13-96 (2)-176TYPICAL CONDUIT CONCEALED CEILING SLAB ABOVE SUSPENDED CEILING TO CEILING SLAB NEXT JUNCTION BOX OR HOMERUN. d' • �" COIL CLEARING - - - JUNCTION BOX INSTALLED ABOVE - _ - ' I 2 CTS I CEILING r� %' / / a CEILING. — AVOID CABLE HOLES, 1 HANGER r ~ A/C DUCT, ETC. 4 f. - - - - - - - WIRE :�,.. , t ,, I ` NC I a• � � GFl DEDICATED RECEPTACLE I LS -2 NO C N FIXTURE • Q I O j'`'j WP NEMA 3R O fir+ I O O I I O Q QQ I I I LS -2 t SITE LIGHTS O O I I Z 2 QQ QQ I I I LS -4 SITE LIGHTS I PITCH PAN 1 1 3 G O W/ PITCH I I co LS -6 SITE LIGHTS 4 SUSPENDED O FLEXIBLE CONDUIT I SITE LIGHTS I CEILING GRID ALLOW SUFFICIENT SLACK LS -8 BY OTHERS SO THAT FIXTURE CAN BE ROOF DECK I LS -10 5 SITE LIGHTS BE SHIFTED ONE COMPLETE e TILE IN ANY DIRECTION • . : . • CKT#6 SPACE I 7 I I CONDUIT CKT#7 a SPACE I 0 0 CKT#8 F-- SPACE I 0 0 O1 8 POLE, 30 AMP I LIGHTING CONTACTOR NOTES: SQUARE HELD O TIMECLOCK. I 1O PROVIDE #12 GREEN GROUND WIRE IN FLEXIBLE CONDUIT WITH BRANCH CIRCUIT WIRING AND BOND TO I OUTLET BOX AND FIXTURE HOUSING. J OZ SECURELY FASTEN FIXTURE TO CEILING FRAMING MEMBERS WITH FOUR (4) T —BAR CLIPS PER FIXTURE. SUPPORT FROM SUSPENDED CEILING ONLY AS APPROVED BY ARCHITECT. LIGHTING FIXTURE MOUNTING DETAIL ROOF RECEPTACLE DETAIL LIGHTING CONTACTOR DETAIL SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. TWIST ALL LEADS TOGETHER 2 and 4 Hour Fire Rated Through s S i f vow=., (AS MANY TURNS AS g tie !e 1 and 2 Hour Fire Rated Through SS ' Plea Penetration Firestop for Single o Q G o' PRACTICAL) AND TIE WRAP Penetration Firestop for Single 000 Metal Pipe through O 3735 Green Rd. 3735 Green ltd. Metal Pipe through BREAKER FEEDING Concrete Floors or Walls Gypsum Wall Assemblies SURGE SUPPRESSOR TYP ® Beachwood, OH, 44122 ® Beachwood OH 44122 `sYs t ed� using FYRE -SIL. `s•1's t e'er � ( ) using TREMstop IA. Drawing not to scale CAJ 1064 F- Rating = 2 and 4 Hr. 20 WL 1158 Drawing not to scale ®® D OPTIONAL TM DEVICE T- Rating = 0 Hr. � F- Rating = 1 and 2 Hr. .. � O LOCATIONS (CAT 83 OR C1 AS on ® 0 0 0 ® : �' ® � T- Rating = 1/4 Hr. INDICATED ON DRAWINGS) m m Q ..:..................... . OPTIONAL TVSS .. •� :• �� ::::.: m ® DEVICE LOCATIONS • m (CAT B3 OR C1 AS , 0 Design Services For The Built Environment N Atlanta Birmingham Cincinnati Columbus Dallas Fort Lauderdale Knoxville Jackson Jacksonville Louisville Memphis Nashville Richmond Tampa 0 G R E S H A M S M I T A N D P A R T N E R S 6030 Hollywood Blvd. Suite 210 Hollywood, Florida 33024 954.981.9100 FIRM'S FLORIDA CERT. N0, AAP000034/CA3806 IB26000797/LC26000381 ... .... oD ® PJT. YGR- JaCE M H00 on ® DRAWINGS) Pi.Vn= #: 120717 0 m on 1 Pre —Rated Concrete Floors or Block Walls: See Table below for min. thickness. 1 Pre —Rated Gypsum Wallboard /Stud Wall Assembly. on Q2 Metallic Pi A Steel R 8 o 0 0 Pipe: ) pe — 4 diem. (or smaller) Sch. 10 (or heavier) steel pipe. 2 Metallic Pipe: A) Steel Pipe — 12 diem. (or smaller) Sch. 10 (or heavier) steel pipe. B) Iron Pipe — 4" diam. (or smaller) cast or ductile iron pipe. B) Iron Pipe — 12" diam. (or smaller) cast or ductile iron pipe. C) Conduit — 4" diam. (or smaller) EMT or steel conduit. D) Copper Tubing — 4" diam. (or smaller) Type L (or heavier) copper tubing. C) Cooper Tubing — e diam. (or smaller) Type L (or heavier) cooper tubing. E) Copper Pipe — 4" diam. (or smaller) Regular (or heavier) copper pipe. 3O Packing Material — See Table below for the mineral wool insulation requirements. D) Copper Pipe — 4" diam. (or smaller) Regular (or heavier) copper pipe. ® FYRE —SIL — Min. 1/2" thickness of sealant applied within annulus, flush with top NEUTRAL BUS CONNECTION . of floor surface or with both sides of the wall assembly. E) Conduit 4 diam. (or smaller) EMT or 60 diam. (or smaller) steel conduit. :..7 � ►�—'' Min. Thickness Annular Space Min. Packing Material Min. Packing Material F— Rating The annular space shall be min. 0" to max. 1" within the firestop system. of Concrete, in. Range, in. Thickness, in. Density. Dcf Hr. p TREMstop A — Min. 1/2' thickness of sealant applied within opening. 4 -1/2 1/2 to 7/8 35 6.0 2 Min. 3 8" cant bead of sealant to be applied at areas of point contact. NOTE: MOUNT TVSS DEVICE IN A LOCATION TO MAINTAIN 5 -1 /2 0 to 1 -7/8 5 4.0 4 / PP P ALL LEADS AS SHORT AS POSSIBLE (18" MAX.) 2 AND 4 HOUR FIRE RATED THROUGH 1 AND 2 HOUR FIRE RATED THROUGH TVSS EXTERIOR MOUNT INSTALLATION SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. 38" si..: 38" 0 CONCRETE COVER INSULATING BUSHING o 1-C. W/ PULLSTRING IDENTIFICATION STRIPS STUB —UP ABOVE W/ PLASTIC COVER ACCESSIBLE CEILING (TYP. TOP AND BOTTOM) PULL SLOT TYPICAL INSERT FOR ------------------------ ------ CABLE RACKS BODY SECTION 40' 40" f 36» E 15 36" ADEQUATE RACKS : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SHALL BE PROVIDED . • l i �.�`` FOR ALL CABLES. RED 45 JACK TERM. DETAIL PULL EYE l ,. 555E 36" �. I 6- s NOTE: PLASTIC FACE PLATES 1. CONTRACTOR SHALL INCLUDE IN HIS BID THE EXACT WITH SNAP —IN INSERTS 4 3/8 CONFIGURATION REQUIRED BY THE OWNER FOR THIS PROJECT. 2. INDIVIDUAL JACK OUTLETS TO BE IDENTIFIED BY COLOR (BLUE, GREEN, PURPLE, YELLOW). 1" HOLE FOR SIDE WALL GROUND ROD KNOCKOUT END WALL 1" THREADED INSERTS KNOCKOUT OR PULL IRONS QUAZITE: PG3636DA36 WITH PG3636HAOO COVER HANDHOLE DETAIL COMMUNICATION OUTLET BOX DETAIL A G CONSULTING INEERS. INC. .8. 3rd AVS., SUITS 200 1AUDMWMZ. FL 33304 I) 527 -1112 #00009181 o � � ?� w M • �n \� to I` U_ 0 " Q Lo r 0 tCS �LO I— U_j in c `%lit::::111,� s a U No 6 p0 �.• 0� • ul ,rat mic REVISION No. — Date — Revision I ELECTRICAL DETAILS AND LIGHTING FIXTURE SCHEDULES E5.1 FILE: SCALE: N.T.S. PROJECT SCALE: N.T.S. 29080.00 11/29/2012