRM'S FLORIDA
CERT. NO.
AAP000034 /CA3806
1B26000797/LC26000381
f
.� Rt
.v M
Q
y�� 0 •� N W
�' i 0 O
moms � 0 ^ �
cn
O � Lo
V ,
O X LO
W O
SEAL: Kristin S. Herman -Druck
AR9517Z
REVISION
No. - Date - Revision
GEM ZAL NOTES FOR
PRO: 'CT
X1.3
FILE: 9080X103.dgn
PROJECT: 29080.00
DATE: 12/14/2012
Copyright 2012 Gresham, Smith ana Fartners. An Kignts Keservea. -