13-96-009N M Q Ln
M M M
zzzzz
_3 _J J -I -__I
n
a) a)
L L
p 7 7
Uj N N
)M JW rn'TU -i
n CL U. W.- NMQL17
V -Nz tL t'I..L_I..L_LL LL_L.�
>-- W U U Q W W W W W
Inmu_ L Ldp =1===
L fA 4% 1% Q Q H! EA iA f% fH fA
a�
a
v
CL
a
Ln
(D
c
a�
a
i
U)
V �
L
o
o cn
J"M c v
10 a- --
�Nrn C
1.'- o *,% _ • -
n \ N
°
m �
WALLS /PARTITIONS /BARRIERS LEGEND
NON -RATED GWB PARTITION
FASTENERS MAXIMUM 24" O.C.
UNDERSIDE OF STRUCTURAL FLOOR/ROOF
1/2" STRUCTURAL DEFLECTION
ALLOWANCE
CONT. ACOUSTICAL SEALANT BOTH SIDES
DEFLECTION TRACK FOR
1/2" OR LESS MOVEMENT.
ACOUSTICAL INSULATION (WHERE AN
STC IS REQUIRED)
CEILING AS SCHEDULED
GYP. BD.
NON- STRUCTURAL STEEL STUDS
RUNNER TRACK (SECURED TO FLOOR)
BASE AS SCHEDULED
CONT. ACOUSTICAL SEALANT
BOTH SIDES
TOP OF STRUC. SLAB
FASTENERS MAXIMUM 24" O.C.
ONE LAYER GYP BD EACH SIDE APPLIED VERTICALLY. STAGGER
° ABUTTING END JOINTS NOT LESS THAN ONE FRAMING MEMBER IN
ALTERNATE COURSES OF PANELS. REFER TO SECTION 09 2900
OF PROJECT MANUAL FOR MORE INFORMATION.
SEE GENERAL NOTES FOR WALLS /PARTITIONS ON SHEET X1.2
° FOR ADDITIONAL INFORMATION AND REQUIREMENTS.
-RATED PTN. I oo I NO ABOVE FILING RA
PARTITION
• 3 5/8 ", 25 GA, 16" O.C. STEEL STUDS
• ONE LAYER 5/8" GYP. BD. EACH SIDE TO 4" ABOVE CEILING
- ACOUSTICAL INSULATION (WHERE INDICATED)
- TERMINATE PARTITION AT UNDERSIDE STRUCT. FLOOR/ROOF
• OVERALL DIM: 4-7/8"
0 0 0 ovL1-) 0 0 0 ov1 1) 0 0 0 orI1-) 0
NON -RATED PTN. FRAMED PARTITION TO DECK
01 -3 5/8 ", 25 GA, 16" O.C. STEEL STUDS
• ONE LAYER 5/8" GYP. BD. EACH SIDE
• ACOUSTICAL INSULATION (WHERE AN STC IS REQUIRED)
• TERMINATE PARTITION AT UNDERSIDE STRUCT. FLOOR/ROOF
• OVERALL DIM: 4-7/8"
NON -RATED PTN. FRAMED PARTITION TO DECK
02 -3 5/8 ", 25 GA, 16" O.C. STEEL STUDS
- ONE LAYER 5/8" GYP. BD. OFFICE SIDE
• TWO LAYERS 5/8" GYP. BD. LOBBY/ CORRIDOR SIDE
-ACOUSTICAL INSULATION (WHERE AN STC IS REQUIRED)
- TERMINATE PARTITION AT UNDERSIDE STRUCT. FLOOR/ROOF
• OVERALL DIM: 4-7/8"
*WHEN SOUND ATTENUATION BLANKETS ARE INDICATED TO BE
USED BUT AN STC RATING IS NOT REQUIRED PROVIDE A MINIMUM
OF OhE LAYER OF GYPSUM BOARD ON AT LEAN ONE SIDE OF THE
PARTITION (UP TO DECK ABOVE).*
*PROVIDE SLOTTED SLIP TRACK TO ALLOW 1" VERTICAL
DEFLECTION AT TOP OF ALL 1ST FLOOR PARTITIONS TO DECK.
PARTITION SEALED TO RESIST
PASSAGE OF SMOKE ONE SIDE
■ ■ ■ ■ 11�TP ■ ■ ■ ■ ■ ■ ■ ■
5/8" TYPE "X" GYPSUM BOARD
SHALL BE CUT TO FIT WITHIN 1/2"
OF DECK FLUTES.
FILL FLUTES WITH MINERAL WOOL
UNDERSIDE OF STRUCTURAL FLOOR/ROOF
1/2" STRUCTURAL DEFLECTION
ALLOWANCE
CONT. ACOUSTICAL SEALANT BOTH SIDES
SEAL ALL "HEAD -OF- WALLS" BOTH
AIR -TIGHT AND SOUND- TIGHT.
DEFLECTION TRACK FOR
1/2" OR LESS MOVEMENT.
WHERE STC RATING IS NOT REQUIRED GYP.
BD. MAY TERMINATE 6" ABOVE CEILINd
CEILING AS SCHEDULED
ACOUSTICAL INSULATION (WHERE AN
STC IS REQUIRED)
GYP. BD.
NON - STRUCTURAL STEEL STUDS
RUNNER TRACK (SECURED TO FLOOR)
BASE AS SCHEDULED
CONT. ACOUSTICAL SEALANT (BOTH SIDES)
TOP OF STRUC. SLAB
FASTENERS MAXIMUM 24" O.C.
5l8" TYPE "X" GYPSUM BOARD
SHHALL BE CUT TO FIT WITHIN
DECK FLUTES PER MAXIMUM
GAP ALLOWED BY APPROVED
"FIRE RSISTANT JOINT SYSTEM ".
UNDERSIDE OF STRUCTURAL FLOOR/ROOF
1/2" STRUCTURAL DEFLECTION
ALLOWANCE
CONT. FIRE STOP SEALANT BOTH SIDES
PROVIDE APPROVED "FIRE -
RSISTANT JOINT SYSTEM ". SEAL ALL
"HEAD -0F - WALLS" BOTH
AIR -TIGHT AND SOUND- TIGHT.
DEFLECTION TRACK FOR
1/2" OR LESS MOVEMENT.
CEILING AS SCHEDULED
ACOUSTICAL INSULATION (WHERE AN
STC IS REQUIRED)
GYP. BD.
NON- STRUCTURAL STEEL STUDS
RUNNER TRACK (SECURED TO FLOOR)
BASE AS SCHEDULED
CONT. FIRE STOP SEALANT (BOTH SIDES)
TOP OF STRUC. SLAB
FASTENERS MAXIMUM 24" O.C.
A 1 HOUR PTN FRAMED FIRE BARRIER
- 3 5/8 ", 25 GA, 16" O.C. STEEL STUDS
- ONE LAYER 5/8" FIRE RATED TYPE X GYP. BD. EACH SIDE
- ACOUSTICAL INSULATION (WHERE AN STC IS REQUIRED)
■ UL DESIGN NO. U465
-OVERALL DIM: 4-7/8"
° (3 5/8' MINIMUM) METAL STUDS AT 1'-4 ")MAXIMUM O.C.
ItENQUIREM CLOSER
TS OF "GENERAL NOTES FOR WALLS /P RTITIONS /BARRIERS"
ON THIS SHEET.
° THIS PARTITION TO RESIST PASSAGE OF SMOKE ON ONE SIDE SHALL ALSO
COMPLY WITH ALL REQUIREMENTS OF 2009 NFPA 101 LIFE SAFETY CODE
SECTION 8.5 AND *REFERENCE APPROPRIATE FBC SECTIONS FOR
FLORIDA PROJECTS*
° MINIMUM OF ONE LAYER 5/8" TYPE "X" GYPSUM BOARD
EACH SIDE APPLIED VERTICALLY. PROVIDE ADDITIONAL
LAYERS OF GYPSUM BOARD WHEN REQUIRED TO OBTAIN THE INDICATED
STC RATING. STAGGER ALL VERTICAL JOINTS 1'-4" MINIMUM O.C. AND
STAGGER ALL HORIZONTAL JOINTS 2' -0" MINIMUM O.C. ALL HORIZONTAL
JOINTS SHALL OCCUR ABOVE THE CEILING. APPLY 1" TYPE "S" STEEL
SCREWS AT 8" O.C. ALONG EDGES OF BOARD AND AT V -0" O.C. IN THE
FIELD OF THE BOARD.
° SEAL GYPSUM BOARD TO FLOOR SLAB BELOW PER GENERAL
NOTES 5 AND 6. EXTEND GYPSUM BOARD TO DECK ABOVE
AND SEAL PER GENERAL NOTES 3 AND 5. SEAL ALL PENETRATIONS PER
GENERAL NOTES 4 AND 7.
*PROVIDE SLOTTED SLIP TRACK TO ALLOW 1" VERTICAL
DEFLECTION AT TOP OF ALL 1ST FLOOR PARTITIONS TO DECK.
PTN. FRAMING WALL SEALED TO RESIST
FPASSAGE OF SMOKE ONE SIDE
oslo -3 5/8 ", 25 GA, 16" O.C. STEEL STUDS
• ONE LAYER 5/8" FIRE RATED TYPE X GYP. BD. EACH SIDE
• ACOUSTICAL INSULATION (WHERE AN STC IS REQUIRED)
• OVERALL DIM: 4-7/8"
2 HOUR FIRE BARRIER
■� ■�■ /HKM ■M■ =■ /HKM■M■M■
-19 TYPE "X" GYPSUM BOARD
SHHAALL BE CUT TO FIT WITHIN
DECK FLUTES PER MAXIMUM
GAP ALLOWED BY APPROVED
"FIRE RESISTANT JOINT SYSTEM ".
UNDERSIDE OF STRUCTURE ABOVE
3/4" STRUCTURAL DEFLECTION
ALLOWANCE
PROVIDE APPROVED "FIRE -
RSISTANT JOINT SYSTEM ". SEAL ALL
"HEAD -0F - WALLS" BOTH
AIR -TIGHT AND SOUND - TIGHT.
CONT. "C" SHAPED METAL RUNNER
(SECURED TO DECK - DO NOT
SECURE GWB OR STUDS TO
RUNNER)
CEILING AS SCHEDULED
ACOUSTICAL TCAL IN D LATION (WHERE AN
STC GYP. BD.
NON- STRUCTURAL STEEL STUDS
RUNNER TRACK (SECURED TO FLOOR)
BASE AS SCHEDULED
CONT. FIRE STOP SEALANT (BOTH SIDES)
TOP OF STRUC. SLAB
FASTENERS MAXIMUM 24" O.C.
2 2 HOUR PTN FRAMED FIRE BARRIER
• 3 5/8 ", 25 GA, 16" O.C. STEEL STUDS
• 2 LAYERS 5/8" FIRE RATED TYPE X GYP. BD. BOTH SIDES
• ACOUSTICAL INSULATION (WHERE AN STC IS REQUIRED)
• UL DESIGN NO. U411
• OVERALL DIM: 6 -1/8"
'i L f'%I In =110 DA1' nTCn /'`AAI I MA1 1
PROVIDE APPROVED "FIRE- RESISTANT
JOINT SYSTEM" PER GENERAL NOTE 3
THIS SHEET. ALSO, SEAL ALL
HEAD -OF - WALLS" BOTH AIR -TIGHT
AND SOUND- TIGHT.
STRUCTURAL BRACE SEE
STRUCTURAL FOR TYPE
SIZE AND LOCATIONS OF
BRACES)
FLOOR OR ROOF
FURRING (MAY OCCUR).
SEE FLOOR PLANS FOR LOCATIONS.
RAKE MORTAR JOINT AND ADD
CONTINUOUS FIRE STOP
SEALANT BEAD
TOP OF STRUCTURAL SLAB
SEE STRUCTURAL FOR CONNECTION
OF CMU AND ITS REINFORCMENT
INTO CONCRETE FLOOR SLAB
F31 2 HOUR CMU FIRE BARRIER WALL
• 8" CONCRETE MASONRY UNIT
• UL DESIGN NO. U906
• OVERALL DIM: 7 -5/8"
F041 NON -RATED CMU WALL
- 8" CONCRETE MASONRY UNIT
• OVERALL DIM: 7 -5/8"
---- --- ---
GENERAL NOTES FOR WALLS /PARTITIONS /BARRIERS -
1. ALL INTERIOR PARTITION TYPES SHALL BE N00 UNLESS NOTED OTHERWISE. ALL EXTERIOR CMU WALL TYPES TO BE A04 UNLESS NOTED OTHERWISE.
2. RATED GYPSUM BOARD ASSEMBLIES:
COMPLY WITH CITED REFERENCE STANDARDS AND THE MOST CURRENT EDITION OF THE "GYPSUM ASSOCIATION GA -600 FIRE RSISTANCE DSIGN MANUAL". SEE DETAIL
5/A8.1 "LOCATION OF JOINTS IN GYPSUM BOARD WALLS /PARTITIONS /BARRIERS" FOR DETAILS PERTAINING TO METAL STUD AND GYPSUM BOARD WALLS. SEE
SPECIFICATIONS IN THE PROJECT MANUAL FOR REQUIRED GAGE OF METAL STUDS.
3. TOPS OF GYPSUM PARTITIONS/FIRE RSISTANCE RATED ASSEMBLIES:
NON -RATED GYPSUM ASSEMBLIES: EXTEND GYPSUM BOARD TO 1/2" BELOW STRUCTURAL DECK AND APPLY ACOUSTICAL SEALANT ONE SIDE PER SPEC SECTION 09 2900.
ACOUSTICALLY -RATED ASSEMBLIES: CUT GYPSUM BOARD TO FOLLOW PROFILE OF STRUCTURAL DECK WITHIN 1/2" AND APPLY ACOUSTICAL SEALANT BOTH SIDES PER
SPEC SECTION 09 2900.
FIRE-RESISTANCE RATED ASSEMBLIES: CUT GYPSUM BOARD TO FOLLOW PROFILE OF STRUCTURAL DECK WITHIN 1/2" AND APPLY FIRE - RESISTIVE JOINT SYSTEM PER SPEC
SECTION 07 8446.
(A) AT ALL RATED WALLS /BARRIERS, PROVIDE AN APPROVED U.L. TESTED "FIRE- RESISTANT JOINT SYSTEM" TO COMPLY WITH NOTE 6 BELOW.
4. PENETRATIONS:
FIRE - RSISTANCE RATED ASSEMBLIES: FIRSTOPPING PER SPEC SECTION 07 8413.
ACOUSTICALLY -RATED ASSEMBLIES: ACOUSTICAL GASKETS OR ACOUSTICAL SEALANT PER SPEC SECTION 09 2900.
NON -RATED ASSEMBLIES: SEALS NOT REQUIRED.
ELECTRICAL BOXES: MAXIMUM 1/8" PERIMETER JOINTS. SEE DETAIL 3/A8.1 "METALLIC ELECTRICAL OUTLET BOXES RECESSED IN WALLS, PARTITIONS, RATED FIRE
BARRIERS & RATED SMOKE BARRIERS ".
FOR ALL FIRE BARRIERS, AND FIRE WALLS, SURFACE AREA OF INDMDUAL RECESSED METALLIC ELECTRIC OUTLET BOXES SHALL NOT EXCEED 16 SQUARE INCHES.
AGGREGATE SURFACE AREA OF RECESSED METALLIC BOXES SHALL NOT EXCEED 100 SQUARE INCHES PER 100 SQUARE FEET OF SURFACE WALL AREA. BOXES THAT EXCEED
EITHER 16 SQUARE INCHES OR THE AGGREGATE AREA LIMITATION SHALL COMPLY WITH REQUIREMENTS OF NFPA 101, SECTION 8.3.5.6.3 AND FBC SECTION 712.3.2.
RECESSED METALLIC BOXES LOCATED ON OPPOSITE SIDES OF FIRE BARRIERS SHALL BE SEPARATED BY MINIMUM 24 -INCH HORIZONTAL DISTANCE PER DETAIL 3/A8.1
COMPLY WITH REQUIREMENTS OF NFPA 101, SECTION 8.3.5.6.3 AND FBC SECTION 712.3.2.
OTHER PENETRATIONS: MAXIMUM 1/4" PERIMETER JOINTS.
THE GAPS ROUND ALL PENETRATIONS SHALL BE SEALED AIR -TIGHT & SOUND - TIGHT. COMPLY WITH NOTE 6 BELOW. PROVIDE STEEL STUD FRAMING ROUND ALL
PENETRATIONS THROUGH GYPSUM BOARD PARTITIONS PER DETAILS 6/A8.2 AND 11A/A8.2, SEAL PENETRATIONS THROUGH BOTH RATED BARRIERS & NON -RATED
PARTITIONS TO COMPLY WITH SOUND TRANSMISSION LIMITATIONS PER NOTE 7 BELOW.
THE CONTRACTOR SHALL BE RSPONSIBLE FOR COORDINATING WITH THE OWNER'S EQUIPMENT VENDORS TO INSURE THAT THERE WILL BE NO OWNER FURNISHED ITEMS
(WITH A SURFACE AREA GREATER THAN 16 SQUARE INCHES) RECESSED INTO A RATED FIRE BARRIER. SEE DETAIL 5/A8.2, RECESSED METAL WALL CABINETS FOR
DETAILS ON HOW TO PROVIDE FOR RECESSED ITEMS IN A RATED FIRE BARRIER. ITEMS RECESSED IN NON -RATED SMOKE PARTITIONS OR ALL OTHER FULL HEIGHT
PARTITIONS SHALL BE SEALED "AIR- TIGHT' AT ALL PENETRATIONS.
S. BOTTOMS OF ASSEMBLIES:
MINIMUM 1/4" TO MAXIMUM 1/2" GAP AT FLOOR SLAB.
FIRE-RESISTANCE RATED ASSEMBLIES: COMPLY WITH INDICATED UL OR GA DESIGN. WHERE GAP EXCEEDS 1/2" PROVIDE FIRE-RESISTIVE JOINT SYSTEM PER SPEC
SECTION 07 8446.
ACOUSTICALLY -RATED ASSEMBLIES: ACOUSTICAL SEALANT BOTH SIDES PER SPEC SECTION 09 2900. APPLY SEALANT BEAD TO FLOOR AND SET GYPSUM BOARD INTO WET
SEALANT.
NON -RATED ASSEMBLIES: SEALS NOT REQUIRED.
6. FOR ALL RATED WALLS /BARRIERS: PER THE REQUIREMENTS OF FBC SECTIONS 712 & 713, PROVIDE APPROVED U.L TESTED "FIRE- RESISTANT JOINT SYSTEM" OR
THROUGH - PENETRATION FIRESTOP SYSTEM TO COMPLY WITH ALL REQUIREMENTS OF EACH SPECIFIC CONDITION AS APPROPRIATE FOR ALL ADJACENT COMPONENTS PER
THE REQUIREMENTS OF THE MOST CURRENT EDITION OF THE "U.L. FIRE RSISTANCE DIRECTORY - VOLUME 2A ", AND COMPLY WITH SPECIFICATION SECTION 07 8413
"PENETRATION FIRESTOPPING" AND SPECIFICATION SECTION 07 8446 "FIRE - RSISTIVE JOINT SYSTEMS ".
7. ACOUSTICAL SEPARATION ASSEMBLIES:
NON -RATED ACOUSTICAL ASSEMBLIES: APPLY ACOUSTICAL INSULATION IN EACH STUD SPACE WITHOUT GAPS OR VOIDS TO PROVIDE FULL COVERAGE. APPLY ACOUSTICAL
SEALANT TO BOTH SIDES OF TOPS AND BOTTOMS OF WALLS AND VERTICAL JOINTS WITH OTHER CONSTRUCTION. INSTALL ELECTRICAL BOXES ON OPPOSITE SIDES OF
PARTITION IN DIFFERENT STUD SPACES AND PROVIDE GASKET SEALS. APPLY ACOUSTICAL SEALANT TO OTHER PENETRATIONS.
STC -RATED ACOUSTICAL ASSEMBLIES: COMPLY WITH REFERENCED DSIGN STANDARD TO ACHIEVE INDICATED RATINGS.
8. STEEL STUD FRAMING:
STRUCTURAL COLD - FORMED METAL FRAMING IS DSIGNATED AS CFMF IN PARTITION TYPES AND DRAWING NOTES AND IS SPECIFIED ON THE STRUCTURAL DRAWINGS.
CONTRACTOR IS RESPONSIBLE FOR DELEGATED DESIGN OF CFMF ASSEMBLIES FOR BOTH EXTERIOR AND INTERIOR APPLICATIONS.
ALL OTHER STEEL STUD FRAMING IS NONSTRUCTURAL TYPE SPECIFIED IN SECTION 09 2216.
9. THE ENCLOSURE WALLS /PARTITIONS /BARRIERS SHALL BE EXTENDED UP TO THE DECK ABOVE AND BE SEALED "AIR- TIGHT' IN SPACES WHERE SOUND TRANSMISSION
LIMITATIONS RE EITHER REQUIRED BY THE CODE OR NECESSARY TO COMPLY WITH GOOD DESIGN PRACTICE. SEE SOUND TRANSMISSION LIMITATIONS CHART BELOW FOR
LOCATIONS WHERE THIS IS REQUIRED.
10. AS REQUIRED BY THE 2010 EDITION OF THE FLORIDA BUILDING CODE:
PER FBC SECTION 419.3.9.5, ALL FIRE -RATED BARRIERS AROUND EXIT PASSAGEWAYS SHALL BE CONSTRUCTED BEFORE THE CONSTRUCTION OF INTERVENING LOWER
PRIORITY WALLS. SEE DETAIL 15/A8.1 "PRIORITY LEGEND FOR ABUTMENT OF DIFFERING WALLS /PARTITIONS/ BARRIERS ".
PER FBC SECTION 419.3.9.8, WHERE ELECTRICAL CONDUITS, CABLE TRAYS, DUCTS AND UTILITY PIPES PASS THROUGH A RATED FIRE BARRIER, THE UTILITIES SHALL BE
LOCATED SO THAT ACCESS IS MAINTAINED TO ADJACENT WALL SURFACES AND TO ALL DAMPER ACCESS PANELS. THERE SHALL ALSO BE A MINIMUM CLEARANCE OF 6
INCHES BETWEEN ALL CONDUITS, PIPING, AND DUCTWORK THAT ARE PARALLEL (OR ADJACENT) TO RATED WALLS /BARRIERS, IN ORDER TO FACILITATE THE INSPECTION
OF THESE RATED WALLS /BARRIERS.
SOUND TRANSMISSION
LIMITATIONS
REFERENCED FROM THE
"2010 GUIDELINS FOR DSIGN AND CONSTRUCTION OF HEALTH CARE FACILITIS"
TABLE 1.2 -3
DESIGN CRITERIA FOR MINIMUM SOUND ISOLATION PERFORMANCE BETWEEN ENCLOSED ROOMS
Adjacency combination
STC'
T
T
m
EXAM ROOM TO PUBLIC SPACE
co
EXAM ROOM TO CORRIDOR (WITH ENTANCE)
T
TOILET ROOM TO PUBLIC SPACE
_0
_ m
-v
a)
50
CONSULTATION ROOMS /CONFERENCE ROOMS
C
353
o
3
U
L
v
a)
CL
L
L
a
0
U
Q
N M Q Ln
M M M
zzzzz
_3 _J J -I -__I
n
a) a)
L L
p 7 7
Uj N N
)M JW rn'TU -i
n CL U. W.- NMQL17
V -Nz tL t'I..L_I..L_LL LL_L.�
>-- W U U Q W W W W W
Inmu_ L Ldp =1===
L fA 4% 1% Q Q H! EA iA f% fH fA
a�
a
v
CL
a
Ln
(D
c
a�
a
i
U)
V �
L
o
o cn
J"M c v
10 a- --
�Nrn C
1.'- o *,% _ • -
n \ N
°
m �
WALLS /PARTITIONS /BARRIERS LEGEND
NON -RATED GWB PARTITION
FASTENERS MAXIMUM 24" O.C.
UNDERSIDE OF STRUCTURAL FLOOR/ROOF
1/2" STRUCTURAL DEFLECTION
ALLOWANCE
CONT. ACOUSTICAL SEALANT BOTH SIDES
DEFLECTION TRACK FOR
1/2" OR LESS MOVEMENT.
ACOUSTICAL INSULATION (WHERE AN
STC IS REQUIRED)
CEILING AS SCHEDULED
GYP. BD.
NON- STRUCTURAL STEEL STUDS
RUNNER TRACK (SECURED TO FLOOR)
BASE AS SCHEDULED
CONT. ACOUSTICAL SEALANT
BOTH SIDES
TOP OF STRUC. SLAB
FASTENERS MAXIMUM 24" O.C.
ONE LAYER GYP BD EACH SIDE APPLIED VERTICALLY. STAGGER
° ABUTTING END JOINTS NOT LESS THAN ONE FRAMING MEMBER IN
ALTERNATE COURSES OF PANELS. REFER TO SECTION 09 2900
OF PROJECT MANUAL FOR MORE INFORMATION.
SEE GENERAL NOTES FOR WALLS /PARTITIONS ON SHEET X1.2
° FOR ADDITIONAL INFORMATION AND REQUIREMENTS.
-RATED PTN. I oo I NO ABOVE FILING RA
PARTITION
• 3 5/8 ", 25 GA, 16" O.C. STEEL STUDS
• ONE LAYER 5/8" GYP. BD. EACH SIDE TO 4" ABOVE CEILING
- ACOUSTICAL INSULATION (WHERE INDICATED)
- TERMINATE PARTITION AT UNDERSIDE STRUCT. FLOOR/ROOF
• OVERALL DIM: 4-7/8"
0 0 0 ovL1-) 0 0 0 ov1 1) 0 0 0 orI1-) 0
NON -RATED PTN. FRAMED PARTITION TO DECK
01 -3 5/8 ", 25 GA, 16" O.C. STEEL STUDS
• ONE LAYER 5/8" GYP. BD. EACH SIDE
• ACOUSTICAL INSULATION (WHERE AN STC IS REQUIRED)
• TERMINATE PARTITION AT UNDERSIDE STRUCT. FLOOR/ROOF
• OVERALL DIM: 4-7/8"
NON -RATED PTN. FRAMED PARTITION TO DECK
02 -3 5/8 ", 25 GA, 16" O.C. STEEL STUDS
- ONE LAYER 5/8" GYP. BD. OFFICE SIDE
• TWO LAYERS 5/8" GYP. BD. LOBBY/ CORRIDOR SIDE
-ACOUSTICAL INSULATION (WHERE AN STC IS REQUIRED)
- TERMINATE PARTITION AT UNDERSIDE STRUCT. FLOOR/ROOF
• OVERALL DIM: 4-7/8"
*WHEN SOUND ATTENUATION BLANKETS ARE INDICATED TO BE
USED BUT AN STC RATING IS NOT REQUIRED PROVIDE A MINIMUM
OF OhE LAYER OF GYPSUM BOARD ON AT LEAN ONE SIDE OF THE
PARTITION (UP TO DECK ABOVE).*
*PROVIDE SLOTTED SLIP TRACK TO ALLOW 1" VERTICAL
DEFLECTION AT TOP OF ALL 1ST FLOOR PARTITIONS TO DECK.
PARTITION SEALED TO RESIST
PASSAGE OF SMOKE ONE SIDE
■ ■ ■ ■ 11�TP ■ ■ ■ ■ ■ ■ ■ ■
5/8" TYPE "X" GYPSUM BOARD
SHALL BE CUT TO FIT WITHIN 1/2"
OF DECK FLUTES.
FILL FLUTES WITH MINERAL WOOL
UNDERSIDE OF STRUCTURAL FLOOR/ROOF
1/2" STRUCTURAL DEFLECTION
ALLOWANCE
CONT. ACOUSTICAL SEALANT BOTH SIDES
SEAL ALL "HEAD -OF- WALLS" BOTH
AIR -TIGHT AND SOUND- TIGHT.
DEFLECTION TRACK FOR
1/2" OR LESS MOVEMENT.
WHERE STC RATING IS NOT REQUIRED GYP.
BD. MAY TERMINATE 6" ABOVE CEILINd
CEILING AS SCHEDULED
ACOUSTICAL INSULATION (WHERE AN
STC IS REQUIRED)
GYP. BD.
NON - STRUCTURAL STEEL STUDS
RUNNER TRACK (SECURED TO FLOOR)
BASE AS SCHEDULED
CONT. ACOUSTICAL SEALANT (BOTH SIDES)
TOP OF STRUC. SLAB
FASTENERS MAXIMUM 24" O.C.
5l8" TYPE "X" GYPSUM BOARD
SHHALL BE CUT TO FIT WITHIN
DECK FLUTES PER MAXIMUM
GAP ALLOWED BY APPROVED
"FIRE RSISTANT JOINT SYSTEM ".
UNDERSIDE OF STRUCTURAL FLOOR/ROOF
1/2" STRUCTURAL DEFLECTION
ALLOWANCE
CONT. FIRE STOP SEALANT BOTH SIDES
PROVIDE APPROVED "FIRE -
RSISTANT JOINT SYSTEM ". SEAL ALL
"HEAD -0F - WALLS" BOTH
AIR -TIGHT AND SOUND- TIGHT.
DEFLECTION TRACK FOR
1/2" OR LESS MOVEMENT.
CEILING AS SCHEDULED
ACOUSTICAL INSULATION (WHERE AN
STC IS REQUIRED)
GYP. BD.
NON- STRUCTURAL STEEL STUDS
RUNNER TRACK (SECURED TO FLOOR)
BASE AS SCHEDULED
CONT. FIRE STOP SEALANT (BOTH SIDES)
TOP OF STRUC. SLAB
FASTENERS MAXIMUM 24" O.C.
A 1 HOUR PTN FRAMED FIRE BARRIER
- 3 5/8 ", 25 GA, 16" O.C. STEEL STUDS
- ONE LAYER 5/8" FIRE RATED TYPE X GYP. BD. EACH SIDE
- ACOUSTICAL INSULATION (WHERE AN STC IS REQUIRED)
■ UL DESIGN NO. U465
-OVERALL DIM: 4-7/8"
° (3 5/8' MINIMUM) METAL STUDS AT 1'-4 ")MAXIMUM O.C.
ItENQUIREM CLOSER
TS OF "GENERAL NOTES FOR WALLS /P RTITIONS /BARRIERS"
ON THIS SHEET.
° THIS PARTITION TO RESIST PASSAGE OF SMOKE ON ONE SIDE SHALL ALSO
COMPLY WITH ALL REQUIREMENTS OF 2009 NFPA 101 LIFE SAFETY CODE
SECTION 8.5 AND *REFERENCE APPROPRIATE FBC SECTIONS FOR
FLORIDA PROJECTS*
° MINIMUM OF ONE LAYER 5/8" TYPE "X" GYPSUM BOARD
EACH SIDE APPLIED VERTICALLY. PROVIDE ADDITIONAL
LAYERS OF GYPSUM BOARD WHEN REQUIRED TO OBTAIN THE INDICATED
STC RATING. STAGGER ALL VERTICAL JOINTS 1'-4" MINIMUM O.C. AND
STAGGER ALL HORIZONTAL JOINTS 2' -0" MINIMUM O.C. ALL HORIZONTAL
JOINTS SHALL OCCUR ABOVE THE CEILING. APPLY 1" TYPE "S" STEEL
SCREWS AT 8" O.C. ALONG EDGES OF BOARD AND AT V -0" O.C. IN THE
FIELD OF THE BOARD.
° SEAL GYPSUM BOARD TO FLOOR SLAB BELOW PER GENERAL
NOTES 5 AND 6. EXTEND GYPSUM BOARD TO DECK ABOVE
AND SEAL PER GENERAL NOTES 3 AND 5. SEAL ALL PENETRATIONS PER
GENERAL NOTES 4 AND 7.
*PROVIDE SLOTTED SLIP TRACK TO ALLOW 1" VERTICAL
DEFLECTION AT TOP OF ALL 1ST FLOOR PARTITIONS TO DECK.
PTN. FRAMING WALL SEALED TO RESIST
FPASSAGE OF SMOKE ONE SIDE
oslo -3 5/8 ", 25 GA, 16" O.C. STEEL STUDS
• ONE LAYER 5/8" FIRE RATED TYPE X GYP. BD. EACH SIDE
• ACOUSTICAL INSULATION (WHERE AN STC IS REQUIRED)
• OVERALL DIM: 4-7/8"
2 HOUR FIRE BARRIER
■� ■�■ /HKM ■M■ =■ /HKM■M■M■
-19 TYPE "X" GYPSUM BOARD
SHHAALL BE CUT TO FIT WITHIN
DECK FLUTES PER MAXIMUM
GAP ALLOWED BY APPROVED
"FIRE RESISTANT JOINT SYSTEM ".
UNDERSIDE OF STRUCTURE ABOVE
3/4" STRUCTURAL DEFLECTION
ALLOWANCE
PROVIDE APPROVED "FIRE -
RSISTANT JOINT SYSTEM ". SEAL ALL
"HEAD -0F - WALLS" BOTH
AIR -TIGHT AND SOUND - TIGHT.
CONT. "C" SHAPED METAL RUNNER
(SECURED TO DECK - DO NOT
SECURE GWB OR STUDS TO
RUNNER)
CEILING AS SCHEDULED
ACOUSTICAL TCAL IN D LATION (WHERE AN
STC GYP. BD.
NON- STRUCTURAL STEEL STUDS
RUNNER TRACK (SECURED TO FLOOR)
BASE AS SCHEDULED
CONT. FIRE STOP SEALANT (BOTH SIDES)
TOP OF STRUC. SLAB
FASTENERS MAXIMUM 24" O.C.
2 2 HOUR PTN FRAMED FIRE BARRIER
• 3 5/8 ", 25 GA, 16" O.C. STEEL STUDS
• 2 LAYERS 5/8" FIRE RATED TYPE X GYP. BD. BOTH SIDES
• ACOUSTICAL INSULATION (WHERE AN STC IS REQUIRED)
• UL DESIGN NO. U411
• OVERALL DIM: 6 -1/8"
'i L f'%I In =110 DA1' nTCn /'`AAI I MA1 1
PROVIDE APPROVED "FIRE- RESISTANT
JOINT SYSTEM" PER GENERAL NOTE 3
THIS SHEET. ALSO, SEAL ALL
HEAD -OF - WALLS" BOTH AIR -TIGHT
AND SOUND- TIGHT.
STRUCTURAL BRACE SEE
STRUCTURAL FOR TYPE
SIZE AND LOCATIONS OF
BRACES)
FLOOR OR ROOF
FURRING (MAY OCCUR).
SEE FLOOR PLANS FOR LOCATIONS.
RAKE MORTAR JOINT AND ADD
CONTINUOUS FIRE STOP
SEALANT BEAD
TOP OF STRUCTURAL SLAB
SEE STRUCTURAL FOR CONNECTION
OF CMU AND ITS REINFORCMENT
INTO CONCRETE FLOOR SLAB
F31 2 HOUR CMU FIRE BARRIER WALL
• 8" CONCRETE MASONRY UNIT
• UL DESIGN NO. U906
• OVERALL DIM: 7 -5/8"
F041 NON -RATED CMU WALL
- 8" CONCRETE MASONRY UNIT
• OVERALL DIM: 7 -5/8"
---- --- ---
GENERAL NOTES FOR WALLS /PARTITIONS /BARRIERS -
1. ALL INTERIOR PARTITION TYPES SHALL BE N00 UNLESS NOTED OTHERWISE. ALL EXTERIOR CMU WALL TYPES TO BE A04 UNLESS NOTED OTHERWISE.
2. RATED GYPSUM BOARD ASSEMBLIES:
COMPLY WITH CITED REFERENCE STANDARDS AND THE MOST CURRENT EDITION OF THE "GYPSUM ASSOCIATION GA -600 FIRE RSISTANCE DSIGN MANUAL". SEE DETAIL
5/A8.1 "LOCATION OF JOINTS IN GYPSUM BOARD WALLS /PARTITIONS /BARRIERS" FOR DETAILS PERTAINING TO METAL STUD AND GYPSUM BOARD WALLS. SEE
SPECIFICATIONS IN THE PROJECT MANUAL FOR REQUIRED GAGE OF METAL STUDS.
3. TOPS OF GYPSUM PARTITIONS/FIRE RSISTANCE RATED ASSEMBLIES:
NON -RATED GYPSUM ASSEMBLIES: EXTEND GYPSUM BOARD TO 1/2" BELOW STRUCTURAL DECK AND APPLY ACOUSTICAL SEALANT ONE SIDE PER SPEC SECTION 09 2900.
ACOUSTICALLY -RATED ASSEMBLIES: CUT GYPSUM BOARD TO FOLLOW PROFILE OF STRUCTURAL DECK WITHIN 1/2" AND APPLY ACOUSTICAL SEALANT BOTH SIDES PER
SPEC SECTION 09 2900.
FIRE-RESISTANCE RATED ASSEMBLIES: CUT GYPSUM BOARD TO FOLLOW PROFILE OF STRUCTURAL DECK WITHIN 1/2" AND APPLY FIRE - RESISTIVE JOINT SYSTEM PER SPEC
SECTION 07 8446.
(A) AT ALL RATED WALLS /BARRIERS, PROVIDE AN APPROVED U.L. TESTED "FIRE- RESISTANT JOINT SYSTEM" TO COMPLY WITH NOTE 6 BELOW.
4. PENETRATIONS:
FIRE - RSISTANCE RATED ASSEMBLIES: FIRSTOPPING PER SPEC SECTION 07 8413.
ACOUSTICALLY -RATED ASSEMBLIES: ACOUSTICAL GASKETS OR ACOUSTICAL SEALANT PER SPEC SECTION 09 2900.
NON -RATED ASSEMBLIES: SEALS NOT REQUIRED.
ELECTRICAL BOXES: MAXIMUM 1/8" PERIMETER JOINTS. SEE DETAIL 3/A8.1 "METALLIC ELECTRICAL OUTLET BOXES RECESSED IN WALLS, PARTITIONS, RATED FIRE
BARRIERS & RATED SMOKE BARRIERS ".
FOR ALL FIRE BARRIERS, AND FIRE WALLS, SURFACE AREA OF INDMDUAL RECESSED METALLIC ELECTRIC OUTLET BOXES SHALL NOT EXCEED 16 SQUARE INCHES.
AGGREGATE SURFACE AREA OF RECESSED METALLIC BOXES SHALL NOT EXCEED 100 SQUARE INCHES PER 100 SQUARE FEET OF SURFACE WALL AREA. BOXES THAT EXCEED
EITHER 16 SQUARE INCHES OR THE AGGREGATE AREA LIMITATION SHALL COMPLY WITH REQUIREMENTS OF NFPA 101, SECTION 8.3.5.6.3 AND FBC SECTION 712.3.2.
RECESSED METALLIC BOXES LOCATED ON OPPOSITE SIDES OF FIRE BARRIERS SHALL BE SEPARATED BY MINIMUM 24 -INCH HORIZONTAL DISTANCE PER DETAIL 3/A8.1
COMPLY WITH REQUIREMENTS OF NFPA 101, SECTION 8.3.5.6.3 AND FBC SECTION 712.3.2.
OTHER PENETRATIONS: MAXIMUM 1/4" PERIMETER JOINTS.
THE GAPS ROUND ALL PENETRATIONS SHALL BE SEALED AIR -TIGHT & SOUND - TIGHT. COMPLY WITH NOTE 6 BELOW. PROVIDE STEEL STUD FRAMING ROUND ALL
PENETRATIONS THROUGH GYPSUM BOARD PARTITIONS PER DETAILS 6/A8.2 AND 11A/A8.2, SEAL PENETRATIONS THROUGH BOTH RATED BARRIERS & NON -RATED
PARTITIONS TO COMPLY WITH SOUND TRANSMISSION LIMITATIONS PER NOTE 7 BELOW.
THE CONTRACTOR SHALL BE RSPONSIBLE FOR COORDINATING WITH THE OWNER'S EQUIPMENT VENDORS TO INSURE THAT THERE WILL BE NO OWNER FURNISHED ITEMS
(WITH A SURFACE AREA GREATER THAN 16 SQUARE INCHES) RECESSED INTO A RATED FIRE BARRIER. SEE DETAIL 5/A8.2, RECESSED METAL WALL CABINETS FOR
DETAILS ON HOW TO PROVIDE FOR RECESSED ITEMS IN A RATED FIRE BARRIER. ITEMS RECESSED IN NON -RATED SMOKE PARTITIONS OR ALL OTHER FULL HEIGHT
PARTITIONS SHALL BE SEALED "AIR- TIGHT' AT ALL PENETRATIONS.
S. BOTTOMS OF ASSEMBLIES:
MINIMUM 1/4" TO MAXIMUM 1/2" GAP AT FLOOR SLAB.
FIRE-RESISTANCE RATED ASSEMBLIES: COMPLY WITH INDICATED UL OR GA DESIGN. WHERE GAP EXCEEDS 1/2" PROVIDE FIRE-RESISTIVE JOINT SYSTEM PER SPEC
SECTION 07 8446.
ACOUSTICALLY -RATED ASSEMBLIES: ACOUSTICAL SEALANT BOTH SIDES PER SPEC SECTION 09 2900. APPLY SEALANT BEAD TO FLOOR AND SET GYPSUM BOARD INTO WET
SEALANT.
NON -RATED ASSEMBLIES: SEALS NOT REQUIRED.
6. FOR ALL RATED WALLS /BARRIERS: PER THE REQUIREMENTS OF FBC SECTIONS 712 & 713, PROVIDE APPROVED U.L TESTED "FIRE- RESISTANT JOINT SYSTEM" OR
THROUGH - PENETRATION FIRESTOP SYSTEM TO COMPLY WITH ALL REQUIREMENTS OF EACH SPECIFIC CONDITION AS APPROPRIATE FOR ALL ADJACENT COMPONENTS PER
THE REQUIREMENTS OF THE MOST CURRENT EDITION OF THE "U.L. FIRE RSISTANCE DIRECTORY - VOLUME 2A ", AND COMPLY WITH SPECIFICATION SECTION 07 8413
"PENETRATION FIRESTOPPING" AND SPECIFICATION SECTION 07 8446 "FIRE - RSISTIVE JOINT SYSTEMS ".
7. ACOUSTICAL SEPARATION ASSEMBLIES:
NON -RATED ACOUSTICAL ASSEMBLIES: APPLY ACOUSTICAL INSULATION IN EACH STUD SPACE WITHOUT GAPS OR VOIDS TO PROVIDE FULL COVERAGE. APPLY ACOUSTICAL
SEALANT TO BOTH SIDES OF TOPS AND BOTTOMS OF WALLS AND VERTICAL JOINTS WITH OTHER CONSTRUCTION. INSTALL ELECTRICAL BOXES ON OPPOSITE SIDES OF
PARTITION IN DIFFERENT STUD SPACES AND PROVIDE GASKET SEALS. APPLY ACOUSTICAL SEALANT TO OTHER PENETRATIONS.
STC -RATED ACOUSTICAL ASSEMBLIES: COMPLY WITH REFERENCED DSIGN STANDARD TO ACHIEVE INDICATED RATINGS.
8. STEEL STUD FRAMING:
STRUCTURAL COLD - FORMED METAL FRAMING IS DSIGNATED AS CFMF IN PARTITION TYPES AND DRAWING NOTES AND IS SPECIFIED ON THE STRUCTURAL DRAWINGS.
CONTRACTOR IS RESPONSIBLE FOR DELEGATED DESIGN OF CFMF ASSEMBLIES FOR BOTH EXTERIOR AND INTERIOR APPLICATIONS.
ALL OTHER STEEL STUD FRAMING IS NONSTRUCTURAL TYPE SPECIFIED IN SECTION 09 2216.
9. THE ENCLOSURE WALLS /PARTITIONS /BARRIERS SHALL BE EXTENDED UP TO THE DECK ABOVE AND BE SEALED "AIR- TIGHT' IN SPACES WHERE SOUND TRANSMISSION
LIMITATIONS RE EITHER REQUIRED BY THE CODE OR NECESSARY TO COMPLY WITH GOOD DESIGN PRACTICE. SEE SOUND TRANSMISSION LIMITATIONS CHART BELOW FOR
LOCATIONS WHERE THIS IS REQUIRED.
10. AS REQUIRED BY THE 2010 EDITION OF THE FLORIDA BUILDING CODE:
PER FBC SECTION 419.3.9.5, ALL FIRE -RATED BARRIERS AROUND EXIT PASSAGEWAYS SHALL BE CONSTRUCTED BEFORE THE CONSTRUCTION OF INTERVENING LOWER
PRIORITY WALLS. SEE DETAIL 15/A8.1 "PRIORITY LEGEND FOR ABUTMENT OF DIFFERING WALLS /PARTITIONS/ BARRIERS ".
PER FBC SECTION 419.3.9.8, WHERE ELECTRICAL CONDUITS, CABLE TRAYS, DUCTS AND UTILITY PIPES PASS THROUGH A RATED FIRE BARRIER, THE UTILITIES SHALL BE
LOCATED SO THAT ACCESS IS MAINTAINED TO ADJACENT WALL SURFACES AND TO ALL DAMPER ACCESS PANELS. THERE SHALL ALSO BE A MINIMUM CLEARANCE OF 6
INCHES BETWEEN ALL CONDUITS, PIPING, AND DUCTWORK THAT ARE PARALLEL (OR ADJACENT) TO RATED WALLS /BARRIERS, IN ORDER TO FACILITATE THE INSPECTION
OF THESE RATED WALLS /BARRIERS.
SOUND TRANSMISSION
LIMITATIONS
REFERENCED FROM THE
"2010 GUIDELINS FOR DSIGN AND CONSTRUCTION OF HEALTH CARE FACILITIS"
TABLE 1.2 -3
DESIGN CRITERIA FOR MINIMUM SOUND ISOLATION PERFORMANCE BETWEEN ENCLOSED ROOMS
Adjacency combination
STC'
EXAM ROOM TO EXAM ROOM
50
EXAM ROOM TO PUBLIC SPACE
50
EXAM ROOM TO CORRIDOR (WITH ENTANCE)
353
TOILET ROOM TO PUBLIC SPACE
45
CONSULTATION ROOMS /CONFERENCE ROOMS
TO PUBLIC SPACE
50
CONSULTATION ROOMS /CONFERENCE ROOMS
TO CORRIDOR (WITH ENTRANCE)
353
STC VALUES STATED ARE BETWEEN ROOMS (NOT SPACES).
THE PERFORMANCE OF THIS CONSTRUCTION ASSUMES A CLOSED DOOR.
Ilk
fA
N f
'4
----
C.S &I'`II
Design Services
For The Built
Environment
3 ■
Atlanta 3Birmingham
Cincinnati
Columbus Dallas
Fort Lauderdale
Knoxville Jackson
Jacksonville Louisville
Memphis Nashville
Richmond Tampa
2
G R E3.S H A M
SMITH AND
P A R T N E R S
6030 Hollywood Blvd.
Suite 210
Hollywood, Florida 33024
954.981.9100
FIRM'S FLORIDA
CERT. NO.
AAP000034 /CA3806
IB26000797/LC26000381
L5 M
L� Wa
m thO
O r\ -
�0�
C -� Lo
v� Q ��
-1 0
W o
SEAL: Kristin S. Herman -Druck
AR95172
�L
REVISION
1 No. - Date - Revision I
WALLS /PARTITIONS/
BARRIERS NOTES & LEGEND
X1.2
FILE: 9080X102.dgn
PROJECT: 29080.00
DATE: 12/1412012
Copyright Z01Z Gresham, 5mitn ana Nartners. Hll rclgnts rceservea. -
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- - - - - -- --